PDF Content Summary: Hardware Guide | November 2019 LP1108 | Revision A NT328G Industrial Ethernet Managed Switch Series COPYRIGHT ©2019 Red Lion Controls, Inc. All rights reserved. Red Lion and the Red Lion logo are registered trademarks of Red Lion Controls, Inc. All other company and product names are trademarks of their respective owners. Red Lion Controls, Inc. 20 Willow Springs Circle York, PA 17406 CONTACT INFORMATION: AMERICAS Inside US: +1 (877) 432-9908 Outside US: +1 (717) 767-6511 Hours: 8 am-6 pm Eastern Standard Time (UTC/GMT -5 hours) ASIA-PACIFIC Shanghai, P.R. China: +86 21-6113-3688 x767 Hours: 9 am-6 pm China Standard Time (UTC/GMT +8 hours) EUROPE Netherlands: +31 33-4723-225 France: +33 (0) 1 84 88 75 25 Germany: +49 (0) 1 89 5795-9421 UK: +44 (0) 20 3868 0909 Hours: 9 am-5 pm Central European Time (UTC/GMT +1 hour) Website: http://www.redlion.net Support: support.redlion.net Drawing No. LP1108 Table of Contents Revision A

NT328G Industrial Ethernet Managed Switch Series Table of Contents 3

Preface 5 Disclaimer 5 Purpose 5 Audience 5 Prerequisite Knowledge 5 Compliance Information 5 FCC Statement 5 Déclaration de conformité FCC 6 Industry Canada 6 Safety Instructions 6 Document Conventions 7 Regulatory Information 8 Access to Hardware Interface 9 Trademark Acknowledgments 9 Document History and Related Publications 9 Related Documents 9 Additional Product Information 9 Chapter 1 Introduction 11 Overview 11 Features and Benefits 11 DIMENSIONS In inches (mm) 12 Model Layouts - Front 13 NT328G-20SFP 13 NT328G-04SFP 13 Model Layouts - Rear 13 1 AC Power Models 13 2 AC Power Models 13 Technical Specifications 14 NT328G-04SFP Specifications 14 NT328G-20SFP Specifications 15 Transceiver Characteristics 16 100Base SFP Fiber Transceiver Characteristics (NT328G-20SFP Model Only) 16 Gigabit SFP Fiber Transceiver Characteristics 16 10 Gigabit SFP+ Fiber Transceiver Characteristics 16 Chapter 2 Installation 17 Contents of Package 17 Rack Mounting the Switch 17 Connecting to Earth Ground 18 Alarm Relay Connecting 18 Power Connections 19 Table of Contents Drawing No. LP1108 Revision A Terminal Block Connector 19 Connecting to the Ethernet Port (RJ45 Ethernet) 19 Connecting to the Ethernet Port (Fiber, SFP/SFP+) 19 LED Status Indications 20 Console Connection 21 Connect & Login to the Switch 21 CLI Initialization & Configuration (Optional) 21 CLI Command 21 Web Interface Initialization (Optional) 22 Web Browser Support 22 System Reset 22 Ordering Information 23 Accessories 23 Service and Support Information 25 Service Information 25 For Your Convenience: 25 Product Support 25 LIMITED WARRANTY 26 NT328G Industrial Ethernet

4 Managed Switch Series

Drawing No. LP1108 Preface Revision A Disclaimer Preface Disclaimer While every effort has been made to ensure that this document is complete and accurate at the time of release, the information that it contains is subject to change. Red Lion Controls is not responsible for any additions to or alterations of the original document. Industrial networks vary widely in their configurations, topologies, and traffic conditions. This document is intended as a general guide only. It has not been tested for all possible applications, and it may not be complete or accurate for some situations. Users of this document are urged to heed warnings and cautions used throughout the document. Purpose This guide provides an overview of the NT328G Rackmount Layer 3 Switch as implemented in the current version of software. These commands are used to set-up and execute applications on the device. Audience This guide is intended for use by network administrators, system engineers or other operating personnel who are responsible for operating and maintaining networking equipment; consequently, it assumes a basic working knowledge of general switch functions. Prerequisite Knowledge The reader must be familiar with the: ● Basic operations of the switch ● Security and activity monitoring constraints that limit how a command is implemented Compliance Information FCC Statement This product complies with Part 15 of the FCC-A Rules. Operation is subject to the following conditions: 1. This device may not cause harmful Interference 2. This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.

