PDF Content Summary: RD7100® Electromagnetic and RF Marker locator Operation Manual 90/RD7100-MARKER-OPMAN-EN/01

Table of Contents Section 1 - Preface ....................................... 2 Section 2 - Introduction ............................... 5 2.1 About this manual ........................................ 5 2.2 About the RD7100 ....................................... 5 2.3 Extended warranty ....................................... 5 2.4 Manual outline ............................................. 5 2.5 Safety .......................................................... 5 2.6 Training ....................................................... 6 Section 3 - System overview ....................... 7 3.1 RD7100 locator ............................................ 8 3.2 Tx-1, Tx-5 and Tx-10 transmitters .............. 10 3.3 Using the menu.......................................... 10 Section 4 - Operation ................................. 12 4.1 First use ..................................................... 12 4.2 Power on / off ............................................ 15 4.3 Keypad actions & shortcuts ....................... 15 4.4 Antenna modes.......................................... 16 4.5 System setup ............................................. 16 4.6 Dynamic Overload ProtectionTM ................. 17 Overload warning ............................................ 18 4.7 TruDepthTM measurement ......................... 18 4.8 StrikeAlertTM ................................................ 18 4.9 Backlight .................................................... 18 Bluetooth wireless ........................................... 18 4.10 SideStepautoTM ......................................... 18 4.11 Transmitter power output ......................... 19 4.12 Transmitter Eco mode .............................. 19 4.13 Measure mode ......................................... 19 4.14 CALSafeTM ............................................... 20 4.15 Usage-Logging ........................................ 20 Section 5 - Locating cables and pipes ..... 21 5.1 Frequencies ............................................... 21 5.2 Choice of frequency for active location ...... 22 5.3 Antenna modes.......................................... 22 5.4 Compass ................................................... 24 5.5 Trace ......................................................... 24 5.6 Pinpoint ..................................................... 24 5.7 Sweep and search ..................................... 25 Section 6 - Locating RF Markers .............. 26 6.1 Marker Mode ............................................. 26 6.2 Locating RF markers ................................. 27 Section 7 - Depth and current readings ... 28 7.1 TruDepthTM ................................................ 28 7.2 Verifying depth measurements .................. 29 7.3 Current readings ........................................ 29 Section 8 - Locating techniques ............... 32 8.1 Identifying target utilities ............................ 32 8.2 Signal & ground connection ....................... 33 8.3 Double-ended connections ........................ 33 Section 9 - Fault-finding ........................... 34 9.1 About fault-finding ..................................... 34 9.2 Preparation ............................................... 34 9.3 How to find a fault ..................................... 35 Section 10 - Survey Measurements ......... 36 10.1 Saving measurements ............................. 36 Section 11 - Bluetooth wireless connections ............................................... 37 11.1 Switching Bluetooth On ........................... 37 11.2 Switching Bluetooth off ............................ 37 11.3 Pairing to an Android, PDA or PC ............ 37 11.4 Bluetooth Protocol ................................... 38 11.5 Bluetooth standby mode .......................... 38 11.6 Troubleshooting ...................................... 38 Section 12 - Using accessories ................ 40 12.1 About accessories ................................... 40 12.2 Headphones ............................................ 40 12.3 Locator clamps ........................................ 40 12.4 Transmitter clamps .................................. 41 12.5 Sondes .................................................... 42 12.6 Stethoscopes .......................................... 43 12.7 Submersible antenna .............................. 44 12.8 Phone/Tablet mount ................................ 45 Section 13 - Appendices ........................... 47 13.1 Care and maintenance ............................ 47 13.2 Enhanced Self-Test ................................. 47 13.3 RD ManagerTM ........................................ 48 13.4 Upgrading software ................................. 48 13.5 eCert ....................................................... 48 13.6 Time and date error messages ................ 48 13.7 RF Markers .......................................... 48 13.8 Supported Accessories ........................... 49

