TOSHIBA RAC-PD1013CWRU (01) Image

FREE ENGLISH TOSHIBA RAC-PD1013CWRU (01) PDF DOCUMENT.
FREE ENGLISH TOSHIBA RAC-PD1013CWRU (01) PDF USER GUIDE.
FREE ENGLISH TOSHIBA RAC-PD1013CWRU (01) PDF USER MANUAL.
FREE ENGLISH TOSHIBA RAC-PD1013CWRU (01) PDF OWNER GUIDE.
FREE ENGLISH TOSHIBA RAC-PD1013CWRU (01) PDF OWNER MANUAL.
FREE ENGLISH TOSHIBA RAC-PD1013CWRU (01) PDF REFERENCE GUIDE.
FREE ENGLISH TOSHIBA RAC-PD1013CWRU (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH TOSHIBA RAC-PD1013CWRU (01) PDF REFERENCE MANUAL.
FREE ENGLISH TOSHIBA RAC-PD1013CWRU (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH TOSHIBA RAC-PD1013CWRU (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD TOSHIBA RAC-PD1013CWRU (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What general safety precautions should be taken when using the TOSHIBA RAC-PD1013CWRU portable air conditioner?

This TOSHIBA RAC-PD1013CWRU appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the TOSHIBA RAC-PD1013CWRU air conditioner.

The TOSHIBA RAC-PD1013CWRU appliance shall be installed in accordance with national wiring regulations.

Do not operate your TOSHIBA RAC-PD1013CWRU air conditioner in a humid room such as a bathroom or laundry room.


What warnings should I be aware of regarding the installation and electrical connection of the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Be sure the TOSHIBA RAC-PD1013CWRU air conditioner has been securely and correctly installed according to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit.

Plug in power cord plug properly. Otherwise, it may cause electric shock or fire due to excess heat generation.

Do not modify power cord length or share the outlet with other appliances as it may cause electric shock or fire due to overheating.

Always ensure effective grounding. Incorrect grounding may cause electric shock.

Be sure the TOSHIBA RAC-PD1013CWRU air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards. Your TOSHIBA RAC-PD1013CWRU air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation.

Be sure the electrical service is adequate for the TOSHIBA RAC-PD1013CWRU model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille.

Do not damage or use an alternate power cord. It may cause fire and electric shock. If the power cord is damaged, it must be replaced by the manufacturer or a similarly qualified person in order to avoid a hazard.

Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prongs from the power cord.


What operational safety warnings should I follow for the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Unplug the unit if you notice unusual sounds or smells or smoke coming from it. A damaged product may cause fire and electric shock.

Ventilate room before operating the TOSHIBA RAC-PD1013CWRU air conditioner if there is a gas leakage from another appliance.

Do not operate or stop the unit by inserting or pulling out the power cord plug.

Do not operate with wet hands or in very humid environments. It may cause electric shock.

Do not allow water to come into contact with any electric parts. It may cause failure or electric shock.

Do not use the socket if it is loose or damaged. It may cause fire and electric shock.

Do not use or keep the power cord close to heating appliances. It may cause fire and electric shock.

Do not use any devices or materials for installation that are not recommended in this manual.

Do not disassemble or modify unit. It may cause failure and electric shock.

Do not direct airflow straight into persons to avoid possible health hazard.

Do not open the unit during operation. It may cause electric shock.

Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc. It may cause an explosion or fire.

Do not let children hang on the TOSHIBA RAC-PD1013CWRU air conditioner or bracket. A serious injury may occur.

Hold the plug by the head of the power plug when taking it out. Otherwise, it may cause electric shock and damage.

Ensure that the installation is properly secured to prevent the TOSHIBA RAC-PD1013CWRU product from potentially falling.

Do not place heavy objects on the power cord and ensure that the cord is not compressed. Otherwise, there is danger of fire or electric shock.

If water is spilled on the unit, turn off the unit and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician.

Do not use near gas stove or other gas burning appliances, as air flow may affect gas combustion.

Do not use the TOSHIBA RAC-PD1013CWRU for any purpose other than room comfort. Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. It may cause deterioration.

Turn off the main power switch if the unit is not to be used for an extended time.

Always insert the filters securely. Clean filter once every two weeks. Operation without filters may cause failure.

