****** Page 1 ****** Excerpts from Original instructions Magne 3 and 4 Electromagnetic process lock Complete Product Manual [EN] found at: abb.com/lowvoltage Product description Magne is an electromagnetic process lock that locks a door or a hatch and is intended for applications that are sensitive to unintentional or unnecessary interruptions. Magne has a holding force of up to 1500 N. Magne can be installed on a door, preferably using an ABB mounting kit, available for sliding doors or hinged (conventional) doors. Magne 3 keeps a door locked. If used in safety applications, Magne 3 needs to be complemented with an external interlocking device. Magne 4 has an integrated Adam sensor which provides an interlocking function together with an Eva actuator. The Eva actuator is ordered and installed separately. Magne 4 is available with integrated Adam DYN (DYNIink signal) or Adam OSSD (OSSD signal) using M12 5-pole or M12 8-pole connector. Anchor plates are delivered with a cellular rubber. Anchor plate 32E has an integrated permanent magnet. Anchor plate 32D is without a magnet. Y-connectors and other accessories are available to facilitate connection in series. 1. 2. 3. 4. 5. 6. 7. 8. Install Magne and accessories as close to the door handle as possible. use relevant mounting kit and follow the installation guide included in the kit. Installation tolerances for Magne 3 and JSM D23C on a sliding door. x A. B. C. D. E. z X. Y. Z. Magne Anchor plate Cellular rubber Sliding door Fence 60 mm 69 mm ±5 18 mm ±5 B c Anchor plate (B) is installed with cellular rubber (C) between the anchor plate and the bracket (G) mounted on the door. The cellular rubber is attached to the anchor plate with adhesive tape and enables the anchor plate to adjust to Magne. Use suitable M8 screw (F). Recommended tightening torque is 7 Nm ±2. O Note! Do not compress the cellular rubber to a thickness less than 8 mm. Do not overtighten the screw. This can deform the anchor plate, causing reduced or no holding force. c Connections Magne 3X M12 5-pole connector 1) Brown: Locking signal +24 VDC 2) White: Not used 3) Blue: a v 4) Black: Nat used 5) Grey: Info output, locked Magne 4 DYN-21nfo M12 8-pole connector 1) White: DYNIink signal in 2) Brown: +24 VDC 3) Green: Locking signal +24 VDC 4) Yellow: O V 5) Grey: Info output (Adam and Eva closed) 6) Pink: DYNIink signal out 7) Blue: OV 8) Red: Info output (Locked) Safety precautions Magne 4X DYN i M12 5-pole connector 1) arown: +24 VDC 2) White: DYNIink signal in 3) Blue: OV 4) Black: DYNIink signal out 5) Grey: Lacking signal +24 VDC Magne 4 OSSD-lnfo 8 M12 8-pole connector 1) White: OSSDI out 2) Brown: +24 VDC 3) Green: ossol in 4) Yellow: OSSD2 in 5) Grey: Info output (Adam and Eva closed & Magne locked) 6) Pink: OSSD2 out 7) Blue: O V 8) Red: Locking signal +24 VDC Magne 4 DYN-lnfo Make sure the surfaces of the electromagnet (A) and the anchor plate (B) are S 8 completely parallel, i.e. that full contact is obtained when the door is closed. Installation tolerances: X. ±3 mm sideways Y. ±5 mm lengthways x M12 8-pole connector 1) White: DYNIink signal in 2) Brown: +24 VDC 3) Green: Locking signal +24 VDC 4) Yellow: O V 5) Grey: Infa output (Adam and Eva closed & Magne locked) 6) Pink: DYNIink signal out 7) Blue: OV 8) Red: Not used Warning! Always use shielded cables ta connect the unit to the rest of the safety circuit. Warning! The info output is non-failsafe and shall never be used to control a safety application. Warning! The DYNIink signal or OSSO signals are used to control the safety application. n Note! Several Magne 3X units can be connected using a M12-3A Y-connector ar several Magne 4 OSSD-lnfo using a M12-3G Y- connector, but the info-signal will not be available. Several Magne 4X DYN units can be connected using a M12-3S Y-conector. The safety functionality of Magne 4 is based on the integrated Adam sensor and the Eva actuator. Eva unit (A) must be correctly positioned above the yellow cover on Magne/Adam (B) when the door is closed. Positioning tolerances: X. ±5 mm sideways Y. ±5 mm lengthways Z. 2-7 mm O Note! For the sensor to work as x z Warning! Carefully read through the entire product manual before using the device. Warning! The devices shall be installed by authorized personnel following the Safety regulations, standards and the Machinery directive. Warning! Failure to comply with instructions, operation that is not in accordance with the use prescribed in the instructions, improper installation or handling of the device can affect the safety of people and the plant. Installation Installation shall be done in accordance with a risk assessment for the individual application. Warning! All safety functions shall be tested before starting up the system. Warning! Do not defeat, tamper or bypass the safety function. Failure can result in death or serious injury. Warning! The M12 connector shall be connected after Magne has been installed on the intended surface. ! Caution! Magne shall be installed as close to the door handle as possible. The distance between the lock and the handle creates a lever effect, reducing the holding force. intended it is very important that the units are correctly positioned and that the safety functions are tested. Connect the pin out according to chapter ‘Connections’. Connect the M12 connector to Magne. O Note! Make sure no power supply is connected when cable is fitted to the Magne M12 pin out. Close the door to put Eva within sensing distance of Adam. Connect Magne to the power supply and turn power on. o Note! Only connect Magne to power supply when Eva is within sensing distance. The integrated Adam sensor in Magne 4 needs to learn the Eva code. For Magne 3 the blue LED will illuminate with a solid light when connected. For Magne 4 the green LED will illuminate with a solid light. The blue LED will illuminate with a solid light when the locking signal is activated. After installation, check the locking function. o Caution! After installation, check the locking function and that the surfaces of the magnet and the anchor plate are parallel, i.e. that full contact is obtained when the door is closed. If the anchor plate tilts, the holding force of the lock can be significantly reduced or eliminated.

