VENTS PA 02 E (01) PDF SUMMARY:
What is the purpose of the PA E air supply unit? The unit is designed to supply heated air in air supply systems of private residences, offices, hotels, cafes, conference halls, and other accommodation and public spaces.
Is the PA E air supply unit designed for autonomous operation? No, the PA E is a component unit and is not designed for autonomous operation.
What type of air should not be transported through the unit? The transported air must not contain any combustible or explosive mixtures, chemical fumes, coarse dust, soot, fat, or any environment prolific for the formation of harmful substances (toxic substances, dust, and pathogens) as well as sticky substances and fibrous materials.
Who is not intended to operate the unit? The unit is not intended for operation by children or any persons with reduced physical, mental, or sensory capacities as well as persons lacking the required training.
Who should handle the unit? The unit must be handled only by properly qualified personnel after the appropriate safety briefing.
Where should the unit be installed? The installation area of the unit must be chosen to prevent access by unattended children.
What is included in the delivery set of the PA E air supply unit? The delivery set includes:
- Unit – 1 piece
- Operation Manual – 1 piece
- Delivery Packing: wooden box – 1 piece
What does the designation key for the unit consist of? The designation key consists of:
- Unit Type: PA – air supply unit
- Capacity, m3/h: 01, 02, 03
- Heater Type: E – electric heater
- Number of power voltage phases
What are the operating ambient temperature ranges for the unit? The unit is designed for operation in an enclosed area at ambient temperatures:
- PA 01 E: from -25 ºC to + 55 ºC
- PA 02 E and PA 03 E: from -25 ºC to + 45 ºC
What is the relative humidity range for operating the unit? The unit is designed for operation at a relative humidity of up to 80%.
What are the hazardous parts access and water ingress protection standards for the unit?
- Unit motors – IP 44
- Unit assembly connected to air ducts – IP 22
What are the outside and connecting dimensions of the PA 01 E unit?
- B: 400 mm
- B1: 420 mm
- B2: 624 mm
- B3: 582 mm
- H: 200 mm
- H1: 220 mm
- H2: 374 mm
- L: 1145 mm
- L1: 1106 mm
What are the outside and connecting dimensions of the PA 02 E unit?
- B: 500 mm
- B1: 520 mm
- B2: 689 mm
- B3: 646 mm
- H: 300 mm
- H1: 320 mm
- H2: 447 mm
- L: 1250 mm
- L1: 1212 mm
What are the outside and connecting dimensions of the PA 03 E unit?
- B: 600 mm
- B1: 620 mm
- B2: 888 mm
- B3: 744 mm
- H: 350 mm
- H1: 370 mm
- H2: 500 mm
- L: 1252 mm
- L1: 1212 mm
What is the supply voltage for all models of the unit? The supply voltage is 3 ~ 400 V/50 Hz
What is the maximum fan power for the PA 01 E unit? The maximum fan power is 320 W
What is the maximum fan power for the PA 02 E unit? The maximum fan power is 620 W
What is the maximum fan power for the PA 03 E unit? The maximum fan power is 1330 W
What is the fan current for the PA 01 E unit? The fan current is 0.55 A
What is the fan current for the PA 02 E unit? The fan current is 1.05 A
What is the fan current for the PA 03 E unit? The fan current is 2.4 A
What is the electric heater power for the PA 01 E unit? The electric heater power is 12.0 kW
What is the electric heater power for the PA 02 E unit? The electric heater power is 18.0 kW
What is the electric heater power for the PA 03 E unit? The electric heater power is 21.0 kW
What is the electric heater current for the PA 01 E unit? The electric heater current is 17.4 A
What is the electric heater current for the PA 02 E unit? The electric heater current is 26.0 A
What is the electric heater current for the PA 03 E unit? The electric heater current is 30.0 A
What is the total unit power for the PA 01 E unit? The total unit power is 12.4 kW
What is the total unit power for the PA 02 E unit? The total unit power is 19.0 kW
What is the total unit power for the PA 03 E unit? The total unit power is 22.4 kW
What is the maximum unit current for the PA 01 E unit? The maximum unit current is 18.0 A
What is the maximum unit current for the PA 02 E unit? The maximum unit current is 27.1 A
What is the maximum unit current for the PA 03 E unit? The maximum unit current is 32.4 A
