VALUE VP2120 (01) Image

FREE ENGLISH VALUE VP2120 (01) PDF DOCUMENT.
FREE ENGLISH VALUE VP2120 (01) PDF USER GUIDE.
FREE ENGLISH VALUE VP2120 (01) PDF USER MANUAL.
FREE ENGLISH VALUE VP2120 (01) PDF OWNER GUIDE.
FREE ENGLISH VALUE VP2120 (01) PDF OWNER MANUAL.
FREE ENGLISH VALUE VP2120 (01) PDF REFERENCE GUIDE.
FREE ENGLISH VALUE VP2120 (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH VALUE VP2120 (01) PDF REFERENCE MANUAL.
FREE ENGLISH VALUE VP2120 (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH VALUE VP2120 (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD VALUE VP2120 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What should I do when I first receive my VALUE VP2120 vacuum pump?

Upon receiving your product, please perform the following checks:

1. Ensure the product received is the same as the one you ordered.

2. Verify that all accessories, including the first-time use vacuum oil, are present as per the contract.

3. Check for any damage that may have occurred during transportation.

4. Please read the operating manual carefully before operating the pump.

5. Important: Add vacuum oil to the VALUE VP2120 before starting it up for the first time.


What are the key safety warnings and precautions for the VALUE VP2120?

To ensure safe and efficient operation, please observe the following:

Electrical Safety:

• Before connection, check that the power supply is the same as the required power supply specified for the pump.

• Electrical connection work must only be carried out by a skilled electrician.

• The product must be grounded, and the motor circuit must be equipped with a suitable rated motor protection switch before starting.

• Disconnect the pump from the power supply during electrical connection, repair, and maintenance to prevent electrical shock.

Operational Safety:

• Do not touch the pump when it is hot. When opening the pump, wait until it has cooled down.

• Do not place obstacles that could influence ventilation around the motor, to avoid scalds or fire.

• The exhaust line must be unblocked before operating. Ensure gas flow from the exhaust port is not blocked or restricted.

• The pump must be operated at ambient temperatures between 5-40°C.

• The VALUE VP2120 is not suitable for pumping toxic, corrosive, flammable, or explosive gas.

• This pump is strictly prohibited from operating in explosion hazard and flammable areas.

Handling:

• Do not invert the pump or subject it to any impact, as this may cause damage.


What are the environmental requirements for operating and storing the VALUE VP2120?

To achieve stable and reliable operation, the following requirements should be satisfied during storage and operation of the VALUE VP2120:

Working ambient temperature/humidity: 5-40°C, below 85% RH.

Storage and Operating altitude: < 1000m.

Storage and operating environment:

1) No corrosive, flammable, and explosive gases.

2) The pump must be stored in a room with good ventilation.

3) Avoid direct sunlight.

4) Keep far away from heat sources.

5) No dust.

6) No frost.


How does the VALUE VP2120 vacuum pump work?

The VALUE VP2120 is a double-stage, direct-coupled, rotary-vane vacuum pump. The rotor is mounted eccentrically in the pump cylinder and has two vanes. As the motor drives the rotor clockwise, the vanes divide the pump chamber into compartments that change in size.

1. Suction: One chamber expands, sucking air in from the system.

2. Transmission: The trapped air is transferred to the next stage.

3. Compression & Exhaust: Another chamber compresses the air and exhausts it. This work cycle repeats continuously to achieve a vacuum.

As a double-stage pump, the gas exhausted from the first stage is drawn into the second (low vacuum) stage, which then compresses and exhausts it to the atmosphere. This allows the pump to achieve a higher ultimate vacuum.


What are the technical specifications for the VALUE VP2120?

Specification VALUE VP2120
Displacement speed (CFM) 50Hz 12
Displacement speed (CFM) 60Hz 14
Ultimate partial pressure without gas ballast (Pa) 4 x 10⁻²
Ultimate total pressure without gas ballast (Pa) 4 x 10⁻¹
Ultimate total pressure with gas ballast (Pa) 8 x 10⁻¹
Power Supply Single/3-ph
Power rating (KW) 0.75/0.55
Inlet fitting 6-7/16-20
Oil Capacity (L) 0.9~1.5
Motor speed (rpm) 50Hz 1440
Motor speed (rpm) 60Hz 1720
Ambient temperature 5-40°C
Noise level (dB) <58
Weight (kg) 36

How should I install the VALUE VP2120?

