What are the specifications for the SCHEU ALL PRO SPC-48 heater?
The specifications for the SCHEU ALL PRO SPC-48 and related models are as follows:
TYPE OF GAS: For use with Propane Only
INPUT RATING:
12-IR 11,000 BTU/hr
24-IR/24-IRP 22,000 BTU/hr
36-IR 33,000 BTU/hr
48-IR 44,000 BTU/hr
MANIFOLD PRESSURE: 28″ Water Column
ORIFICE SIZE: No. 69 Drill
What are the main safety precautions for using the SCHEU ALL PRO SPC-48 heater?
Please follow these safety precautions when operating your SCHEU ALL PRO SPC-48 heater:
1. Check the heater thoroughly for damage. DO NOT operate a damaged heater.
2. Do not modify the heater or operate a heater which has been modified from its original condition.
3. Use only propane gas.
4. Use only VAPOR WITHDRAWAL propane cylinders. If there is any question about vapor withdrawal, ask your propane dealer.
5. Mount propane cylinders vertically (shutoff valve up). Secure them from falling or being knocked over and protect them from damage.
6. Do not direct heat toward propane cylinders.
7. Use only the hose and regulator assembly provided with the heater. Inspect hose assembly before each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with hose assembly listed on parts list before using heater. The hose and fittings shall be protected from damage and deterioration.
8. For indoor or outdoor use. AREA MUST BE WELL VENTILATED. Provide minimum openings of 1 sq. ft. near the floor and 1 sq. ft. near the ceiling.
9. If at any time gas odor is detected, IMMEDIATELY DISCONTINUE operation until the source of gas has been located and corrected.
10. Install the heater such that it is not directly exposed to water spray, rain, dripping water and/or wind.
11. Maintain minimum clearance from normal combustible materials (like paper) as follows: rear-2 ft.; sides-3 ft.; front-6 ft. Locate 10 ft. from canvas or plastic tarpaulins or similar coverings and secure them to prevent flapping or movement due to wind action.
12. Operate only on a stable, level surface.
13. Since permanent skin tissue damage can occur, avoid contact with the unit while it is operating or shortly after it has been shut off.
14. Operate the unit in a draft-free area or protect the heater from drafts.
15. Do not move, handle or service while hot or burning.
16. Use only in accordance with local codes or, in the absence of local codes, with the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58-1998, and National Fuel Gas Code ANSI Z223.1/NFPA.
What should I know about propane gas and potential leaks when using my SCHEU ALL PRO SPC-48 heater?
Propane is heavier than air. If propane leaks from a connection or fitting, it sinks to the floor, collecting there with the surrounding air, forming a potentially explosive mixture. Obviously, propane leaks should be avoided, so set up the propane supply with utmost care. Leak check new connections or reconnections with a soap and water solution and follow all connection instructions herein. Also ask your propane dealer for advice on the propane supply installation and ask him to check it if there are any questions.
My SCHEU ALL PRO SPC-48 is a direct-fired heater. What does this mean and what are the risks?
Direct-fired means that all of the combustion products from burning propane enter the heated space. Even though this heater operates very close to 100 percent combustion efficiency, it still produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic.
CO can build up in a heated space and failure to provide adequate ventilation could result in death. Be sure to follow advice about VENTILATION in these operating instructions.
What are the symptoms of inadequate ventilation when using the SCHEU ALL PRO SPC-48 heater?
The symptoms of inadequate ventilation due to carbon monoxide (CO) buildup are:
headache
dizziness
burning eyes and nose
nausea
dry mouth or sore throat
If these symptoms occur, it is critical to ensure proper ventilation.
How do I prepare my SCHEU ALL PRO SPC-48 heater for operation?
1. Inspect the heater for possible shipping damage. If any is found, immediately notify the dealer.
2. Follow all of the “Safety Precautions” and “Operating Information” guidelines.
3. The heater is to be hooked up to the regulator (set at 28″ water column) supplied with the heater.
How do I assemble the SCHEU ALL PRO SPC-48 heater?
Follow these steps for heater assembly:
a) Lay the heater reflector down on a flat level surface (the manifold mounting lug will be up).
b) Attach the manifold to the burner/reflector assembly as shown in the exploded view.
c) Be sure that the neck(s) of the manifold are pushed all of the way into the one (1) inch tube(s) of the burner assembly(s).
d) Position and tighten the adapter clamp(s).
e) The manifold mounting lug (the rectangular piece of 1/8″ thick steel that is welded to the manifold) must face the direction shown in the exploded view.
f) Attach the loose thermocouple end to the connection at the thermoelectric valve.
g) Tighten the connection finger tight, then tighten an additional maximum 1/4 turn using a 3/8″ open end wrench.