What is the maximum air flow for the PA 01 E unit? The maximum air flow is 1275 m3/h
What is the maximum air flow for the PA 02 E unit? The maximum air flow is 2500 m3/h
What is the maximum air flow for the PA 03 E unit? The maximum air flow is 3350 m3/h
What is the rotation speed for the PA 01 E unit? The rotation speed is 2700 min-1
What is the rotation speed for the PA 02 E unit? The rotation speed is 2690 min-1
What is the rotation speed for the PA 03 E unit? The rotation speed is 2730 min-1
What is the sound pressure level at 3m for the PA 01 E unit? The sound pressure level is 51 dB(A)
What is the sound pressure level at 3m for the PA 02 E unit? The sound pressure level is 54 dB(A)
What is the sound pressure level at 3m for the PA 03 E unit? The sound pressure level is 57 dB(A)
What is the maximum transported air temperature for the PA 01 E unit? The maximum transported air temperature is from -25 to +55 °C
What is the maximum transported air temperature for the PA 02 E and PA 03 E units? The maximum transported air temperature is from -25 to +45 °C
What is the casing material of the unit? The casing material is Aluzinc
What is the insulation material of the unit? The insulation is 50 mm, mineral wool
What type of filter panel is used in the unit? The filter panel type is G4
What is the connected duct size for the PA 01 E unit? The connected duct size is 400×200 mm
What is the connected duct size for the PA 02 E unit? The connected duct size is 500×300 mm
What is the connected duct size for the PA 03 E unit? The connected duct size is 600×350 mm
What is the weight of the PA 01 E unit? The weight is 56 kg
What is the weight of the PA 02 E unit? The weight is 61 kg
What is the weight of the PA 03 E unit? The weight is 91 kg
What should be considered while operating and mounting the unit? Consider the requirements of the present operation manual as well as general requirements of all applicable local and national building and electrical codes and standards.
What must be done before connecting the unit to the power mains? Before connecting the unit to power mains make sure that the unit is free of any visible damages or any other foreign objects inside the casing that can damage the impeller blades.
What must be done prior to any mounting, servicing, connection or repair operations with the unit? Disconnect the unit from the power supply prior to any mounting, servicing, connection or repair operations with the unit.
What are some things that you should not do with the unit?
- Do not operate the unit beyond the specified temperature range or in an aggressive and explosive medium.
- Do not connect clothes dryers or similar equipment to the ventilation system.
- Do not operate the unit in the air and dust mixture medium.
What is the unit designed for in terms of air supply? The unit is designed for the supply of purified and heated intake air.
What are the basic components of the unit? The basic configuration includes:
- Electric motor with a fan (Item 1)
- Built-in electric heater (Item 2)
- Class G4 filter (Item 3)
- Detachable cover (Item 4)
What should the unit installation ensure? The unit installation must ensure sufficient access for maintenance, servicing, or replacement operations.
What must match the air flow direction in the system during installation? The arrow on the cover must match the air flow direction in the system.
How can the unit be suspended? The unit can be suspended on a rod threaded into an expansion anchor or, alternatively, securely fixed in a horizontal position.
How is the unit integrated into a ventilation system? The unit is integrated into a ventilation system by connection to rectangular or round air ducts with the appropriate fittings (not included in the basic package).
What is recommended for best performance when installing the unit? For best performance, provide a straight section of air duct at least 1 m long on each side while installing the unit.
What should the unit be equipped with to prevent free access to the fans? The unit must be equipped with a grill or other device (maximum mesh size – 12.5 mm) to prevent free access to the fans.
What type of substructure must the unit be mounted on? The unit must be mounted on a rigid and stable substructure.