NT328G Industrial Ethernet Managed Switch Series 5

Preface Drawing No. LP1108 Safety Instructions Revision A Déclaration de conformité FCC Ce produit est conforme à la partie 15 des règles de la FCC –A Utilisation est soumise aux conditions suivantes: 1. Ce dispositif ne doit pas causer des interférences nuisibles 2. Cet appareil doit accepter toute interférence reçue, y compris les interférences qui peuvent causer un mauvais fonctionnement. Note: Cet équipement a été testé et jugé conforme aux limites de la classe A des appareils numériques , conformément à la partie 15 des règles de la FCC . Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation résidentielle . Cet équipement génère, utilise et peut émettre de l’énergie radiofréquence et, si il n’est pas installé et utilize conformément aux instructions, peut causer des interférences nuisibles aux communications radio. L’utilisation de cet appareil dans une zone résidentielle est susceptible de provoquer des interférences nuisibles, auquel cas l’utilisateur sera tenu de corriger les interférences à ses propres frais . Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions; (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe A répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée. Safety Instructions When a connector is removed during installation, testing, or servicing, or when an energized fiber is broken, a risk of ocular exposure to optical energy that may be potentially hazardous occurs, depending on the laser output power. Lorsqu’un connecteur est retiré pendant l’installation, le test ou l’entretien, ou lorsqu’une fibre sous tension est brisée, un risque d’exposition oculaire à une énergie optique potentiellement dangereuse se produit, selon la puissance de sortie du laser. DANGER: Class 1 Laser Product. Do not stare into the laser. AVERTISSEMENT: Produit Laser Lasse 1. Ne pas dans le laser. The primary hazards of exposure to laser radiation from an optical-fiber communication system are: ● Damage to the eye by accidental exposure to a beam emitted by a laser source. ● Damage to the eye from viewing a connector attached to a broken fiber or an energized fiber. Les principaux dangers de l’exposition au rayonnement laser provenant d’un système de communication à fibres optiques sont: ● Dommage à l’oeil par exposition accidentelle à un faisceau émis par une source laser. ● Dommage pour les yeux dû au fait de voir un connecteur relié à une fibre cassée ou à une fibre sous tension. The equipment has hot surfaces. NT328G Industrial Ethernet

6 Managed Switch Series

Drawing No. LP1108 Preface Revision A Document Conventions DANGER: Hot Surface. During operation, take care to avoid coming into contact with a hot surface. Do not touch it over 1 second. AVERTISSEMENT: Surface chaude! Pendant l’opération, en prenant soin d’éviter d’entrer en contact avec une surface chaude. Ne le touchez pas plus d’une seconde. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Changes or modifications to the equipment, which are not approved by the party responsible for compliance, could affect the user’s authority to operate the equipment. Si l’équipement est utilisé d’une manière non spécifiée par le fabricant, la protection fournie par l’équipement peut être compromise. Les changements ou modifications apportés à l’équipement, qui ne sont pas approuvés par la partie responsable de la conformité, pourraient affecter le pouvoir de l’utilisateur d’utiliser l’équipement. Document Conventions The following conventions are used in this manual to emphasize information that will be of interest to the reader. Danger DANGER: The described activity or situation might or will cause personal injury. AVERTISSEMENT: L’activité ou la situation décrite pourrait ou causera des blessures corporelles. WarningWARNING: The described activity or situation might or will cause equipment damage. AVERTISSEMENT: L’activité ou la situation décrite peut ou causera des dommages matériels. Caution CAUTION: The described activity or situation might or will cause service interruption or degradation. AVERTISSEMENT: L’activité ou la situation décrite peut ou causera une interruption ou une dégradation du service. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

NT328G Industrial Ethernet Managed Switch Series 7

Preface Drawing No. LP1108 Regulatory Information Revision A Regulatory Information Product Safety UL 61010 Ordinary Locations ANSI/ISA-12.12.01, Class I and II, Division 2 and Class III, Divisions 1 and 2 Groups A, B, C and D Hazardous Locations C22.2 No. 61010 Ordinary Locations C22.2 No. 213 Class I, Division 2 Hazardous Locations EMI/EMC CFR 47, Part 15, Subpart B Innovation, Science and Economic Development Canada ICES-003 Issue 6 ANSI C63.4:2014 EN 61000-6-2 Generic standards - Immunity standard for industrial environments EN 61000-6-4 Generic standards - Emission standard for industrial environments IEC 61000-4-2 (ESD) IEC 61000-4-3 (Radio-Frequency Electromagnetic Field) IEC 61000-4-4 (Fast Transient) IEC 61000-4-5 (Surge) IEC 61000-4-6 (Radio-Frequency Continuous Conducted) IEC 61000-4-8 (Power Frequency Magnetic Field) IEC 61000-4-11 (Voltage Dips, Short Interruptions) IEC 61000-4-16 (Mains Frequency Voltage) IEC 61000-4-18 (Damped Oscillatory Wave) Shock & Vibration IEC 60068-2-6: 2 g @ 5-500 Hz 2 g Tri-Axle IEC 60068-2-27: 50 g @ 11 ms Tri-Axle IEC 60068-2-32: Test Ed: Free Fall Rail EN 50155, EN 50121 and EN 61373 Other RoHS compliant NT328G Industrial Ethernet

