What are the specifications for the SEARS KENMORE ECONOMIZER 5 153.333100?

The SEARS KENMORE ECONOMIZER 5 153.333100 has a tank capacity of 40 gallons, utilizes natural gas, has a 32,000 BTU rate, a recovery rate of 33.0 gallons per hour at a 90 degree Fahrenheit rise, requires a 3 inch minimum vent pipe, measures 18 inches in diameter, and has a height to the jacket top of 56 and 1/2 inches.


What should I do if I smell gas near my SEARS KENMORE ECONOMIZER 5 153.333100?

If you smell gas, do not try to light any appliance. Do not touch any electrical switch or use any phone in your building. Immediately call your gas supplier from a neighbor’s phone and follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.


What precautions should be taken regarding hot water scalds with the SEARS KENMORE ECONOMIZER 5 153.333100?

Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure upon contact. People who are more likely to be permanently injured by hot water include the elderly, children, the infirm, or the physically or mentally handicapped. To prevent injury, use the lowest possible temperature setting that satisfies your hot water needs. Additionally, a tempering device such as a mixing valve should be used at the hot water taps used by these people or at the SEARS KENMORE ECONOMIZER 5 153.333100.


How do I correctly remove my old water heater?

Step 1. Turn off the gas supply to the water heater.

Step 2. Turn off the water supply to the water heater at the water shut off valve or water meter.

Step 3. Check again to make sure the gas supply is off to the water heater, then disconnect the gas supply connection from the gas control valve.

Step 4. Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors. Open the water heater drain valve and open a nearby hot water faucet to relieve pressure and speed draining.

Step 5. Disconnect the vent pipe from the draft hood where they connect to the water heater.

Step 6. Disconnect the temperature pressure relief valve drain line. Once the water heater is drained, disconnect the hose from the drain valve, close the drain valve, and the unit is ready to be removed.


What is the procedure for lighting the pilot on the SEARS KENMORE ECONOMIZER 5 153.333100?

Step 1. Set the thermostat to the lowest setting by turning the water temperature dial clockwise to its lowest setting.

Step 2. Turn the gas control knob clockwise to the OFF position.

Step 3. Wait five minutes to clear out any gas.

Step 4. Remove or open the inner door located below the gas control unit.

Step 5. Find the pilot by following the metal tube from the gas control; the pilot is located on the right hand side of the burner.

Step 6. If you do not smell gas, turn the knob on the gas control counter clockwise to the PILOT position.

Step 7. Push in the control knob all the way and hold down. Immediately light the pilot with a match. Continue to hold the control knob in for about one minute after the pilot is lit. Release the knob and it should pop back up. The pilot should remain lit.

Step 8. Replace the inner door and replace the outer door if the door does not cover the gas control or temperature adjustment knob.

Step 9. At arm’s length away, turn the gas control knob counter clockwise to the full ON position.

Step 10. Set the thermostat to the desired setting.


How do I adjust the temperature on the SEARS KENMORE ECONOMIZER 5 153.333100?

Turn the water temperature dial clockwise to decrease the temperature, or counter clockwise to increase the temperature. The mark of HOT is indicative of approximately 120 degrees Fahrenheit. A is approximately 130 degrees Fahrenheit, B is approximately 140 degrees Fahrenheit, C is approximately 150 degrees Fahrenheit, and VERY HOT is approximately 160 degrees Fahrenheit.


What causes condensation on the SEARS KENMORE ECONOMIZER 5 153.333100 and is it a leak?

Condensation can occur when a new water heater is filled with cold water for the first time, when gas burns and produces water vapor, or when large amounts of hot water are used in a short time. Moisture from the products of combustion condenses on the cooler tank surfaces and forms drops of water. This is common at the time of startup after installation and when incoming water is cold. Do not assume the water heater is leaking until there has been enough time for the water in the tank to warm up.


How do I drain the SEARS KENMORE ECONOMIZER 5 153.333100 for maintenance?

Step 1. Turn the gas control knob to the OFF position.

Step 2. Close the cold water inlet valve to the water heater.

Step 3. Open a nearby hot water faucet and leave it open to allow for draining.

Step 4. Connect a hose to the drain valve and terminate to an adequate drain.

Step 5. Open the water heater drain valve to allow for tank draining.

Step 6. When finished, close the drain valve and follow the instructions in the manual to refill the water heater.


What should I do if my SEARS KENMORE ECONOMIZER 5 153.333100 has a soot build up?

Soot build up indicates a problem that requires correction before further use. Turn off the gas to the SEARS KENMORE ECONOMIZER 5 153.333100 and leave it off until repairs are made, because failure to correct the cause of the sooting can result in a fire causing death, serious bodily injury, or property damage.


What are the requirements for the sediment trap for the SEARS KENMORE ECONOMIZER 5 153.333100?

A sediment trap shall be installed as close to the inlet of the SEARS KENMORE ECONOMIZER 5 153.333100 as practical. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap.