Free English SEARS CRAFTSMAN 921.166370 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD SEARS CRAFTSMAN 921.166370 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What is the recommended circuit requirement for the SEARS CRAFTSMAN 921.166370?
The SEARS CRAFTSMAN 921.166370 should be operated on a dedicated 15 amp circuit. If the circuit does not have 15 free amps available, a larger circuit must be used. The circuit fuse type must be a time delay.
What are the extension cord requirements for the SEARS CRAFTSMAN 921.166370?
You must use a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle. All extension cords must be 12 gauge with a maximum length of 25 feet. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating.
What safety equipment should be worn when using the SEARS CRAFTSMAN 921.166370?
Always wear ANSI Z87.1 approved safety glasses with side shields when the SEARS CRAFTSMAN 921.166370 is in use. Additionally, when draining the tank, always use ear and eye protection.
What is the proper clearance for the SEARS CRAFTSMAN 921.166370 during operation?
The SEARS CRAFTSMAN 921.166370 should always have adequate space, specifically 12 inches on all sides of the unit, and be located in a clean, dry, and well-ventilated environment.
How should the SEARS CRAFTSMAN 921.166370 be positioned for use?
Operation of the SEARS CRAFTSMAN 921.166370 should always be in a position that is stable. Never use the unit on a rooftop or elevated position that could allow the unit to fall or be tipped over. Use additional air hose for elevated jobs.
How do I assemble the handle for the SEARS CRAFTSMAN 921.166370?
Attach the handle to the frame of the SEARS CRAFTSMAN 921.166370 with the saddle bolts from the outside of the handle and the knobs on the inside.
What type of oil is required for the SEARS CRAFTSMAN 921.166370?
The SEARS CRAFTSMAN 921.166370 requires SAE-30 non-detergent (API CG/CD heavy duty motor oil). Under extreme cold weather conditions of 32 degrees Fahrenheit or below, use SAE-10 weight oil.
What is the oil capacity for the SEARS CRAFTSMAN 921.166370?
The oil capacity for the SEARS CRAFTSMAN 921.166370 is 90 mL or 3 ounces. Fill until the oil reaches the top of the red dot in the sight glass.
What are the daily start-up procedures for the SEARS CRAFTSMAN 921.166370?
Step 1. Set the Auto-On/Off lever to the Off position.
Step 2. Inspect the SEARS CRAFTSMAN 921.166370, air hose, and any accessories/tools for damage or obstruction.
Step 3. Close the drain valve.
Step 4. Check the oil level of the pump.
Step 5. Connect the air hose to the quick connect socket.
Step 6. Plug the power cord into the proper receptacle.
Step 7. Turn the Auto-On/Off lever to the On-Auto position.
Step 8. Adjust the regulator to the desired PSI.
What are the daily shut-down procedures for the SEARS CRAFTSMAN 921.166370?
Step 1. Set the Auto-On/Off lever to the Off position.
Step 2. Unplug the power cord from the receptacle.
Step 3. Set the outlet pressure to zero on the regulator.
Step 4. Remove any air tools or accessories.
Step 5. Open the drain valve to allow air to bleed from the tank, then close it once the air has bled.
How do I detach the SEARS CRAFTSMAN 921.166370 from its dolly?
Step 1. Turn off and unplug the SEARS CRAFTSMAN 921.166370 from the power source.
Step 2. Turn the knob on the bottom of the dolly counter-clockwise until it releases (1 to 2 revolutions).
Step 3. While holding the dolly cart handle, lift up on the SEARS CRAFTSMAN 921.166370 handle to remove it.
How do I reattach the SEARS CRAFTSMAN 921.166370 to its dolly?
Step 1. Ensure the SEARS CRAFTSMAN 921.166370 is off and unplugged.
Step 2. Align the rubber isolators with the depressions in the dolly frame.
Step 3. Insert the knob bolt and rotate clockwise until tight. If it does not tighten, reposition and try again.
What is the maintenance schedule for the SEARS CRAFTSMAN 921.166370?
The following table outlines the maintenance schedule for the SEARS CRAFTSMAN 921.166370:
| Items to Check/Change | Frequency |
|---|---|
| Check Tank Safety Valve | Before each use or daily |
| Overall Unit Visual Check | Before each use or daily |
| Check Air Filter | Before each use or daily |
| Drain Tank | Before each use or daily |
| Check Power Cord for Damage | Before each use or daily |
| Change Oil | After first 50 hours, then every 100 hours |
| Check Oil Level | Before each use or daily |
How do I troubleshoot air leaks at the check valve or pressure relief valve on the SEARS CRAFTSMAN 921.166370?
A defective check valve results in a constant air leak at the pressure relief valve when there is pressure in the tank and the SEARS CRAFTSMAN 921.166370 is shut off. Drain the tank, then remove and clean or replace the check valve.
What should I do if the SEARS CRAFTSMAN 921.166370 has air leaks between the head and cylinder?
Check the torque on the head bolts of the SEARS CRAFTSMAN 921.166370. If the leak remains, contact a service technician.