Transportation:

• Handle with care, as any negligence can cause damage.

• The pump must only be moved when it is stopped and the power supply is switched off.

• When lifting, you must use the hook provided on the pump.

Installation Site:

• Choose a site that is suitable for installation, maintenance, and disassembly.

• Ensure there is good ventilation.

• The site should be convenient for electrical connection.

• The pump is strictly prohibited to operate in explosion hazard and flammable areas.

Installation Procedure:

• The pump should be set up on a flat and firm surface. Oblique installation may result in vibration, high noise, or damage.

• When connecting the VALUE VP2120 to a vacuum system, place the pump horizontally on its casters.


How do I add oil to the VALUE VP2120?

1. Open the oil fill plug.

2. Add the recommended high speed vacuum oil according to the technical data (0.9~1.5 L for the VP2120).

3. For the first time, add oil to the recommended oil level, which is visible in the sight glass between the MIN and MAX marks. The ideal level is around 80% of the sight glass height.

4. The pump must be switched off before adding any oil.

Note: Using oil other than the recommended VALUE VPO series oil may cause unstable performance and affect the pump’s lifespan. Excessive or insufficient oil will decrease performance or cause malfunction.


How do I connect the electrical supply to the VALUE VP2120?

Single-Phase Motor:

For the single-phase VALUE VP2120, the power supply cable, switch, and overload protector are all connected. The direction of rotation is fixed. The pump can be directly connected to a single-phase power supply using the provided cable and plug. The motor is protected by a thermal overload protector.

Three-Phase Motor:

1. Open the junction box cover.

2. Connect the pump using an appropriately rated cable and a suitably rated motor protection switch. The current rating must match the motor nameplate.

3. Check if the motor rotation direction matches the arrowhead on the motor. If it is incorrect, immediately cut the power and interchange any two of the three phase connections (e.g., W1, U1, V1) to correct the rotation.

4. Motor Direction Test: Open the inlet and exhaust ports. Place a slip of paper about 50mm above the exhaust port. Briefly switch the motor on and off. If the paper slip is pushed upward, away from the exhaust port, the direction is correct.


What are the requirements for connecting the VALUE VP2120 to a vacuum system?

• The connecting lines between the pump and the vacuum system should be as short as possible, with minimal corners.

• The diameter (DN) of the connecting line should be the same as the pump’s intake port.

• Check the inlet port filter regularly and keep it clean.

• The exhaust line should preferably be installed with a downward slope to prevent condensate from flowing back into the pump and contaminating the oil. If the line has an upward slope, a condensate trap must be installed.

• Periodically drain condensed oil from the exhaust pipe to prevent blockage.

• A vacuum-tight connection is essential. Perform a leak check on the connection between the pipe and flange to ensure the pump can attain its ultimate vacuum.

• Never operate the pump with a blocked or constricted exhaust line.


How do I operate the VALUE VP2120?

Before Operating:

• Ensure the exhaust line is unblocked.

• Check that the oil capacity is suitable.

• Verify the running direction of the motor is correct.

• Ensure the motor is well grounded.

• Check that the power supply matches the pump’s specifications.

Operating with Non-condensable Gases:

When pumping permanent (non-condensable) gases, the gas ballast valve knob should be in the switched-off position (Arrow C). Opening the gas ballast may cause the ultimate pressure to rise (lower vacuum).

Operating with Condensable Gases:

If the system contains a small amount of condensable gas, open the gas ballast valve (Arrow I or II). This allows the pump to handle the condensable gas effectively. Once the system pressure has been reduced to a certain value, close the gas ballast valve for normal operation.

After Operation:

If the pump was operated at a low temperature, condensable gas may dissolve in the oil. To prevent this, do not switch off the pump immediately. Instead, keep the pump running for about 30 minutes with the gas ballast valve open and the intake line sealed. This will help remove dissolved gases from the oil.