© 2019 Radiodetection Ltd 1

Section 1 - Preface Before you begin Thank you for your interest in Radiodetection’s RD7100® cable, pipe and RF marker locator. Please read this user manual in its entirety before attempting to use the RD7100 system. Radiodetection products, including this manual, are under continuous development. The information contained within is accurate at time of publication; however the RD7100, this manual and all its contents are subject to change. Radiodetection Limited reserves the right to modify the product without notice and some product changes may have taken place after this user manual was published. Contact your local Radiodetection dealer or visit radiodetection.com for the latest information about the RD7100 product family, including this manual. Important notices General The performance of any cable and pipe locator may be affected when used in close proximity to ferrous materials such as manhole covers, steel-toe boots and nearby vehicles. Keep a distance of one or two meters from these objects when taking critical measurements such as depth and current readings. This instrument, or family of instruments, will not be permanently damaged by reasonable electrostatic discharge and has been tested in accordance with IEC 801-2. However, in extreme cases temporary malfunction may occur. If this happens, switch off, wait and switch on again. If the instrument still malfunctions, disconnect the batteries for a few seconds. Safety WARNING! Failure to comply with safety warnings can cause serious injury or death CAUTION!: Failure to comply with safety cautions can result in damage to equipment or property This equipment shall be used only by qualified and trained personnel, and only after fully reading this Operation Manual. WARNING! Direct connection to live conductors is POTENTIALLY LETHAL. Direct connections to live conductors should be attempted by fully qualified personnel only using the relevant products that allow connections to energized lines. WARNING! The transmitter is capable of outputting potentially lethal voltages. Take care when applying signals to any pipe or cable and be sure to notify other technicians who may be working on the line. WARNING! Reduce audio level before using headphones to avoid damaging your hearing. WARNING! This equipment is NOT approved for use in areas where hazardous gases may be present. WARNING! Before removing the transmitter battery pack, switch off the unit and disconnect all cables WARNING! The RD7100 locator will detect most buried conductors but there are some objects, including live objects, which do not radiate any detectable signal. The RD7100, or any other electromagnetic locator, cannot detect these objects so proceed with caution. There are also some live cables which the RD7100 will not be able to detect in Power mode. The RD7100 does not indicate whether a signal is from a single cable or from several in close proximity. CAUTION: The battery cover, the accessory cover and the headphone cover protect the locator’s sockets from debris and water ingress. If they get damaged or lost, contact Radiodetection or your local service representative for a replacement one. Batteries WARNING! Only use charging equipment provided by Radiodetection. The use of alternative chargers may cause a safety hazard and/or reduce the life of the battery. CAUTION: Do not let your battery completely discharge as this may reduce its life or damage it permanently. If you are not using your equipment for a long period do charge them at least once a month. If you have left your equipment stored for longer than 1 month period and fully discharged the battery, ensure that the battery charger indicates that it is working properly, as for its instructions, and that the battery does not overheat. WARNING! Batteries can get hot after prolonged use at full output power. Take care while replacing or handling batteries. WARNING! Do not tamper with, or attempt to disassemble the battery packs. CAUTION: If battery failure is suspected or if the battery shows any sign of discoloration / physical damage return the entire unit to an authorized repair center for investigation and repair. Local, national or IATA transport regulations may restrict the shipment of faulty batteries. Check with your courier for restrictions and best practice guidelines. Your local Radiodetection

© 2019 Radiodetection Ltd 2

representative will be able to direct you to our authorized repair centers. Disposal This symbol on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) must not be treated as domestic waste, but must be disposed of professionally. It is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your disposal service or product supplier. Please dispose of this device in a manner appropriate to the relevant legal requirements at the end of its product life Batteries should be disposed of in accordance with your company’s work practice, and / or the relevant laws or guidelines in your country or municipality. Special Bluetooth® notice RD7100 cable, pipe and RF Marker locators and transmitters contain a Class 1 Bluetooth device that can emit radio frequency energy during the operation of certain product features. While the Bluetooth device is busy, pairing or sending survey measurements to a paired device, always ensure a minimum separation of 200mm (8 inches) between the Bluetooth antenna and your body. The location of the antenna is shown in Section 3, figure 3.1. Compliance The Declaration of conformity is available to download from the RD7100 cable, pipe and RF marker product section page in radiodetection.com/ EU Compliance This equipment complies with the following EU Directives: • Radio Equipment Directive – 2014/53/EU • Low Voltage Directive – 2014/35/EU • EMC Directive – 2014/30/EU • RoHS – Restriction of Hazardous Substances – Directive – 2011/65/EU FCC Compliance Statement This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • The equipment may not cause harmful interference. • The equipment must accept any interference received, including interference that may cause undesired operation. This equipment has been/ tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense. Modifications: Any modifications made to this equipment not approved by Radiodetection may void the authority granted to the user by the FCC to operate this equipment. Industry Canada Compliance Statements ICES-003 Class A Notice: This Class A digital apparatus complies with Canadian ICES-003. Avis NMB-003, Classe A: Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada Environmental WEEE, ROHS Manufacturing ISO 9001:2015

