Free English SINGER SYSTEM TEN 4310 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD SINGER SYSTEM TEN 4310 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.


How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.


What is the function of the SINGER SYSTEM TEN 4310 SCA Module?

The SINGER SYSTEM TEN 4310 SCA Module provides communications support allowing a user application program to communicate with a magnetic data recording system terminal. It provides device-specific routines designed to interface with the terminal tape drive and line printer.


Which device-specific routines are provided in the SINGER SYSTEM TEN 4310 SCA Module?

Two device-specific routines are provided: the SINGER SYSTEM TEN 4310 Read Routine and the SINGER SYSTEM TEN 4310 Write Routine.


What standard routines are compatible with the SINGER SYSTEM TEN 4310 Read and Write Routines?

The SINGER SYSTEM TEN 4310 Read and Write Routines are compatible with any versions of the standard SCA Handshaking, Initialization, Get-Buffer, and Error Routines.


What is the function of the SINGER SYSTEM TEN 4310 Read Routine?

The SINGER SYSTEM TEN 4310 Read Routine receives data transmitted from the tape drive of the terminal.


Why does the SINGER SYSTEM TEN 4310 Read Routine omit sequence and length checks?

Because the terminal does not generate sequence and length fields in the data blocks it transmits, the SINGER SYSTEM TEN 4310 Read Routine removes the standard sequence and length checking logic. This omission has no effect on user application program design.


What is the function of the SINGER SYSTEM TEN 4310 Write Routine?

The SINGER SYSTEM TEN 4310 Write Routine transmits data to either the tape drive or the line printer of the terminal.


In what three ways does the SINGER SYSTEM TEN 4310 Write Routine differ from the standard Write Routine?

1. Sequence and length fields are omitted from transmission blocks because the terminal cannot perform sequence and length checking.

2. A Temporary Text Delay line control sequence is sent instead of an IDLE message when no Transmit Buffers are ready.

3. It provides remote device selection logic, allowing the application program to designate whether data is transmitted to the tape drive or line printer.


How does the SINGER SYSTEM TEN 4310 handle situations where no Transmit Buffers are ready?

The SINGER SYSTEM TEN 4310 Write Routine transmits a Temporary Text Delay line control sequence (STX ENQ) rather than sending an IDLE message. The terminal is expected to return a NAK in response to each sequence.


What happens when the SINGER SYSTEM TEN 4310 transmits 100 consecutive Temporary Text Delay sequences without finding a ready buffer?

If the SINGER SYSTEM TEN 4310 Write Routine sends a Temporary Text Delay and receives a NAK response 100 consecutive times without finding an available ready Transmit Buffer, it terminates the attempt by sending an EOT, posting an R in the Inhibit Switch, and returning control to the Handshaking Routine.


What are the core memory requirements for the SINGER SYSTEM TEN 4310 routines?

The core storage requirements for the device-specific routines are listed below:

Routine Core Required
SINGER SYSTEM TEN 4310 Read Routine 950
SINGER SYSTEM TEN 4310 Write Routine 1080

How is a SINGER SYSTEM TEN 4310 SCA Module created?

To create the module, assemble the SINGER SYSTEM TEN 4310 Read Routine, the SINGER SYSTEM TEN 4310 Write Routine, or both, alongside the application-appropriate versions of the standard Handshaking, Initialization, Get-Buffer, and Error Routines.


What does the Inhibit Switch code R signify in the SINGER SYSTEM TEN 4310?

In the SINGER SYSTEM TEN 4310, code R is posted in the Inhibit Switch when 100 consecutive Temporary Text Delay sequences have been transmitted without a ready Transmit Buffer being supplied by the user application program, after which an EOT is sent and the module returns to the Handshaking Routine.


Which Partition Status Byte codes do not occur on the SINGER SYSTEM TEN 4310?

The following three Partition Status Byte codes are not applicable when communicating with the terminal and will not occur:

E: Length error

F: Sequence error

T: Transmission interrupt

All other standard Partition Status Byte codes may occur.


How is the System Mailbox used with the SINGER SYSTEM TEN 4310?

The definition and use of the System Mailbox during initialization are completely unchanged for the SINGER SYSTEM TEN 4310.


What changes are made to the Transmit Buffer Prefix for the SINGER SYSTEM TEN 4310?

Because sequence number and length control fields are not generated by the SINGER SYSTEM TEN 4310 Write Routine, relative locations 12 through 19 of the Transmit Buffer Prefix are modified to shift unused and synchronization fields.


What is the field layout of the SINGER SYSTEM TEN 4310 Transmit Buffer?

The layout and byte positions of the SINGER SYSTEM TEN 4310 Transmit Buffer are defined as follows:

Relative Locations Field Name
0 Buffer Status Byte
1 – 2 To-Address
3 – 4 From-Address
5 – 8 Data Length
9 Write Flag
10 – 15 Unused
16 – 18 Synchronization Characters (SYNs)
19 STX or SOH
20+ Data

What is the maximum data block size allowed when transmitting to the SINGER SYSTEM TEN 4310?