How do I mount the SCHEU ALL PRO SPC-48 heater to a propane cylinder?
For Quad-Head Heater Mounting (such as the SPC-48):
a) Mount the quad-head heater onto a 100# cylinder by placing the collar assembly over the threaded neck (for cylinder valve cover) and tighten the wing nut.
b) Place the slot in the heater support over the propane cylinder flange.
c) Tighten the lock bolt assembly, then secure with the nut.
After mounting:
8. Check the ‘O’ ring on the POL before each use. Replace the ‘O’ ring if there is any sign of wear or damage.
9. After the heater is securely attached to the propane cylinder connect the POL fitting of the hose and regulator assembly to the propane cylinder by rotating the POL nut counterclockwise into the propane cylinder’s valve outlet. Securely tighten with a wrench.
10. Securely tighten all gas connections.
11. Open the cylinder’s gas valve and check all gas connections with a soap and water solution. DO NOT USE A FLAME.
How do I start my SCHEU ALL PRO SPC-48 heater?
WARNING: DO NOT LOOK OVER TOP OF HEATER (REFLECTOR) DURING IGNITION. This heater may produce a small puff of flame during ignition, which could result in serious bodily injury.
1. Fully open the valve on the propane cylinder.
2. Depress the red button on the safety valve admitting gas to the heater. Place a lighted match near the face of the ceramic element using the hole located on the side of the reflector. If the hose is filled with air, allow a few seconds for gas to reach element. DO NOT LIGHT AT THE ORIFICE.
3. When the gas on the face of the ceramic element lights, continue to hold the button depressed for 30 seconds, then release. On multiple head units, check to see that all elements are burning.
4. If the flame goes out, wait 5 minutes and repeat the lighting procedure.
How do I stop my SCHEU ALL PRO SPC-48 heater?
1. Securely close valve at propane cylinder.
2. Do not attempt to relight for 5 minutes.
How do I restart my SCHEU ALL PRO SPC-48 heater after a safety shutdown?
1. Securely close valve at propane cylinder.
2. Wait 5 minutes.
3. Restart following “Start” procedure.
How can I tell if my SCHEU ALL PRO SPC-48 heater is working properly?
A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:
The flame is contained near the surface of the ceramic grid(s).
The flame is essentially blue.
There is no strong disagreeable odor, eye burning or other physical discomfort.
There is no smoke or soot internal or external to the heater.
There are no unplanned or unexplained shutdowns of the heater.
A heater which is not working right must be repaired, but only by a trained, experienced service person.
What are the maintenance and storage instructions for the SCHEU ALL PRO SPC-48 heater?
1. The heater should be inspected before each use, and at least annually by a qualified person.
2. Before each use, check the soft “O” ring seat at the bullnose of the POL fitting. If the “O” ring is cut, scuffed, or otherwise damaged, replace it with part number 6681.
3. Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.
4. When the heater is to be stored indoors, the connection between the LP-gas supply cylinder(s) and the heater must be disconnected and the cylinder(s) removed from the heater and stored outdoors and in accordance with Chapter 5 of the Standard for Handling of Gases ANSI/NFPA 58-1998.
What is the minimum recommended propane cylinder size and operating time for my SCHEU ALL PRO SPC-48 heater?
The following table outlines the minimum recommended cylinder size and approximate operating times at 60°F. If ambient temperatures will be less than 60°F, increase propane supply accordingly.
| HEATER MODEL | CYLINDER SIZE | OPERATING TIMES @60°F* |
|---|---|---|
| 12IR/SPC-12IR | 20# (5 – Gallons) | 30 – hours |
| 24IR/SPC-24IR | 20# (5 – Gallons) | 15 – hours |
| 24IR/SPC-24IRP | 20# (5 – Gallons) | 15 – hours |
| 36-IR/SPC-36IR | 40# (10 – Gallons) | 20 – hours |
| 48IR/SPC-48IR | 100# (25 – Gallons) | 35 – hours |
What is the “refrigeration effect” with propane fuel and how can I reduce it with my SCHEU ALL PRO SPC-48 heater?
During use, liquid propane in a container vaporizes. As it vaporizes, the propane cools itself. This cooling process is known as the refrigeration effect. If it continues long enough and proceeds fast enough, the propane temperature and pressure will fall so low that heater operation may be improper or even impossible even though plenty of propane remains in the container. Often frost forms on the outside of the propane container as a warning of excessive refrigeration.