8 Managed Switch Series

Drawing No. LP1108 Preface Revision A Access to Hardware Interface Access to Hardware Interface Access to the hardware interface is by a terminal (or computer with terminal emulation software). Requirements for the terminal are: ● RS-232 ASCII port ● Selectable transmission baud rate ● Full alphanumeric capability ● Selectable odd/even or no parity check Trademark Acknowledgments Red Lion Controls acknowledges and recognizes ownership of the following trademarked terms used in this document. ● Ethernet is a registered trademark of Xerox Corporation. All other company and product names are trademarks of their respective owners. Document History and Related Publications The hard copy and electronic media version of this document are revised only at major releases and therefore, may not always contain the latest product information. The latest online version of this document can be accessed through the Red Lion website at http://www.redlion.net/support/documentation. Related Documents Available documents related to this product can be accessed at http://www.redlion.net/support/documentation. ● LP1105 - NT328G Industrial Ethernet Managed Switch Software Guide Additional Product Information Additional product information can be obtained by contacting the local sales representative or Red Lion through the contact numbers listed on the inside of the front cover.

NT328G Industrial Ethernet Managed Switch Series 9

Preface Drawing No. LP1108 Document History and Related Publications Revision A NT328G Industrial Ethernet

10 Managed Switch Series

Drawing No. LP1108 Chapter 1 Introduction Revision A Overview Chapter 1 Introduction Overview The Red Lion® NT328G, Layer 3 rackmount industrial Ethernet switch, offers 28 high speed ports (24 Gigabit, 4 10 Gigabit) to meet the performance requirements of bandwidth intensive applications. Designed to meet current and future needs with reliable wire-speed switching performance and a flexible mix of copper and fiber ports, the NT328G’s robust feature set includes network redundancy, advanced security, policy-based traffic control and easy-to-use configuration and management. Housed in a rugged IP30 metal enclosure, the switch is designed for long-life use in harsh industrial environments, including wide operating temperature conditions and hazardous locations. Features and Benefits Features and Benefits Product Highlights • 24 Gigabit Copper Ports or 8 Gigabit Copper Ports and 16 Gigabit SFP Ports • 4 10G SFP+ Ports Supports 10G SFP+ Fiber or 1G Copper/ Fiber SFP Transceivers Management • RMON (Monitors L1 to L2 Traffic) • Configuration Backup/Restore • DHCP Server/Client/Relay Agent with Option 61, Option 82 • IGMP v1, v2, v3 • SNMP v1, v2, v3 • Port Mirroring • Event Log/Syslog • Advanced VLAN Operations • LLDP • Web Browser Management • CLI; Console, Telnet, SSH Network Redundancy • High-Speed Ring Protocol with <20ms Heal Time • Chain Protocols • LACP (Port Trunking) • Up to 14 Trunks per Switch • Up to 8 Ports per Trunk • IEEE 802.1D STP, IEEE 802.1w RSTP, IEEE 802.1s, 802.1Q MSTP NT328G Industrial Ethernet Managed Switch Series QoS/Rate Limiting/Traffic Control • QoS: Traffic Policing, Traffic Shaping, Queue Scheduling Policy/Profile-based Access Control List: • IP/MAC/TCP/UDP/ToS/DSCP • CoS/DSCP: SPQ, WRR, SPQ+WRR • Rate Limiting / Traffic Control: Storm Control • Multicast/Unicast Filtering Routing • GVRP • IEEE 802.1 AD (QinQ) • VRRP v2, v3 • RIP v1, v2 • OSPF • Static Routing • L3 Forwarding Security • SNMP v3 • SSH, SSL, HTTPS • Access Control List • 802.1X port authentication • 802.1X user login authentication • IP Source Guard (DHCP) C UR L US LISTED IND.CONT. 5LS7/5MP5 EQ. compliant EN50155 50 11

Chapter 1 Introduction Drawing No. LP1108 DIMENSIONS In inches (mm) Revision A DIMENSIONS In inches (mm) Number of power inputs is model dependent. See Model Layouts - Rear for more information. 17.31 (439.60) Port configurations are model dependent. See Model Layouts - Front for more information. 1.25 1.73 (31.75) (44.00) 18.15 (461.00) 18.46 (469.00) 18.98 (482.00) 17.31 (439.60) 11.81 12.41 12.33 (300.00) (315.30) (313.30) NT328G Industrial Ethernet 12 Managed Switch Series

