If this is not the document you want for this product, click here to see if we have any other documents for this product.
RESPEKTA CH 55060 SA++ (SAPLUSPLUS) (01) PDF SUMMARY:
How do I install the V-Flaps if they are not factory-mounted?
First, install half part 1 in connection nozzle B10. Ensure pins 3 are in the upwards position. Insert the axle 4 into the holes 5 on the nozzle B10. Repeat these steps for mounting half part 2.
How do I install the hood for recirculation mode?
- Place the lower chimney shaft on the hood.
- Using a pencil, draw a horizontal line on the wall at the height where the hood bottom edge should lie, using a water level for accuracy. Note the minimum distance according to chapter 11.1 of the operating instructions.
- Hold the supplied drill template with the bottom edge on the drawn pencil line against the wall and mark the four drill holes. (Fig. a)
- Drill a 30mm deep hole in the wall with an 8mm masonry drill at the 4 pencil marks. Check the diameter of the plugs with a caliper gauge for safety.
- Place one plug into each of the 4 holes.
- Screw a ST4 × 30mm screw into the two upper dowels. (Fig. a) Ensure the screw heads protrude 3 – 5 mm out of the dowels so that the hood can be hanged on them (readjust if needed).
- Hang the hood with the two eyelets on its back (Fig. b) by the two screws on the wall.
- Mount the stabilizer- and mounting plate at the top of the lower flue with two ST4 * 8mm screws. (Fig. c)
- Firmly press the chimney shaft against the wall and mark with pencil the two drill holes through the holes in the chimney stabilize- and mounting plate. (Fig. d)
- Remove the chimney from the hood.
- Drill two 40mm deep holes into the wall at the marked locations using an 8mm masonry drill.
- Push the upper (inner) chimney shaft from above into the lower (outer) chimney shaft.
- Place the nested chimneys on the hood.
- Pull the inner chimney shaft straight up to the ceiling and place one marking line on the sides of the shaft. (Fig. e)
- Remove the chimneys from the hood.
- Hold the upper (inner) chimney mounting bracket (Fig. f) at the top center of the ceiling between the drawn marks (Fig. e) and mark the drilled holes with the two holes (Fig. f) in the mounting bracket a pencil.
- Using an 8mm masonry drill, drill two 40mm deep holes at the pencil markers and place two plugs.
- Fix the inner chimney mounting bracket (Fig. f) to the wall with two ST4 × 40mm screws at the top of the ceiling.
- Place the two nested chimneys on the hood.
- Slide the inner chimney shaft all the way down.
- Attach the lower chimney stabilize- and mounting plate (Fig.d) to the wall with two ST4 x 40mm screws.
- Fix the lower chimney shaft with two ST4 * 8mm screws on the sides of the hood (Fig. g).
- Pull the upper (inner) chimney shaft all the way up and secure it to the mounting bracket with two ST4 * 8mm screws. (Fig. h)
- Lift the hoods on the front, remove the grease filter and secure the hood from the inside with two ST4 × 30mm screws through the 2 holes in the hood back panel to secure the hood. (Fig. i)
- Mount the carbon filters on the sides of the motor. (See user’s manual chapter “Using the carbon filters”)
What is included in the accessory list?
- Lower chimney a) and upper chimney b)
- Upper chimney bracket
- Lower chimney stabilizer- and fixing bar
- Wall plug φ8
- Screw ST4×40mm (2 for upper chimney mounting bracket, 2 for lower cimney mounting plate)
- Screw ST4×30mm (2 pcs for hood hanging, 2 pcs for hood locking)
- ST4*8 screw (Upper- and lower Chimney fixing)
- V-Flap
- Air exhaust pipe
- Ribbon-8×550mm
What are the general installation overview steps?
- Chimney fixing bar
- Upper chimney mounting bracket
- Hood suspension
- Hood safing screws
- Air exhaust pipe
- V-Flap
*The screws installed should leave for 3-5mm out of the wall to hang the hood on them
What should I do before beginning the installation?
Make sure the power supply is secure and that it is set up by a specialist. Also, insert the V-Flaps as described.
How do I mount the hood for exhaust air operation?
- Remove the outer and inner chimney.
- Mount the exhaust hose. (Fig. k)
- Replace the outer and inner chimney shaft.
For the final assembly of the hood in exhaust air operation, an exhaust grille with a 150mm socket (a) is needed for the connection of the exhaust air hose, which is not included. The wall duct must be dimensioned for a 150 mm exhaust hose (Drill hole about 155mm). To mount the hood in exhaust air mode, mount it as described for recirculation mode, but without mounting the carbon filters.