What is included with the SIMA SSW-L4 EX?

1 – SSW Speaker Selector

1 – This instruction manual


What are the important safety precautions for using the SIMA SSW-L4 EX?

When using this product, basic safety precautions should always be followed to reduce the risk of fire and electric shock, including the following:

• Read and understand all instructions.

• Follow all warnings and instructions marked on this product.

• Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning.

• To prevent fire or shock hazard, do not expose this product to rain or moisture. Do not use near a bath tub, wash bowl, sink, or laundry tub; do not use in a wet basement or in a swimming pool.

• To avoid electrical shock, do not open the case of this product.

• The unit should be situated away from heat sources such as radiators, stoves, etc.


What are the features of the SIMA SSW-L4 EX?

The Sima speaker selectors have the following features:

• Ability to add up to 4 speaker pairs to your amplifier.

• Left and right “commons” are isolated to work with all types of amplifiers.

• Protection for amplifier.

• Small size to fit with any system.

• No power required for operation.

• Easy installation.

• Can handle up to 100 watts amplifier power.


What do the front panel controls on the SIMA SSW-L4 EX do?

1. Speakers on/off – Press button in to turn on all speaker pairs. Press again (button out) to turn off.

2. Amplifier selector – Press button in to select amp A. Press again (button out) to select amp B.

3. Volume control – An 11-step volume control for each speaker pair.


What are some installation tips for the SIMA SSW-L4 EX?

• It is recommended to use 18 or 16 AWG gauge stranded wire. For runs longer than 50′, 14 gauge is recommended.

• You can mix 4, 6, 8 and 16 ohm speakers.

• Since speakers have different efficiencies, more efficient speakers will sound louder than less efficient speakers. Either select your speakers to have the same efficiencies (a typical measurement is 90 db/watt) or add a speaker volume control between the SIMA SSW-L4 EX and the speaker in the room where the speaker is located.

• Wire according to state and local laws. Most places require that you use special in-wall speaker wire with a specific “CL” fire rating. Consult your dealer about obtaining such wire.

• Keep the speaker wiring from running close to AC power wiring for safety and to avoid any noise pick up.


How do I install and wire the SIMA SSW-L4 EX?

Make sure your receiver or power amplifier is turned off before doing any wiring.

• To make a connection, using a wire stripper, strip 3/8″ of insulation from the end of the wire. To avoid short circuits and possible amplifier damage, do not strip too much insulation from the wire.

• Tightly twist the end of the wire so that there are no frayed wires.

• For wiring convenience, connectors unplug from the connector block. Verify that there are no wire frays.

• Insert wire and tighten the terminal screw using a small screwdriver. Connect the wires from the speaker output from your receiver or amplifier to the SIMA SSW-L4 EX terminals marked AMPLIFIER. Pay attention and connect the “+” output from the right front output on the amplifier to the right “+” input on the SIMA SSW-L4 EX and connect the “-” output from your amplifier to the “-” input on the SIMA SSW-L4 EX. Likewise, connect the left channel wires to the left input of the SIMA SSW-L4 EX.

• Next, connect the wires from each of the speakers to the corresponding connection on the SIMA SSW-L4 EX.

• If you are using a second amplifier, connect it to the AMP B terminal.

• Plug connectors back into the unit. Warning: Be sure connectors are plugged in correctly – do not shift over one pin.


How do I perform the initial connection and test for the SIMA SSW-L4 EX?

It is recommended that you select only one speaker pair in the same room you are in for initial turn on. Select this speaker pair and turn on your receiver/amplifier. Make sure sound is coming from both speakers. Before you turn on additional speakers, read the information below.


How do the level controls on the SIMA SSW-L4 EX work?

Turning the level control fully counter-clockwise to the OFF position will turn that speaker pair off. Turning the level control clockwise will increase the volume in approximately 3 db steps.

Note: Refer to your amplifier or receiver’s user manual or on the rear panel of the amplifier to determine the minimal speaker impedance that your amplifier can handle.


What should I do if there is no sound from my SIMA SSW-L4 EX?

• Make sure correct speaker is selected.

• Make sure correct amplifier is selected.

• Make sure no wires are touching each other or the case of the amplifier or SIMA SSW-L4 EX selector.

• Make sure the connectors are plugged in correctly.


What should I do if my SIMA SSW-L4 EX gets hot?

• Reduce volume level of amplifiers.

• Turn unused speakers off.


What are the technical specifications for the SIMA SSW-L4 EX?

Input

100 watt per channel max

Outputs

4 Speaker pairs

4 to 16 ohm impedance

Protection Circuit

Amplifier Protection: Auto transformer

Wire gauge

14 to 22 gauge

Size: 17″ wide, 7.5″ deep, 3.25″ high

Weight: Approx. 7.5 lbs

Supplied accessories

User Manual (this document)

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD SIMA SSW-L4 EX (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.