PDF Content Summary: INSTALLATION GUIDEWarming Drawers

Contents Wolf Warming Drawers . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation Considerations . . . . . . . . . . . . . . . . . . . . . . 4 Warming Drawer Specifications . . . . . . . . . . . . . . . . . . 8 Warming Drawer Installation . . . . . . . . . . . . . . . . . . . 14 Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information. IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified. Important Note To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted information throughout this guide: IMPORTANT NOTE highlights information that is especially important. CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed. WARNING states a hazard that may cause serious injury or death if precautions are not followed.

Wolf Warming Drawers 3 wolfappliance.com/specs Warming Drawer Installation

IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf factory certified service. Read this entire installation guide prior to installation and save for the local inspector’s reference. The homeowner should keep this installation guide for future reference. IMPORTANT NOTE: The warming drawer must be installed with a Wolf stainless steel or integrated drawer front. This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedi cated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency and amperage ratings are listed on the product rating plate. Record the model and serial numbers before installing the warming drawer. Both numbers are listed on the product rating plate, located on the left front floor area of the inner cabinet. To access the rating plate, the drawer must be fully open. Refer to the illustration below. RATING PLATE Location of rating plate. Wolf Warming Drawer Model Number Serial Number

Installation Considerations 4 Installation Considerations

• The warming drawer must be installed with a Wolf stainless steel or integrated drawer front. Make sure you have the accessory drawer front called for in your installation. Specific installation instructions are included with the drawer front. • For all installations, the warming drawer must be fully enclosed, top and bottom. • The warming drawer platform must be able to support 200 lbs (90 kg). The platform must be a minimum of 1" (25) above the toe kick to allow for the warming drawer trim which overlaps 5/8" (16) on all four sides. • Check with local utilities for electrical codes that apply in your area. Local codes vary. Installation, electrical connections and grounding must comply with applica ble codes. In the absence of local codes, the drawer should be installed in accordance with National Electri cal Code ANSI/NFPA 70-1990 or latest edition. • Model WWD30O is CSA approved for outdoor installations. TOOLS AND MATERIALS REQUIRED • Minimum 3/4" (19) thick lumber for the solid platform that supports the warming drawer—must be able to support 200 lbs (90 kg). • Wood screws and hardware to install the platform. • Lumber for anti-tip block. • Power saw. • Level. • Drill and 1/16" bit, 1/2" bit also for integrated drawer front application. • Phillips screwdriver. • 2 wood screws (provided). • Wood cleats (optional).

Installation Considerations 5 wolfappliance.com/specs

Combination Installations Refer to the illustrations showing combination installations on pages 10–13. Also refer to installation instructions provided with the other Wolf products. • The warming drawer may be installed in combination with a Wolf built-in oven and/or microwave oven. Additional clearance between warming drawer and oven openings may be required. To allow the warming drawer trim and the oven trim to meet, a 7/8" (22) platform may be used to separate the two openings. This will act as the support platform for the oven and the anti-tip device for the warming drawer. An anti-tip block may be installed at the rear of the cabinet in place of the platform. If the warming drawer is installed above an oven, a 7/8" (22) platform is required to allow for clearance of overlaps. • The warming drawer may be installed below a Wolf cooktop or sealed burner rangetop. Allow enough room for gas and electrical connections for the cooktop. • The warming drawer may be installed next to or above another Wolf warming drawer. • Model WWD30O may be installed below a Wolf outdoor grill. Electrical Requirements The electrical supply should be located as shown in the illustration for your specific installation on the following pages. A separate circuit, servicing only this appliance is required. IMPORTANT NOTE: You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. If two warming drawers are installed side by side, they can operate from the same electrical outlet. A 30 amp circuit breaker is required for this installation. IMPORTANT NOTE: When installed outdoors, a ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock. Electrical Requirements Power Supply 120 V AC, 50/60 Hz Circuit Breaker 15 or 20 amp Receptacle 3-prong grounding-type

