Free English VICKS FILTERFREE V4600 (01) PDF Document. Free English VICKS FILTERFREE V4600 (01) PDF User Guide. Free English VICKS FILTERFREE V4600 (01) PDF User Manual. Free English VICKS FILTERFREE V4600 (01) PDF Owner Guide. Free English VICKS FILTERFREE V4600 (01) PDF Owner Manual. Free English VICKS FILTERFREE V4600 (01) PDF Reference Guide. Free English VICKS FILTERFREE V4600 (01) PDF Instruction Guide. Free English VICKS FILTERFREE V4600 (01) PDF Reference Manual. Free English VICKS FILTERFREE V4600 (01) PDF Instruction Manual. Free English VICKS FILTERFREE V4600 (01) PDF Operating Instructions.


CLICK HERE TO DOWNLOAD VICKS FILTERFREE V4600 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

How does the VICKS FILTERFREE V4600 humidifier work?

The VICKS FILTERFREE V4600 is designed to quietly provide visible cool moisture. Water is released from the water tank into the base where a small disk vibrates at a high frequency to break the water into tiny droplets. A small, ultra-quiet fan then propels these droplets into the air.


What optional accessories can be used with the VICKS FILTERFREE V4600?

The following optional accessories work with your VICKS FILTERFREE V4600 humidifier:

Vicks VapoPads®: Up to 2 scent pads can be used to provide soothing menthol (VSP-19) or lavender/rosemary (VBR-5) vapors.

Protec® Demineralization Cartridge (PDC51V1 or PDC51CV1): Helps remove minerals from the water and prevent white dust. This is best for areas with hard water if not using distilled water.

Protec® Cleaning Cartridge (PC-1, PC-1C or PC-2): Helps keep your humidifier cleaner for longer by continuously cleaning and protecting against bacteria & mold. It keeps cleaning for 30 days.


How do I set up my VICKS FILTERFREE V4600 for the first time?

Step 1. Remove the humidifier from the box and remove all packaging material. Set aside the instruction manual. Recycle packaging materials or save them for storage.

Step 2. Remove the twist tie from the power cord and extend the power cord to its full length. DO NOT OPERATE WITH THE POWER CORD COILED OR WITH THE TWIST TIE IN PLACE.

Step 3. Select a firm, level location at least 6 inches (15cm) from any walls. Place the humidifier on a water-resistant surface. The mist should be directed away from any walls, bedding, or furniture.


How do I fill or refill the VICKS FILTERFREE V4600?

Note: The tank should be carried using two hands. One hand should use the carrying handle on the tank top, and the other hand should support the base of the tank.

Step 1. Remove the tank by grasping the handle and pulling up. Remove the tank cap located on the bottom of the tank.

Step 2. Fill the tank with cool water. Do not fill with warm or hot water.

Step 3. Replace the tank cap by firmly turning it back in place. Place the tank back on the humidifier base.


What are the operating instructions for the VICKS FILTERFREE V4600?

1. Power: With the power switch in the OFF position, plug the filled humidifier into a polarized 120V outlet. Do not force the polarized plug into the outlet; it will only fit one way. Do not plug the humidifier in with wet hands to avoid electric shock.

2. Output: Set the control to your desired output setting. It is recommended to set the output to high until you reach a comfortable humidity level. The green nightlight on the control knob will illuminate, and after 10-15 seconds, your humidifier will produce a visible mist.

3. Humidity Level: Once you have reached a comfortable humidity level, turn the humidifier to a lower setting. A comfortable humidity level is between 40-60%. If you notice condensation on the walls or windows, your humidity level is too high and you should turn your humidifier off.

4. Caution: Do not operate your humidifier without the tank in place or if the unit is empty. When moving the humidifier, always turn it off and unplug it.


How do I use Vicks Scent Pads with my VICKS FILTERFREE V4600?

Note: You can use up to 2 scent pads in this device. For maximum vapors, use 2 pads.

Step 1. You can use Vicks Scent Pads (VSP-19 series, VBR-5 series, or VVP-6 series) with your humidifier to provide up to 8 hours of soothing vapors.

Step 2. Open the Scent Pad by tearing the notch on top of the pad bag. Do not touch the pad with your hands. If the pad is touched, do not rub your face as it may cause eye irritation.

Step 3. Open the scent pad door located on the side of the unit. Insert the scent pad(s) with the angled end facing towards the product. Close the door.

Step 4. Your scent pad will last 8 hours. After 8 hours, open the door, remove the old scent pad(s), and discard. If you choose to continue using scent pads, follow steps 2 and 3 again.

Recommended Usage:

• Not recommended for infants under 10 lbs (4.5 kg).

• For children between 10-22 lbs (4.5-10 kg), do not use more than 2 pads in a 24-hour period.


How do I perform weekly scale removal on my VICKS FILTERFREE V4600?

Note: All maintenance should be done in the kitchen or bathroom on a water-resistant surface. If using accessories like a demineralization or cleaning cartridge, remove them before cleaning as they cannot be cleaned.

Step 1. Always turn off the power switch and disconnect the power cord from the electrical outlet before cleaning.

Step 2. Remove the Water Tank and empty any water from the base.

Step 3. Remove the mist nozzle and water tank cap and set them aside.

Step 4. Fill the water tank from the bottom and the water tray area of the base with 1 cup of distilled white vinegar.

