Free English SHARP AF-R55CX (01) PDF Document. Free English SHARP AF-R55CX (01) PDF User Guide. Free English SHARP AF-R55CX (01) PDF User Manual. Free English SHARP AF-R55CX (01) PDF Owner Guide. Free English SHARP AF-R55CX (01) PDF Owner Manual. Free English SHARP AF-R55CX (01) PDF Reference Guide. Free English SHARP AF-R55CX (01) PDF Instruction Guide. Free English SHARP AF-R55CX (01) PDF Reference Manual. Free English SHARP AF-R55CX (01) PDF Instruction Manual. Free English SHARP AF-R55CX (01) PDF Operating Instructions.
CLICK HERE TO DOWNLOAD SHARP AF-R55CX (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What are the window requirements for installing the SHARP AF-R55CX air conditioner?
The mounting kit for the SHARP AF-R55CX is designed for wooden sill double or single hung sash-type windows. The window opening requirements are as follows:
Minimum opening (Without mounting kit): 17 23/32″ (450mm)
Mounting kit fully closed: 21 21/32″ (550mm)
Mounting kit fully opened: 33 7/16″ (850mm)
Additionally, the window opening from the stool to the lower sash bottom must be 14 27/32″ (377mm) or more.
What are the location requirements for installing the SHARP AF-R55CX?
To ensure proper installation and operation of your SHARP AF-R55CX, follow these location guidelines:
• The air conditioner should be installed on a firm foundation to minimize noise and vibration. For safe installation, repairs, replacement, and secure positioning, make sure the foundation is solid and level.
• The room air conditioner must be installed in an area within reach of a properly rated grounded outlet.
• Use of extension cords of any kind is not recommended.
• Never place any obstacles around the air inlet.
What accessories and tools are included or needed for installing the SHARP AF-R55CX?
The following accessories are provided for the installation of your SHARP AF-R55CX:
| No. | Accessories | Q’ty |
|---|---|---|
| 1 | Right closure assembly | 1 |
| 2 | Left closure assembly | 1 |
| 3 | Window sash foam seal | 1 |
| 4 | Window sash foam seal (adhesive type) | 1 |
| 5 | Bottom gasket | 1 |
| 6 | Screws (L=1″, 25.4mm) | 7 |
| 7 | Screws (L= 13/32″, 10mm) | 6 |
| 8 | Base pan angle | 2 |
| 9 | Remote control | 1 |
| 10 | Battery | 2 |
| 11 | Remote control hook | 1 |
Suggested Tools:
1. Screw driver (medium size Phillips)
2. Tape measure or ruler
3. Knife or scissors
How do I install the SHARP AF-R55CX air conditioner?
WARNING: Make sure the unit is turned off and unplugged before working.
Step 1. Cut the window sash foam seal (adhesive type) to the proper length and attach it to the underside of the window sash.
Step 2. Insert the right closure assembly and the left closure assembly into the top angle and the bottom channels. Secure the right and left closure to the cabinet with six of the provided screws (L= 13/32″, 10mm).
Step 3. Open the window sash and place the air conditioner on the sill. Balance the unit on the sill and close the window sash securely behind the top angle. WARNING: At this step, make sure the unit is inclined approximately 1 cm (3/8″) to the back. If the unit is not properly inclined, the water collected in the bottom tray during operation will not drain properly and may flow into the room where the air conditioner is installed.
Step 4. Insert the bottom gasket into the space between the window sill and the bottom of the unit to seal outside air. If there is space between the bottom channel and the sill, fill the gap with a thin board or other hard filler.
Step 5. Insert the closure assemblies on both sides into the rails of the jamb.
Step 6. Loosen screws on both sides of the cabinet, then hang the base pan angle on and secure the screws again.
Step 7. Secure the base pan angle to the sill by using the hole of the front side on the angle with one screw (L=1″, 25.4mm).
Step 8. Secure the top angle of the unit and the top of the closure assemblies to the sash with three of the provided screws (L=1″, 25.4mm). And secure the bottom of the closure assemblies to the sill with two of the provided screws (L=1″, 25.4mm).
Step 9. Cut the window sash foam seal to the proper length and seal the opening between the top of the inside window sash and the outside window sash.