Recommendations to reduce the ill effects of refrigeration effect are:
Provide considerable more propane than you plan to consume. As a rule of thumb, provide twice as much.
Fill containers frequently, especially in cold weather.
Never allow propane to fall below one-third of container capacity.
If possible, keep containers in a warm area (under no circumstances should the heater exhaust be directed toward the propane container).
What are the part numbers for the SCHEU ALL PRO SPC-48 and related heater models?
| Item No. | Description | 12IR | Qty. | 24IR | Qty. | 24IRP | Qty. | 36IR | Qty. | 48IR | Qty. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | Burner Assembly w/ceramic grid | 1010 | 1 | 1010 | 2 | 1010 | 2 | 1010 | 3 | 1010 | 4 |
| 2 | Hose Assembly | 1016 | 1 | 1016 | 1 | 1016 | 1 | 1016 | 1 | 1016 | 1 |
| 3 | Support Tube Assembly | 1017 | 1 | 1017 | 1 | 1017 | 1 | 1017 | 1 | 1017 | 1 |
| 4 | Reflector Assembly | 1009 | 1 | 1019 | 1 | 1019 | 1 | 1022 | 1 | 1025 | 1 |
| 5 | Manifold Assembly | 1014 | 1 | 1021 | 1 | 1021 | 1 | 1024 | 1 | 1027 | 1 |
| 6 | Bracket, Thermocouple | 3003 | 1 | 3003 | 1 | 3003 | 1 | 3003 | 1 | 3003 | 1 |
| 7 | Orifice, LP #69 Drill | 3008 | 1 | 3008 | 2 | 3008 | 2 | 3008 | 3 | 3008 | 4 |
| 8 | Keeper, Grid | 3017 | 2 | 3017 | 3 | 3017 | 2 | 3017 | 4 | 3017 | 5 |
| 9 | Bracket, Electrode Ground | 3645 | 1 | ||||||||
| 10 | Bracket, Piezo Mounting | 4291 | 1 | ||||||||
| 11 | Bracket, Label | 4292 | 1 | ||||||||
| 12 | Nut, flange Lock 3/8-16 | 6042 | 2 | 6042 | 2 | 6042 | 2 | 6042 | 2 | 6042 | 2 |
| 13 | Clip, Thermocouple | 6045 | 1 | 6045 | 1 | 6045 | 1 | 6045 | 1 | 6045 | 1 |
| 14 | Clamp, Loop 1″ Dia. | 6069 | 1 | 6069 | 2 | 6069 | 2 | 6069 | 2 | 6069 | 2 |
| 15 | Thermocouple, 12″ | 6233 | 1 | 6233 | 1 | 6233 | 1 | 6233 | 1 | 6233 | 1 |
| 16 | Regulator 28″ W.C. 1/4 x 3/8 FPT | 6257 | 1 | 6257 | 1 | 6257 | 1 | 6257 | 1 | 6257 | 1 |
| * | Manual, Operating Instructions | 6326 | 1 | 6326 | 1 | 6326 | 1 | 6326 | 1 | 6326 | 1 |
| * | Label, Warning, Fuel | 6369 | 1 | 5369 | 1 | 6369 | 1 | 6369 | 1 | 6369 | 1 |
| 19 | POL, Excess Flow 1/4 MPT | 6433 | 1 | 6433 | 1 | 6433 | 1 | 6433 | 1 | 6433 | 1 |
| 20 | Piezo Igniter | 6473 | 1 | ||||||||
| * | Label, Hangtag | 6712 | 1 | 6712 | 1 | 6712 | 1 | 6712 | 1 | 6712 | 1 |
| 22 | Nut, Piezo | 7161 | 1 | ||||||||
| 23 | Valve, Thermoelectric | 7285 | 1 | 7285 | 1 | 7285 | 1 | 7285 | 1 | 7285 | 1 |
| 24 | Electrode | 7395 | 1 | ||||||||
| * | Label, Mode/Opr. Instructions | 7608 | 1 | 7608 | 1 | 7608 | 1 | 7608 | 1 | 7608 | 1 |
| * | Label, Light Here | 7609 | 1 | 7609 | 1 | 7609 | 1 | 7609 | 1 | 7609 | 1 |
| * | Label, Warning/Ignition Flash | 8186 | 1 | ||||||||
| 28 | Screw, Machine 3/8-16 x 1 1/4 Grd 5 | 8190 | 2 | 8190 | 2 | 8190 | 2 | 8190 | 2 | 8190 | 2 |
| 29 | Collar, Assembly, 48IR | 1028 | 1 |