ZEPHYR AK2000 (01) PDF SUMMARY:
How do you set the clock?
Press “clock”. The Hour Indicator will flash, indicating the clock setting function is ready. Press “hr” to set hours (from 1-12). Press “min” to set minutes (from 00-59). Let the clock flash for 7 seconds, and the new time input will automatically be stored.
How do you turn the light on and off?
Press the “light” button once to turn the light on. Press again to turn it off.
How do you turn the light and both blowers on high speed?
You can simultaneously turn on the light and both blowers on high speed by simply pressing “On/Off” once.
How do you select blowers and speed?
During the time the light and both blowers are on high speed, you can select blowers and speed by pressing the “Fan-L” and “Fan-R” button.
How do you turn the blower off on the selected side?
The third press on the “Fan-L” and “Fan-R” button will turn the blower off on the selected side (as the indicator light turns off). You can also turn individual blowers On/Off and select speed by simply pressing the desired “Fan-L” or “Fan-R” button.
How do you turn all operations off?
Press “On/Off” again, and all operations will stop.
How do you use the Timed Delay Off feature while the blowers are in operation?
Pressing the “Delay Off” button once will set the unit to turn off in 3 minutes. Press again for the preset 5 minutes countdown and the third press for 10 minutes. Once a desired time is selected, the countdown will start as the delay off indicator light flashes. All operations will cease as the countdown reaches zero.
What happens when the delay function is selected?
At any time when the delay function is selected, the light will turn off automatically, and all blowers will decelerate to low speed.
How do you set the timer (alarm)?
Press the “hr” and “min” buttons to set the desired timer countdown. Once the timer is set, the countdown will start in 7 seconds as the delay indicator light flashes.
What happens when the countdown reaches zero?
When the countdown reaches 0, 10 short beeps will sound. To cancel the timer after setting, press the “On/Off” button to terminate all operations and restart.
Can the timer function be operated simultaneously with the “Delay Off” function?
No, the timer function cannot be operated simultaneously with the “Delay Off” function. Nevertheless, setting the timer function will not affect any other operations.
What are the rocker controls?
- (1) Light- turns light On/Off.
- (2) (3) Blower Controls- Independently controls Right and Left blowers. Rock switch up (I) for low speed, (II) for high speed, and center (.) to turn off.
What is the Self Clean Feature?
All Zephyr Range Hoods are filter-less and are designed with a self-clean feature. The centrifugal blower system automatically liquefies grease accumulated in its internal housing. All systems are equipped with dishwasher safe grease containers for their self-clean function. Grease and residue from cooking are often automatically liquefied and can accumulate in the containers from everyday use. Nevertheless, grease from cooking could also dry and adhere to its internal housing. Running the self-clean function periodically will flush out the accumulated grease in the range hood’s internal housing.
How often should you clean the range hood?
Cleaning should be approximately once a month under normal use.
What detergent is recommended for cleaning the range hood?
Grease-cutting detergent such as ‘409’ or its equivalent is recommended.
How do you clean the safety grill?
Remove both safety grills for cleaning by simply loosening Philips screws. Clean safety grills in the dishwasher under the normal wash cycle.
What warning should you be aware of when cleaning the safety grill?
Use with extreme caution as both safety grills are removed. Beware of blowers catching onto hair, loose clothing, and fingers. NEVER leave children unattended.
How do you turn on the blowers for self-cleaning?
Turn both blowers on low speed for cleaning.
How do you self-clean a Hurricane series range hood?
Simply set Timed Delay Off to 5 minutes.
How do you clean the light shield on a Hurricane series range hood?
Remove the light shield by turning it counter-clockwise. Clean in the dishwasher under the normal wash cycle.
How do you clean the light shield on a Whirlwind series range hood?
Remove the light shield by unscrewing the Philips screw. Clean in the dishwasher under the normal wash cycle.
What is a cleaning tip for the residue containers?
