How do I start the assembly of the 7 Gal. Independent Sprayer Attachment?

STEP 1: Disconnect the battery, ground first and then power wire.

STEP 2: Remove existing storage container and support bracket from the frame. Note: Steps 2 & 3 instructions are the same for the right and left side, if both left & right side tanks are being installed.


How do I install the independent sprayer unit to the frame?

STEP 3: Install the independent sprayer to the frame as shown using Carriage bolts CB-51634 qty. (4) and Hex nuts HFNCS-516S qty. (4).

How do I prepare the panel and install the rocker switch?

STEP 4: Use an exacto or utility knife and cut out the appropriate “Aux” opening in the panel (Right Side Pump or Left Side Pump).

STEP 5: Attach the rocker switch to the appropriate opening.


How do I wire the pump harness and install fuses?

STEP 6:

• Connect the pump harness to the pump switch.

• Connect the second harness if equipped with both left & right 7 gal. attachments.

• Left tank equipped, connect the orange power wire to port 3 on the fuse block.

• Right tank equipped, connect the orange power wire to port 4 on the fuse block.

• Connect the ground wire to the ground block.

• If equipped with left & right, Connect the ground wire from the second harness right side to the ground block.

• Attach the proper fuses according to the chart Fig. 1.

• Attach the clear cover to the fuse block.


What are the fuse specifications for the SG 52 Series Fuse Block?

Fig. 1: SG 52 SERIES FUSE BLOCK

PORT COMPONENT FUSE PORT COMPONENT FUSE
1 SPRAY PUMP 1 25 AMP 6 USB PORT 5 AMP
2 SPRAY PUMP 2 25 AMP 7 SPRAY PUMP SWITCH 25 AMP
3 7 GAL. LEFT 25 AMP 8 SPEEDOMETER 1 AMP
4 7 GAL. RIGHT 25 AMP 9 FOAM MARKER 25 AMP
5 HSA 10 AMP 10 HEADLIGHT 10 AMP

How do I complete the wiring connections for the sprayer attachment?

STEP 7: Connect the plug on the harness to the pump on the 7 gallon tank.

STEP 8: Reconnect the battery power wire first along with the pump power wire from the wiring harness, and then reconnect the ground wire.


How do I operate the 7 Gal. Independent Sprayer?

OPERATION

STEP 1: Press the switch on the dash to power the pump “on”.

STEP 2: Turn the knob on the throttle valve to adjust the spray pressure.

STEP 3: Squeeze the trigger on the spray handle to spray.


How do I perform maintenance on the sprayer’s strainer?

MAINTENENCE

• Turn the ball valve off to stop the fluid flow.

• Remove the cap from the strainer to clean it.