© 2019 Radiodetection Ltd 3 Intellectual property © 2019 Radiodetection Ltd. All rights reserved. Radiodetection is a subsidiary of SPX Corporation.. Radiodetection and RD7100 are registered trademarks of Radiodetection in the United States and/or other countries. Trademarks and Notices. The following are trademarks of Radiodetection: eCert, TruDepth, SideStep, SideStepauto, Power Filters, RD Manager, RD Map, Peak+, SurveyCERT, StrikeAlert, CALSafe. The design of the RD7100 locators and transmitters has been registered. The design of the 4 chevrons has been registered. The Bluetooth word, mark and logos are registered trademarks of Bluetooth Sig, Inc. and any use of such trademarks by Radiodetection is under license. RAM is a trademark of National Products Inc . Windows is a registered trademarks of Microsoft Corporation in the United States and / or other countries. Google is a registered trademarks of Google LLC. Due to a policy of continued development, we reserve the right to alter or amend any published specification without notice. This document may not be copied, reproduced, transmitted, modified or used, in whole or in part, without the prior written consent of Radiodetection Ltd © 2019 Radiodetection Ltd 4

Section 2 - Introduction 2.1 About this manual This manual provides underground utilities survey professionals with comprehensive operating instructions for the RD7100 locator and transmitter system. Before operating the RD7100 system it is very important that you read this manual, noting all safety warnings and procedures. Additional documentation The full product specification, RD Manager, RD Map and SurveyCERT+ manuals are available to download from radiodetection.com. 2.2 About the RD7100 The RD7100 product family offers a comprehensive range of locators and transmitters designed to meet specific customer needs. The RD7100 locator is ergonomically designed to provide the operator with a balanced, light weight tool that encourages extended use in most environments. A wide range of accessories are available to enhance the performance and to add extra functionality. For more information about the Precision Locate Accessories Range, visit radiodetection.com/accessories 2.3 Extended warranty RD7100 locators and transmitters are covered by a 1 year warranty as standard. Users can extend the warranty period to a total of 3 years by registering their products (locators and transmitters) within 3 months from purchase. There are 2 ways to register your product: 1. Radiodetection portal Visit portal.radiodetection.com to create your portal account* and use the Product page to register your locator or transmitter. Visit support.radiodetection.com for instructions on how to create a portal account or register your product. * A valid e-mail address and mobile number are required. 2. Windows Applications RD Manager, available from radiodetection.com/RDManager From time to time Radiodetection may release new software to improve the performance or add new functionality to products. By registering the user will have the option of subscribing to e-mail alerts advising about any new software and special offers related to its product range. Users can opt out any time from receiving software and technical notifications or just from receiving marketing material. 2.4 Manual outline Section 1 includes an overview of safety procedures and notices. Review them before moving on to Section 2 and the rest of this manual Section 3 provides an overview of the RD7100 system with annotated diagrams of the locator and transmitter Section 4 introduces basic setup and operation using the RD7100 locator’s menu system. Section 5 introduces the theory and practice of cable and pipe location using the RD7100 locator and transmitter. Section 6 provides instructions on how to use the RD7100 to locate RF markers Section 7 introduces depth and current readings. Section 8 provides general locating tips. Section 9 introduces cable sheath fault-finding using the RD7100 locator and an accessory A-frame. Section 10 introduces the survey measurement capabilities of the locator. Section 11 provides instructions on how to use the RD7100 locator’s Bluetooth technology to pair to external devices Section 12 introduces the range of accessories that are compatible with the RD7100 system Section 13 includes several appendices with reference material and other technical information. 2.5 Safety Read this manual in its entirety before attempting to operate the RD7100 locator or transmitter. Note all safety notices in the preface and throughout this manual You are responsible for determining whether the conditions are suitable for using this device. Always carry out a risk assessment of the site to be inspected Follow your company and national safety procedures and or requirements when operating this equipment in any environment or workplace. If you are unsure what policies or procedures apply, contact your company or