Installation Considerations 6 Drawer Front Options

IMPORTANT NOTE: The warming drawer must be installed with a Wolf stainless steel or integrated drawer front. Wolf stainless steel and integrated drawer fronts allow for many design options, but the warming drawer itself will be the same for all applications. When installing a Wolf warming drawer in combination with an L series or E series built-in oven, you may choose the stainless steel drawer front to match the trim and handle of your oven. The E series 2" (51) thick drawer front with pro handle, in 30" (762) and 36" (914) widths, is designed to be installed below a sealed burner rangetop or outdoor gas grill, so the panel aligns properly with the front of the rangetop or grill. Keep in mind, overall dimensions for the warming drawer remain the same, even though the drawer front may be wider to match a Wolf 36" (914) wide oven, sealed burner rangetop or outdoor grill. OVERALL DIMENSIONS 297/8" (759) OR 357/8" (911) 281/4" (718) 103/8" (264) 3/4" (19) 211/2" (546) B A B 3/4" (19) 223/4" (578) 9" (229)

Stainless Steel Drawer Front L SERIES A B Tubular Handle 7/8" (22) 31/2" (89) E SERIES A B Tubular Handle 11/8" (29) 31/2" (89) Pro Handle 11/8" (29) 31/2" (89) Pro Handle (2" thick) 21/8" (54) 41/2" (114) Dimensions may vary ± 1/8" (3). Integrated Drawer Front CUSTOM PANEL WHD Typical 297/8" (759) 103/8" (264) 3/4" (19) Installation Considerations 7 wolfappliance.com/specs Installation Options

STANDARD, RECESSED OR FLUSH INSET INSTALLATION The warming drawer with E series drawer front can be installed in a standard, recessed or flush inset application. For a standard installation, the drawer collar and front panel sit proud of the cabinet face frame. A recessed installation requires the cabinetry be recessed by 3/16" (5) so the collar is flush with the cabinet face frame but the drawer front will sit proud. A flush inset installation requires the drawer collar and front panel be recessed to be flush with surrounding cabinetry. Refer to illustrations on the following pages for minimum cabinet dimensions for your specific installation. INSTALL RECESSED CLEATS AND PLATFORM For a recessed or flush inset application, you will need to install a recessed platform and cleats into the opening. Proper recess of the platform and cleats is critical to the function and esthetics of the warming drawer installation. The depth of the platform may increase with the cabinet depth. Be sure to rigidly mount the platform so that it can support a minimum of 200 lbs (90 kg). Refer to the illustrations below. Mounting holes will need to be drilled in the back of the drawer front panel. Holes should be drilled on site to ensure proper fit and gaps are achieved. A drilling template is provide with the integrated drawer front. IMPORTANT NOTE: Be sure to finish the inside lip of the opening and the front face of the platform and cleats. These areas may be visible when the drawer is open. IMPORTANT NOTE: Be aware of the location of the mounting holes on the warming drawer frame to make sure screws used to attach the cleats do not interfere with screw holes for mounting the warming drawer.

TOP CLEAT PLATFORM SIDE CLEAT CLEATS AND PLATFORM RECESSED 3/16"(5) TOP CLEAT PLATFORM SIDE CLEAT CLEATS AND PLATFORM RECESSED 3/16"(5)

CABINETRY OPENING PLUS THICKNESS OF DECORATIVE PANEL CABINETRY OPENING

Recessed application. Flush inset application. Warming Drawer Specifications 8 Standard Installation L SERIES, E SERIES OR INTEGRATED DRAWER FRONT DIMENSION

ANTI-TIP BLOCK 91/8" (232) WILL VARY*

OPENING HEIGHT 103/8" (264) 231/2" 285/8" (727) OPENING WIDTH E PLATFORM 36" (914)

24"(610) min CABINET DEPTH FLOOR TO COUNTERTOP (597) TYPICAL

SIDE VIEW FRONT VIEW *Dimension must accommodate height of anti-tip block and drawer face overlap. NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. Warming Drawer Specifications 9 wolfappliance.com/specs Flush Inset Installation E SERIES OR INTEGRATED DRAWER FRONT TOP VIEW 24 (610) min FLUSH INSET 1" (25) DEPTH SIDE CLEATS DIMENSION