Do not drink water drained from the TOSHIBA RAC-PD1013CWRU air conditioner.


What cautions should I observe when handling and cleaning the TOSHIBA RAC-PD1013CWRU portable air conditioner?

When the air filter is to be removed, do not touch the metal parts of the unit. It may cause injury.

When the TOSHIBA RAC-PD1013CWRU unit needs cleaning, switch off, and turn off the circuit breaker. Do not clean unit when power is on as it may cause fire, electric shock or injury.

Do not place obstacles around air inlets or inside of air outlet. It may cause failure or accident.

Clean with a soft cloth only. Do not use strong detergents that contain wax or thinners as it may damage the TOSHIBA RAC-PD1013CWRU product.

Use caution when unpacking and installing. Sharp edges could cause injury.

Do not clean the TOSHIBA RAC-PD1013CWRU air conditioner with water. Water may enter the unit and degrade the insulation which could lead to electric shock.

Do not put a pet or house plant where it will be exposed to direct air flow. This could injure the pet or harm the plant.


What specific warnings apply to the TOSHIBA RAC-PD1013CWRU portable air conditioner if it uses R32 refrigerant?

Do not try to accelerate the defrosting process or methods of cleaning that are not recommended by the manufacturer.

The TOSHIBA RAC-PD1013CWRU appliance shall be stored in a room without a continuously operating ignition source (for example, open flames or an operating gas appliance) or an ignition source (for example, an operating electric heater) close to the appliance. The appliance shall also be stored in a room without ignition sources.

Do not pierce or burn the TOSHIBA RAC-PD1013CWRU unit.

Be aware that the refrigerants may not contain an odor.

Keep ventilation openings clear of obstruction on the TOSHIBA RAC-PD1013CWRU unit.

Flammable refrigerant R32 is used within the TOSHIBA RAC-PD1013CWRU air conditioner. Please follow the instructions carefully to handle, install, clean, and service the air conditioner to avoid damage or hazard. Do not dispose of the TOSHIBA RAC-PD1013CWRU air conditioner in regular trash. Contact qualified agency for proper disposal.

No open fire or devices that generate spark/arcing shall be around the TOSHIBA RAC-PD1013CWRU air conditioner to avoid causing ignition of the flammable refrigerant used. Please follow the instructions carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.


How do I test the power supply cord of the TOSHIBA RAC-PD1013CWRU portable air conditioner?

The power supply cord contains a current measuring device that detects damage to the power cord. Test your power supply cord as follows:

1. Plug in the TOSHIBA RAC-PD1013CWRU air conditioner.

2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out.

3. Press the RESET Button. You will notice a click as the button engages.

4. The power supply cord is now supplying electricity to the unit. (On some products this is also indicated by a light on the plug head.)


What should I know about the grounding prong on the TOSHIBA RAC-PD1013CWRU portable air conditioner’s power cord?

Do not, under any circumstances, cut, remove or bypass the grounding prong.

The power supply cord with this TOSHIBA RAC-PD1013CWRU air conditioner contains a current detection device designed to reduce the risk of fire.

In the event that the power supply cord is damaged, it can not be repaired. It must be replaced with a cord from the manufacturer.


What are important notices regarding the operation of the TOSHIBA RAC-PD1013CWRU portable air conditioner’s power supply cord?

Do not use this device to turn the unit on or off.

Always make sure the RESET button is pushed in for correct operation.

The power supply cord must be replaced if it fails to reset when either the TEST button is pushed, or it can not be reset.


What is the unit operating temperature range for the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Mode Temperature Range
Cool 62°F ~ 95°F (17°C ~ 35°C)
Dry 55°F ~ 95°F (13°C ~ 35°C)
Heat (heat pump models only) 41°F ~ 86°F (5°C ~ 30°C)
Heat (electrical heat mode) ≤ 86°F (30°C)

When should the exhaust hose be installed or removed for the TOSHIBA RAC-PD1013CWRU portable air conditioner?

The exhaust hose and adaptor must be installed or removed in accordance with the usage mode.

For COOL, HEAT (heat pump type) or AUTO mode, the exhaust hose must be installed.

For FAN, DEHUMIDIFY or HEAT (electric heat type) mode, the exhaust hose must be removed.


How do I use the Swing button on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

The Swing button is used to initiate the Auto Swing feature. When the operation is ON, pressing the SWING button can stop the louver at the desired angle.