© 2019 Radiodetection Ltd 5

site’s occupational health and safety officer or your local government for more information. Do not use this equipment if you suspect that any component or accessory is damaged or faulty. Before inserting the earth stake into the ground, ensure there are no shallow cables or services that could be damaged by the earth stake Use authorized accessories only. Incompatible accessories may damage the equipment or give inaccurate readings. If you intend to uncover a sub-surface utility by digging, you must follow your company, region and country’s codes of practice for excavation. Do not use Bluetooth in areas where wireless communication devices are considered hazardous. Check with local authorities for more information. Keep this equipment clean and arrange for regular services with an authorized Radiodetection service center. More information can be found in the Appendix or from your local Radiodetection representative. It is important to regularly clean and sanitize products which may become contaminated through contact with foul water or other contaminants Headphone use: you need to remain alert to traffic and other hazards that are normally heard outdoors. Always turn the volume down before plugging headphones into an audio source and use only the minimum level, necessary to take your measurements. Excessive exposure to loud sounds can cause hearing damage. Do not attempt to open or dismantle any part of this equipment unless directed specifically by this manual. Doing so may render the equipment faulty and may void the manufacturer’s warranty. You are responsible for determining whether you consider the measurement results to be valid and for any conclusions that are reached or any measures that are taken as a result thereof. Radiodetection can neither guarantee the validity of any measuring results nor can we accept liability for any such results. We are on no account able to accept liability for any damage which may be caused as a consequence of the use of these results. Please see the Standard Warranty Terms enclosed with the product for further information. 2.6 Training Radiodetection provides training services for most Radiodetection products. Our qualified instructors will train equipment operators or other personnel at your preferred location or at Radiodetection headquarters. For more information go to radiodetection.com or contact your local Radiodetection representative.

© 2019 Radiodetection Ltd 6 Section 3 - System overview © 2019 Radiodetection Ltd 7 1

3 5 7 18 16 17 20 19 2 6 29 28

Figure 3.1: RD7100 cable, pipe and marker locator 21

33 22 31 23 24 24 32 32 4 8 25 25 25 31 31 31 10 26 26 26 26 9 27 27 27 27 27 11 30 12 12 13 13 14 15 15 15 Locator screen icons 16 Battery icon: Indicates the battery level 3.1 RD7100 locator 17 Gain and Log number: Displays the log number momentarily after a survey measurement is saved to memory 18 Volume icon: Displays the volume level 19 Radio Mode: Indicates when Radio Mode is active 20 Power Mode: Indicates when Power Mode is active 21 Accessory indicator: Indicates when an accessory is connected 22 A-Frame icon: Indicates when the A-Frame is connected 23 Frequency / marker type / current / menu readout 24 Compass/ Marker mode indicator: Shows the direction of the located cable relative to the locator. Also used as a graphical indication for Marker mode active 25 Bluetooth icon: Indicates status of Bluetooth connection. Flashing icon means pairing is in progress. Solid icon indicates an established connection is active 26 Antenna mode icon: Indicates antenna selection: Peak, Null, Broad Peak, Peak+ and Guidance Mode 27 Current / depth indicator 28 Sonde icon: Indicates that the signal source is from a sonde 29 Line icon: Indicates that the signal source is from a line 30 Indicates the signal strength and Peak marker 31 Peak / Proportional arrows: Indicates the location of the line relative to the locator 32 Signal strength: Numerical indication of signal strength Locator features 1 Bluetooth module antenna 2 Keypad 3 LCD with auto backlight 4 Battery and USB connector (inside the battery compartment) 5 Battery charging connector (Li-Ion pack) 6 Headphone connector 7 Accessory connector 8 Marker loop antenna 9 Speaker Locator keypad 10 Power key : Switches the unit on and off. Opens the locator menu 11 Frequency key : Selects frequency. Closes submenu 12 Up and down arrows : Adjusts the locator signal gain. Scrolls through the menu options 13 Antenna key : With antenna folded up toggles Peak, Peak+, Null, Broad Peak and Guidance modes. With antenna folded up toggles marker and combined (marker/ line) modes. Opens a submenu 14 Survey key : Sends survey measurements to a paired device 15 Transmitter key : Not used

