What are the key features of the TRIPLETT 9200-A?
The TRIPLETT 9200-A features include:
• Economical, Compact AC Current Clamp-On
• Easily Fits in Shirt Pocket!
• Measures from 0 to 300 Amps AC in Two Ranges
• Simple, Two Button Operation
• Large, 3 3/4 Digit, 4000 Count Display
• Autoranging
• Data Hold
• Overrange Indication
• Auto Power Off
• Low Battery Indication
• Powered by one 3V Battery
• Carrying Case, Wrist Strap and Battery included
• 1 Year Limited Warranty
What are the specifications for the TRIPLETT 9200-A?
Display: 3 3/4 Digit, 4000 Count LCD, 12mm high
Operating Principle: Dual Slope Integration
Range Selection: Autoranging
Overload Indication: “OL” is displayed when input exceeds 405 A
Low Battery Warning: “BAT” symbol is displayed
Sampling Rate: 2.5 times per second
Data Hold: Holds reading when DH Button is pressed
Overload Protection: AC Current, 400A AC for 60 Seconds Max
Operating Temperature & Humidity: 32°F to 104°F, less than 80% non-condensing
Storage Temperature & Humidity: 14°F to 122°F, less than 70% non-condensing atmosphere
Safety / Agency Approvals: CE Mark, IEC 1010-1 Overvoltage CAT III 300VAC, Class II and EMC Test Passed
Auto Power Off: Power turns off after 12 min. of non-use. Note: Power consumption is reduced in Auto Power Off. For maximum battery life, turn the power off manually.
Battery: 1 – 3 Volt CR2032 Button Type (Included). Note: The installed battery may be depleted if product was turned on in the package. If so, replace battery with a fresh one.
Battery Life: 100 Hours Continuous Operation
Conductor Size: 27mm Max (1.14“)
Dimensions: 5.8″ (L) x 1.8″ (W) x 0.8″ (H)
Weight: 3.4 oz.
| Range | Resolution | Accuracy | Max. Input Current |
|---|---|---|---|
| 40.00A | 10mA | ±(1.8% rdg + 5 dgt) | 300A (Max 300V Line) |
| 300.0A | 100mA | ||
| Overload Protection: 400A AC for 60 Seconds Max | |||
| Frequency Response: 50Hz~60Hz, 0~0.4A add 5 dgt, 40Hz~500Hz, add 1.5% to above accuracy | |||
What do the symbols on the TRIPLETT 9200-A LCD display mean?
The symbols on the LCD display mean the following:
~ : Alternating Current (AC)
BAT: Low Battery Warning
AUTO: Autoranging
DH: Data Hold
A : Amps
APO: Auto Power Off
How do I operate the On/Off and Data Hold buttons on the TRIPLETT 9200-A?
On/Off Button: Momentarily press the ON/OFF Power Button to turn the unit on or off.
Data Hold (DH) Button: To save a reading in the display, momentarily press the DH (Data Hold) Button. The DH symbol will appear in the LCD display. To clear the saved reading, momentarily press the DH button again.
How should I use the Clamp Head on the TRIPLETT 9200-A?
When measuring AC Current, open the Clamp Head by pressing the Lever and clamp around a single conductor to be tested.
NOTE: You cannot measure the current to an appliance by clamping around its power cord. You must clamp around only the HOT or NEUTRAL conductor, not the entire cord.
What is the purpose of the Safety Guard on the TRIPLETT 9200-A?
For safety, your fingertips must NOT go past the Safety Guard.
What safety precautions should be followed when using the TRIPLETT 9200-A?
Read all WARNINGS and CAUTIONS in the manual before use. Failure to do so may result in product damage or injury.
WARNING: AC Power Lines are very dangerous and can be lethal. The TRIPLETT 9200-A is not designed for use in High Energy Circuitry, which is capable of supplying over 4000 watts to a load before a safety device interrupts the circuit.
General Warnings and Cautions:
• Do not let children use this instrument or those who are unable to recognize the dangers of electrical measurements.
• Do not make measurements while barefooted. This greatly increases the possibility of electrical shock.