How do I fix an air leak from the safety valve on the SEARS CRAFTSMAN 921.166370?
Operate the safety valve on the SEARS CRAFTSMAN 921.166370 manually by pulling on the ring. If the valve continues to leak when in the closed position, it should be replaced.
Why does the pressure reading on the SEARS CRAFTSMAN 921.166370 regulated gauge drop when an accessory is used?
If there is an excessive amount of pressure drop, replace the regulator. Note that you should adjust the regulated pressure under flow conditions (while the accessory is being used). It is normal for the gauge to show minimal pressure loss during initial use of the tool.
What if the SEARS CRAFTSMAN 921.166370 shows excessive tank pressure?
Move the Auto-On/Off lever on the SEARS CRAFTSMAN 921.166370 to the Off position. If the unit does not shut off, unplug it from the power source and contact a service technician.
What should I do if the motor of the SEARS CRAFTSMAN 921.166370 will not start?
Make sure the power cord is plugged in and the switch is on. Inspect the circuit box for the proper size fuse. If the fuse was tripped, reset it and restart the SEARS CRAFTSMAN 921.166370. If repeated tripping occurs, replace the check valve or contact a service technician.
How can I manage excessive moisture in the discharge air of the SEARS CRAFTSMAN 921.166370?
Remove the water in the tank by draining after each use. High humidity environments will cause excessive condensation. Utilize water filters on your air line. Note that water condensation is not caused by a malfunction of the SEARS CRAFTSMAN 921.166370.
What to do if there are air leaks from the tank body or welds on the SEARS CRAFTSMAN 921.166370?
Never drill into, weld, or otherwise modify the air tank of the SEARS CRAFTSMAN 921.166370 or it will weaken. The tank can rupture or explode. The tank cannot be repaired. Discontinue use of the unit.
What is the duty cycle for the SEARS CRAFTSMAN 921.166370?
The SEARS CRAFTSMAN 921.166370 has a 50% duty cycle. Do not run it more than 30 minutes in one hour, as doing so could damage the unit.
How do I store the SEARS CRAFTSMAN 921.166370?
Step 1. Turn the unit off and unplug the power cord.
Step 2. Remove all air hoses, accessories, and air tools.
Step 3. Perform the daily maintenance schedule.
Step 4. Open the drain valve to bleed all air from the tank.
Step 5. Close the drain valve.
Step 6. Store the SEARS CRAFTSMAN 921.166370 in a clean and dry location.
What is the purpose of the Tank Safety Valve on the SEARS CRAFTSMAN 921.166370?
The Tank Safety Valve on the SEARS CRAFTSMAN 921.166370 is used to allow excess tank pressure to escape into the atmosphere. This valve should only open when the tank pressure is above the maximum rated pressure.
How does the Pressure Switch on the SEARS CRAFTSMAN 921.166370 operate?
The pressure switch on the SEARS CRAFTSMAN 921.166370 controls the power to the motor and also the cut-in/cut-out pressure settings. This switch serves as the Auto-On/Off positions for the unit.
What is the function of the Pressure Relief Valve on the SEARS CRAFTSMAN 921.166370?
The pressure relief valve on the SEARS CRAFTSMAN 921.166370 is located on the side of the pressure switch and is designed to automatically release compressed air when the air compressor reaches cut-out pressure. The released air should only escape momentarily.
How do I adjust the pressure on the SEARS CRAFTSMAN 921.166370?
The air pressure coming from the tank of the SEARS CRAFTSMAN 921.166370 is controlled by the regulator. To increase the pressure, turn the knob clockwise; to decrease the pressure, turn the knob counter-clockwise.
How do I maintain the air intake filter for the SEARS CRAFTSMAN 921.166370?
The air intake filter provides clean air to the pump of the SEARS CRAFTSMAN 921.166370 and must always be kept free of debris. Check it on a daily basis or before each use.
Are there any special break-in procedures for the SEARS CRAFTSMAN 921.166370?
No break-in procedure is required for the SEARS CRAFTSMAN 921.166370. This product is factory tested to ensure proper operation and performance.
What is the maximum pressure for accessories used with the SEARS CRAFTSMAN 921.166370?
Inflation and cleaning accessories packaged with the SEARS CRAFTSMAN 921.166370 should only be operated at a maximum pressure of 90 PSI.
How is the SEARS CRAFTSMAN 921.166370 grounded?
The SEARS CRAFTSMAN 921.166370 is equipped with a cord having a grounding wire with an appropriate grounding plug. This must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
What should I do if the SEARS CRAFTSMAN 921.166370 plug does not fit the outlet?
Do not modify the plug provided with the SEARS CRAFTSMAN 921.166370. If it will not fit the outlet, have the proper outlet installed by a qualified electrician.
Is an adapter permitted for use with the SEARS CRAFTSMAN 921.166370?
An adapter should not be used with the SEARS CRAFTSMAN 921.166370.
What should I do if I experience difficulty assembling the SEARS CRAFTSMAN 921.166370?