What are the important precautions for using the SHARP AF-R55CX?
IMPORTANT: Points to keep in mind when using your SHARP AF-R55CX air conditioner.
• Install the air conditioner by following the installation instructions.
• Make sure the unit is the correct capacity for the area you want to cool.
• Do not modify any part of this product.
• Do not insert objects into any part of the unit.
• Push the AC power plug securely into the receptacle and make sure it is not loose.
• Use a power circuit with a proper voltage rating. Use a three-pronged grounded electrical outlet rated 125V, 60Hz, 15 amp or more, AC only. Use of an improper voltage rating power circuit can result in damage to the unit and possibly fire.
• Always use a fuse with the proper amp rating. Do not, under any circumstances, use wire, pins or other objects in place of the proper fuse.
• Use of extension cords of any kind is not recommended. If you still elect to use an extension cord, it is absolutely necessary that it be a UL Listed 3-wire grounding type appliance extension cord rated 125 Volts, 15 amp or more.
• Ventilate the room periodically during use, especially if using gas appliances.
What are the grounding instructions for the SHARP AF-R55CX?
WARNING: Improper use of the grounding plug can result in the risk of electric shock. This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
WARNING: Do not under any circumstances cut or remove the round grounding prong from this plug. If it is necessary to use an extension cord, use only a UL Listed 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the appliance. The marked rating of the extension cord should be AC 125 Volt, 15 Amp or more.
Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. If a grounding adapter is used, make sure the receptacle box is fully grounded.
What should I know about the operation of my SHARP AF-R55CX?
• Allow 3 minutes for the compressor to restart cooling. If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor off for three minutes for protection.
• If a power failure occurs during use, allow 3 minutes before restarting the unit. After power is reinstated, restart the air conditioner. If the power was off for less than three minutes, be sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within three minutes, a protective device in the unit may cause the compressor to shut off. This protective device will prevent cooling for about 5 minutes. Memories of previous settings will be canceled and the unit will return to each initial setting.
• Dehumidifying function. The air conditioner removes moisture from the air in your room.
• Cooling operation under low temperatures: Is your unit freezing up? The unit operates on inside and outside temperatures. Freezing can occur when the temperature is set close to 64°F and when there are low outside temperatures, especially during the night hours. At these conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher temperature will prevent it from freezing.
How can I use my SHARP AF-R55CX more efficiently?
• Setting the proper temperature. For optimum energy efficiency, keep the difference between the inside and outside temperature within 10°F (5°C). Do not keep the temperature setting any lower than is necessary for you to feel comfortable. Generally, 78°F to 80°F (26°C to 27°C) is a comfortable summer indoor temperature. When you turn the unit on, do not set the temperature higher than the room temperature at start up as this will not allow the compressor to cycle and maintain a comfortable room temperature.
• Avoid direct sunlight. Close blinds, drapes or shades to keep out direct sunlight during cooling operation.
• Keep the filter clean. Keeping the filter clean greatly aids efficient operation. A dirty filter blocks the flow of air, making your air conditioner work harder and less efficiently.
• Turn off unnecessary light. Your air conditioner must remove the heat produced by your lights or other heat-producing appliances. Turn off lights or appliances that are not in use.
• Install your air conditioner in a shady location. Direct sunlight on a window air conditioner increases its workload and will increase its operating cost.
• Don’t let cool air escape. Close windows and outside doors. Do not keep doors open and let hot air rush in. Improperly installed air conditioners and improperly weatherstripped doors and windows will let hot air in and the cool air out.
• Turn off air conditioner when no one is home. Use only when necessary. The fewer hours a room air conditioner is used, the lower the operating cost.
What are the main parts of the SHARP AF-R55CX and its control panel?
UNIT
1. Front Cabinet
2. Air Inlet (Indoor Side)
3. Horizontal Louvers
4. Vertical Louvers
5. Air Outlet (Indoor Side)
6. Control Panel
7. Rear Cabinet
8. Air Inlet (Outdoor side)
9. Filter (Pull the filter handle to the right to remove.)
10. Filter Handle
11. Power Cord
CONTROL PANEL (AF-R55CX)
1. Receiver window for remote control signal
2. Display
3. SELECTOR indicator
4. SELECTOR pad
5. TEMPERATURE setting pad (v —-Lower temp. ^ —-Raise temp.)
6. TIMER ON/OFF pad
7. TIMER indicator
8. ENERGY SAVER pad
9. ENERGY SAVER indicator
10. POWER ON/OFF pad
11. POWER indicator
How do I start and stop the cooling operation on the SHARP AF-R55CX?