Fill residue containers ¼ full with water before cleaning or during regular use. This will help to prevent grease from drying and tacking on the cup surface.
What is a warning for cleaning the edges of the stainless steel surface?
Edges on the stainless steel surface are exposed once the shield is removed. Clean around edges with extreme care, and the use of latex cleaning gloves is recommended.
How do you use the self-clean feature with ‘409’ detergent?
With the nozzle on ‘spray’, squirt ‘409’ detergent directly onto the blower blades 30-35 times. Repeat with the second blower. Allow self-cleaning to run for 5 minutes before switching off. (If desired, spray water to rinse off detergent after completion of the cleaning cycle and run for another few minutes).
How do you clean the residue containers?
Remove residue containers by gently sliding out with both hands. Clean in the dishwasher under the normal wash cycle.
Do the QuattroVent Air-Curtain channels need to be cleaned after the self-clean is completed?
No, the QuattroVent Air-Curtain channels are adjoined to its two main blowers and share the same internal housing. No further cleaning is required after the self-clean is completed. Clean residue around the channels surface with ‘409’ and a cotton cloth regularly.
How do you replace the lights?
All light bulbs included are 40W appliance bulbs. Replace with 60W bulbs if brighter illumination is desired. Remove the light shield according to instructions on page 6.
What is the warning for replacing the lights?
Edges on stainless steel surface are exposed once shield is removed. Replace bulb through opening with extreme care. Wearing latex gloves is recommended.
How do you clean the range hood surface?
Clean all surface residue with ‘409’ or mild detergent and wipe with a cotton cloth. The stainless steel surface could further be polished with any stainless steel polish or glass cleaners.
Who should install this product?
Installation of this product is intended for qualified installers, service technicians, or persons with similar qualified backgrounds. DO NOT attempt to install this appliance yourself. Injury could result from installing the unit due to a lack of appropriate electrical knowledge and technical background. Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage, and the warranty on the product automatically becomes void.
What codes must the installation of this product conform with?
Installation of this product must conform with all local codes. All connections must be electrically grounded, and ducting must be properly vented outside in accordance with codes. Never duct exhaust into attics, within walls, crawl spaces, garages, or anywhere inside the house which might cause a grease fire. All duct joints must be properly inspected, taped, and sealed.
What safety precautions should be taken when handling the range hood?
Edges are exposed around the duct opening and once the bottom grease shield is removed. Be careful when handling the sharp edges. Wearing protective gloves and appropriate work clothing is recommended.
What is the duct size for the Hurricane series?
6“ Vertical Duct Discharge
What is the duct size for the Whirlwind series?
6“ Vertical Duct Discharge
What is the duct size for the Cyclone series?
- 6“ Vertical Duct Discharge
- 3-1/4 x 10“ Vertical Duct Discharge
- 3-1/4 x 10“ Horizontal Rear Discharge
What accessories are included with the Hurricane & Whirlwind series?
- 2 residue cups
- 2 ‘L’ brackets (for direct wall mount only)
- 4 screws for ‘L’ brackets
- 1 6“ starting collar
- 3 electrical wire connectors & screws
What accessories are included with the Cyclone series?
- 2 residue cups
- 2 ‘L’ brackets (for direct wall mount only)
- 4 screws for ‘L’ brackets
- 1 6“ starting collar
- 3 electrical wire connectors & screws
- 1 Convertible transition collar
- 1 6“ collar cap
- 1 3-1/4 x 10“ starting collar (packaged separately)
- 1 Back-splash
What should you check before installation?
Check all accessories before installation. Packaging also includes:
-
- Care, Maintenance and installation manual
-
- Owner’s Warranty Registration Card
-
- Serial number label adhered on top of the box.
What tools are required for installation?
- Hand Drill with #2 philips
- Flat head screwdriver to pry electrical knockout
- 3/4“ Wood Boring Bit
- Jigsaw (if cabinet opening modification is required)
What is the power source?