How do I initiate wireless connection mode on smart TOSHIBA RAC-PD1013CWRU models?

To initiate the wireless connection mode, power on the TOSHIBA RAC-PD1013CWRU air conditioner then press the SWING button for 3 seconds. The LED DISPLAY will show ‘AP’ to indicate the unit is in wireless connection mode. If the connection is successful, the unit will exit wireless connection mode and illuminate the wireless LED. If the connection fails, the unit will exit wireless connection mode automatically after 8 minutes and the wireless LED does not illuminate.

The wireless connection process must be completed within 8 minutes after powering the TOSHIBA RAC-PD1013CWRU air conditioner on.


How do I use the Timer button on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

The Timer button is used to initiate the AUTO ON start time and AUTO OFF stop time program. The timer on or off light will illuminate depending on the selected setting.


How do I control the fan speed on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Press the Fan button to control the fan speed in four steps: LOW, MID, HIGH and AUTO. The selected fan speed light (except AUTO) will illuminate. When AUTO is selected, no lights will illuminate.

For models with the Constant Fan feature, in COOL or DRY mode, press the Fan button for 3 seconds to turn on or off the constant fan function. When the function is turned on, the constant fan light will illuminate, identifying the fan continuous run for cooling. When the function is turned off, the constant fan light will go out, identifying the fan cycle run with compressor stop.


How do I change the operating mode on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Press the Mode button to select the desired operating mode. Each time you press the button, a mode is selected in a sequence that goes from AUTO, COOL, DRY, FAN and HEAT (cooling only models excluded). The mode light illuminates and indicates the selected mode. To change between °F or °C, simultaneously press and hold the Up and Down buttons for 3 seconds.


How do I increase/decrease temperature settings and change between °F and °C on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Use the Up (A) and Down (✔) buttons to increase/decrease temperature settings in 1°F (or 2°F)/1°C increments in a range of 62°F/17°C to 86°F/30°C or the TIMER setting in a range of 0 to 24hrs.

To change between °F or °C, simultaneously press and hold the Up and Down buttons for 3 seconds.


How do I perform COOL operation with the TOSHIBA RAC-PD1013CWRU portable air conditioner?

1. Press the “MODE” button until the “COOL” indicator light comes on.

2. Press the ADJUST buttons Up (^) or Down (✔) to select your desired room temperature. The temperature can be set within a range of 62°F~86°F/17°C~30°C.

3. Press the “FAN SPEED” button to choose the fan speed.


How do I perform HEAT operation (if available) with the TOSHIBA RAC-PD1013CWRU portable air conditioner?

1. Press the “MODE” button until the “HEAT” indicator light comes on.

2. Press the ADJUST buttons Up (^) or Down (✔) to select your desired room temperature. The temperature can be set within a range of 62°F~86°F/17°C~30°C.

3. Press the “FAN SPEED” button to choose the fan speed. For some models, the fan speed cannot be adjusted while in HEAT mode.


How do I perform DRY operation with the TOSHIBA RAC-PD1013CWRU portable air conditioner?

1. Press the “MODE” button until the “DRY” indicator light comes on.

2. While in this mode, you cannot select a fan speed or adjust the temperature. The fan motor operates at LOW speed.

3. Keep windows and doors closed for the best dehumidifying effect.


How do I perform AUTO operation with the TOSHIBA RAC-PD1013CWRU portable air conditioner?

When you set the TOSHIBA RAC-PD1013CWRU air conditioner to AUTO mode, it will automatically select cooling, heating (cooling only models excluded), or fan only operation depending on what temperature you have selected and the current room temperature.

The air conditioner will control room temperature automatically according to the temperature point set by you.

Under AUTO mode, you cannot select the fan speed.


How do I perform FAN operation with the TOSHIBA RAC-PD1013CWRU portable air conditioner?

1. Press the “MODE” button until the “FAN” indicator light comes on.

2. Press the “FAN SPEED” button to choose the fan speed. The temperature cannot be adjusted.

3. Do not connect the duct to a window.


How do I use the Auto Start/Stop Timer on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

When the unit is on, pressing the Timer button will initiate the Auto stop program. The TIMER OFF indicator light illuminates. Press the Up (A) or Down (✔) button to select the desired time. Press the TIMER button again within 5 seconds. The Auto start program is initiated and the TIMER ON indicator light illuminates. Press the Up (A) or Down (✔) button to select the desired Auto start time.