To start cooling:
1. Touch the POWER ON/OFF pad.
• The unit is preset at 74°F and HIGH COOL. This will show in the display when the power is first turned on.
• The POWER indicator and SELECTOR indicator (COOL) will light.
To stop cooling:
2. To turn off the unit, touch the POWER ON/OFF pad again.
• The POWER indicator and SELECTOR indicator will go off.
NOTE: In cases of power outages or when the unit is disconnected, the unit will return to the preset conditions of 74°F and HIGH COOL when power is restored. The unit will not automatically turn back on. You must touch POWER ON/OFF to resume operation.
How do I change the temperature setting on the SHARP AF-R55CX?
During cooling operation, touch the TEMPERATURE setting pad to adjust the temperature setting.
• v – Lower temp.
• ^ – Raise temp.
The temperature can be set within the range of 64°F to 86°F. The display will change as you touch the pad.
NOTE: The latest temperature setting will be memorized and will appear on the display the next time the unit is turned on.
How do I change the fan speed and operation mode on my SHARP AF-R55CX?
During operation, touch the SELECTOR pad to select the operation mode and fan speed. The SELECTOR indicator and display will light in the following order as you touch the pad:
HIGH COOL → MED COOL → LOW COOL → LOW FAN → MED FAN → HIGH FAN
The following table shows the display for each mode:
| MODE | SELECTOR | DISPLAY | |
|---|---|---|---|
| HIGH COOL | COOL | Three fan icons | Cooling operation with high fan speed. |
| MED COOL | COOL | Two fan icons | Cooling operation with medium fan speed. |
| LOW COOL | COOL | One fan icon | Cooling operation with low fan speed. |
| HIGH FAN | FAN | Three fan icons | Fan only operation with high fan speed. |
| MED FAN | FAN | Two fan icons | Fan only operation with medium fan speed. |
| LOW FAN | FAN | One fan icon | Fan only operation with low fan speed. |
NOTES:
• The latest operation mode will be memorized and the selector indicator and display will light when the unit is turned on.
• In fan only operation, the temperature display will go off.
• When the SELECTOR is changed to fan only operation from cooling operation, it will take 5 seconds for the compressor to stop.
How does the Energy Saver function work on the SHARP AF-R55CX?
During normal operation, the thermostat automatically controls cooling and the fan runs continuously. When ENERGY SAVER is selected, the thermostat automatically controls cooling and the fan automatically stops when the compressor is not operating. The fan will stop 30 seconds after the compressor stops. Even after the fan stops, the fan will rotate for 2 minutes, every maximum 20 minutes, to detect room temperature.
To use Energy Saver during cooling operation:
1. Touch the ENERGY SAVER pad. The ENERGY SAVER indicator will light.
2. To cancel, touch the ENERGY SAVER pad again. The ENERGY SAVER indicator will go off.
NOTE: ENERGY SAVER cannot be set during fan only (HIGH FAN, MED FAN, LOW FAN) operation.
How do I adjust the air flow direction on the SHARP AF-R55CX?
You can adjust the air flow for uniform and efficient cooling of the room.
• Horizontal louvers: Used to adjust the UP / DOWN direction of air flow.
• Vertical louvers: Used to adjust the LEFT / RIGHT direction of air flow by moving the lever.
How do I set the ON timer on my SHARP AF-R55CX?
The built-in ON timer can be programmed to start the unit up to 12 hours in advance.
When the unit is not operating:
1. Touch the TIMER ON/OFF pad to set the delayed start time. The time setting will change as you touch the pad. You can set the timer in increments of 30 minutes (0.5 hours) up to 9.5 hours, and in 1 hour increments from 10 to 12 hours.
• The timer will be set 5 seconds after the TIMER ON/OFF pad is touched for the last time.
• The SELECTOR indicator and TIMER indicator will light.
• The time display will count down the remaining time.