****** Page 2 ****** Maintenance Warning! The safety functions and the mechanics shall be tested regularly. Check correct operation of all circuits and the locking function at least once a year. Warning! A defective unit shall be replaced with a new unit. Never bypass the safety circuit. Warning! In case of breakdown or damage to the product, contact nearest ABB Electrification Sweden service office or reseller. Do not try to repair the product yourself. Warning! ABB will not accept responsibility for failure of the switch functions if the installation and maintenance requirements shown in this document are not implemented. O Caution! The electromagnet shall be regularly cleaned to maintain its full holding force. Dirt or dust on the anchor plate or Magne can cause low or no holding force. Instructions regarding ‘Testing safety function’ and ‘Replacing Eva unit’ can be found in the complete ‘Magne 3 and 4 Product Manual’ available on web. LED indications Model Magne 3 + Magne 4 Magne 3 + Magne 4 Magne 4 Magne 4 Magne 4 Magne 4 Magne 4 Magne 4 Magne 4 (OSSD) Troubleshooting LED Indication Blue Blue flashing Green Green flashing Green-Red flashing Red Red flashing Red fast flashing Red-Red-Green fast flashing Description Magne is locked Lock signal, but Magne is not detecting the anchor plate Eva within sensing distance of Adam (door closed) Eva within 2 mm from maximum sensing distance (door closed) Eva within sensing distance, safety circuit before this unit broken (door closed) Eva out of sensing distance (door open) Eva code not stored in Adam Fail safe mode Invalid input signal Safety circuit N/A N/A Closed Closed Open Open Open Open Open Current consumption Information output Cable dimension Connector Safet / Harmonized standards Conformity Application standard compliance Functional safety standard compliance A Warning! Electrical safety standard compliance Electromagnetic compatibility standard compliance Certifications +24 VDC: Magne 3: 10 mA, Magne 4: 50 mA Note! Any current drawn an outputs (e.g. the information output) will be an additional input current on +24 VDC. Locking signal: Nominal: 250 mA at 24 max. 350 mA at 27.6 VDC Max. 20 mA Cable dimensioning should be checked when connecting several units in series. Standard cables from ABB have a cross sectional area of 0.34 mm . Magne does not cause any power surge when locking is activated. M12 5-pole male connector (Magne 3X, Magne 4X DYN) M12 8-pole male connector (Magne 4 DYN-lnfo, Magne 4 DYN-21nfo and Magne 4 OSSD-lnfo) European Machinery Directive 2006/42/EC EMC directive 2014/30/EU RoHS directive 2011/65/EU RoHS3 directive 2015/863 EN ISO 14119:2013 EN ISO 12100:2010 EN ISO 13849-1:2015, PL e/Category 4, PFHo- EN ISO 13849-2:2012 EN SIL3, PFHD EN 61508:2010, SIL3, PFHo= 4.50110 s The safety related values are based on interlocking de,nce Eden and are not valid for the locking function. EN 60204-1:2006 + A1:2009 EN 60664-1:2007 EN EN 60947-5-3:2013 clJLus, TUV srad Information for use in USA/Canada (UL) Enclosure Intended usage Connecting cables Power source Conductor area LED Indication No LED light Blue flashing Magne 4: Green flashing Red solid light Green