What are the specifications of the ROMED HOLLAND BP-1000?

Measurement Method Oscillometric
Measurement Range 30-280mmHg
Pulse Range 40 – 199p/min
Measurement Accuracy Pressure: ±3 mmHg
Pulse: ±5%
Cuff Size 52 x 13.5cm (normal cuff)
Operating Condition +10°C ~ + 40°C / 30%RH ~ 80%RH
Storage Condition -5°C ~ +35° / 30%RH ~ 80%RH
Power Supply 4 x AA batteries
Dimensions Approx. 150 (L) x 110 (W) x 65 (H) mm
Weight Approx. 370g not including batteries
Display LCD, backlit
Touch pad key Set/clock key
ON/OFF key
Memory key
Memory 99 measurements
Can display the average of the last 2 measurements

What safety instructions should be followed when using the ROMED HOLLAND BP-1000?

This device is for household use only. It is not intended as a substitute for consultation with your physician.

For users diagnosed with common arrhythmia (atrial or ventricular premature beats or atrial fibrillation), diabetes, poor blood circulation, kidney problems, or for users who suffered from stroke, or for unconscious users, the device might not be suitable for use. Consult your physician in case of any doubt.

This monitor should not be operated by children to avoid possible hazardous situations.

The device contains high-precision assemblies. Therefore, avoid extreme temperatures, humidity and direct sunlight. Avoid dropping or strongly shocking the main unit, and protect it from dust.

Leaking batteries can damage the device. Remove the batteries when the device is not used for a long time.

Do not activate the device when the cuff is not connected or the cuff is not wrapped on your arm.

Do not disassemble the monitor or cuff, do not wash the cuff.

If the device is stored in a cold place, allow the device to acclimatize at room temperature.

Clean the device’s body and the cuff carefully with a soft cloth. Do not press the LCD screen, do not clean the LCD screen with alcohol or petrol.

To avoid inaccurate results caused by electromagnetic interference between electrical and electronic equipment, do not use the device near a cell phone etc.


How do I install or replace the batteries in the ROMED HOLLAND BP-1000?

1. Press down and slide the battery cover in the direction of the arrow to open the battery compartment.

2. Install or replace 4 ‘AA’ batteries in the battery compartment, taking care that the polarities (+) and (-) are correct.

3. Slide the battery cover to close the battery compartment. Do not mix old and new batteries.

Use alkaline batteries to extend the batteries life.


When should I replace the batteries in the ROMED HOLLAND BP-1000?

You need to replace the batteries when:

1) The low battery icon appears on display. It will not appear when the battery is full.

2) Press the ON/OFF key but nothing appears on the display.


How do I adjust the time and date on the ROMED HOLLAND BP-1000?

Please switch the device to the “Power Off” status before time adjustment.

1. In the shutdown state press the Set/clock key to display the time.

2. Press the Set/clock key for more than 3 seconds to enter “set” mode. The display will show a blinking number showing the year. Press the Memory key to get the desired year.

3. Press the Set/clock key again, the display will show a blinking number showing the month. Press the Memory key to get the desired month. Then press the Set/clock key again to adjust the day. Press the Memory key to get the desired day.

4. Press the Set/clock key, the display will show a blinking number showing the hour/minute, operate according to “step 3” to get the desired time.

5. Press the ON/OFF key during the time adjustment procedure to stop the time adjusting process directly. The adjustment result will be saved.


How do I erase stored memories on the ROMED HOLLAND BP-1000?

1. In the “set” mode, after setting the time, press the Set/clock key again to see the symbol “CL” appear on the LCD, blinking.

2. Long press the Memory key until the LCD shows “CL”, and press the Memory key again to confirm the erasing of all the measurement results.

3. Press the ON/OFF key to get back to ‘Stand By’ status.


How do I use the touch keys on the ROMED HOLLAND BP-1000?

When installing the battery don’t touch the key pad. The screen will display “AA”, and then it will go out later.

When you turn on the device by using the touch keys, you should press the touch key for 1 ~ 2 seconds continuously.

If the touch key doesn’t work properly, please move away your finger, wait for 4-10 seconds, it would return to correct state.


How do I apply the cuff for the ROMED HOLLAND BP-1000?

1. Plug in the cuff connecting tube into the unit and unwrap the arm cuff, leaving the “Index” end of the cuff through the D-ring.

2. Put the cuff on your left arm, make sure the air tube is in the inside of the elbow.

3. Turn your left palm upward and adjust the edge of the cuff at approximately 2-3cm above the elbow.

4. Adjust your cuff’s air tube, the air tube shall lie over the brachial artery on the inside of the arm. The tube should run down the centre of the arm.