33 Fault Find arrows © 2019 Radiodetection Ltd 8 © 2019 Radiodetection Ltd 9 Figure 3.2 Tx Transmitter

3.2 Tx-1, Tx-5 and Tx-10 transmitters Transmitter features 1 Keypad 2 LCD 3 Removable accessory tray 4 D-cells battery holder 5 Optional Lithium-Ion rechargeable battery pack 6 Bluetooth module antenna (model dependent) Transmitter keypad 7 Power key : Switches the unit on and off. Opens the transmitter menu 8 Frequency key : Selects frequency. Menu navigation key 9 Up and down arrows : Adjusts the output signal level. Scrolls through the menu options 10 Measure key : Used to take voltage and impedance measurements. Opens a sub menu. Transmitter screen icons 11 Battery icon: Indicates the battery level 12 Alphanumeric description of selected operation mode 13 Standby icon: Appears when the transmitter is in Standby Mode 14 Output level: Displays transmitter output power 15 Accessory or Measurement indicators: Indicates if an accessory is connected or if measure mode is active 16 DC icon: Appears when the transmitter is powered from a DC source 17 Induction indicator: Appears when the transmitter is in Induction Mode 18 A-Frame (Tx-5 or Tx-10 only): Indicates when the transmitter is in Fault-Find Mode 19 CD Mode indicator (Tx-10 only): Indicates that the transmitter is in Current Direction Mode – Not operational with a RD7100 locator 20 Voltage warning indicator: Indicates that the transmitter is outputting potentially hazardous voltage levels 21 Volume icon: Displays the volume level 3.3 Using the menu The RD7100 locator and transmitter menus allow you to select or change system options. Once entered, the menu is navigated using the arrow keys. Navigation is consistent on both the transmitter and the locator. In the menu the options will appear in the bottom left-hand corner of the display. Note that when browsing the locator menu, the and keys act as left and right arrows. When browsing the transmitter menu the and keys act as left and right arrows. The right arrow enters a submenu and the left arrow selects the option and returns to the previous menu. Navigating the locator menu 1 Press the key to enter the menu 2 Use the or keys to scroll through the menu options 3 Press the key to enter the option's submenu 4 Use the or arrows to scroll through the submenu options 5 Press the key to make a selection and return to the previous menu 6 Press the key to return to the main operation screen Locator menu options VOL Adjust the speaker volume from 0 (mute) to 3 (loudest) BT Enable, disable, reset or pair Bluetooth connections. Also defines the protocol used when connecting to a compatible device UNITS Select metric or imperial units INFO Run a Self-Test, display the date of the most recent service recalibration (M CAL) or the most recent eCert calibration Figure 3.3 Tx-1, Tx-5 and Tx-10 signal transmitters

© 2019 Radiodetection Ltd 10

Transmitter menu options VOL Adjust the speaker volume from 0 (mute) to 3 (loudest) FREQ Enable or disable individual frequencies BOOST Boost transmitter output for a specified period of time (in minutes) LANG Select menu language OPT F Run SideStepautoTM to auto-select a locate frequency for the connected utility BATT Set battery type: Alkaline, NiMH or Li- Ion. Select Eco mode (alkaline batteries only) MAX P Set the transmitter to output its maximum wattage. MODEL Match the transmitter setting to the model of your locator MAX V Set the output voltage to maximum (90V) BT Enable, disable or pair Bluetooth connections (Bluetooth models only) Table 3.2 Transmitter menu options CAL Displays the date of the last calibration or eCert calibration validation MARKR Enable or disable the marker locator or individual utility markers LANG Select menu language POWER Select local power network frequency: 50 or 60Hz ANT Enable or disable antenna modes with the exception of Peak FREQ Enable or disable individual frequencies ALERT Enable or disable StrikeAlert BATT Set battery type: Alkaline, NiMH or Li-Ion ARROW Select NULL or proportional Guidance (GUIDE) arrows in Peak+ mode COMP Enable or disable display of the Compass feature. Table 3.1 Locator menu options Navigating the transmitter menu 1 Press the key to enter the menu 2 Use the or keys to scroll through the menu options 3 Press the key to enter the option’s submenu. 4 Use the or keys to scroll through the submenu options 5 Press the key to confirm selection and return to the previous level or exit the menu 6 Press the key to return to the main operation screen