When the unit is off, press the Timer button to initiate the Auto start program. Pressing it again within five seconds will initiate the Auto stop program.

Press or hold the Up (A) or Down (✔) button to change the Auto time by 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start.

The system will automatically revert back to display the previous temperature setting if there is no operation within 5 seconds.

Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop timer program.

Should a malfunction occur, the Auto Start/Stop timed program will also be cancelled.

When setting the TIMER ON or TIMER OFF functions, up to 10 hours, the time will increase in 30 minute increments with each press. After 10 hours and up to 24, it will increase in 1 hour increments. The timer will revert to zero after 24 hours. You can turn off either function by setting the timer to “0.0h”.


How does the SLEEP operation feature work on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Pressing this button will increase (during cooling operation) or decrease (during heating operation, applicable models) 1°F/1°C after 30 minutes. The temperature will again increase (cooling) or decrease (heating) by another 1°F/1°C after an additional 30 minutes. This new temperature will be maintained for 7 hours before returning to the originally selected temperature. This ends the Sleep mode and the unit will continue to operate as originally programmed.

The SLEEP operation feature is unavailable in FAN or DRY mode.


How do I use the MyTemp feature on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

This feature can ONLY be activated from the remote control. The remote control serves as a remote thermostat allowing for the precise temperature control at its location which must be within 26 feet of the TOSHIBA RAC-PD1013CWRU air conditioner. To activate the MyTemp feature, point the remote control towards the unit and press the MyTemp button. The remote’s display will show actual temperature at its location and must be within 26 feet of the air conditioner to work. The remote control will send this signal to the air conditioner every 3 minutes until the MyTemp button is pressed again. If the unit does not receive the MyTemp signal during any 7 minute interval, the unit will exit the MyTemp mode.

This feature is unavailable under FAN or DRY mode.


What happens if the TOSHIBA RAC-PD1013CWRU portable air conditioner shuts off unexpectedly due to a power outage?

If the TOSHIBA RAC-PD1013CWRU unit shuts off unexpectedly due to a power outage, it will restart with the previously set function automatically when the power resumes.


Why is there a 3-minute delay before the TOSHIBA RAC-PD1013CWRU portable air conditioner resumes operation after stopping?

After the unit has stopped, it cannot be restarted until 3 minutes time has elapsed. This is to protect the unit. Operation will automatically resume after 3 minutes.


How do I adjust the airflow direction on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

The louver can be adjusted automatically using the SWING button.

When the Power is ON, the louver opens fully.

Press the SWING button on the panel or remote controller to initiate the Auto Swing feature. The louver will swing up and down automatically.

Please do not adjust the louver manually.


How do I drain water from the TOSHIBA RAC-PD1013CWRU portable air conditioner during Dry modes?

During Dry modes, remove the upper drain plug from the back of the unit and install the drain connector (5/8″ universal female mender) with 3/4″ hose (locally purchased).

For models without drain connector, just attach the drain hose to the hole. Place the end of the hose directly in the drain area you’re using.


How do I drain water from the TOSHIBA RAC-PD1013CWRU portable air conditioner if it’s a Heat Pump model?

For Heat Pump models, remove the middle drain plug from the back of the unit and install the drain connector (5/8″ universal female adapter) with a 3/4″ hose (not included). For models without the drain connector, attach the drain hose to the connector. Place the end of the hose in the drain area you’re using. In Heat Pump mode, the drain hose can be elevated up to 6ft (1.8m). Direct the hose toward the drain, making sure that there are no kinks that will restrict water flow. Place the end of the hose into the drain and make sure the end of the hose is directed downward.


What should I do if the TOSHIBA RAC-PD1013CWRU portable air conditioner displays “P1” error code?

When the water level of the bottom tray reaches a predetermined level, the unit beeps 8 times. The digital display shows “P1.” At this time the air conditioning/dehumidification process will immediately stop. However, the fan motor will continue to operate (this is normal). Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain away. Reinstall the bottom drain plug and restart the machine until the “P1” symbol disappears. If the error repeats, call for service.


What are the requirements for choosing the right installation location for the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Your installation location should meet the following requirements:

Make sure that you install your TOSHIBA RAC-PD1013CWRU unit on an even surface to minimize noise and vibration.