Drawing No. LP1108 Chapter 1 Introduction Revision A Model Layouts - Front Model Layouts - Front NT328G-20SFP 8 10/100/1000Base T(X) Ports, 16 100/1000Base SFP Ports and 4 10G SFP+ Ports NT328G-04SFP 24 10/100/1000Base T(X) Ports and 4 10G SFP+ Ports Model Layouts - Rear 1 AC Power Models 2 AC Power Models NT328G Industrial Ethernet Managed Switch Series 8 10/100/1000Base T(X) Ports 4 10G SFP+ Fiber Ports* *Backwards compatible to 1G copper and fiber SFP tranceivers. 16 100/1000Base SFP Ports 4 10G SFP+ Fiber Ports* *Backwards compatible to 1G copper and fiber SFP tranceivers. 24 10/100/1000Base T(X) Ports USB Port Terminal block for Alarm Relay output Grounding screw PWR1: AC Power Input USB Port Terminal block for Alarm Relay output Grounding screw PWR1: AC Power Input PWR2: AC Power Input 13

Chapter 1 Introduction Drawing No. LP1108 Technical Specifications Revision A Technical Specifications ETHERNET Ethernet 100/1000Base SFP slots or 10/100/1000BaseT(X) for 24 gigabit ports Interface 10G SFP+ (1G SFP backward compatible) for 4 SFP+ slots POWER Power Input Options NT328G Industrial Ethernet Managed Switch Series Input Voltage Range Maximum Power Consumption Single/Dual AC inputs 100-240 VAC, 50 Hz - 60 Hz 35 W ENVIRONMENTAL AND COMPLIANCES Operating Temperature Range Storage Temperature Range Humidity (non-condensing) Operating Altitude -40 to 75°C -40 to 85°C 5 to 95% RH Up to 10,000 ft MECHANICAL Ingress Protection Height Width Depth Weight Installation Option IP30 1.73" (44.00 mm) 17.31" (439.60 mm) 12.41" (315.30 mm) 7.19 lbs. (3.26 kg) (maximum, NT328G-20SFP-AC2) 19" rack mounting RECOMMENDED MINIMUM WIRING CLEARANCE Back 2.00" (50.80 mm) Front 4.00” (101.60 mm) NT328G-04SFP Specifications NT328G-04SFP-AC1 SPECIFICATIONS NT328G-04SFP-AC2 SPECIFICATIONS Weight: 6.28 lbs. (2.85 kg) Weight: 6.75 lbs. (3.06 kg) Input Voltage: 100-240 VAC Input Voltage: 100-240 VAC Steady Input Current: 470 mA @ 120 VAC Steady Input Current: 470 mA @ 120 VAC BTU/hr: 192 @ 120VAC BTU/hr: 192 @ 120 VAC NETWORK AND MEDIA SPECIFICATIONS CONNECTOR SPECIFICATIONS 10BaseT: ≥Cat3 Cable 10/100/1000BaseT(X): Twenty-four (24) RJ45 TX Copper Ports 100BaseTX: ≥Cat5 Cable 1000 BaseT SFP Port: Up to four (4) RJ45 SFP Copper Transceiver Ports 1000BaseT: ≥Cat5e Cable 1000 BaseSX/LX SFP Port: Up to four (4) LC SFP Fiber Transceiver Ports 1000BaseSX Multimode: 50-62.5/125μm 10G BaseSR/LR SFP Port: Up to four (4) LC SFP Fiber Transceiver Ports 1000BaseLX Singlemode: 7-10/125μm 10GBaseSR Multimode: 50/125μm 10GBaseLR Singlemode: 9/125μm 14

Drawing No. LP1108 Chapter 1 Introduction Revision A NT328G-20SFP Specifications NT328G-20SFP Specifications NT328G-20SFP-AC1 SPECIFICATIONS NT328G-20SFP-AC2 SPECIFICATIONS Weight: 6.72 lbs. (3.05 kg) Weight: 7.19 lbs. (3.26 kg) Input Voltage: 100-240 VAC Input Voltage: 100-240 VAC Steady Input Current: 500 mA @ 120 VAC Steady Input Current: 500 mA @ 120 VAC BTU/hr: 205 @ 120 VAC BTU/hr: 205 @ 120 VAC NETWORK MEDIA SPECIFICATIONS CONNECTOR SPECIFICATIONS