The total number of data characters plus control sequence characters in a single data block must not exceed 200 characters. If the RECORD LENGTH switch on the terminal is set below 200, the maximum number of characters allowed is reduced accordingly.


What is the layout of the SINGER SYSTEM TEN 4310 Receive Buffer?

The field layout of the SINGER SYSTEM TEN 4310 Receive Buffer is formatted as follows:

Relative Locations Field Name
0 Buffer Status Byte
1 – 2 To-Address
3 – 4 From-Address
5 – 8 Data Length
9 – 18 Unused
19 STX
20+ Data
End of block ETB or ETX

What character is stored in relative location 19 of the SINGER SYSTEM TEN 4310 Receive Buffer?

Relative location 19 of the SINGER SYSTEM TEN 4310 Receive Buffer will always contain an STX character after a data block has been received, because the terminal cannot send an SOH.


How is the IDLE Message Buffer utilized in the SINGER SYSTEM TEN 4310?

Although the SINGER SYSTEM TEN 4310 Write Routine does not transmit IDLE messages, the IDLE Message Buffer definition must be retained for assembly. The buffer area is available for application program use unless Dial-Out Handshaking is active, in which case the program must use the buffer to supply telephone numbers to the SCA Module.


Can the SINGER SYSTEM TEN 4310 terminal transmit or process an SOH character?

The terminal cannot send an SOH character. If it receives an SOH, it treats it as an STX. Therefore, user application programs should not request that data blocks be preceded by SOH.


How does the SINGER SYSTEM TEN 4310 indicate end of file when reading from tape?

When the terminal detects end of file on magnetic tape, it transmits a null data block (zero data characters) terminated with an ETX instead of the normal ETB. The terminal then sends an EOT, causing the SCA Module to post a W in the Inhibit Switch.


How does the user application program detect a null data block from the SINGER SYSTEM TEN 4310?

The user application program detects a null data block by identifying a value of zero in the Data Length field of the Receive Buffer Prefix. The program should mark the buffer available and ignore the block content.


What procedure must be followed to end transmission to the SINGER SYSTEM TEN 4310 terminal?

The user application program must transmit an ETX before sending an EOT. The ETX can be sent with the final regular data block or in a trailing null data block by placing an X in the Write Flag of the Transmit Buffer Prefix before posting the buffer ready. Once transmitted, the program requests an EOT in the Write Flag.


What occurs if an EOT is sent to the SINGER SYSTEM TEN 4310 without sending an ETX first?

Failing to send an ETX before sending an EOT causes the SINGER SYSTEM TEN 4310 terminal to signal an error condition instead of illuminating its End of File (EOF) indicator lamp.


How can a SINGER SYSTEM TEN 4310 user application program interrupt tape reading to print data?

To interrupt tape reading and transmit data to the printer, the program places a code 3 into the Read Flag of the Communications Control Block (CCB). This causes a Transmission Interrupt (TI) to be sent to the terminal, prompting the terminal to halt tape transmission and return an EOT.


Can the SINGER SYSTEM TEN 4310 terminal send a Transmission Interrupt (TI)?

No, the terminal cannot initiate or send a Transmission Interrupt.


What happens on the SINGER SYSTEM TEN 4310 after printer transmission finishes following an interrupt?

Once the application program completes transmission to the printer and requests an EOT in the Write Flag, the SCA Module transmits the EOT, and the terminal resumes transmission of its tape file.


How is output normally routed to devices on the SINGER SYSTEM TEN 4310 terminal?

Data routing is normally controlled by the PRINT/DUAL/WRITE TAPE switch located on the terminal:

PRINT: Directs data exclusively to the line printer.

WRITE TAPE: Directs data exclusively to the magnetic tape drive.

DUAL: Directs data simultaneously to both the line printer and tape drive.


How can the SINGER SYSTEM TEN 4310 user application program override the physical routing switch?

The program can override the PRINT or WRITE TAPE switch setting by placing code 1, 2, or 3 into the Write Flag of the Transmit Buffer for the first data block of the transmission.


What are the Write Flag device selection codes for the SINGER SYSTEM TEN 4310?

The remote device selection codes posted in the Write Flag are defined as follows:

Code Meaning
1 or 3 Route data to the line printer, even if the switch is set to WRITE TAPE.
2 Route data to the tape drive, even if the switch is set to PRINT.

Can the SINGER SYSTEM TEN 4310 user application program select both devices through software?

No, software selection cannot select both devices simultaneously. However, if the hardware switch on the terminal is physically set to DUAL, data will be sent to both devices regardless of program selection codes.


How long does a remote device selection stay in effect on the SINGER SYSTEM TEN 4310?

Once selected, data continues to route to that device until an EOT line control sequence is transmitted to the terminal.


What occurs if a selected remote device is not ready on the SINGER SYSTEM TEN 4310?