The TOSHIBA RAC-PD1013CWRU unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible.

The TOSHIBA RAC-PD1013CWRU unit should be located at least 19.7″ (50cm) from the nearest wall to ensure proper air conditioning.

DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the TOSHIBA RAC-PD1013CWRU unit, as this could cause damage to the unit.


What tools are needed for installing the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Tools needed:

  • Phillips screwdriver
  • Tape measure or ruler
  • Knife or scissors
  • Saw (optional, to shorten window adaptor for narrow windows).

What accessories are included with the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Your Window Installation Kit fits windows 19.4″-62.2″ (49.3-158.1 cm).

Part Description Quantity
Unit adaptor 1 pc
Exhaust hose 1 pc
Air exhaust passage 1 pc
Bolt 3 pc
Window Sliders 4 pc
Foam seal A (adhesive) 4 pc
Foam seal B (adhesive) 2 pc
Foam seal C (Non-adhesive) 2 pc
Security bracket and 2 screws 1 set
Drain hose 1 pc
Drain hose adaptor (For heat pump mode only) 1 pc
Remote controller and battery (For remote control models only) 1 set
Power Cord Buckle 1 pc

How do I prepare the exhaust hose assembly for the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Press the exhaust hose into the Air exhaust passenger and unit adaptor, clamp automatically by elastic buckles of the adaptors.


How do I install the exhaust hose assembly to the TOSHIBA RAC-PD1013CWRU unit?

Insert the unit adapter side of the exhaust hose assembly into the groove of the air outlet on the back of the unit. Align the hook of the unit adapter with the seat on the air outlet and slide the assembly down until seated.

Make sure the adaptor is inserted into the lower groove of the air outlet.


How do I prepare the adjustable window slider for the TOSHIBA RAC-PD1013CWRU installation?

1. Depending on the size of your window, adjust the size of the window slider.

2. If the length of the window requires two or more window sliders, use the bolt to fasten the window sliders once they are adjusted to the proper length.


How do I install the TOSHIBA RAC-PD1013CWRU in a hung window?

1. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown.

2. Insert the window slider assembly into the window opening.

3. Cut the non-adhesive foam seal C strip to match the width of the window. Insert the seal between the glass and the window frame to prevent air and insects from getting into the room.

4. If desired, install the security bracket with 2 screws as shown.

5. Insert the window slider adaptor into the hole of the window slider.


How do I install the TOSHIBA RAC-PD1013CWRU in a sliding window?

1. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown.

2. Insert the window slider assembly into the window opening.

3. Cut the non-adhesive foam seal C strip to match the window height. Insert the foam seal between the glass and the window frame to prevent air and insects from getting into the room.

4. If desired, install the security bracket with 2 screws as shown.

5. Insert the window slider adaptor into the hole of the window slider.


What is an important notice regarding the exhaust hose for the TOSHIBA RAC-PD1013CWRU portable air conditioner?

To ensure proper function, DO NOT overextend or bend the hose. Make sure that there are no objects within 20in (~500mm) of the exhaust hose.


What safety precautions should I take before cleaning or servicing the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Always unplug the TOSHIBA RAC-PD1013CWRU unit before cleaning or servicing.

DO NOT use flammable liquids or chemicals to clean the unit.

DO NOT wash the unit under running water. Doing so causes electrical danger.

DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.


How do I clean the air filter of the TOSHIBA RAC-PD1013CWRU portable air conditioner?

To clean the air filter, first take out the upper filter, then take out the lower filter, and finally remove the air filter.

For model RAC-PD1013CWRU, the air filters are built into and part of the rear grill.

DO NOT operate the unit without filter because dirt and lint will clog it and reduce performance.

Be sure to clean the air filter every 2 weeks for optimal performance.


How do I clean the TOSHIBA RAC-PD1013CWRU portable air conditioner unit?

Clean the unit using a damp, lint-free cloth and mild detergent. Dry the unit with a dry, lint-free cloth.


How should I store the TOSHIBA RAC-PD1013CWRU portable air conditioner when not in use?

Drain the unit’s water collection tray according to the instructions in the drainage section.

Run the unit on FAN mode for 12 hours in a warm room to dry it and prevent mold.

Turn off the unit and unplug it.