115W
What is the minimum and maximum clearance above the range?
Minimum clearance above the range should be no less than 18“ from the range surface to the range hood’s base. The maximum height is recommended not to exceed 30” for maximum efficiency.
What is the net width on all models?
Net width on all models is called out width less 1/4”.
What should you refer to for height clearance requirements on all high btu and professional ranges?
Refer to Manufacturers’ height clearance requirements on all high btu and professional ranges.
What are the callout sizes and net widths?
| Call Out Size | Net Width |
|---|---|
| 30“ | 29-3/4” |
| 36“ | 35-3/4” |
| 42“ | 41-3/4” |
| 48“ | 47-3/4” |
What is the cut out size (A) for the Hurricane?
10-1/2“
What is the cut out size (A) for the Cyclone?
10-1/2”
What is the cut out size (A) for the Whirlwind?
8-1/2”
What is Step 1 of the installation process?
- Remove all contents from the box.
- Unscrew and remove the bottom grease splash shield.
What is Step 2 of the installation process?
- Locate electrical connection box knock out from the left rear of the hood and pry open with a screwdriver.
- Locate the electrical connection box inside.
- Unscrew the cover to reveal wiring.
What is Step 3 of the installation process?
- Cut out the cabinet base opening if necessary. Refer to cut-out dimensions on the previous page.
- Reinforce the cabinet base with 1×2 wood strips if additional strengthening is required.
- Unscrew and remove the bottom grease splash shield.
What is Step 4 of the installation process?
Install a damper if required by local codes (not provided) or install a 6“ starting collar (green).
What is Step 5 of the installation process?
- Drill out the cabinet base through the electrical box with a 3/4" boring bit.
- Pull the electrical supply wire through drill out or use #14 grounded wire for receptacles (not supplied).
What is Step 6 of the installation process?
Connect both wires (blk) on the hood to either power supply (blk or wht). Ground the green wire.
What is Step 7 of the installation process?
- Lift the hood to the bottom of the cabinet.
- Support the hood in place, fasten both rear with screws and washers provided.
What is Step 8 of the installation process?
- Fasten the front of the hood. Level all sides and adjust accordingly.
- Next, fasten the 3 front screws and begin tightening all screws from rear to front.
What is Step 9 of the installation process?
Connect the duct to the opening, inspect and tape all joints with approved aluminum or duct tape.
What is Step 10 of the installation process?
On Cyclone & Whirlwind models, be sure to pull both grease tubes over its opening.
What is Step 11 of the installation process?
Reinstall the bottom splash shield by first fastening 3 rear screws (do not tighten all the way).
What is Step 12 of the installation process?
Turn on the electrical supply or plug into receptacles.
What is Step 13 of the installation process?
Reinstall the electrical box cover.
How do you convert to a 3-1/4 x 10“ Vertical Discharge?
- Remove the pre-mounted 6“ transition adaptor on the duct opening. Leave the attached gasket in its original place.
- Place the rectangular transition adaptor as shown over the gasket and by first installing 4 screws on the half-round section.
- Mount the 3-1/4 x 10“ starting collar on top of the transition piece with the remaining screws.
Which Zephyr series are equipped with a 6“ vertical discharge, 3-1/4×10” vertical discharge, or 3-1/4×10” rear discharge?
Zephyr’s Cyclone series: AK6000, 6036, 6042, 6048
What is included with Cyclone models?
Cyclone models also come with a standard backsplash. If desired, install the backsplash to the rear of the range hood with screws provided after all duct conversion steps below are completed.
What are the convertible options?
- Vertical discharge 6“ round
- Vertical discharge 3-1/4 x 10“
- Horizontal rear discharge 3-1/4 x 10”
What are the convertible accessories?
