What is the maximum resolution supported by the SC&T DP02U?
The maximum resolution supported by the SC&T DP02U is up to 4K@30Hz 4:4:4.
What is the maximum transmission distance for the SC&T DP02U using CAT5e or greater cable?
The signal extension for the SC&T DP02U is up to 150M over CAT5e or greater cable at 1080p@60Hz 8bit resolution. For 4K@30Hz 4:4:4 resolution, the maximum transmission distance is 100M over CAT6 / CAT6a/ CAT7 cable.
What are the key features of the SC&T DP02U?
The key features of the SC&T DP02U include:
Resolution up to 4K@30Hz 4:4:4.
Signal extension up to 150M over CAT5e or greater.
Built-in 4 ports USB at RX unit.
Supports bi-directional RS232 transmission.
What is the function of the Power Jack (Interface 1) on the SC&T DP02U units?
The Power Jack (Interface 1) is used to connect with the 5V 2A power adapter.
What do the Power Indication (Interface 2) and Link Indication (Interface 3) LEDs signify on the SC&T DP02U units?
The Power Indication (Interface 2) indicates the power status (Green ON/OFF). The Link Indication (Interface 3) indicates the link status (Blue ON/OFF, Flash for Power Saving Mode ON).
How are RS232 signals connected on the SC&T DP02U units?
The RS232 signal is connected via the 3.5 mm Phone Jack (Interface 4 on the DP02UT/DP02UR panel view on page 2, or Interface 4 on the panel view on page 3, or Interface 4 on the panel view on page 4). This is used to connect with an RS232 cable, as described in Description 2.
How are the Ethernet cable and DisplayPort cable connected to the SC&T DP02U units?
The Ethernet cable connects to the RJ45 Connector (Interface 5 on page 2, Interface 6 on page 3, Interface 6 on page 4) as described in Description 3. The DisplayPort cable connects to the DisplayPort Connector (Interface 6 on page 2, Interface 7 on page 3, Interface 7 on page 4).
How is the USB connection made for the SC&T DP02U units?
The USB connection is made via the USB-Type A Connector (Interface 7 on page 2) or USB-Type B Connector (Interface 5 on page 3, Interface 5 on page 4), depending on the unit and diagram. This is used to connect with a USB cable.
What are the pin definitions for the DB9(F)/3.5mm Stereo Phone Jack on the DP02UT for RS232?
The pin definitions for the DB9(F)/3.5mm Stereo Phone Jack on the DP02UT (DCE pin functions) are as follows:
| RS232 Footprint | Define | 3.5 mm Phone Jack Footprint | Define |
|---|---|---|---|
| Pin 2 | TX | Pin 1 | RX |
| Pin 3 | RX | Pin 2 | TX |
| Pin 5 | GND | Pin 3 | GND |
What are the pin definitions for the DB9(M)/3.5mm Stereo Phone Jack on the DP02UR for RS232?
The pin definitions for the DB9(M)/3.5mm Stereo Phone Jack on the DP02UR (DTE pin functions) are as follows:
| RS232 Footprint | Define | 3.5 mm Phone Jack Footprint | Define |
|---|---|---|---|
| Pin 2 | RX | Pin 1 | RX |
| Pin 3 | TX | Pin 2 | TX |
| Pin 5 | GND | Pin 3 | GND |
What is the RJ45 pinout for data transmission on the SC&T DP02U?
The RJ45 pinout for data on the SC&T DP02U is defined as follows:
| Pin | Color | Data |
|---|---|---|
| 1 | Orange-white | DATA0 + |
| 2 | Orange | DATA0 – |
| 3 | Green-white | DATA1 + |
| 4 | Blue | DATA2 + |
| 5 | Blue-white | DATA2 – |
| 6 | Green | DATA1 – |
| 7 | Brown-white | DATA3 + |
| 8 | Brown | DATA3 – |
What is the function of Switch 1 on the SC&T DP02U?
When Switch 1 is set to Off, it enables 4K Resolution. When set to On, it enables Long Reach Mode 1080p.
What is the function of Switch 2 on the SC&T DP02U?
When Switch 2 is set to Off, it enables RS232 transmission. When set to On, it is used for Firmware update.
What happens to the SC&T DP02U when there is no video displaying or no connection with any device?
When no video is displaying or no connecting with any device, the SC&T DP02U will automatically activate Power Saving Mode to disable RS232 and USB transmission function. This mode is indicated by the Link LED flashing.
What is the recommended cable type for connecting the DP02UT and DP02UR on the SC&T DP02U?
It is recommended using high-quality CAT5e, CAT6, CAT6a, CAT7 UTP/STP, or FTP cables to connect the DP02UT and DP02UR of the SC&T DP02U. Poor quality cables and any improper connection may cause video or audio disruptions and picture noise.