• The unit will start when the set time expires and the temperature setting will be displayed.
To cancel the timer setting: Touch the TIMER ON/OFF pad again after the timer is set, or press the TIMER ON/OFF pad until CL(cancel) appears on the display.
Notes for Timer Setting:
• After setting the TIMER, you can change the temperature and fan speed settings. When the temperature is set in the timer mode, the temperature will show in the display for 5 seconds and then return to the time display.
• The last setting used will be memorized for the next time you use the TIMER function.
• If a power failure occurs, the TIMER memory will be canceled and will not resume. The unit will not automatically start.
How do I set the OFF timer on my SHARP AF-R55CX?
The built-in OFF timer can be programmed to shut the unit off up to 12 hours in advance.
When the unit is operating:
1. Touch the TIMER ON/OFF pad to set the delayed stop time. The time setting will change as you touch the pad. You can set the timer in increments of 30 minutes (0.5 hours) up to 9.5 hours, and in 1 hour increments from 10 to 12 hours.
• The timer will be set 5 seconds after the TIMER ON/OFF pad is touched for the last time.
• The TIMER indicator will light.
• The time display will count down the remaining time.
• The unit will stop when the set time expires. All indicators and displays will go out.
To cancel the timer setting: Touch the TIMER ON/OFF pad again after the timer is set, or press the TIMER ON/OFF pad until CL(cancel) appears on the display.
How do I install batteries and use the remote control for the SHARP AF-R55CX?
Installing Batteries (Use two size-AAA R03 batteries)
1. Remove the battery compartment cover.
2. Insert the batteries in the compartment, making sure the (+) and (-) polarities are properly aligned.
3. Replace the cover.
Notes on Batteries:
• Battery life is approximately one year with normal use.
• Always use two new batteries of the same type when replacing.
• If the remote does not operate normally after replacing batteries, take them out and replace them again after 30 seconds.
• If you will not be using the unit for a long time, remove the batteries from the remote control.
Attaching the Remote Control Hook
• Remove the backing from the remote control hook.
• Attach the hook onto the left side of the unit’s front cabinet.
• To prevent loss, hook the remote control on the front cabinet when not in use.
How to Use the Remote Control
Point the remote control towards the unit’s receiver window and press the desired button. A beep will sound when the unit receives the signal.
• Make sure no objects, such as curtains, block the receiver window.
• The remote control operates from up to 20 feet (6 meters) away.
• A beep will also sound when each pad on the control panel is touched.
CAUTION:
• Do not expose the receiver window to direct sunlight, as this can adversely affect its operation. In such cases, close the curtains to block the sunlight.
• Use of a fluorescent lamp in the same room may interfere with signal transmission.
• The unit may be affected by signals from other remote controls (TV, VCR, etc.) in the same room.
• Do not leave the remote control exposed to direct sunlight or near a heater. Protect it from moisture and shock.
What are the functions of the buttons on the SHARP AF-R55CX remote control?
• POWER ON/OFF button: Push to start or stop the operation.
• TEMPERATURE setting button (TEMP ▲ / TEMP ▼):
– TEMP ▲: Raise temp. setting 1°F at a time.
– TEMP ▼: Lower temp. setting 1°F at a time.
• SELECTOR button: Push to change fan speed and operation mode. The selections are: HIGH COOL, MED COOL, LOW COOL, HIGH FAN, MED FAN, LOW FAN.
• SET TIMER/OFF button: Push to set a delayed “OFF” timer during operation.
– The time setting will change as you push the button, from 0.5h up to 12h, or CL(cancel).
– The last OFF time setting is memorized and will appear on the display when the button is pushed.
– The timer is set 5 seconds after the button is pushed for the last time.– To cancel, push the SET TIMER/OFF button until CL (cancel) appears on the display. A double beep will sound when the timer is canceled.
– The “ON” TIMER cannot be set with the remote control. It can only be activated by the TIMER ON/OFF pad on the unit’s control panel.
To change temperature setting when ON/OFF timer is in use:
1. Push a TEMPERATURE setting button. The current set temperature will be recalled on the unit’s display.
2. Use the TEMPERATURE setting buttons to set the new temperature. The new set temperature will show on the display for 5 seconds and return to the time display.