- 6“ round duct cap
- Round to rectangular transition adaptor
- Rectangular to round transition adaptor (pre-mounted)
- Gasket (pre-mounted)
- Rectangular rear cap (pre-mounted)
- 3-1/4 x 10“ starting collar
How do you convert to a 3-1/4 x 10“ Rear Discharge?
- At the rear of the range hood, remove all screws on the pre-mounted rear rectangular cap and remove the cap with the gasket.
- Remove the top pre-mounted transition piece. Leave the attached gasket in its original place.
- Mount the 3-1/4 x 10“ starting collar on top of the transition piece with the remaining screws.
- Remove 2 arch blocks through the top opening.
- Option 1: (for recessed cabinet base) Re-install originally pre-mounted round transition piece at opening with gasket. Cap opening with 6“ cap provided OR, use option 2 if the cabinet base is not recessed.
- Option 2: (for flush cabinet base) Mount the rectangular transition piece at opening with a gasket as shown. Mount the rectangular cap (previously removed) on top of the transition adaptor.
What should be done in Step 6 regarding a damper?
A damper (not included) should be installed to prevent backdraft where needed. A damper might also be required by local codes to qualify for building inspections. You can purchase dampers from most hardware stores or call the service line to order. When a damper is not installed, a starting collar is provided to increase and raise the duct opening clearance above the cabinet’s base. Snap the adaptor’s smaller end to the hood’s duct opening and secure by drilling 2 pilot holes and fasten with screws (as shown in step 6, page 10).
What should be done in Step 9 regarding the hood?
The hood should NEVER be installed so that the front is tilting downward. This will cause grease to backflow to the front instead of the rear. ALWAYS level the hood or slightly tilt the front of the hood upward. Some models include 2 pre-installed bumpers on the rear (or top) to aid the hood front tilt upward when installed. Remove the bumpers simply by peeling off if the hood is preferred to be installed leveled. (refer to the diagram).
What should be done in Step 12 regarding the electrical wiring?
A connector locking the electrical wiring on the electrical box is recommended and might be required by local codes. Check with local inspectors, purchase and install the appropriate connector to meet all mandatory codes. Call the service line to order the connector.
What should you do if upon completion of installation, nothing works?
Check if the unit has been plugged in, make sure that all power has been turned back on and all electrical wiring is properly connected.
What should you do if the light is on, but the blowers are not turning at all or seem to be scraping on something?
The blower blade unit might have been mounted too low and scraping the bottom or jammed. Loosen the hex screw on the blade unit and adjust to the proper height.
What should you do if when the blowers are on, something seems to be loose and spinning around inside?
There might have been foreign particles left within the discharge opening or rocks, leaves, branches, etc. that might have fallen in from old ductwork. Disconnect ductwork to inspect and remove any foreign particles.
What should you do if there is vibration when the blowers are on?
The unit might not have been secured properly on the cabinet. Or the cabinet might need to be further secured into studs on the wall.
What should you do about blower noise?
The blowers are designed to perform up to 695 cfm. A properly functioning motor itself should be relatively quiet. Nevertheless, due to the vacuum created by the suction, noise levels up to 5.5 sones will be generated when both blower units are turned on at their maximum speed. Employ both blowers at maximum speed only when needed (heavy pan frying, wok cooking, etc.) Employing low speeds or a single blower will suffice moderate cooking such as steaming, broiling, etc.
What should you do if the light is not working?
The light bulb might need to be replaced. In some instances, the fragile bulb could have been damaged during the shipping process. Simply replace it with a 40 or 60W appliance bulb.
What should you do if no grease is collected in the residue containers?
Grease flow will vary by the amount, method, and type of cooking. If pan-frying is frequent accompanied by steaming, vapor from steam will liquefy accumulated grease in its internal housing and flow into the containers. No grease collected in the residue containers is normal until the self-clean function is completed. Clean blowers approximately once a month as instructed to avoid clogging.
What should you do if no grease is collected in the residue containers after self-cleaning?