Clean the air filter according to the instructions in the previous section. Reinstall the clean, dry filter before storing.

Remove the batteries from the remote control.

Be sure to store the unit in a cool, dark place. Exposure to direct sunlight or extreme heat can shorten the lifespan of the unit.


What do the error codes and protection codes mean on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

E1: Room temperature sensor error.

E2: Evaporator temperature sensor error.

E3: Condenser temperature sensor error (select models).

E4: Display panel communication error.

P1: Bottom tray is full. Connect the drain hose and drain the collected water away. If protection code repeats, call for service.

When one of the above malfunctions occurs, turn off the unit and check for any obstructions. Restart the Unit. If the malfunction persists, turn off the unit and unplug the power cord.


How to troubleshoot common issues with the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Problem Solution
TOSHIBA RAC-PD1013CWRU unit does not turn on when pressing ON/OFF button Displays P1 Error Code and means the water collection tray is full. Turn off the unit, drain the water from the water collection tray, and restart the unit. If room temperature is lower than the set temperature in COOL mode, reset the temperature.
TOSHIBA RAC-PD1013CWRU unit does not cool well The air filter is blocked with dust or animal hair. Turn off the unit and clean the filter according to the instructions. Exhaust hose is not connected or is blocked. Turn off the unit, disconnect the hose, check for blockage and reconnect the hose. Temperature setting is too high; decrease the set temperature. Make sure all windows and doors are closed. The room area could be too large; doublecheck the cooling area. Check the room for possible heat sources and remove them if possible.
The TOSHIBA RAC-PD1013CWRU unit is noisy and/or vibrates too much The floor is not level. Place the unit on a flat, level surface. The air filter is blocked with dust or animal hair. Turn off the unit and clean the filter according to the instructions.
The TOSHIBA RAC-PD1013CWRU unit makes a gurgling sound This sound is caused by the refrigerant flow inside the unit and is normal.

Can I add an extension to the exhaust hose(s) of the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Do not add extension to the exhaust hose(s)!


What are the specifications of the remote control for the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Model RG57H4(B)/BGEFU1
Rated voltage 3.0V (Dry batteries R03/LR03x2)
Signal receiving range 26 ft. (approx. 8 m)
Environment 23°F ~ 140°F (-5°C ~ 60°C)

How do I set the desired temperature using the remote control for the TOSHIBA RAC-PD1013CWRU portable air conditioner?

The operating temperature range for the TOSHIBA RAC-PD1013CWRU unit is 62°F-86°F (17-30°C). You can increase or decrease the set temperature in 1°F or 1°C increments.


How do I change the operating mode using the remote control for the TOSHIBA RAC-PD1013CWRU portable air conditioner?

1. To change the operating mode, press the MODE button until the desired mode appears on the remote’s display.

2. Set the desired temperature.

If the unit does not change when the button is pressed, check that the ON/OFF indicator is illuminated. If it is not, point the remote at the unit and press the ON/OFF button.


How do I change the fan speed using the remote control for the TOSHIBA RAC-PD1013CWRU portable air conditioner?

To change the fan speed, press the FAN button until the desired fan speed appears on the remote’s display.

If the unit does not change when the button is pressed, check that the ON/OFF indicator is illuminated. If it is not, point the remote at the unit and press the ON/OFF button.


How do I insert or replace batteries in the TOSHIBA RAC-PD1013CWRU remote control?

Your TOSHIBA RAC-PD1013CWRU air conditioning unit comes with two AAA batteries. Insert the batteries in the remote control before use.

1. Slide the back cover of the remote control downward, exposing the battery compartment.

2. Insert the batteries, paying attention to align the (+) and (-) ends of the batteries with the symbols inside the battery compartment.

3. Slide the battery cover back into place.


What are important notes about using batteries with the TOSHIBA RAC-PD1013CWRU remote control?

For optimum product performance:

Do not mix old and new batteries, or batteries of different types.

Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.

Ensure used batteries are disposed of properly.


What tips should I follow when using the TOSHIBA RAC-PD1013CWRU remote control?

The remote control must be used within 26 feet / 8 meters of the unit.

The TOSHIBA RAC-PD1013CWRU unit will beep when it receives a signal from the remote. Curtains, other materials and direct sunlight can interfere with the IR signal receiver.