and Red at the same time Green-Red fast flashing Red fast flashing Green-Red flashing Red-Red-Green fast flashing (OSSD only) Probable cause No voltage Anchor plate is missing or not centered Eva within 2 mm from maximum sensing distance Eva out of sensing distance, safety circuit broken (door open) Metal between Adam and Eva Unit is defective Valid Eva code missing Fail safe mode Input signal is missing Invalid input signal Action Check +24 VDC power supply. Check anchor plate position. Adjust Eva position. Move Eva within sensing distance of Adam (close door). Remove metal. Replace the unit. Perform procedure to replace Eva. If fault indication remains, the unit is defective and must be replaced. Power cycle (i.e.turn off pawer, wait for one minute and turn it on again). 1. Check output signal from the previous unit in the signal chain. 2. Turn off power supply. 3. Move Eva within sensing distance of Adam. 4. Power supply. Power cycle (i.e. turn off the power, wait for one minute and turn it an again). If fault indication remains, check incoming signals. Type 1 Applications according to NFPA 79 Cables to comply with CYJV/7, with a conductor area of min. 2 0.2 mm The Limited Voltage / Current source must comply with one of the following: A) An isolating device such that the maximum open circuit voltage potential available to the circuit is not more than 30 VDC and the current is limited to a value not exceeding 8 amperes measured after one minute of operation. B) A suitable isolating source in conjunction With a fuse in accordance With UL248. The fuse shall be rated max. 3 A and be installed in the 30 VDC power supply to the device in order to limit the available current. Max. current limit for overload protection: AWG (mrnZ) Amps 24 22 20 18 Further information regarding the interlock switch can be found in ‘Eden Product Manual’ available on web. Descriptions and examples show how the product works and can be used. It does not mean that it fulfills the requirements for all types of machines and processes. The buyer/user is responsible for installing and using the product according to applicable standards and regulations. We reserve the right to make changes to the product and the documentation without prior notice. 2TLC010056M0201 Rev.M3 Technical data Manufacturer Address Mechanical data Anchor plate material Electromagnet material Housing material Potting material PCB coating material Enclosure protection Ambient temperature Holding force Humidity Weight Electrical data Operating voltage ABB Electrification Sweden AB SE-721 61 Västerås Sweden Iron With nickel coating Iron With zink coating Anodized aluminum and polycarbonate PUR, epoxy SEPUR 540RT IP67 Operating temperature: -20 oc to +50 oc Storage temperature: -20 oc to +70 oc Up to 1500 N (on correct installation) Anchor plate permanent magnet 32E holding force: 30 N 35-85 % (without ice formation or condensation) Magne 3, Magne 4: 700 g Anchor plate 32D/32E: 290 g Electromagnet +24 VDC ±15 %


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL

ABB MAGNE 4 (01) PDF MANUAL

Leave a Reply

This site uses Akismet to reduce spam. Learn how your comment data is processed.