10BaseT: ≥Cat3 Cable 10/100/ 1000BaseT(X): Eight (8) RJ45 TX Copper Ports NT328G Industrial Ethernet Managed Switch Series 15

100BaseTX: ≥Cat5 Cable 100BaseFX SFP Port: Up to sixteen (16) LC SFP Fiber Transceiver Ports 1000BaseT: ≥Cat5e Cable 1000BaseT SFP Port: Up to twenty (20) RJ45 SFP Copper Transceiver Ports

100BaseFX, 1000BaseSX Multimode: 50-62.5/125μm 1000BaseSX/LX SFP Port: Up to twenty (20) SFP Fiber Transceiver Ports Up to twenty (20) SFP Fiber Transceiver Ports Up to twenty (20) SFP Fiber Transceiver Ports 100BaseFXE, 1000BaseLX Singlemode: 7-10/125μm 10GBaseSR/LR SFP Port: Up to four (4) LC SFP Fiber Transceiver Ports Up to four (4) LC SFP Fiber Transceiver Ports Up to four (4) LC SFP Fiber Transceiver Ports

10GBaseSR Multimode: 50/125μm 10GBaseLR Singlemode: 9/125μm Chapter 1 Introduction Drawing No. LP1108 Transceiver Characteristics Revision A Transceiver Characteristics 100Base SFP Fiber Transceiver Characteristics (NT328G-20SFP Model Only) Fiber Mode MM SM SM SM Fiber Length* 2 km 15 km 40 km 80 km TX Power Min. -19 dBm -15 dBm -5 dBm -5 dBm RX Sensitivity Max. -31 dBm -34 dBm -34 dBm -34 dBm Wavelength 1310 nm 1310 nm 1310 nm 1550 nm Laser Type FP FP FP DFB Gigabit SFP Fiber Transceiver Characteristics Fiber Mode MM SM SM SM Fiber Length* 550m @ 50/125 μm 10 km 40 km 80 km 275m @ 62.5/125 μm TX Power Min -9.5 dBm -9.5 dBm -2 dBm 0 dBm RX Sensitivity Max -17 dBm -20 dBm -22 dBm -24 dBm Wavelength 850 nm 1310 nm 1310 nm 1550 nm Laser Type VCSEL FP DFB DFB 10 Gigabit SFP+ Fiber Transceiver Characteristics Fiber Mode MM SM SM SM Fiber Length* 300 m 10 km 40 km 80 km TX Power Min -7.3 dBm -8.2 dBm -4.7 dBm -1.0 dBm RX Sensitivity Max -11.1 dBm -12.6 dBm -15.8 dBm -23 dBm Wavelength 850 nm 1310 nm 1550 nm 1550 nm Laser Type VCSEL DFB EML EML * Fiber Length distances represent typical performance. Link budgets should be evaluated based on specific application conditions. ** SFP transceivers sold separately. NT328G Industrial Ethernet 16 Managed Switch Series Drawing No. LP1108 Chapter 2 Installation Revision A Contents of Package Chapter 2 Installation Contents of Package Carefully remove the switch and accessories from the shipping container and inspect them for damage. Contact Red Lion immediately if any damage is discovered. Please verify that the box contains the following items: - (1) Rack-mount Ethernet switch - (2) Rack-mount brackets - (4) Screws for brackets - (1) Console cable - (1) ALM terminal block (2-pin) - (1) Documentation CD - (12) RJ45 and (2) SFP dust covers (NT328G-04SFP) - (4) RJ45 and (10) SFP dust covers (NT328G-20SFP) Rack Mounting the Switch When mounting the switch, practice good safety habits. Relay rack mounting normally requires at least two people. 1. Obtain the tools required for mounting the hardware. 2. Attach the mounting brackets to the switch by using the screws in the accessory kit. 3. Secure the switch in its relay location on both the left and right sides of the mounting bracket. Tighten screws with 4.3-5.2 inch-lbs. Note: The industrial control panel rated ambient temperature required is 75 °C min. Note: La température ambiante nominale du panneau de commande industriel requis était de 75 °C min.

