What safety precautions should be taken before installing the TOPGREENER TWOS5 occupancy sensor switch?

Before installation, please read and understand the following safety instructions:

1. This device is intended for installation in accordance with the National Electrical Code and local regulations. It is recommended that a qualified electrician perform this installation.

2. Make sure to turn off the circuit breaker or fuse(s) and test that the power is off before wiring the device.

3. Please check the junction box for a neutral wire. This switch requires a neutral wire in the junction box for it to work properly.


How do I install the TOPGREENER TWOS5 occupancy sensor switch?

Follow these steps to install your TOPGREENER TWOS5:

1. Connect the lead wires according to the wiring diagram: Black lead to Line(Hot), Red lead to Load wire, White lead to Neutral wire, and Green lead to Ground.

2. Gently position the wires in the wall box and attach the sensor switch to the box.

3. Mount the device with the “TOP” indicator facing up.

4. Restore power at the circuit breaker or fuse and wait one minute for the device to initialize.

5. Remove the small cover plate to access the adjustment knobs.

6. Locate the adjustment knobs on the control panel to perform tests and adjustments.

7. Replace the small cover plate after you have completed testing and adjustments.

8. Attach the wallplate.


How do I properly wire the TOPGREENER TWOS5 switch?

To wire the TOPGREENER TWOS5, follow this connection guide:

Black Lead: Connect to the Hot (Line) wire.

Red Lead: Connect to the Load wire.

White Lead: Connect to the Neutral wire.

Green Lead: Connect to the Ground wire.


How do I adjust the Time Delay on the TOPGREENER TWOS5?

The Time Delay knob controls how long the load stays on after no motion is detected.

Default Position: 15 Seconds (Test mode).

Adjustment: The time delay is adjustable from 15 seconds to 30 minutes. Turn the knob clockwise to increase the time delay.


How do I adjust the Sensor Sensitivity Range on the TOPGREENER TWOS5?

The Sensor Sensitivity Range knob adjusts the detection area of the sensor.

Default Position: Center at 65%.

Adjustment: The sensitivity is adjustable from 30% (Position 1) to 100% (Position 4).

Turn the knob toward the right for greater room space.

Turn the knob toward the left to avoid false alerts in a smaller room and when the switch is near a doorway or heat source.


How do I adjust the Ambient Light Level on the TOPGREENER TWOS5?

The Ambient Light Level knob determines how bright the room must be for the switch to remain off, even when motion is detected, to save energy.

Default Position: Daylight (100% at position 4).

Adjustment: The level is adjustable from Daylight down to 30 Lux. Turn the knob counter-clockwise to make the sensor activate in darker conditions. This feature helps to avoid wasting energy by turning on the light during the day.


What are the functions of the band switch modes on the TOPGREENER TWOS5 (TSOS5 model)?

The TSOS5 model features a 3-position band switch with the following functions:

Mode Position Description
OFF (Left) The circuit is permanently opened (switched off).
AUTO (Center) Occupancy Mode: The load turns On automatically when occupancy is detected and turns Off automatically after the set time delay.
ON (Right) The load stays On always.

How does the push-button work on the TOPGREENER TWOS5 (TWOS5 model)?

The push-button on the TWOS5 model functions as follows:

Switched OFF: When the button is pushed in and locked, the Load stays Off.

AUTO Mode: When the button is pressed and released, it returns to the AUTO (Occupancy) mode.


What should I expect during the initial run of the TOPGREENER TWOS5?

The TOPGREENER TWOS5 sensor switch requires an initial run of one minute after power is restored. During this initial run, the load may turn on and off several times. Do not adjust any settings until the initial one-minute run is completed.


Why is the load on my TOPGREENER TWOS5 out of control or frequently flashing?

If the load connected to your TOPGREENER TWOS5 is frequently flashing or seems out of control, please check the following:

1. The switch can take up to one minute for its initial run. Allow this process to complete.

2. Check the wiring connections, especially the Neutral Wiring, to ensure it is secure.


What should I do if the load on my TOPGREENER TWOS5 doesn’t turn on when motion is detected?

If the load does not turn on with motion, try these troubleshooting steps:

1. Check to see if the Ambient Light Level setting is preventing activation. Cover the sensor lens with your hand to simulate darkness. If the light turns on, the ambient light level is correct and the room is too bright for activation.

2. Check the wiring connections, especially the Hot and Neutral wiring, and make sure there is no loose wiring.


Why won’t the load on my TOPGREENER TWOS5 turn off?

If the load connected to the TOPGREENER TWOS5 does not turn off, follow these steps:

1. For the TSOS5 model, make sure the switch is in the ‘AUTO’ mode.

2. There can be up to a 30-minute time delay after the last motion is detected. To verify proper operation, turn the Time Delay Knob to the 15s (Test Mode) setting. Ensure there is no motion in the area. The load should turn off in 15 seconds.

3. Check if there is any significant heat source within six feet (two meters) that may cause false detection, such as a high wattage light bulb, portable heater, or an HVAC device.

4. Check the wiring connections, especially the Neutral wiring to the sensor switch, to ensure they are secure.


Why does the load on my TOPGREENER TWOS5 turn on when there is no motion?

If the load turns on without any apparent motion, it may be due to false triggers. Try the following solutions:

1. Mask the Sensor Switch’s lens to eliminate unwanted coverage area, such as a hallway or adjacent room.

2. Turn the Sensitivity Level knob to the left (counter-clockwise) to reduce its range. This helps avoid false alerts in smaller rooms and if the switch is installed near a doorway.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD TOPGREENER TWOS5 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.