How do I switch off the VALUE VP2120 and prepare it for long-term storage?

Normal Switching Off:

Under normal circumstances, the pump can be switched off directly. The inner anti-suckback valve will automatically switch off the air intakes, keeping the vacuum system clean.

Long-Term Storage:

If the VALUE VP2120 will be stopped for a long time, cover the inlet and exhaust ports to prevent dust from contaminating the pump.


How do I maintain the oil in my VALUE VP2120?

Checking Oil Level:

During operation, the oil level must always be visible between the Max and Min marks in the sight glass. Add oil if the level is below Min, and discharge oil if it is above Max. The recommended liquid height is best.

Checking Oil Quality:

Normally, the oil should be clear and transparent. If the oil darkens or becomes cloudy, it should be changed.

When to Change Oil:

• Change the oil if it contains a mass of liquid, organic solvents, or corrosive gases.

• Change the oil if the pump’s ultimate pressure declines over time.

• For the first usage of a new pump, the oil should be changed after the first 100 operating hours.

• It is recommended to change the oil every 2000 operating hours for normal, clean operation.

Oil Change Procedure:

1. Always perform an oil change when the pump is switched off and has cooled down to below 50°C. Wear suitable protective clothing.

2. Remove the oil drain plug and let the used oil drain into a suitable receptacle.

3. When the oil flow stops, screw the drain plug back in. Briefly switch on the pump for a maximum of 10 seconds, then switch it off. This will expel residual oil.

4. Remove the oil drain plug again and drain the remaining oil.

5. Screw the oil drain plug back in. Check the O-ring and replace it if necessary.

6. Remove the oil filling plug and fill with fresh oil to the correct level.


What is the routine checking schedule for the VALUE VP2120?

Inspection Testing Period Remarks
Oil level Eyeballing oil level Every Three Days Add oil if the oil level is low.
Oil color Eyeballing the oil color in the oil sight level Every Three Days Normally the oil is clear and transparent. If the oil darkens, it should be changed.
Pump noise Whether the noise is normal Every three days Refer to troubleshooting if the noise level is abnormal.
Pump vibration Whether there is any abnormal vibration Every Three Days Check whether any pump feet, feet screws loosen.
Pump temperature Temperature measuring meter Every one week Check the fan of the pump and motor for deposits and clean as required.
Seal & O ring Eyeballing Every one month Change it as required.
Dirt trap Check whether any foreign matter enters Every one month Clean the dirt trap and blow it out with compressed air.

How do I troubleshoot common problems with the VALUE VP2120?