ANTI-TIP BLOCK 91/8" (232) WILL VARY* 107/8" (276) FLUSH INSET 7/8" (22) TOP AND SIDE CLEATS 285/8" (727)

OPENING HEIGHTE

HEIGHT 36" (914) 231/2" OPENING WIDTH 7/8" (22) PLATFORM 303/8"(772) E

FLOOR TO COUNTERTOP (597) TYPICAL FLUSH INSET WIDTH

SIDE VIEW FRONT VIEW *Dimension must accommodate height of anti-tip block and drawer face overlap. NOTE: Dimensions provided allow for 1/4" (6) reveal for proper air flow. Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. Warming Drawer Specifications 10 Standard Tower Installation INSTALLATION WITH MICROWAVE AND BUILT-IN OVEN 1"(25) min

24"(610) min OPENING DEPTH L SERIES 11/2"(38) min E SERIES 273/16" (691) MICROWAVE OPENING 281/2" (724) OVEN OPENING WIDTH E 4" (102)

PLATFORM* E E 5" (127) E 91/8" (232) 3/4" (19) min 285/8" (727) WARMING DRAWER OPENING WIDTH SIDE VIEW FRONT VIEW *Platform must support 250 lbs (113 kg). NOTE: Location of electrical supply within oven opening may require additional cabinet depth. Warming Drawer Specifications 11 wolfappliance.com/specs Flush Inset Tower Installation INSTALLATION WITH STANDARD MICROWAVE AND E SERIES OVEN TOP VIEW 243/4" (629) min FLUSH INSET 1" (25) DEPTH SIDE CLEATS 303/8" (772) min FLUSH INSET WIDTH 11/16" (17) TOP CLEAT

17" (432) OPENING HEIGHT 273/16" (691) OPENING HEIGHT 181/2" (470) FLUSH INSET HEIGHT 281/8" (714) min FLUSH INSET HEIGHT 271/2" (699) STANDARD MICROWAVE OPENING WIDTH 111/16" (43) PLATFORM 281/2" (724) E SERIES OVEN OPENING WIDTH E 4" 1" (25) SIDE CLEATS

91/8" (232) 105/8" 9/16" (14) PLATFORM* 285/8" (727) (102) E E 5" (127) E

OPENING HEIGHT (270) FLUSH INSET HEIGHT WARMING DRAWER OPENING WIDTH 1" (25) PLATFORM

SIDE VIEW FRONT VIEW *Platform must support 250 lbs (113 kg). NOTE: Location of electrical supply within oven opening may require additional cabinet depth. Dashed line represents profile of unit. Warming Drawer Specifications 12 Flush Inset Tower Installation INSTALLATION WITH CONVECTION MICROWAVE AND E SERIES OVEN TOP VIEW 243/4" (629) min FLUSH INSET 1" (25) DEPTH SIDE CLEATS 303/8" (772) min FLUSH INSET WIDTH 1/2" (13) TOP CLEAT

187/8" (479) OPENING HEIGHT 273/16" (691) OPENING HEIGHT 201/8" (511) FLUSH INSET HEIGHT 281/8" (714) min FLUSH INSET HEIGHT 271/2" (699) CONVECTION MICROWAVE OPENING WIDTH E 15/8" (41) PLATFORM 281/2" (724) E SERIES OVEN OPENING WIDTH 1" (25)

9/16" (14) 4" (102) SIDE CLEATS

91/8" (232) 105/8" PLATFORM* 285/8" (727) E E 5" (127) E

OPENING HEIGHT (270) FLUSH INSET HEIGHT WARMING DRAWER OPENING WIDTH 1" (25) PLATFORM

SIDE VIEW FRONT VIEW *Platform must support 250 lbs (113 kg). NOTE: Location of electrical supply within oven opening may require additional cabinet depth. Dashed line represents profile of unit. Warming Drawer Specifications 13 wolfappliance.com/specs Flush Inset Tower Installation INSTALLATION WITH DRAWER MICROWAVE AND E SERIES OVEN TOP VIEW