What is the maximum RS232 Baud Rate for the SC&T DP02U?
The RS232 Baud Rate for the SC&T DP02U is 115200 bps/ Full Duplex.
What is the RS232 transmission function when Switch 2 is set to Off on the SC&T DP02U?
When Switch 2 is set to Off on the SC&T DP02U, the RS232 function is enabled.
What should be done if the Ethernet cable for the SC&T DP02U passes through a wall socket?
If the Ethernet cable passes through the wall socket, the length of the cable between the DP02U (Tx or Rx unit) and the Wall Jack must be fewer than 3 meters.
What steps should be taken to troubleshoot connection issues with the SC&T DP02U related to electromagnetic waves?
To troubleshoot connection issues with the SC&T DP02U related to electromagnetic waves, you should ensure the connection cables keep a distance from any equipment with electromagnetic waves, such as mobile phones, microwaves, radio equipment, fluorescent lamps, and high voltage power lines.
What is recommended if interference is present when using multiple SC&T DP02U units?
If there is interference or multiple SC&T DP02U units are used in the environment, using STP or FTP cable is highly recommended.
What are the power consumption details for the SC&T DP02UT and DP02UR?
The power consumption for the SC&T DP02UT is 5W (Max), 1W (Power Saving). The power consumption for the SC&T DP02UR is 6W (Max), 1W (Power Saving).
What is the operational ambient temperature range for the SC&T DP02U?
The operational ambient temperature range for the SC&T DP02U is -10 to 45°C.
What are the dimensions of the SC&T DP02UT and DP02UR units?
The dimensions for both the SC&T DP02UT and DP02UR units are 109.6 x 108 x 30mm.
What is the weight of the SC&T DP02UT and DP02UR units?
The weight of both the SC&T DP02UT and DP02UR units is 265 (units are not specified but implied to be in grams or a similar standard unit based on context of specifications).
What are the contents included in the Package Includes for the SC&T DP02U?
The package includes the following items for the SC&T DP02U:
| Item | Amount |
|---|---|
| DP02UT (Transmitter Unit) | 1 pc |
| DP02UR (Receiver Unit) | 1 pc |
| DC5V2A Power Adapter | 2 pcs |
| USB A/B Cable | 1 pc |
| DB9 (Male) 3.5mm Stereo Phone Jack | 1 pc |
| DB9 (Female) 3.5mm Stereo Phone Jack | 1 pc |
| Mounting Screw pack | 1 bag |
What compliance standards does the SC&T DP02U adhere to?
The SC&T DP02U complies with DP 1.2a, HDCP, USB 2.0, 1.1, and 1.0.
What are the available Audio Formats supported by the SC&T DP02U?
The Audio Formats supported by the SC&T DP02U are LPCM 7.1 @ 192KHz, Dolby TrueHD, and DTS-HD MA.
What is the maximum transmission distance for the SC&T DP02U at 1080p@60Hz?
The maximum transmission distance for the SC&T DP02U at 1080p@60Hz is 150M.
What are the video input and output ports for the SC&T DP02UT?
The SC&T DP02UT has one DisplayPort for Video Input and one HDBaseT port for Video Output.
What are the video input and output ports for the SC&T DP02UR?
The SC&T DP02UR has one HDBaseT port for Video Input and one DisplayPort for Video Output.
What are the USB interfaces for the SC&T DP02UT and DP02UR?
The SC&T DP02UT has one USB-Type B interface. The SC&T DP02UR has four USB-Type A interfaces.
What are the RS232 interfaces for the SC&T DP02UT and DP02UR?
The SC&T DP02UT has one DB9(F)/3.5mm Stereo Phone Jack for the RS232 Interface. The SC&T DP02UR has one DB9(M)/3.5mm Stereo Phone Jack for the RS232 Interface.
What is the required power supply for the SC&T DP02U units?
The required power supply for both the SC&T DP02UT and DP02UR is DC 5V 2A Regulated.
What is the storage ambient temperature range for the SC&T DP02U?
The storage ambient temperature range for the SC&T DP02U is -30 to 70°C.
What is the maximum humidity level allowed for the SC&T DP02U operation?
The maximum humidity level allowed for the SC&T DP02U operation is up to 90%.
What connection should be avoided when using the HDBaseT port on the SC&T DP02U?
The HDBaseT technology on the SC&T DP02U does not communicate through the general Ethernet signal. Therefore, using the HDBaseT port to connect with network devices may cause damage to the extender.
What functionality is reserved (no function) for Switch 4 on the SC&T DP02U?
Switch 4 on the SC&T DP02U is reserved and has no function, regardless of whether it is set to Off or On.
Does the SC&T DP02U support MST (Multi Stream Transport) hub function based on DP1.2?
No, the SC&T DP02U device does not support MST (Multi Stream Transport) hub function based on DP1.2.