Free English WILLIAMS-SONOMA MAV219 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD WILLIAMS-SONOMA MAV219 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How do I open the locking case of my WILLIAMS-SONOMA MAV219?

The WILLIAMS-SONOMA MAV219 has a locking case with tabs that hold it closed while stored. To open it, simply grasp the battery compartment of the receiver and pull out. You will hear a click, and the unit will separate.


How do I perform the initial setup for my WILLIAMS-SONOMA MAV219 to use it as a thermometer?

To register the base unit with the remote unit (the one with the display), please do the following:

• Turn the unit on by holding the MODE button on the receiver unit until you hear the BEEP sound.

• Plug in the stainless steel probe into the transmitter unit. This must be done within 120 seconds of turning the unit on.

• The unit should beep three times when turned on and the probe temperature should appear within 5-10 seconds of plugging in the probe. When the temperature appears the unit will beep once.

• If this does not happen repeat the process.

Note: The probe must be plugged into the transmitter for the unit to work.


How do I switch between the thermometer and timer functions on the WILLIAMS-SONOMA MAV219?

Once the unit is on, press the MODE button again to change the unit from the thermometer function to the timer function. This button will change the feature of timer/thermometer back and forth.


What should I do if the signal is lost on my WILLIAMS-SONOMA MAV219?

The receiver unit will normally work within 150 feet of the transmitter. If the receiver is taken out of range or there is abnormal external interference, it may not be able to receive the transmission. If this happens, the unit will alert you by beeping once every 3 seconds to tell you to re-sync the signal. If this happens, you need to move the receiver unit close to the transmitter and follow the re-sync instructions.


How do I re-sync the signal on my WILLIAMS-SONOMA MAV219 if it was turned off and on?

If the receiver unit is turned off and then on and the signal is lost, do the following:

• Turn the receiver on by pressing the MODE button for two seconds.

• Once the unit is on hold the CLEAR button for several seconds until the probe temperature starts to blink with the — showing.

• Press and hold the (TX) button inside the battery compartment of the transmitter or re-plug the temperature probe. This has to be done within 120 seconds of turning the unit on.

• If the unit registers the transmitter the unit will beep and show the probe temperature. If it does not register press and hold the (TX) button again.


What are the pre-set meat temperatures for the WILLIAMS-SONOMA MAV219?

The unit is programmed with selected pre-set temperatures for all types of meats, recommended by major cookbooks and the USDA for food safety. The chart of the selected temperatures is as follows:

MEAT TASTE
Type WELL DONE MEDIUM MEDIUM RARE RARE
Beef BEEF 160°F 145°F 135°F 125°F
Veal VEAL 160°F 145°F N/A 135°F
Lamb LAMB 160°F 145°F 135°F 125°F
Pork PORK 160°F 145°F N/A N/A
Chicken, whole CHICK 165°F N/A N/A N/A
Turkey, whole TURKY 165°F N/A N/A N/A

How do I select a specific type of meat on the WILLIAMS-SONOMA MAV219?

To select a specific type of meat, press the button marked “MEAT” and scroll through the selections until the type of meat (e.g., BEEF, VEAL, CHICKEN) shows on the LCD display. The meat icon will also be shown on the display.


Can I customize the temperature setting on my WILLIAMS-SONOMA MAV219?

Yes. Once you have selected a temperature and food selection (for instance BEEF – RARE), you can customize the temperature setting by using the HR/▲ sign to increase the temperature setting or the MIN/▼ to reduce the temperature setting.


How do the alerts on the WILLIAMS-SONOMA MAV219 work?

Pre-Alert: When the probe temperature reaches ten degrees below the set temperature of your food, the unit will let you know with the voice alert “Your food is almost ready” and the unit will beep twice. The pre-alert will be repeated after four seconds.

Alert: When the probe temperature reaches the set temperature, the unit will beep three times and the voice will say “Your food is ready”. At the same time, the alert icon will flash on the face of the unit. To cancel the alert, press the STOP button on the unit.


How do I use the timer function on the WILLIAMS-SONOMA MAV219?

First, press the MODE button to switch the unit from the Thermometer setting to the Timer setting. If the timer is already running, press the CLEAR button so that the timer shows 0:00.

COUNT UP: To use as a count-up timer, simply press START. The timer will count up to a maximum of 23:59:59.

COUNT DOWN: To use as a count-down timer, set the hour time by pressing the HOUR▲ to the proper hour. To set the MINUTE, press the MIN▼ to the desired number of minutes. Once the hours and minutes are set, press START. The unit will count down to 0 and then beep for 20 seconds, and the icons will beep.


Can I use the timer and thermometer functions at the same time on my WILLIAMS-SONOMA MAV219?

Yes, the timer can be used while the thermometer is also in use. It will run in the background and can be viewed by pressing the MODE button to switch back from thermometer to timer.


How should I store my WILLIAMS-SONOMA MAV219?

The receiver can stand on the transmitter base. If you do not want to use the grill thermometer, put the receiver and transmitter face to face to combine them as a box for easy storage.


What should I do if my WILLIAMS-SONOMA MAV219 displays “LLL” or “HHH”?

If the receiver and/or the transmitter display LLL or HHH instead of the probe temperature, wait for the probe to reach room temperature. If LLL or HHH is still displayed, it is likely the internal probe wire has shorted out either through moisture or heat damage.

The Remote Thermometer registers temperatures as low as 14°F (-10°C) and as high as 482°F (250°C). LLL will be displayed below 14°F and HHH will be displayed above 482°F.


What are some helpful tips for using the probe of the WILLIAMS-SONOMA MAV219?

• Do not immerse the probe in water while cleaning.

• Do not allow the probe or probe wire to come into contact with flames. If cooking with the grill cover closed, only use medium or low heat.

• Make sure the probe tip is inserted into the meat at least 1 inch.

• If the temperature displayed seems to read too high or the temperature seems to increase too quickly, check to make sure the probe tip is not poking through the food to the outside. Reposition the probe tip in the center of the thickest part of food. Avoid touching bone or heavy fat areas.


What are the safety cautions for using the WILLIAMS-SONOMA MAV219?

(1) Not Intended for Use by Persons ages 12 and Under.

(2) Always wear a heat resistant glove to touch the stainless steel probe sensor or wire during or just after cooking. Do not touch with bare hands.

(3) Keep the stainless steel probe sensor and wire away from children.

(4) Clean the stainless steel probe and dry thoroughly after each and every use.

(5) Do not use the receiver in the rain, it is not waterproof.

(6) Do not expose the plug of the stainless steel probe or the plug-in hole of the transmitter to water or any liquid. This will result in a bad connection and faulty readings.

(7) Do not expose the receiver or transmitter to direct heat or surface.

(8) Do not use stainless steel probe in microwave oven.

(9) The Remote Thermometer registers temperatures as low as 14°F (-10°C) and as high as 482°F (250°C). LLL will be displayed below 14°F and HHH will be displayed above 482°F.

(10) Do not use the stainless steel probe sensor above 410°F. Doing so will deteriorate the wire.


How do I clean my WILLIAMS-SONOMA MAV219 thermometer?

(1) Always wear a heat resistant glove to touch the stainless steel probe sensor or wire during or just after cooking. Do not touch with bare hands.

(2) Keep the stainless steel probe sensor and wire away from children.

(3) Wash the metal probe tip with hot soapy water and dry thoroughly. Do not immerse the probe in water while cleaning.

(4) Wipe the transmitter and receiver with a damp cloth. Do not immerse either in water.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD WILLIAMS-SONOMA MAV219 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.