• Do not attempt to clean the case with any harsh solvents. If necessary, use mild detergent and water.
• Avoid severe mechanical shock or vibration, extreme temperature or very strong magnetic field.
• Remove the battery when not in use for an extended period of time. A low battery might leak electrolyte and corrode the internal components.
What should I check about the condition of the TRIPLETT 9200-A meter before use?
Before every measurement, make sure that the meter is not damaged in any way (cracks, missing parts, etc.). Make sure that the body is free of dust, grease, and moisture.
Is the TRIPLETT 9200-A intended for use on High Energy Circuits?
No, this product is not intended for use on High Energy Circuits such as Distribution Transformers, Bus Bars, Large Motors, etc., which are very dangerous.
What are the maximum voltage and current limits for the TRIPLETT 9200-A?
The maximum current is 300A AC. The maximum voltage is 300V AC. Do not attempt to measure current that might exceed the specified value or current on lines whose voltage exceeds 300 VAC.
How do I prepare the TRIPLETT 9200-A for use?
1. Instruction Manual: Prior to use, read the Instruction Manual carefully and acquaint yourself with the specifications and functions of the instrument. Especially read and observe carefully the Safety Precautions in Section 4.
2. Battery: One 3V CR2032 battery is installed in this instrument. When the battery is low and “BAT” is displayed on the LCD, open the Battery Cover and replace the battery with a fresh one.
What does the “OL” display on the TRIPLETT 9200-A indicate?
If the Input Value exceeds approximately 405 Amps AC, “OL” is displayed on the LCD. This is an overrange indication.
WARNING!!! DO NOT attempt to make any measurements that might exceed 300A AC (max 300V Line).
How does the Auto Power Off feature on the TRIPLETT 9200-A work?
Approximately 12 minutes after the operation of either button on the product, the unit will go into a ‘sleep’ mode to reduce its power consumption. In the sleep mode, the LCD will turn off, but the unit is still operating at low power. To turn the unit off completely (which maximizes the battery life), press the ON/OFF button before the unit goes to sleep, or if the unit is sleeping, press the ON/OFF button to turn the unit on, then press it again to turn the unit off.
What do the international symbols on the TRIPLETT 9200-A instrument mean?
The following International Symbols shown on the instrument and in this instruction manual aid in the safe operation of the instrument:
A in a triangle: Caution (Refer to Instruction Manual)
~ : Alternating Current (AC)
Earth Ground symbol : Earth Ground
Square within a square : Double Insulation
How do I measure AC Current with the TRIPLETT 9200-A?
WARNING!!! Maximum Voltage of AC Current Line is 300V AC. DO NOT attempt to make any current measurements that might exceed 300A AC, the Maximum Input Current.
1. Momentarily press the ON/OFF button to turn the power on.
WARNING!!! For safe measurements, fingertips must be placed behind the Safety Guard of this instrument. DO NOT touch any part of the Power Line or the Electrical Circuit.
2. Open Clamp Head by pressing the Lever and clamp around a single conductor.
NOTE: You cannot measure the current to an appliance by clamping around its power cord. You must clamp around only the HOT or NEUTRAL conductor, not the entire cord.
3. Read the current on the LCD.
4. To capture the reading, activate the Data Hold by momentarily pressing the DH button.
5. When measurements are finished, remove Clamp Head from the conductor.
How do I replace the battery in the TRIPLETT 9200-A?
WARNING!!! Remove Clamp Head from the circuit being measured before attempting to replace the battery.
1. If the battery is low and “BAT” is displayed on the LCD, replace the battery.
2. Turn the Model 9200-A off.
3. Remove the screw on the Battery Cover on the back side of the instrument.
4. Replace the low battery with a fresh one – 3V CR2032 type.
NOTE: A small screwdriver or pair of tweezers may be helpful in removing the depleted battery. Insert tweezers (or similar tool) into the hole and push the battery up.
5. Replace the Battery Cover and screw.
How often should the TRIPLETT 9200-A be tested and calibrated?
Periodic tests and calibration are necessary to ensure safe and accurate measurements. It is recommended that the instrument be checked and calibrated once each year and/or after it is repaired.