In order to properly transmit a command, the ON/OFF indicator must be illuminated on the remote’s display.


How do I set the TIMER ON function on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

The TIMER ON function allows you to set a period of time after which the TOSHIBA RAC-PD1013CWRU unit will automatically turn on, such as when you come home from work.

1. Press the TIMER ON button. By default, the last time period that you set and an “h” (indicating hours) will appear on the display.

2. Press the TIMER ON button repeatedly to set the time that you want the unit to turn on.

3. Wait 2 seconds, then the TIMER ON function will be activated. The digital display on your remote control will then return to the temperature display.

This number indicates the amount of time after the current time after which you want the unit to turn on. For example, if you set TIMER ON for 2 hours, “2.0h“ will appear on the screen, and the TOSHIBA RAC-PD1013CWRU unit will turn on after 2 hours.


How do I set the TIMER OFF function on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

The TIMER OFF function allows you to set a period of time after which the TOSHIBA RAC-PD1013CWRU unit will automatically turn off, such as when you wake up.

1. Press the TIMER OFF button. By default, the last time period that you set and an “h” (indicating hours) will appear on the display.

2. Press the TIMER OFF button repeatedly to set the time that you want the unit to turn off.

3. Wait 2 seconds, then the TIMER OFF function will be activated. The digital display on your remote control will then return to the temperature display.

This number indicates the amount of time after the current time after which you want the unit to turn off. For example, if you set TIMER OFF for 2 hours, “2.0h“ will appear on the screen, and the TOSHIBA RAC-PD1013CWRU unit will turn off after 2 hours.


How do I set both TIMER ON and TIMER OFF functions at the same time on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

Keep in mind that the time periods you set for both functions refer to hours after the current time. For example, say that the current time is 1:00 PM, and you want the TOSHIBA RAC-PD1013CWRU unit to turn on automatically at 7:00 PM and want it to operate for 2 hours, then automatically turn off at 9:00 PM. You would set the TIMER ON for 6 hours (from 1 PM to 7 PM) and the TIMER OFF for 8 hours (from 1 PM to 9 PM).


How do I use the SHORTCUT Function on the TOSHIBA RAC-PD1013CWRU portable air conditioner?

The SHORTCUT Function is used to restore the current settings or resume previous settings.

Push this button when the remote controller is on, the system will automatically revert back to the previous settings including operating mode, setting temperature, fan speed level and sleep feature (if activated).

By pressing for more than 2 seconds, the system will automatically store the current operation settings including operating mode, setting temperature, fan speed level and sleep feature (if activated).


What devices are required to use the Smart AC features of the TOSHIBA RAC-PD1013CWRU?

Devices required to use the Smart AC:

1. Smart Phone with compatible iOS or Android system.

2. Wireless Router (a 2.4GHz network is required to connect)

3. Smart TOSHIBA RAC-PD1013CWRU Air Conditioner


What are the precautions for using the app with the TOSHIBA RAC-PD1013CWRU portable air conditioner?

The app supports operating systems: iOS 7+ or Android 4+.

In the event of an OS update, there may be a delay between the update of the OS and a related software update during which your OS may or may not be supported until a new version is released. Your specific mobile phone or problems in your network can prevent the system from working.

The Smart AC only supports WPA-PSK/WPA2-PSK (recommended) encryption.

To ensure proper scanning of the QR code, your smart phone must have at least a 5-megapixel camera.

Due to unstable network connectivity, requests may time out. If this happens, re-run the network configuration.

Due to unstable network connectivity, commands may time out. If this happens, the smartphone app and the actual product may display conflicting information. The information displayed on the actual product is always the most accurate available. Refresh the app to re-sync.


How do I create an account for the TOSHIBA RAC-PD1013CWRU app?

Make sure your smartphone is connected to your wireless router and your wireless router has a working 2.4GHz internet connection.

It is recommended to activate your account immediately to be able to recover your password by email.

1. Press “Sign Up”.

2. Enter your email address and password.

3. Press “Registration”.

4. If you forget your password, press “Forgot password?” on the main menu and enter your email address. Then press “Reset Password”.

Make sure your smartphone is able to connect to the wireless network which will be used. Make sure also that the device is not connecting to other networks in range.


CLICK HERE TO DOWNLOAD TOSHIBA RAC-PD1013CWRU (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.