If you are unsure of assembly instructions or experience difficulty in the assembly of the SEARS CRAFTSMAN 921.166370, please call your local service department for further instruction.
Can I use the SEARS CRAFTSMAN 921.166370 in the rain?
No, never utilize the SEARS CRAFTSMAN 921.166370 in the rain or wet conditions.
Can I operate the SEARS CRAFTSMAN 921.166370 near flammable materials?
Never operate the SEARS CRAFTSMAN 921.166370 near combustible materials, gasoline, or solvent vapors. If spraying flammable materials, locate the air compressor at least 20 feet away from the spray area.
Does the SEARS CRAFTSMAN 921.166370 provide breathable air?
No, the SEARS CRAFTSMAN 921.166370 does not provide breathable air for anyone or any auxiliary breathing device.
How often should I drain the SEARS CRAFTSMAN 921.166370 tank?
Always drain the SEARS CRAFTSMAN 921.166370 tank daily or after each use to prevent corrosion.
Can I modify the tank of the SEARS CRAFTSMAN 921.166370?
Never try to make any modifications to the tank of the SEARS CRAFTSMAN 921.166370. Never modify the factory settings which control the tank pressure or any other function.
What is the pump type of the SEARS CRAFTSMAN 921.166370?
The pump of the SEARS CRAFTSMAN 921.166370 is an oil-lube direct drive.
What is the motor horsepower of the SEARS CRAFTSMAN 921.166370?
The SEARS CRAFTSMAN 921.166370 features a 1.0 HP (Induction) motor.
What is the air tank capacity of the SEARS CRAFTSMAN 921.166370?
The air tank capacity of the SEARS CRAFTSMAN 921.166370 is 4 gallons.
What are the cut-in and cut-out pressures for the SEARS CRAFTSMAN 921.166370?
The SEARS CRAFTSMAN 921.166370 has a cut-in pressure of 95 PSI and a cut-out pressure of 125 PSI.
What is the SCFM rating of the SEARS CRAFTSMAN 921.166370 at 90 PSI?
The SEARS CRAFTSMAN 921.166370 is rated at 2.4 SCFM at 90 PSI.
What is the bore and stroke of the SEARS CRAFTSMAN 921.166370?
The SEARS CRAFTSMAN 921.166370 has a bore of 1.65 inches and a stroke of 1.26 inches.
What is the voltage requirement for the SEARS CRAFTSMAN 921.166370?
The SEARS CRAFTSMAN 921.166370 requires 120 VAC, single phase.
Can I use the SEARS CRAFTSMAN 921.166370 indoors?
Never operate the SEARS CRAFTSMAN 921.166370 indoors or in a confined area.
What is the purpose of the Tank Drain Valve on the SEARS CRAFTSMAN 921.166370?
The tank drain valve on the SEARS CRAFTSMAN 921.166370 is used to drain condensation from the air tank and is located at the bottom of the tank.
How do I release the air hose from the quick connect socket on the SEARS CRAFTSMAN 921.166370?
To release the air hose on the SEARS CRAFTSMAN 921.166370, push the collar back on the quick connect socket.
What does it mean if the air hose quick connect socket collar on the SEARS CRAFTSMAN 921.166370 snaps forward?
When you insert the quick connect plug into the socket on the SEARS CRAFTSMAN 921.166370, the collar snaps forward to lock the plug into place, providing an air tight seal.
Are there specific safety warnings for moving parts on the SEARS CRAFTSMAN 921.166370?
Yes. If the SEARS CRAFTSMAN 921.166370 is in operation, all guards and covers should be attached or installed correctly. If any guard or cover has been damaged, do not operate the equipment. The power cord should be free of any moving parts.
Is the SEARS CRAFTSMAN 921.166370 pump surface hot during operation?
Yes. Items such as the pump and outlet tube of the SEARS CRAFTSMAN 921.166370 are normally hot during and after operation. Allow the equipment time to cool before maintenance.
Should I drain the SEARS CRAFTSMAN 921.166370 if it has a leak?
If the tank of the SEARS CRAFTSMAN 921.166370 develops a leak, replace the air compressor. Never use the unit after a leak has been found.
What is the function of the Oil Sight Gauge on the SEARS CRAFTSMAN 921.166370?
The oil sight gauge on the SEARS CRAFTSMAN 921.166370 allows you to visually check that the oil level reaches the top of the red dot.
What does it mean if the SEARS CRAFTSMAN 921.166370 tank pressure gauge drops to zero?
This indicates that there is no reserve air pressure in the tank of the SEARS CRAFTSMAN 921.166370.
Are there electrical precautions for repairing the SEARS CRAFTSMAN 921.166370?
Any electrical issues or repairs for the SEARS CRAFTSMAN 921.166370 should be performed by authorized personnel such as an electrician and should comply with all national and local electrical codes.
How do I verify if the SEARS CRAFTSMAN 921.166370 is properly grounded?
Check with a qualified electrician or service personnel if you are in doubt as to whether the SEARS CRAFTSMAN 921.166370 is properly grounded.