STARRETT SR100 (01) PDF MANUAL


Post questions, comments, reviews or errors in the comment box below.

Your File is Ready … Download PDF

CLICK HERE TO DOWNLOAD STARRETT SR100 (01) PDF MANUAL


PDF Content Summary: SR100 Surface Roughness Tester Operating Guide Mode status Display Parameter Status Parameter Selector Mode Selector

ArDA Windows Stylus Start Buttons Traverse Unit Control Unit ON Button

Inserting Getting Started the Batteries Storage. The SR100 is supplied with the Remove battery covers as shown. Then, Traverse Unit (bottom) connected to the insert one 3V Lithium 2450 in to the Control Control Unit (top). Before use, separate the Unit and three 3V Lithium 2450s in to the Traverse Unit from the Control Unit. Traverse Unit as shown. Note: To prevent damage to the stylus, store the SR100 with the units connected. Then replace the battery covers. After the batteries have been changed, there will be a short delay when the SR100 is turned on. The SR100 can be operated in two modes: Remote or Connected. Remote: Position the Control Unit within 40" (1 meter) of the Traverse Unit. Data is passed between the two units over the IrDA link. Note: Alignment between the Traverse Unit and Control Turning On the SR100 When the Control Unit is not used for five minutes or more, it enters power save mode, turning the display off. Press any button to reactivate. Unit separation μmμin +- must be maintained during the measurement process. Connected: In connected mode, Ra Rz Rv Rp Rt the Control Unit is connected to the Traverse Unit before the measure- ment is made, as shown. To connect the Control Unit to the Traverse Unit, insert the Control Unit as shown and The Traverse Unit switches off com- pletely after five minutes of inactivity. To reactivate, press the On button. An LED will flash to confirm activation. tilt until the latch engages. Caution: - Use recommended batteries only. - Do not atttempt to recharge used batteries. Control Unit - Safely dispose of used batteries To separate, press here and tilt the Traverse Unit as shown Traverse Unit Position the Traverse Unit on the surface as shown Max. 40" (1 meter) separation

Low Battery Indicators Set Up Procedure A new SR100 is fully set up out of the box. However, if the pick-up is changed or another alteration is made, field setup may be required using the following procedure: Press the On button on the Traverse Unit. Position the traverse unit on the calibration standard in the correct orientation. First, press both selector buttons simultaneously and then press the right hand start button while still pressing both selector buttons. The display will go through the following sequence over a 50 second period. The control unit must remain pointed at the traverse unit during this entire cycle. Five values are stored and can be viewed by toggling the Selector button as follows: 1: Gain pot setting 2: Rz value (21.5 ±10%) 3: Speed pot setting 4: Rp value (Profile period signal (68 ±2%) 5: Can be ignored for this procedure Note: If a setup error occurs, the procedure terminates and an E code is transmitted and displayed in the Control Unit (see E codes). Calibrating the Gage Position the Traverse Unit to measure the Cali- μmμin +- μmμin +- bration Standard included with the SR100 (DO NOT use other standards). Press Mode Se- lect (on the Control Unit) until is indicated on Mode status. Ra Rz Rv Rp Rt Ra Rz Rv Rp Rt Press the Start button on the Control Unit to ini- tiate the gage calibration procedure. The result will be display the Control Unit. The Ra value should be 5.81μm and the Rz value 21.5μm. If there is an error, an E code is displayed (see E Codes). Measuring Operation of the Control Unit is identical in either the Connected or Remote mode. Position the Traverse Unit on the surface to be meas- ured, then press Select on the Control Unit to select the parameter to be displayed upon completion of the measurement. Select either English or metric units with the Mode button. If in remote mode, be sure to maintain line of sight of the infrared transceiv- ers during the measurement. Press either Start button to begin the measure- ment. The “measure- ment in progress” display is shown. The measured parameter is displayed as shown. If there is an error, the appropriate E code is displayed (see E Codes). All parameters (not just the selected param- eter) are transmitted to the Control Unit at the same time and temporarily stored. The stored results may then be stepped through using the select buttons. μin +- Control Unit Traverse Unit μmμin +- Ra Rz Rv Rp Rt μmμin +- μmμin +- Ra Rz Rv Rp Rt Ra Rz Rv Rp Rt μmμin +- Ra Rz Rv Rp Rt Specifications Traverse length: 0.2" (5mm) Measurement length: 0.16" (4mm) Traverse speed: 0.08in/s (2mm/s) Gauge range: 8000μin (200μm) Gauge resolution: 2μin (0.05μm) Display resolution: Ra. 0.4μin (0.01μm) Display resolution: 1μin (0.1μm) for Rz, Rt, Rp, Rv Cut off: 0.03" (0.8mm) ±15% Uncertainty: 4μin (0.1μm) or 5% of result, to 95% confidence level Results range: Ra. 1600μin (40μm) (See ISO 4288-1996) Results range: Rz, Rt, Rp, Rv. 8000μin (199.9μm) (See ISO 4288-1996) Stylus: Diamond. Radius: 123μin (5μm) nominal, 90o tip angle. Skid radius: .394" (10mm) nominal. Filter type: 2CR, (200:1) Sample spacing: .025μin (1um) Stylus Force: 1gf (10mN) max at mid range Batteries: Control Unit: (1) 3V Lithium 2450 Traverse Unit: (3) 3V Lithium 2450 Units: μin or μm Operating conditions: 50-95oF (10-35oC) 80% RH non-condensing Size: 4.92 x 3.15 x 1.5" (125 x 80 x 38mm) Weight: 7oz (200g) Error Codes E1: Infra Red communication error. Repeat operation. E2: Measurement attempted when not calibrated. Calibrate the Traverse Unit. E3: Traverse Unit - Oscillator fault. Retry. If fault is persistent, contact Starrett E4: Traverse Unit - Motor Positioning fault. Retry. If fault is persistent, contact Starrett E5: Traverse Unit - NVRAM Error. Retry. If fault is persistent, contact Starrett E6: Traverse Unit - Profile Over-range. Retry measurement. E7: Traverse Unit - Parameter Over-range. Retry measurement. E8: Traverse Unit - Motor Speed Setup error. Retry Set up procedure. E9: Traverse Unit - Gain Setup error. Retry Set up procedure. E10: Control Unit - Oscillator fault. Retry. If fault is persistent, contact Starrett E11: Traverse Unit - Calibration information download error. Try again. E12: Traverse Unit - Not set up. Run the Set up procedure. E13: <Reserved> E14: Traverse Unit - Electronic Measurement er- ror. Retry. If fault is persistent, contact Starrett The L.S. Starrett Company 121 Crescent Street, Athol, MA 01331 978-249-3551 Form 964 04/11 2.5C/T 978-249-3551 starrett.com


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE - USER MANUAL

OWNER GUIDE - OWNER MANUAL

REFERENCE GUIDE - REFERENCE MANUAL

INSTRUCTION GUIDE - INSTRUCTION MANUAL

Leave a Reply