Tubes connected to the internal housing might have been clogged due to a lack of cleaning. Or the hood might not have been leveled when installed. Unclog tubes or reinstall the hood (refer to page 16).
What should you do if the safety grill is dirty?
The self-clean feature cleans only the internal housing within the range hood. Remove the safety grill to clean it in the dishwasher and clean all surfaces periodically as instructed.
What should you do if the blowers seem weak?
Check the duct size used, duct size should be at least 6“ or 3-1/4 x 10”. The range hood WILL NOT function properly with an insufficient duct size. Check if the duct is clogged or if the damper unit is not opening properly. A tight mesh on a sidewall cap unit might also cause restriction to the airflow.
What should you do if cooking fumes and smoke dissipate before it reaches the blower?
- Use a damper-type sidewall cap.
- Reduce the number of elbows and the length of ductwork.
- Check if all joints are properly connected, sealed, and taped.
- Check if the unit is installed at the recommended height (page 9). The range hood should also be able to cover the entire cooking area from left to right and most areas from rear to front.
- Open doors and windows might also distract airflow before it reaches the blowers.
- Make sure blowers are on high speed for heavy cooking.
Who should you contact for other questions and further assistance?
For other questions and further assistance, please call the service department with the product’s registered serial number or write to:
ZEPHYR CORPORATION Service Department
1.888.880.VENT (8368) 415.282.1211 1551 Minnesota St., San Francisco, CA 94107
What is the One Year Service Repair Warranty?
For one year from the date of original purchase, Zephyr will provide, free of charge, service labor to repair any failed parts or components due to manufacturing defects.
What is the Ten Years Parts Warranty?
For ten years from the date of original purchase, Zephyr will provide, free of charge, non-consumable replacement parts or components that failed due to manufacturing defects. Consumable parts not covered by this warranty include: Light Bulbs, Metal and Charcoal Filters.
Who is covered under the warranty?
This warranty is extended to the original purchaser for products purchased for ordinary home use in the 48 mainland states, Hawaii, and Washington D.C. In Canada and Alaska, this warranty is Limited. There might be costs associated with shipping the products to designated service locations, or you might need to pay the service technician’s travel costs to have the appliance repaired in-home.
When will the warranty be voided?
This Warranty will be Voided when:
- Product damaged through negligence, misuse, abuse, accident.
- Improper installation and failure to follow installation instructions.
- When the product is used commercially or other than its intended purpose.
- Damaged because of improper connection with equipment of other manufacturers.
- Repaired or modified by anyone other than Zephyr’s Authorized Agents.
What is not covered under the warranty?
What is Not Covered:
- Consumable parts such as light bulbs, filters, and fuses.
- Services outside the service area and the labor cost incurred in connection with the removal, shipping and reinstallation cost, nor does it cover any other contingent expenses.
- The natural wear of finish, and wear due to improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven cleaner products.
- Chips, dents, or cracks due to abuse, misuse, freight damage, or improper installation.
- Service trips to your home to teach you how to use the product.
- Damage to the product caused by accident, fire, floods, or acts of God.
Where is the warranty valid?
This warranty is valid in the United States and Canada. It is non-transferable and applies only to the original purchaser and does not extend to subsequent owners of this product. Any applicable implied warranties, including the warranty of merchantability, are limited in duration to a period of express warranty as provided herein beginning with the date of original purchase at retail and, no warranties, whether express or implied, shall apply to this product thereafter.
What should you have ready for warranty issues?
Have your product proof of purchase with the date ready for warranty issues. Or write to:
Zephyr Corporation Service and Warranty Department 395 Mendell Street San Francisco, CA 94124
How do you obtain service under warranty?
To obtain service under warranty, you must present proof of the original purchase date. Please keep a copy of your dated proof of purchase (sales slip) to obtain service under warranty.
Who should you call to obtain service under warranty or for any service-related questions?
To obtain service under warranty or any Service-Related Questions, please call: 1-888-880-8368