What are the installation steps for the AIRFLOW MAXAIR 7006A exhaust fan?

Please follow these steps to install your AIRFLOW MAXAIR 7006A exhaust fan:

1. Check the proposed location to ensure it will not foul joists, existing wiring, or other internal wall features. The wall thickness must be between 110mm and 310mm. Use the provided template to mark out the hole and cut a 180mm diameter hole through the wall.

2. Screw the fan assembly to the wall via the four corner openings. Use appropriate fasteners for your wall type (fasteners not provided).

3. Remove the termination cover by undoing the three marked screws. Retain these screws for reassembly.

4. An electrician must make the electrical connection (see wiring instructions). Once complete, replace the termination cover.

5. With the fan assembly mounted, cut the included PVC sheet to suit the depth of your wall.

6. Coil the cut PVC sheet around the wall grille outlet spigot and slide it into the retaining clips on the fan assembly.

7. Screw the wall grille outlet to the external wall. The PVC sheet should overlap the duct by approximately 20mm. Use appropriate fasteners (not provided).

8. Place the main cover assembly onto the fan unit as shown, and tighten the retaining screw. Test the fan to ensure it is ready to go.


How should the electrical connections be made for the AIRFLOW MAXAIR 7006A?

A licensed electrician must make the electrical connection. Use a three-core, 1mm² cable and follow the 7006A Connection Diagram provided in the instructions.

The connection points are:

• A/P

• N

• Earth (Green/Yellow)

• 1

The fan connects to an external isolating switch and features an internal auto switch.


How does the shutter on the AIRFLOW MAXAIR 7006A operate?

The AIRFLOW MAXAIR 7006A features automatic shutter operation. There is an approximately 60-second delay when opening and up to a three-minute delay when closing the shutters. This design ensures silent operation.


What preparation is needed before replacing the outer cover on the AIRFLOW MAXAIR 7006A?

Before replacing the outer cover on the AIRFLOW MAXAIR 7006A Automatic Model, you must ensure the unit has been switched “off” for at least five minutes. After five minutes, return the shutter lever to its lowest position. You can then proceed with replacing the cover.


What are the safety warnings for the AIRFLOW MAXAIR 7006A?

Please observe the following warnings:

• This appliance is not intended for use by young children or infirm persons, unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely, and to ensure that they do not play with the appliance.

• The appliance is intended for installation through external walls only.

• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons, in order to avoid a hazard.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD AIRFLOW MAXAIR 7006A (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.