Step 5. Place the mist nozzle and tank cap in the water tray area of the base to soak.

Step 6. Let the parts soak for 15-20 minutes.

Step 7. Using a soft cloth, gently clean the transducer area in the base to remove mineral deposits.

Step 8. Rinse the water tray area of the base, water tank, tank cap, and mist nozzle until the smell of the vinegar solution is gone. CAUTION: DO NOT IMMERSE THE BASE IN WATER.

Step 9. To clean the scent pad area, gently wipe out the scent pad heater area with a soft damp cloth. DO NOT USE VINEGAR OR BLEACH SOLUTION TO CLEAN THIS AREA.


How do I disinfect my VICKS FILTERFREE V4600?

Disinfect your humidifier after completing the scale removal process.

Step 1. Add 1 Teaspoon of bleach to 1 gallon (3.8L) of water.

Step 2. Add ½ to ¾ gallon (1.9-2.8L) of the water/bleach solution to the water reservoir of the main housing and the water tank.

Step 3. Follow steps 5 through 8 from the scale removal section (soak for 15-20 minutes and then rinse all parts thoroughly).

NOTE: Be careful with clothing, rugs, and other non-bleach-resistant materials when disinfecting. Spilling bleach on these surfaces may cause damage. Using more than 1 teaspoon of bleach per gallon of water will result in damage to your humidifier.


How do I re-assemble my VICKS FILTERFREE V4600 after cleaning?

Step 1. Snap the mist nozzle back into the opening on top of the tank.

Step 2. Assemble the water cap back on the base of the tank.

Step 3. Place the tank back onto the base of the unit.


How should I store my VICKS FILTERFREE V4600 at the end of the season?

Follow the cleaning instructions when the humidifier will not be used for at least one week or more, or at the end of the season. At the end of the season, remove any accessories used with the humidifier and allow them to dry properly. Dry the humidifier completely before storing. DO NOT store with water inside the main housing water reservoir or water tank. Pack the unit in its original carton and store it in a cool, dry location.


What are the important safety instructions for using the VICKS FILTERFREE V4600?

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons, including the following:

1. The appliance should always be placed on a firm, flat, waterproof surface at least four feet (1.2 m) away from the bedside, six inches (15 cm) from the wall, and out of reach of patients, children, and pets.

2. The appliance should not be left unattended in a closed room since air could become saturated and leave condensation on walls and furniture. Leave the room door partly open. Do not aim the mist nozzle directly at children, walls, or furniture.

3. Before using the appliance, extend the cord and inspect for any signs of damage. Do not use the unit if the cord has been damaged.

4. The appliance has a polarized plug. Do not attempt to defeat this safety feature.

5. To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.

6. The appliance should always be unplugged and emptied when not in operation or while being cleaned. Shut off and unplug the humidifier before moving. Do not move or tilt the humidifier while it is in operation. Plug and unplug the unit with dry hands. Never pull by the cord.

7. Do not operate the appliance without water. Turn off and unplug the unit when the tank is empty.

8. Caution: To avoid the risk of fire, shock, or personal injury, do not use an extension cord or power strip.

9. The appliance requires regular cleaning. Refer to and follow the cleaning instructions.

10. Do not operate outdoors; this appliance is intended for indoor use.

11. Do not cover or insert objects into any openings on the unit.

12. Do not attempt to repair or adjust any electrical or mechanical functions on this appliance.

13. For Residential Use Only.

14. Do not place in direct sunlight, high-temperature areas, or near computers or sensitive electronic equipment.

15. Do not touch the nebulizer while the unit is plugged in as burns could result.

16. Do not touch skin with an exposed VapoPad® or place it on furniture, fabric, bedding, or plastic.

17. Do not add any medications (e.g., Kaz Inhalant or Vicks VapoSteam®) into the Nozzle, Base, Reservoir, or Water Tank.


Troubleshooting: What should I do if the power switch is set to “On” and the nightlight is off on my VICKS FILTERFREE V4600?

If the power switch is on but the nightlight is off, there may be an issue with the power supply.

Possible Cause:

• The unit is not plugged in.

• There is no power at the outlet.

Solution:

• Plug the unit in.

• Check circuits, fuses, and test the outlet.


Troubleshooting: Why is my VICKS FILTERFREE V4600 producing little or no mist?

If your humidifier is not producing an adequate amount of mist, check the following:

Possible Causes:

• There is no water in the tank.

• The unit is not on a level surface.

• There are mineral deposits on the nebulizer.

• The Water Tank or Base was washed with detergent.

Solutions:

• Fill the Water Tank.

• Place the unit on a level surface.

• Clean the nebulizer by following the Weekly Care & Cleaning instructions.

• Rinse the tank or base thoroughly with clean water.


Troubleshooting: What should I do if water overflows from the reservoir of my VICKS FILTERFREE V4600?

If water is overflowing from the reservoir, it could be due to the following reasons:

Possible Cause:

• The tank may be leaking.

• The tank cap is not tight.

Solution:

• Check the Tank for leaks and replace it if necessary.

• Tighten the Tank Cap.


Troubleshooting: Why is condensation forming around my VICKS FILTERFREE V4600 or on windows?

If you see condensation, the humidity level in the room is likely too high.

Possible Cause:

• The Mist Intensity is set too high for the room size or pre-existing humidity level.

Solution:

• Decrease the mist output to a lower setting or open a door to the room.