How should the unit be suspended? Suspend the unit with bolts.
What should be made sure of regarding the mating structure when installing the unit? Make sure that the mating structure can withstand the weight of the block.
What should be done if necessary to reinforce the installation area? If necessary, reinforce the installation area with beams etc., and then install the suspension bolts.
What can insufficient strength of the structure used for the installation result in? Insufficient strength of the structure used for the installation may resonate in response to the block vibrations resulting in noise.
What should always be arranged for when installing the unit? Always arrange for a maintenance zone and an access hole in the ceiling for inspection of the filters, heat exchanger, and fans.
How many access holes should be provided for each unit? Provide a separate access hole for each unit.
What should be ensured prior to installation? Prior to installation, make sure that the ambient conditions are suitable for the unit operation.
What can insufficient length of the mounting bolts cause? Insufficient length of the mounting bolts to be used for attaching the unit to the ceiling may cause abnormal noise due to resonance with the ceiling.
How can resonance be prevented when mounting the unit? To prevent resonance, use sufficiently long bolts.
What should be done if abnormal noise is generated at the coiled duct mating? If the abnormal noise is generated at the coiled duct mating, replace the coiled duct with a flexible line, or, alternatively, use flexible inserts to eliminate resonance.
What is the unit designed for connection to? The unit is designed for connection to 400 V / 50 Hz three-phase AC mains.
How should the connection to the power mains be made? The connection is made using durable, insulated and heat-resistant conductors (cables and wires) with the minimum section of 4 mm2.
What should the choice of wire section be based on? The choice of the required wire section in each case shall be based on the wire type, its maximum permissible heating temperature, its insulation, length and installation method.
What type of wires should be used? Use only copper core wires.
How must the unit be connected to the power mains? The unit must be connected to the power mains via an automatic cutout switch built into the stationary wiring with a magnetic breaker.
What should the trip current be for the automatic cutout switch? The trip current shall slightly exceed the current consumption.
Where should the fan electric motor connections be made? The fan electric motor connections shall be made on terminal block X1 mounted inside the terminal box on the unit side wall in accordance with the electrical wiring diagram and terminal designations.
Where can the terminal designation diagram be found? The terminal designation diagram is glued on the inside of the terminal box.
How are the cables routed into the terminal box? The cables are routed into the terminal box on the unit side wall through a sealed lead-in on the box wall to ensure protection class compliance.
What must the external lead-in be equipped with? The external lead-in (400V/50Hz) must be equipped with an automatic cutout switch with a magnetic breaker built into the stationary wiring to disconnect all the mains phases.
What must the position of the external switch ensure? The position of the QF external switch must ensure free access for quick power-off.
How is the electric heater power supplied? The electric heater power (contacts L1, L2 and L3) is supplied autonomously to terminal block X2 on the heater side wall according to the electrical wiring diagram.
What is terminated on the same block as the electric heater power? The same block terminates the normally closed contacts of thermal switches (TS1 and TS2 — from the automatic reset thermal switch; TS3 and TS4 — from the emergency thermal switch with manual reset) which commutate the electric heater power circuits depending on the customer’s needs.
What must be done prior to any electrical work? Disconnect the unit from the power mains prior to any electrical work.
Who should perform the power mains connection? The power mains connection shall only be performed by professional electricians qualified for unassisted operations with electrical installations up to 1000 V after careful reading of the present operation manual.
Where can the rated electrical parameters of the unit be found? The rated electrical parameters of the unit are given on the manufacturer’s label.
What is prohibited and will void the warranty? Any tampering with the internal connections is prohibited and will void the warranty.
What must be followed if the product is equipped with a complete automatic control system? If the product is equipped with a complete automatic control system, the internal electrical connections and the external connections must be made in accordance with «Automatic Control System of Air Supply Unit with Electric Air Heater» operation manual (included in the delivery package).
How often are maintenance operations of the unit required? Maintenance operations of the unit are required 3-4 times per year.