NT328G Industrial Ethernet Managed Switch Series 17

Chapter 2 Installation Drawing No. LP1108 Connecting to Earth Ground Revision A Connecting to Earth Ground The switch must be properly grounded for optimal system performance. The grounding connection is for both PE and FG. WARNING: The grounding pin of the AC power connector and middle pin of the DC power terminal block have no function. Only use the device grounding screw for a correct installation. AVERTISSEMENT: La broche de mise à la terre du connecteur d’alimentation secteur et la broche centrale du bloc de borne d’alimentation CC n’a aucune fonction. Utilisez uniquement la vis de mise à la terre de l’appareil pour une installation correcte. Use 18AWG-12AWG wire rated 85 °C for power connection. Tighten the grounding screw with 8.8-13.2 inch-lbs. Use with Copper Conductors Only. Utilisez un fil de 18AWG-12AWG évalué à 85 °C pour le raccordement électrique. Serrer la vis de mise à la terre à 8.8-13.2 inch-lbs. Utiliser uniquement avec des conducteurs en cuivre. Grounding Screw Alarm Relay Connecting The alarm relay output contacts have a current carrying capacity of 30 VDC. Contact 1A is a 2 pin terminal block that attaches to the NT328G’s ALM port. The alarm relay contact is a “Normally open” contact that will close when it detects any power failures. ALM Port External Power Alarm System System Note: Use 24 AWG wire rated 85 °C for connection. Tighten the screw with 8.8-13.2 inch-lb. Note: Utilisez un fil de calibre 24 AWG à 85 °C pour la connexion. Serrer la vis à 8.8 - 13.2 inch-lb. NT328G Industrial Ethernet 18 Managed Switch Series

Drawing No. LP1108 Chapter 2 Installation Revision A Power Connections Power Connections Terminal Block Connector The switch can be powered from two UL61010-2-201 certified SELV power supplies (input range 100 V-240 V). The AC power connector is a 3P terminal block; “L” stands for Line and “N” stands for Neutral. Tighten the wire-clamp screws with Torque Value 1.7 inch-lbs to prevent the wires from being loosened. After completing chassis installation, apply power to the fused power distribution panel feeding the chassis. Use an Overcurrent Protection device (circuit breaker) rated 20 A at mains power supply circuit. Note: The AC power should be connected to a well-fused power supply. Use 18AWG-12AWG wire rated 85 °C for power connection. Tighten the screw with 8.8-13.2 inch-lbs. Note: L’alimentation en courant alternatif doit être connectée à une alimentation bien protégée. Utilisez un fil de 18AWG-12AWG évalué à 85 °C pour le raccordement électrique. Serrer la vis à 8.8-13.2 inch-lbs. WARNING: Ensure that all power sources to the chassis (power distribution panel) are turned off during the connection. AVERTISSEMENT: Assurez-vous que toutes les sources d’alimentation du châssis (panneau de distribution d’alimentation) sont étein-. Connecting to the Ethernet Port (RJ45 Ethernet) The switch provides two types of electrical (RJ45) and optical (mini-GBIC) ports. To connect the Ethernet port via RJ45: ● To connect to a PC, use a straight-through or a cross-over Ethernet cable. ● To connect the switch to an Ethernet device, use UTP (Unshielded Twisted Pair) or STP (Shielded Twisted Pair) Ethernet cables. Connecting to the Ethernet Port (Fiber, SFP/SFP+) For available 100 or 1000 Mbps fiber ports, use the SFP LC style connectors. For available 10 Gbps ports (ports 25 - 28 only), use the SFP+ LC style connectors. The connectors are available with multimode or singlemode transceivers. The Optical Transceiver must use a UL Certificated Class 1 laser product that shall comply with CDRH 21CFR 1040.10 and 1040.11.DANGER: Never attempt to view optical connectors that might be emitting laser energy. Do not power up the laser product without connecting the laser to the optical fiber and putting the cover in position, as the laser ouputs will emit infrared light. AVERTISSEMENT: Ne tentez jamais de voir des connecteurs optiques qui émettent de l’énergie laser. N’allumez pas le produit laser sans connecter le laser à la fibre optique et en plaçant le couvercle en position, car les sorties laser émettront la lumière laser infrarouge.