11/4" (32) FOR MICROWAVE 1" (25) FOR OVEN AND WARMING DRAWER 243/4" (629) min FLUSH INSET DEPTH SIDE CLEATS

273/16" (691) OPENING HEIGHT 281/8" (714) min FLUSH INSET HEIGHT 303/8" (772) min FLUSH INSET WIDTH 7/8"(22) TOP CLEAT 281/2" (724) E SERIES OVEN OPENING WIDTH 9/16" (14) 4" (102) 1" (25) SIDE CLEATS

143/4" (375) E 153/8" PLATFORM* 281/2" (724) E E 5" (127) OPENING HEIGHT 91/8" (232) OPENING HEIGHT (391) FLUSH INSET HEIGHT 105/8" (270) FLUSH INSET HEIGHT DRAWER MICROWAVE OPENING WIDTH 5/8" (16) PLATFORM 285/8" (727) WARMING DRAWER OPENING WIDTH 1" (25) PLATFORM E

SIDE VIEW FRONT VIEW *Platform must support 250 lbs (113 kg. NOTE: Location of electrical supply within oven opening may require additional cabinet depth. Dashed line represents profile of unit. Warming Drawer Installation 14

Anti-Tip Block INSTALL ANTI-TIP BLOCKING Install an anti-tip block against the rear cabinet wall. When the warming drawer is installed below a built-in oven, you may use a 7/8" (22) thick platform to allow the warming drawer trim and the oven trim to meet. The platform will act as an anti-tip device for the warming drawer. An anti-tip block or platform must be installed to prevent the warming drawer from tipping forward while opened when loaded. Failure to do so could result in personal injury and damage to the cabinet. Install the Warming Drawer Unpack the warming drawer on a flat surface. Remove all packaging materials from inside the warming drawer. Do not discard the package containing the two wood screws needed for installation. Turn power off to the electrical outlet. Slide the left corner of the warming drawer into the opening. If the electrical outlet is installed inside the opening, plug the power cord into the outlet. The excess cord should be coiled behind or beside the unit. If the outlet is located in an adjacent cabinet, thread the power cord through the hole in the cabinet wall. Push the drawer back into the opening until the trim meets the cabinet front. Make sure the power cord does not get trapped under the warming drawer. IMPORTANT NOTE: Do not lift up on the handle to push the drawer into place. Open the warming drawer to its full extension. Drill pilot holes in each side hole, located toward the front on each side of the warming drawer. Install the wood screws provided with the unit. Refer to the illustration below. Turn power back on to the electrical outlet. LOCATION OF SIDE HOLE Location of side hole.

Service Information 15 wolfappliance.com/specs

Troubleshooting IMPORTANT NOTE: If the warming drawer does not operate properly, follow these troubleshooting steps: • Verify that electrical power is being supplied to the warming drawer. • Check electrical connections to ensure that the instal lation has been completed correctly. • Refer to the troubleshooting guide in the Wolf warming drawers use & care guide. • If the warming drawer still does not operate properly, contact Wolf factory certified service. Do not attempt to repair the warming drawer yourself. Wolf is not responsible for service required to correct a faulty installation. Service Information If service is necessary, maintain the quality built into your warming drawer by contacting Wolf factory certified service. For the name and number of Wolf factory certified service nearest you, check the contact & support section of our website, wolfappliance.com or call Wolf customer service at 800-222-7820. When calling for service, you will need the model and serial numbers of the warming drawer. Both numbers are listed on the product rating plate, located on the left front floor area of the inner cabinet. To access the rating plate, the drawer must be fully open. Refer to the illustration below. RATING PLATE Location of rating plate.

The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. ©Wolf Appliance, Inc. all rights reserved. Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc. Sub-Zero, Sub-Zero & Design, Dual Refrigeration, Constant Care and The Living Kitchen are registered trademarks and service marks of Sub-Zero, Inc. (collectively, the “Company Marks.”) All other trademarks or registered trademarks are property of their respective owners in the United States and other countries. WOLF APPLIANCE, INC. P. O. BOX 44848 MADISON, WI 53744 WOLFAPPLIANCE.COM 800.222.7820 816978 REV-A 1/2011