Fault Possible Reason Solution
Pump can not be started 1. Out of electrical 1. Check the connection of power supply, switch
2. Operation voltage is abnormal 2. Voltage wave within ±10%
3. Motor is malfunctioning 3. Replace the motor
4. Overload protector start up 4. Press the overload protector
5. Oil temperature is below 10°C 5. Heat the pump and pump oil
6. Pump is jammed 6. Repair the pump
7. Out of operation for long, liquid and organic solvents result rust of the pump body 7. Repair the pump
8. Pump inner accessories are damaged 8. Repair the pump
Pump can not reach to the maximum pressure 1. Pump is too small 1. Replace the pump
2. Vacuum system leak 2. Check the leakage
3. Measuring technique or gauge is unsuitable 3. Use correct measuring technique and gauge. Measure the pressure directly at pump’s intake port
4. Vacuum gauge not correct 4. Chose suitable vacuum gauge
5. Oil level is too low 5. Add oil
6. Oil is unsuitable or deteriorated 6. Change oil
7. Lubricate seal oil channel inside pump blocked 7. Clean oil channel
8. Intake line is dirty 8. Clean the vacuum lines
9. Exhaust valve is malfunctioning 9. Repair the valve
Pumping speed is too low 1. Intake port channel is clogged 1. Clean the intake port channel
2. Connecting lines are too narrow or too long 2. Use adequately wide and short connecting lines
3. Exhaust port channel is clogged/unsuitable 3. Keep the exhaust port channel free
4. Exhaust filter is clogged 4. Clean or change the exhaust filter
Abnormal voice 1. Abnormal input power supply 1. Check the connection of power supply, switch
2. Motor is malfunction 2. Voltage wave within ±10%
3. Foreign body into the pump 3. Clean the pump body
4. Oil level is too low 4. Add oil
5. Coupling element is worn 5. Install new coupling element
6. Pump inner accessories are damaged 6. Repair or change the accessories
Higher temperature than normal 1. Continuous operation under high pressure in the intake port 1. Shorten exhaust time as far as possible
2. Oil level is too low 2. Add oil
3. Process gas is too hot 3. Set pump up correctly
4. Cooling air supply is obstructed 4. Set pump up correctly
5. Pump fan is malfunction 5. Change the pump fan
6. Oil cycle is obstructed 6. Clean and repair the oil lines and channels
7. Ambient temperature is too high 7. Reduce the ambient temperature
Oil in the intake line or in vacuum vessel 1. Oil comes from the vacuum system 1. Check the vacuum system
2. Anti-suckback valve spring is obstructed 2. Change the anti-suckback valve spring
3. Anti-suckback valve board is obstructed 3. Change the anti-suckback valve board
4. Oil level is too high 4. Drain the excess oil
After switching the pump off, pressure in system rises too fast 1. System has a leak 1. Check the vacuum system
2. Anti-suckback valve is malfunctioning 2. Repair the anti-suckback valve
Too much oil in the exhaust port 1. Too much oil in the pump 1. Drain some oil
2. Continuous operation under high pressure in the intake port 2. Shorten exhaust time as far as possible
Oil seal leak 1. Oil seal broken, oil leak 1. Replace new oil seal
2. Seal ring was deformed, oil leak 2. Replace new seal ring

What standard equipment and accessories are supplied with the VALUE VP2120?

Standard Equipment:

Upon delivery, the small-flange connection ports of the pump are blanked off. The following are supplied as standard equipment to connect the intake and discharge lines:

• Two flanges, two centering rings, and two clamping rings (KF25/KF40).

• One centering ring includes a dirt trap sieve for the intake port.

Single-Phase AC Motor Pump includes: Motor, switch, mains cable, and plug.

Three-Phase AC Motor Pump includes: Motor and crane eye. (A switch, mains cable and plug are not part of the standard equipment).

Optional Accessories:

• Other in/exhaust interface

• Dust filter

• Oil mist filter


What is the spare parts list for the VALUE VP2120?

NO. Item Item Code Position Qty
1 Washer Card board 320220101 Motor 1
2 Spider Rubber 320050101 (3-Phase) Coupling 1
2 Spider Rubber 320050102 (1-Phase) Coupling 1
3 Seal FKM 300281601 Oil pump cover 1
4 O-ring FKM 300310072 Front stator 1
5 O-ring FKM 300310137 Front rotor 1
6 Spring SUS 320110205 Trestle 1
7 O-ring FKM 300310074 Anti-suckback cover 1
8 Seal FKM 300280902 Anti-suckback cover 1
9 Valve FKM 320510101 Anti-suckback piston 1
10 O-ring FKM 300310073 Intake port 1
11 Control Valve ASSY / 320340102 Intake port 1
12 Vacuum Gauge / KF25:300310070 / 2
13 Spring SUS 320110302 Gas ballast 1
14 Washer FKM 320230101 Gas ballast 1
15 O-ring FKM 300310079 Trestle 1
16 Gasket Paper 320210101 Front chanter 1
17 Seal FKM 300280602 Front chanter 1
18 Spring SUS 320110104 Front/rear rotor 5
19 Vane Resin board VP2120: 320100101 Front rotor 2
20 Valve SUS 320240101 Rear chanter 1
21 Spring SUS 310080301 Rear chanter 1
22 Valve FKM 311150103 Rear chanter 1
23 Vane Resin board 320100201 Rear rotor 2
24 washer Paper 320200101 Outlet port 1
25 O-ring FKM 300310081 Oil-drain screw 2
26 O-ring FKM 320160101 Oil sight 1
27 Oil sight Glass 320170101 Oil sight 1
28 washer FKM 320190101 Oil sight 1
29 O-ring FKM KF25:300310070 Outlet port 1