What are the essential installation and safety guidelines for the SOLAHD GLT24 power supply?
To comply with published safety standards when using the SOLAHD GLT24, the following must be observed:
1. The maximum ambient temperature for the power supply must not exceed 50°C.
2. When installing in end-use equipment, ensure compliance with safety standards UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03, including requirements for creepage distances, clearances, and insulation distance between primary and secondary wiring.
3. The rated input voltage is automatically selected. Refer to the specification sheet for the specific input voltage range.
4. The maximum output power must not exceed the rating indicated in the specification sheet.
5. The earth ground wire must only be connected to the point marked with the earth ground symbol on the unit.
6. Disconnect the power supply before servicing as hazardous voltages exist in the primary circuits.
7. When operating with a DC input voltage, the input must be protected by a DC-rated fuse in the end-use installation.
8. This equipment is considered Class I according to protection against electric shock.
What type of internal fuse is required for the SOLAHD GLT24 and what are the replacement models?
The internal fuse for the SOLAHD GLT24 should only be replaced with a 2.5 A, 250 V ac fuse. Acceptable replacement types are:
• SP0001.1008 manufactured by Schurter AG
• 21602.5 manufactured by Littelfuse
What are the input specifications for the SOLAHD GLT24 power supply?
The input specifications for the SOLAHD GLT24 are as follows:
Input range: 85-264 Vac; 120-300 Vdc
Frequency: 47-440 Hz
Inrush current: <15 A peak @ 115 Vac; <30 A peak @ 230 Vac, cold start @ 25°C
Input current: 1 A max. (RMS) @ 115 Vac
Efficiency: 70% typical at full load
EMI filter: FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted
Safety ground leakage current: <0.5 mA @ 50/60 Hz, 264 Vac input
What are the general output specifications for the SOLAHD GLT24?
The general output specifications are:
Maximum power: 25 W for convection cooling; 40 W with 30 CFM forced air.
Cross regulation: ±2% on output 1; ±5% on outputs 2, 3.
Adjustment range: -5, +10% minimum.
Hold-up time: 20 ms @ 25 W load, 115 Vac nominal line.
Overload protection: Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating.
Overvoltage protection: 5.7 to 6.7 Vdc on the main output.
Minimum Load: 0.3 A on the first output, 0.1 A on the second output.
Remote Sense: Compensates for 0.5 V lead drop minimum. Will operate without remote sense connected. Reverse connection protected.
What are the specific output voltage and current ratings for the SOLAHD GLT24?
The output ratings for the SOLAHD GLT24 model vary based on the cooling method:
| Cooling Method | Output Voltage (V) | Max. Output Current (A) | Max. Output Power (W) |
|---|---|---|---|
| Convection Cooling | +5 | 3.0 | 25 |
| +12 | 1.5 | ||
| -5 | 0.5 | ||
| 30 CFM Forced Air Cooling | +5 | 4.0 | 40 |
| +12 | 2.0 | ||
| -5 | 0.7 |
What are the connector pin designations for the SOLAHD GLT24?
The pin designations for the connectors on the SOLAHD GLT24 are as follows:
Input Connector (SK1)
| PIN | Designation |
|---|---|
| 1 | Line |
| 3 | Neutral |
Output Connector (SK2)
| PIN | Designation for GLT24 |
|---|---|
| 1 | +12 V |
| 2 | +5 V |
| 3 | – |
| 4 | Common |
| 5 | -5 V |
| 6 | – |
Sense Connector (SK201)
| PIN | Designation |
|---|---|
| 1 | +Sense |
| 2 | -Sense |
What are the specified mating connectors for the SOLAHD GLT24?
The mating connectors for the SOLAHD GLT24 are:
AC Input:
Molex 09-50-8031 (USA) or 09-91-0300 (UK)
PINS: 08-52-0113
DC Outputs:
Molex 09-50-8061 (USA) or 09-91-0600 (UK)
PINS: 08-52-0113
Remote Sense:
Molex 22-01-2025
PINS: 08-52-0123
What are the environmental and physical specifications for the SOLAHD GLT24?
The environmental and physical specifications are:
Operating temperature: 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C. -20°C start up.
Storage temperature: -40°C to 85°C
Temperature coefficient: ±.04% per °C
Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing 5% to 95%
Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational
MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions
Weight: 0.5lb / 0.23kg
How does the output power of the SOLAHD GLT24 derate based on ambient temperature?
The maximum output power of the SOLAHD GLT24 must be derated for ambient temperatures above 50°C. The derating is as follows:
Natural Convection Cooling: The unit can provide up to 25 W of power from 0°C to 50°C. Above 50°C, the power derates linearly to 12.5 W at 70°C.
30 CFM Forced Air Cooling: The unit can provide up to 40 W of power from 0°C to 50°C. Above 50°C, the power derates linearly to 20 W at 70°C.
What are the mechanical dimensions of the SOLAHD GLT24 power supply?
The mechanical dimensions for the SOLAHD GLT24 are provided in inches [mm]:
Overall Length: 5.00 [127.0]
Overall Width: 3.00 [76.2]
Maximum Height: 1.08 [27.5]
Mounting Hole Pattern (Length): 4.55 [115.6]
Mounting Hole Pattern (Width): 2.55 [64.8]
Mounting Hole Diameter: 0.15 [3.81] (4 places)
What is the purpose of the mounting holes on the SOLAHD GLT24?
Mounting holes M1 and M2 on the SOLAHD GLT24 should be grounded for EMI purposes. Additionally, mounting hole M1 serves as an earth ground connection for safety.
What is the reference fan model for the forced air cooling setup for the SOLAHD GLT24?
For the typical ventilation setup requiring 30 CFM forced air cooling, the reference fan is:
Fan Model: MINEBEA 3110NL-04W-B30
Fan Input: 12 V dc
NOTE: The dimensions and fan model provided are for reference only.