What does maintenance include? Maintenance includes regular cleaning and the following operations:
- Filter maintenance
- Fan inspection
- Ductwork system inspection
How often should the filters be maintained? The filters require cleaning once in 3-4 months.
How should the filters be cleaned? Vacuum cleaning is allowed.
How often should worn-out filters be replaced? Worn out filters should be replaced with the new filters once or twice per year.
Where can new filters be obtained? Contact your local manufacturer representative for new filters.
How do you replace the filter? To replace the filter:
- Remove the cover.
- Replace the filter.
- Reinstall the cover.
How often should the fan be inspected? The fan should be inspected once per year.
How should the fan be cleaned? Clean the fan with a soft brush or cloth.
What should not be used for cleaning the fan? No water and abrasive detergent, sharp objects or solvents are allowed for cleaning to prevent the impeller damage.
How often should the ductwork system be inspected? The ductwork system should be inspected once in 5 years.
What does duct maintenance mean? Duct maintenance means regular cleaning or replacements.
What are the possible reasons and fault handling when the fan does not get started? Possible reason: No power supply. Fault handling: Make sure the power supply line is connected correctly, otherwise troubleshoot the connection error.
What are the possible reasons and fault handling when there is cold supply air? Possible reason: Filter is clogged. Fault handling: Clean or replace the filter.
What are the possible reasons and fault handling when there is low air flow? Possible reasons:
- Filter or fan is clogged.
- Ventilation system is clogged or damaged. Fault handling:
- Clean or replace the filter; clean the fan.
- Check the grille and clean it if required. Make sure that the air ducts are not soiled and not damaged.
What are the possible reasons and fault handling when there is noise or vibration? Possible reasons:
- Fan impeller is clogged.
- The fan screws are loose. Fault handling:
- Clean the fan impeller.
- Check the screw tightening.
How should the unit be stored? Store the unit in the manufacturer’s original packing box in a closed ventilated premise with temperature range from +10°C to +40°C and relative humidity less than 80% (at +20°C).
What is not allowed in the storage environment? Vapors or particles which can cause corrosion or damage the insulation or connection tightness are not allowed in the storage environment.
What should be used for handling and transportation of the unit? Use hoist machinery for handling and transportation to prevent possible mechanical damages of the unit.
What requirements should be fulfilled during cargo-handling operations? Fulfill the requirements for transportation of the specified cargo type during cargo-handling operations.
What type of vehicles can be used for the unit transportation? Use any vehicle types for the unit transportation provided that it is protected against mechanical or weather damage.
What should be avoided during handling operations? Avoid any mechanical shocks and strokes during handling operations.
When are warranty claims accepted? Warranty claims are accepted with the user’s manual and filled connection certificate only.
What is the manufacturer not responsible for? The manufacturer is not responsible for any mechanical or physical damages resulting from the manual requirements violation, the unit misuse or gross mechanical effect.
How long is the manufacturer’s warranty period? The manufacturer guarantees normal performance of the unit during two years from the date of retail sale provided compliance with transport, storage, mounting and operation regulations.
How is the warranty period calculated if there is no confirmation of the sales date? In case of no confirmation of the sales date the warranty period is calculated from the manufacturing date.
What must be submitted in case of failures in the unit operation during the warranty period? In case of failures in the unit operation during the warranty period the manufacturer will accept reclamations and complaints from the owner of the device only after receiving technically sound act with detailed description of the failure.
When is unit damage not a warranty case? Unit damage as a result of unauthorized tampering with the circuit diagram is not a warranty case.
Who should be contacted for warranty and post-warranty services of the unit? For warranty and post-warranty services of the unit please contact the product manufacturer.
What should be submitted in case of a warranty claim? In case of warranty claim please submit the user’s manual with the seller’s stamp, filled connection certificate, and warranty card.
Where are warranty repair services and post-warranty services fulfilled? Warranty repair services and post-warranty services are fulfilled at the manufacturing facility.