NT328G Industrial Ethernet Managed Switch Series 19

Chapter 2 Installation Drawing No. LP1108 LED Status Indications Revision A LED Status Indications LED NAME INDICATOR/COLOR CONDITION SYSTEM STATUS INDICATORS On/Green System is working normally SYS Flashing/Green System booting, or database saving or remote download is in-progress Off System is not working or does not have power P1 On/Green P1 power line has power Off P1 power line is disconnected or does not have power P2 On/Green P2 power line has power Off P2 power line is disconnected or does not have power Alarm On/Red Alarm event Off No alarm RR (Ring Role) On/Green One of 3 Ring groups is enabled and is in the Master role Off Ring is in the slave role RS (Ring Status) On/Green Ring failure occurs and is detected Off No ring failure detected PORT STATUS INDICATORS RJ45 Port Link/Act NT328G Industrial Ethernet Managed Switch Series On/Green Ethernet link is up but no traffic is detected Flashing/Green Ethernet link is up and there is traffic detected Off Ethernet link is down RJ45 Port Speed On/Yellow A 1000 Mbps connection is detected Off No link detected or a 10 Mbps, 100 Mbps connection is detected SFP Port Link (Port 9 to 24) (NT328G-20SFP) On/Green Ethernet link is up Flashing/Green Ethernet link is up and there is traffic detected Off Ethernet link is down SFP Speed (100/1000M) (Port 9 to 24) (NT328G-20SFP) On/Yellow SFP port speed is 1000 Mbps Off SFP port speed is 100 Mbps or link down SFP+ (10G) Port Link (Port 25 to 28) On/Green Ethernet link is up Flashing/Green Ethernet link is up and there is traffic Off Ethernet link is down SFP+ (10G) Speed (Port 25 to 28) On/Yellow Off SFP port speed is 10 Gbps SFP port speed is 1 Gbps or link down 20

Drawing No. LP1108 Chapter 2 Installation Revision A Console Connection Console Connection The Console port is used for local management through a terminal emulator or a computer with terminal emulation software. Console port specifications are as follows: • DB9 connector to connect to computer COM port • Baud rate: 115200 bps • 8 data bits, 1 stop bit • Parity: None • Flow Control: None To connect the host PC to the console port, a RJ45 (male) connector to RS232 DB9 (female) connector cable is required. The RJ45 cable is connected to the CID port of the switch. The DB9 cable is connected to the PC COM port. The pin assignment of the console cable is shown below: Connect & Login to the Switch 1. Connect to the switch Ethernet port (RJ45 Ethernet port). 2. Factory default IP: 192.168.1.201/24 3. Login with default user name and password. User name: admin Password: admin CLI Initialization & Configuration (Optional) 1. Connect to the switch Ethernet port (RJ45 Ethernet port). 2. Key-in the command under Telnet: telnet 192.168.1.201 3. Login with default user name and password. User name: admin Password: admin 4. Change the IP with commands listed below. CLI Command enable configure interface vlan 1 ip-address xxx.xxx.xxx.xxx netmask xxx.xxx.xxx.xxx exit

NT328G Industrial Ethernet Managed Switch Series Console Port 21

Chapter 2 Installation Drawing No. LP1108 Web Interface Initialization (Optional) Revision A Web Interface Initialization (Optional) Web Browser Support If Internet Explorer 7 (or newer version) is used, the following settings are recommended: PARAMETER SETTING Language Script Latin Based Web Page Font Times New Roman Plain Text Font Courier New Encoding Unicode (UTF-8) Text Size Medium If Firefox is used, the following settings are recommended: PARAMETER SETTING Web Page Font Times New Roman Encoding Unicode (UTF-8) Text Size 16 If Google Chrome is used, the following settings are recommended: PARAMETER SETTING Web Page Font Times New Roman Encoding Unicode (UTF-8) Text Size Medium System Reset The reset button is provided to reboot the system without the need to remove power. If the switch is unresponsive, the user may need to push the reset button. Reset Button NT328G Industrial Ethernet

22 Managed Switch Series

Drawing No. LP1108 Chapter 2 Installation Revision A Ordering Information Ordering Information PART NUMBER DESCRIPTION NT328G-04SFP-AC1 28-port; Managed L3 Industrial Ethernet Switch (24 10/100/1000BaseT RJ45 ports; 4 Dual Mode (1000/10GBase) SFP expansion slots); one 100-240 VAC power input NT328G-04SFP-AC2 28-port; Managed L3 Industrial Ethernet Switch (24 10/100/1000BaseT RJ45 ports; 4 Dual Mode (1000/10GBase) SFP expansion slots); two 100-240 VAC power inputs NT328G-20SFP-AC1 28-port; Managed L3 Industrial Ethernet Switch (8 10/100/1000BaseT RJ45 ports; 20 Dual Mode (16 100/1000Base; 4 1000/10GBase) SFP expansion slots); one 100-240 VAC power input NT328G-20SFP-AC2 28-port; Managed L3 Industrial Ethernet Switch (8 10/100/1000BaseT RJ45 ports; 20 Dual Mode (16 100/1000Base; 4 1000/10GBase) SFP expansion slots); two 100-240 VAC power inputs Accessories PART NUMBER DESCRIPTION NTSFP-FX 100BaseFX multimode fiber SFP pluggable transceiver (LC style connector, 2km) NTSFP-FXE-YY 100BaseFX singlemode fiber SFP pluggable transceiver (LC style connector) NTSFP-TX 1000BaseT copper SFP pluggable transceiver NTSFP-SX 1000BaseSX multimode fiber SFP pluggable transceiver (LC style connector, 550m) NTSFP-LX-ZZ 1000BaseLX singlemode fiber SFP pluggable transceiver (LC style connector) NT10GSFP-SR 10GBase multimode fiber SFP+ pluggable transceiver (LC style connector, 300m) NT10GSFP-LR-ZZ 10GBase singlemode fiber SFP+ pluggable transceiver (LC style connector) NT328G-AC-US US Industrial High-Temp Power Cord Assembly for use with the NT328G (Cord Length: 7 Ft., Gauge/Conductor: 18/3, Temp. Rating: 105°C, Plug: NEMA 5-15, Voltage Rating: 300V) Where: YY = 15, 40, or 80 for FX singlemode; ZZ = 10, 40, or 80 for singlemode. NT328G Industrial Ethernet Managed Switch Series 23