5. Tighten the cuff by pulling the ‘Index’ end of the cuff.

Note: Regarding the “PROPER FIT RANGE”: If the Index arrowhead falls within the “PROPER FIT RANGE”, it indicates that this cuff is suitable for you. If the Index arrowhead falls out of the “PROPER FIT RANGE” you may need a small/large cuff for measurement. Please consult your seller about changing cuff.


What is the proper procedure for taking a measurement with the ROMED HOLLAND BP-1000?

Important tips for the most accurate blood pressure measurements:

Sit comfortably at a table and rest your arm on the table.

Relax for about five to ten minutes before measurement.

Place the centre of the cuff at the same height as your heart.

Remain still and keep quiet during the measurement.

Do not measure right after physical exercise or a bath.

Rest twenty to thirty minutes before taking the measurement.

Try to measure your blood pressure at the same time every day.


How do I take a blood pressure measurement using the ROMED HOLLAND BP-1000?

1. Press the ON/OFF key. All digits will light up, checking the display functions. The checking process will be completed after about 2 seconds.

2. After all symbols appear, the display will show a blinking “0”. The monitor is now ready to measure and will automatically inflate to a settled pressure value around 180mmHg. This monitor will re-inflate automatically to approximately 210mmHg, if the system detects your body needs more pressure to take the measurement.

3. After inflating to the settled pressure, the device starts to deflate, when the heartbeat was detected, a heart symbol will blink on the display. The blinking heart mark blinks with each heartbeat.

4. When the measurement is completed, the cuff will deflate automatically. Systolic, diastolic and pulse with date/time will be shown simultaneously on the LCD screen. The measurement results will be stored automatically. If a mistake was detected during the measurement, the symbol ‘E’ will display on the screen.

5. Press the ON/OFF key to switch off the device. Untie the cuff and pack the device in the box to preserve the device.

Note: This monitor will automatically switch off after 3 minutes. To stop the measurement procedure, please press the ON/OFF key directly.


How do I recall memory on the ROMED HOLLAND BP-1000?

1. In the ‘Stand By’ status. Press the Memory key to enter into memory recall function.

2. After pressing the Memory key, a symbol “A” will be displayed. The average systolic, diastolic and pulse of the last 2 measurements will display. Note: The “A” symbol means average.

3. Pressing the Memory key again to get the latest results. By pressing the Memory key to get the desired measurement results.

4. Hold the Memory key, the memory number will increase quickly, release the Memory key to get the desired measurement results.

5. After the earliest measurement results were displayed, the number goes to “1”.

6. Press the ON/OFF key to finish recall memories and get back to “Stand By” status.


How do I troubleshoot problems with the ROMED HOLLAND BP-1000?

Problem Possible Reason Recommended Action
Nothing appears on the display, even when the power is turned on. Batteries are drained Replace all batteries with new ones
Nothing appears on the display, even when the power is turned on. Battery terminals are not in the correct position Reinstall the batteries with negative and positive terminals matching those indicated on the battery compartment
The cuff does not inflate Battery voltage is too low. The LOW BATTERY mark blinks. If the batteries are drained completely, the mark does not appear. Replace all batteries with new ones
The unit does not measure The cuff is not fastened properly. Fasten the cuff correctly
The unit does not measure You moved your arm or body during the measurement. Make sure you remain very still and quiet during the measurement
The unit does not measure The cuff position is not correct. Sit comfortably and still. Raise your hand so that the cuff is at the same level as your heart
Measurement values appear too high or too low. If you have a very weak or irregular heartbeat the device may have difficulty in determining your blood pressure Blood pressure varies constantly. Many factors including stress, time of day and how you wrap the cuff may affect your blood pressure. Review the section “Take a Measurement”
Other The value is different from that measured at a clinic or doctor’s office. Being at a clinic may cause apprehension. The pressure may higher by 25-30 mmHg.
Other —————— Remove the batteries. Place them back properly and try the measurement again

How do I maintain the ROMED HOLLAND BP-1000?

1. Do not drop this monitor or subject it to strong impact.

2. Avoid high temperature and solarization. Do not immerse the monitor in water as this will result in damage to the monitor.

3. If this monitor is stored near freezing, allow it to acclimate to room temperature before use.

4. Do not attempt to disassemble this monitor.

5. If you do not use the monitor for a long time, please remove the batteries.

6. If the monitor becomes dirty, please clear it with a soft dry cloth. Do not use any abrasive or volatile cleaners.

7. No component inside the monitor can be maintained by user.


What do the symbols on the ROMED HOLLAND BP-1000 unit mean?

Probe: Type BF Applied part
Serial number
Batch code
Catalogue number.
CE Mark
Date of manufacture
Manufacturer
Keep dry
Keep away from sunlight
Temperature limit
Collect separately from other household waste
Refer to user manual
Consult instructions for use
Caution