How do I clean the filter on my SHARP AF-R55CX?
If the filter is clogged with dust, air flow will be reduced, resulting in poor cooling performance. The filter should be cleaned every 10 days. Clean the filter before starting the unit at the beginning of each cooling season or after a long period of inactivity.
1. REMOVE THE FILTER
Gently pull the filter handle to the right and slide the filter out from the unit.
2. CLEAN THE FILTER
To remove dust from the filter, use a vacuum cleaner or wash it in clean water. If the filter is very dirty, wash it with detergent and rinse carefully with clean water. Dry the filter with a soft cloth. Do not expose the filter to heat or dry it in direct sunlight.
3. RE-INSTALL THE FILTER
Align the filter behind the front panel. Grasp the filter handle and gently push the filter back into place. Never operate the unit without installing the filter, as it may result in serious damage.
How do I clean the front panel and cabinet of my SHARP AF-R55CX?
To clean the front panel and cabinet, wipe with a soft, dry cloth or with a cloth moistened with a mild soap. Rinse carefully by wiping with a damp cloth and dry completely.
Avoid splashing the unit with water, as excess water can damage electrical insulation and result in danger.
Never use harsh chemicals or abrasive cleaners on any part of the unit. To avoid damage, do not use hot water (120°F / 50°C or more) when cleaning.
Does the compressor or fan motor on the SHARP AF-R55CX need oiling?
No, oiling of the compressor and fan motor is unnecessary. The compressor is permanently lubricated and is hermetically sealed. The fan motor is lifetime sealed and does not require oiling.
What should I check if my SHARP AF-R55CX does not operate at all?
If your SHARP AF-R55CX does not operate, please check the following:
• Is the unit plugged in or is the plug loose?
• Is the fuse blown or the circuit breaker tripped?
• Did you restart the unit within 3 minutes after a power failure? If the power was off for less than 3 minutes, and you restarted the air conditioner within 3 minutes, a protective device may cause the compressor to shut off, preventing cooling for about 5 minutes.
What should I do if my SHARP AF-R55CX does not cool properly?
If your SHARP AF-R55CX is not cooling properly, check these points:
• Is the SELECTOR set to fan only (HIGH FAN, MED FAN, LOW FAN) mode? Cooling will not take place in the fan only mode. Change the SELECTOR setting.
• Is the filter clogged with dust? A dirty filter can cause the cooling coils to freeze. If this happens, clean the filter and replace. Run the air conditioner on the MED FAN setting until all ice dissipates.
• Is the temperature set properly? If your room is too warm, adjust the temperature setting lower. If your room is too cool, adjust the temperature setting higher.
• Is the window exposed to direct sunlight? Close curtains or blinds to minimize solar energy heating the room.
• Are the windows or doors open? Close all windows and doors for maximum cooling.
Why is the timer on my SHARP AF-R55CX not working properly after a power failure?
If a power failure occurs while the ON or OFF TIMER is set, the TIMER setting will be cancelled and will not resume even after the power is reinstated. This is the normal operation for this unit.
Is it normal to see water in the bottom tray of my SHARP AF-R55CX?
Yes, this is normal. Water will collect in the bottom tray of the unit. Water condenses on the evaporator coil at the front of the unit and is channeled to the rear where it is picked up by the condenser fan. The water is blown onto the condenser coil fins and this creates a “splashing” noise which is normal. If excess water builds up in this tray it will drain outside through a grooved channel in the tray.
What are the normal operating sounds for the SHARP AF-R55CX?
• The operating sound may seem rather loud for 2 to 3 minutes when the unit is first turned on. This is the sound of the compressor’s start-up and is normal.
• A soft, swishing noise can be heard immediately after the unit is turned on or off, and also during operation. This is the sound of the refrigerant flowing inside the unit.
What should I do if my SHARP AF-R55CX fails to receive the remote control signal?
If the unit is not responding to the remote control, please check the following:
• Check the remote control batteries. Replace if necessary.
• Try to send the signal again with the remote control pointed directly at the unit’s receiver window.
• Check whether the remote control batteries are installed with the polarities properly aligned.
CLICK HERE TO DOWNLOAD SHARP AF-R55CX (01) PDF DOCUMENT