What are the performance specifications for the ATLANTIC TIDALWAVE L-310 pump?
The performance specifications for the ATLANTIC TIDALWAVE L-310 pump are detailed in the table below. The recommended operating range is indicated to ensure optimal performance and longevity.
| Model # | Max | 5′ | 10′ | 15′ | 20′ | 25′ | 30′ | 35′ | 40′ | 45′ | 50′ | 55′ | 60′ |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| L-310 (gph) | 13500 | 10560 | 7380 | 3240 | |||||||||
| (gpm) | 225 | 176 | 123 | 54 |
Key:
Do Not Operate Range
Recommended Operating Range
Best Efficiency Point
Important Notes:
Operating pumps outside of the recommended range may cause bearing damage and premature failure.
Never operate L-Series pumps at total dynamic head heights exceeding 15 feet.
What initial checks should be performed on the ATLANTIC TIDALWAVE L-310 pump upon delivery?
When the pump is delivered, perform the following checks before operation and installation:
Check for any damage to the pump and power cable that may have occurred during shipment.
Check the model number to make sure it is the product that was ordered and verify the voltage and frequency are correct.
What are the primary safety cautions for operating the ATLANTIC TIDALWAVE L-310 pump?
Please observe the following cautions when using your ATLANTIC TIDALWAVE L-310 pump:
DO NOT operate this product under any condition other than those for which it is specified. Failure to observe this precaution can lead to electrical shock, electrical leakage, fire, water leakage or other problems.
The ATLANTIC TIDALWAVE L-310 pump requires a single phase 115 volt / 60 hz power supply. Always verify that the supplied power meets the requirements listed on the upper pump cover.
DO NOT apply any paint over the stainless steel motor body. Reduced cooling ability will result in overheat, overload, undesirable performance reductions, periodic auto shut-off and pump malfunction.
Never place your hand or any object in or near the inlet opening while this equipment is operating. If the pump inlet is clogged, always turn off the power supply, fuse box or circuit breaker and wait until the motor is completely stopped before attempting to remove any clogged material.
Please make sure that the power plug and the AC outlet receptacle are protected and away from water or pump discharge hose to prevent accidental electric shock or short circuit.
Always operate the pump completely submerged in water.
Avoid dry operation, which will not only lower performance but can cause the pump to overheat/malfunction, leading to electrical leakage, shock or premature failure.
CAUTION: THIS PUMP IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND CIRCUIT INTERRUPTER.
CAUTION: THIS PUMP HAS BEEN EVALUATED FOR USE IN WATER ONLY.
What should I do before starting my ATLANTIC TIDALWAVE L-310 pump for the first time?
Before you start the pump, please perform the following steps:
Check the model name plate to make sure once again that the product is of the correct voltage and frequency rating.
The setting on the circuit breaker or other overload protector should be made in accordance with the rated currency of the pump.
Turn off the power supply or circuit breaker before inserting the power supply plug to avoid electrical shock, shorting, or unexpected starting of the pump, which could lead to injury.
Never operate the pump while it is suspended in air. The recoil may result in injury or other major accident.
What are the electrical safety requirements for the ATLANTIC TIDALWAVE L-310 pump?
To ensure electrical safety, follow these requirements:
Electrical wiring should be installed by a qualified electrician in accordance with all applicable safety regulations. Incorrect wiring can lead to a pump malfunction, electrical shock or fire.
Pumps should operate on a designated circuit rated at 15 Amps (minimum).
The pump must be protected by a ground fault circuit interrupter (GFCI).
The pump must be plugged into a standard, properly grounded, three-pronged outlet.
Do not cut the electrical cable. If a cable with cut insulation or other damage is submerged in water, there is a danger of water seeping into the pump motor and causing a short. This may result in damage to the pump, electrical shock or fire. Altering the electrical cable in any way will void the warranty.
Never move or handle the pump by pulling on the electrical cable. Make sure the electrical cable does not become excessively bent or twisted, does not rub against a structure in a way that might damage it, and does not come in contact with heated surfaces.
How should I properly operate my ATLANTIC TIDALWAVE L-310 pump?
For proper operation of your ATLANTIC TIDALWAVE L-310 pump, follow these guidelines:
In case of a power outage, turn off the power to the pump to avoid having it start unexpectedly when the power is restored.
L-Series pumps are cooled internally as the water flows around the motor. The intake screen on L-Series pumps must be completely submersed during operation.
In case of very excessive vibration, unusual noise or odor, turn off the power immediately and consult with your nearest dealer. Continuing to operate the pump under abnormal conditions may result in electrical leakage, electrical shock or fire.
Repeating cycles of stopping and restarting will damage the water pump. Do not continue operation at low lift, low water level, or while the inlet is clogged with debris. Not only will performance suffer, but also such conditions may cause noise, heavy vibration, and pump failure.
Why would my ATLANTIC TIDALWAVE L-310 pump stop automatically?
The ATLANTIC TIDALWAVE L-310 pump has a built-in motor protection system that may cause the pump to stop automatically regardless of the water level for the following reasons:
Motor overheating
Excessive current
Change in voltage polarity
Open-phase operation or operation under constraint
How do I perform a monthly inspection on my ATLANTIC TIDALWAVE L-310 pump?
Regular maintenance and inspections are a necessity for continued efficient functioning. For a monthly inspection, follow these steps:
1. Check for any drop in performance. Reduced performance is usually caused by debris blocking the intake screen.
2. Detach the power cable from the receptacle and turn off the power supply (circuit breaker).
3. Disconnect the pump discharge and remove the pump from the water.
4. Remove any accumulated debris from the surface of the pump, inlet screen and impeller.
5. Make sure all nuts and bolts are fastened securely.
6. Do not disassemble the pump for any reason. Refer operating and maintenance problems to a qualified technician.
How should I winterize my ATLANTIC TIDALWAVE L-310 pump?
Follow these instructions for winterizing your ATLANTIC TIDALWAVE L-310 pump:
Under no circumstances should the pump be left in frozen water.
When the pump is out of use for an extended period, wash it and dry it thoroughly, then store it indoors.
Note: Always run a test operation before putting the pump back into operation. When the pump is left installed in water it should be run at regular intervals (about once per week).
What should I do if my ATLANTIC TIDALWAVE L-310 pump does not start?
If your ATLANTIC TIDALWAVE L-310 pump fails to start, first turn off the power before inspecting it. Then, check the following possible causes and solutions:
| Possible Cause | Possible Solution |
|---|---|
| Power is off | Turn power on |
| Power failure | Check power supply or contact local power company |
| Voltage drop/Overload | Check/Replace the GFI (Ground Fault Interrupter) |
| Power cord is not connected | Connect power cord |
Why does my ATLANTIC TIDALWAVE L-310 pump stop after starting?
If your ATLANTIC TIDALWAVE L-310 pump stops shortly after starting, always turn off the power before inspecting it. Here are the potential causes and solutions:
| Possible Cause | Possible Solution |
|---|---|
| Pump is overheating | Submerge pump/Raise water level/Allow pump to cool |
| Power/Current overload | Check length/size of power cable. Check or replace GFI |
| Impeller is blocked | Remove debris from the impeller chamber |
What can I do if my ATLANTIC TIDALWAVE L-310 pump has a diminished flow rate or no water flow?
If you notice a diminished flow rate or no water flow from your ATLANTIC TIDALWAVE L-310 pump, turn off the power before inspection. Consult the table below for possible causes and solutions:
| Possible Cause | Possible Solution |
|---|---|
| Air lock | Restart/Clean air valve |
| Obstruction in pump or piping | Clear obstruction |
| Piping is too long | Reduce length of pipe |