Chapter 2 Installation Drawing No. LP1108 Accessories Revision A NT328G Industrial Ethernet

24 Managed Switch Series

Drawing No. LP1108 Service and Support Information Revision A Service Information Service and Support Information Service Information We sincerely hope that you never experience a problem with any of our products. If you do need service, call Red Lion at 1-877-432-9908 for Technical Support. A trained specialist will help you determine the source of the problem. Many problems are easily resolved with a single phone call. If it is necessary to return a unit to us, an RO (Repair Order) can be obtained on the Red Lion website. Red Lion tracks the flow of returned material with our RO system to ensure speedy service. You must include this RO number on the outside of the box so that your return can be processed immediately. Be sure to have your original purchase order number and date purchased available. We suggest that you give us a repair purchase order number in case the repair is not covered under our warranty. You will not be billed if the repair is covered under warranty. Please supply us with as many details about the problem as you can. The information you supply will be written on the RO form and supplied to the repair department before your unit arrives. This helps us to provide you with the best service, in the fastest manner. Repairs are completed as soon as possible. If you need a quicker turnaround, ship the unit to us by air freight. We give priority service to equipment that arrives by overnight delivery. We apologize for any inconvenience that the need for repair may cause you. We hope that our rapid service meets your needs. If you have any suggestions to help us improve our service, please give us a call. We appreciate your ideas and will respond to them. For Your Convenience: Please fill in the following and keep this manual with your Red Lion system for future reference. P.O. #: Date Purchased: Purchased From: Serial Number: Product Support

Technical Support: Inside US: +1 (877) 432-9908 Outside US: +1 (717) 767-6511 Support: support.redlion.net Hours: 8:00 am to 6:00 pm EST NT328G Industrial Ethernet Managed Switch Series Red Lion Controls 20 Willow Springs Circle York, PA 17406 Website: http://www.redlion.net 25

Service and Support Information Drawing No. LP1108 Product Support Revision A LIMITED WARRANTY (a) Red Lion Controls Inc. (the “Company”) warrants that all Products shall be free from defects in material and workmanship under normal use for the period of time provided in “Statement of Warranty Periods” (available at http://www.redlion.net) current at the time of shipment of the Products (the “Warranty Period”). EXCEPT FOR THE ABOVE-STATED WARRANTY, COMPANY MAKES NO WARRANTY WHATSOEVER WITH RESPECT TO THE PRODUCTS, INCLUDING ANY (A) WARRANTY OF MERCHANTABILITY; (B) WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE; OR (C) WARRANTY AGAINST INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS OF A THIRD PARTY; WHETHER EXPRESS OR IMPLIED BY LAW, COURSE OF DEALING, COURSE OF PERFORMANCE, USAGE OF TRADE OR OTHERWISE. Customer shall be responsible for determining that a Product is suitable for Customer’s use and that such use complies with any applicable local, state or federal law. (b) The Company shall not be liable for a breach of the warranty set forth in paragraph (a) if (i) the defect is a result of Customer’s failure to store, install, commission or maintain the Product according to specifications; (ii) Customer alters or repairs such Product without the prior written consent of Company. (c) Subject to paragraph (b), with respect to any such Product during the Warranty Period, Company shall, in its sole discretion, either (i) repair or replace the Product; or (ii) credit or refund the price of Product provided that, if Company so requests, Customer shall, at Company’s expense, return such Product to Company. (d) THE REMEDIES SET FORTH IN PARAGRAPH (c) SHALL BE THE CUSTOMER’S SOLE AND EXCLUSIVE REMEDY AND COMPANY’S ENTIRE LIABILITY FOR ANY BREACH OF THE LIMITED WARRANTY SET FORTH IN PARAGRAPH (a). NT328G Industrial Ethernet

26 Managed Switch Series