If the chosen device is not ready, the terminal returns an EOT response. The SINGER SYSTEM TEN 4310 Write Routine then posts a Q in the Inhibit Switch of the CCB and returns control to the Handshaking Routine.


Under what conditions will an unready device error occur on the SINGER SYSTEM TEN 4310?

This occurs under two main conditions:

1. An attempt is made to select the tape drive when it is not ready or when the terminal is set to DATA SEND mode.

2. An attempt is made to select the line printer when it is not in an ON-LINE condition.


How is vertical forms positioning controlled on the SINGER SYSTEM TEN 4310 line printer?

Vertical forms positioning is controlled by inserting control sequences (composed of a control flag character followed by control characters) directly into data blocks sent to the terminal.


How are forms control sequences executed when written to magnetic tape on the SINGER SYSTEM TEN 4310?

When transmitting to the tape drive, control sequences are recorded directly on the magnetic tape as received. The control actions are not executed until off-line printing from the tape takes place.


What flag character designates a control sequence on the SINGER SYSTEM TEN 4310?

Every control sequence begins with a reverse slash (\). Because the reverse slash always indicates a control sequence, it cannot be used as a printable data character in printable blocks.


When does the SINGER SYSTEM TEN 4310 line printer advance forms automatically?

The line printer automatically advances forms by one line at the end of each data block, and after printing 132 consecutive data characters without control sequences. If an “after printing” sequence is embedded in the line, that control function executes instead of the single-line feed.


What are the valid device control sequences for the SINGER SYSTEM TEN 4310?

The valid forms control sequences, representations, and actions are listed below:

Line Control Sequence Keyboard/Keypunch Equivalent USASCII Equivalent Extended Character Set Equivalent Action
\N 0-8-2, N LF J New Line: space one line immediately.
\K 0-8-2, K FF L Form Feed: skip to top of next page immediately.
\^A 0-8-2, A ESC A [A Skip to top of form: after printing.
\^Q 0-8-2, Q ESC Q [Q Single Space: after printing.
\^R 0-8-2, R ESC R [R Double Space: after printing.
\^S 0-8-2, S ESC S [S Triple Space: after printing.

What is the keypunch equivalent of the reverse slash on the SINGER SYSTEM TEN 4310?

The reverse slash is represented on keypunch equipment by the 0-8-2 multi-punch code, which is equivalent to multi-punch 11-7-8.


How does the Extended Character Set feature affect received control sequences on the SINGER SYSTEM TEN 4310?

When the Extended Character Set feature is enabled on the terminal, control sequences received by the SINGER SYSTEM TEN 4310 are translated into single characters. For example, a 200-character block beginning with \N is converted into a 199-character block beginning with J upon entering memory.


Why is it recommended to disable the Extended Character Set feature on the SINGER SYSTEM TEN 4310 when receiving data?

Disabling the feature prevents multi-character sequences from being translated into single-character equivalents, which facilitates easier identification and processing of control sequences by the application program.


Does the Extended Character Set feature affect transmissions sent from the SINGER SYSTEM TEN 4310 to the terminal?

No, the Extended Character Set feature has no effect when transmitting data from the SINGER SYSTEM TEN 4310 to the terminal.


How do control sequences affect the maximum printable character count in a SINGER SYSTEM TEN 4310 data block?

Control sequences occupy positions within the terminal buffer even though they do not print. Consequently, every control character included in a data block reduces the remaining space available for actual printable data characters within that 200-character limit.


How can double spacing be achieved between data blocks on the SINGER SYSTEM TEN 4310 line printer?

Double spacing between data blocks can be accomplished in two ways:

1. Include an immediate single space sequence (\N) at the start of the next block; combined with the automatic end-of-block single space, this yields effective double spacing.

2. Include an “after printing” double space sequence (\^R) in the block, which overrides the default single-space end-of-block action.


What sequence causes the SINGER SYSTEM TEN 4310 printer to perform an immediate triple space?

Sending the sequence \N\N\N causes the line printer to execute three consecutive line spaces immediately.


What sequence causes the SINGER SYSTEM TEN 4310 printer to skip to the top of the next form after printing?

The sequence \^A commands the printer to skip to the top of the next form following printing, replacing the automatic single-line feed.


What sequence commands the SINGER SYSTEM TEN 4310 printer to perform an immediate form feed?

The sequence \K causes the line printer to perform an immediate form feed, skipping straight to the top of the next page.


What assumptions are made at the beginning of the first printed data block on the SINGER SYSTEM TEN 4310?

When no forms control sequence is placed at the start of the first data block, the line printer assumes the continuous form paper has already been manually aligned at the top of form.


Where are data blocks placed within the SINGER SYSTEM TEN 4310 Transmit Buffer?

Data blocks containing text and embedded forms control sequences are loaded into positions 20 through 219 of the Transmit Buffer before being sent to the terminal.


CLICK HERE TO DOWNLOAD SINGER SYSTEM TEN 4310 (01) PDF DOCUMENT