© 2019 Radiodetection Ltd 11

Section 4 - Operation 4.1 First use Power options RD7100 Cable, Pipe and RF marker locators are shipped with the Lithium-ion battery packs disconnected. The transmitter D-cells and optional Li-ion battery pack are packed separately. The locator can also be powered using D-cell alkaline or good quality NiMH batteries. The transmitter can also be powered using NiMH D-cells batteries or by the optional transmitter Li-Ion rechargeable battery pack It’s important to set the correct battery chemistry in the locator to optimize performance, see Section 4.5 Transmitters can also be powered using optional accessory mains or vehicle power adapters. On the Locator: To connect the Li-ion battery pack unlatch the battery compartment Figure 4.1 Opening the battery compartment and plug the battery lead into the battery connector. Figure 4.2 Li-ion battery pack connection NOTE: Fully charge your lithium-ion battery pack before its first use On the transmitter: To fit the D-cell batteries in the transmitter, unlatch the accessory tray. The battery compartment (see figure 3.2) is located underneath the transmitter body. Use the turnkey to unlatch the battery compartment. Insert eight D-Cell Alkaline or NiMH batteries. Figure 4.3 D-cell battery trays Battery status The locator and transmitter displays provide a battery level indicator (refer to the diagrams in Section 3. When battery replacement is necessary, the display shows a flashing battery icon. Locator battery pack: catch (figure 4.1) Figure 4.4 Press the retaining latch inwards

NOTE: Prolonged use of high power output on the transmitter will reduce battery life. Removing / fitting battery packs 1 Open the battery compartment using the release 2 If using a Li-Ion battery pack un-plug the lead connector (see figure 4.2) 3 Lift the accessory cover slightly and press the battery retaining latch inwards © 2019 Radiodetection Ltd 12

4 Rotate the battery pack away and up from the latch 5 Repeat on the other side to release the battery pack completely then lift the battery pack away Figure 4.5 Repeat then lift the battery pack away To fit a new battery, lift both accessory covers slightly, then gently push the replacement pack into place until it clicks on both sides, then close the battery pack Figure 4.6 installing a new battery pack Using the D-cell locator battery holder The locator can also be powered by three D-Cell Alkaline or NiMH batteries. NOTE: When installing batteries always observe the correct battery polarity as indicated on the battery tray. Figure 4.7 Locator D-cell holder 1 Open the cell tray and insert 1 D-cell 2 Close the tray and insert 2 D-cells Transmitter battery pack: 1 Unlatch then remove the accessory tray

To insert the D-cells: Figure 4.8 Release then remove the accessory tray 2 Turn the release catch, then open the battery compartment (fig 4.9) © 2019 Radiodetection Ltd 13

Charging the battery packs WARNING! Only use charging equipment provided by Radiodetection. The use of alternative chargers may cause a safety hazard and/or reduce the life of the battery. CAUTION: Do not let your battery completely discharge as this may reduce its life or damage it permanently. If you are not using your equipment for a long period do charge them at least once a month. If you have left your equipment stored for longer than 1 month period and fully discharged the battery, ensure that the battery charger indicates that it is working properly, as for its instructions, and that the battery does not overheat. WARNING! Batteries can get hot after prolonged use at full output power. Take care while replacing or handling batteries. Figure 4.9: Opening the battery compartment 3 Release the retaining catch (fig 4.10) by pressing gently, then lift the battery pack away WARNING! Do not tamper with, or attempt to disassemble the battery packs. CAUTION: If battery failure is suspected or if the battery shows any sign of discoloration / physical damage return the entire unit to an authorized repair center for investigation and repair. Local, national or IATA transport regulations may restrict the shipment of faulty batteries. Check with your courier for restrictions and best practice guidelines. Your local Radiodetection representative will be able to direct you to our authorized repair centers. You can re-charge your batteries using the Radiodetection mains or automotive chargers. NOTE: The charging temperature range is 0 to 45 °C, 32 to 113°F. Do not attempt to recharge your batteries outside this temperature range. Locator Li-Ion battery pack Figure 4.10: Press the release catch and lift the battery pack away 4 Line up the battery pack clips with the corresponding recesses on the transmitter body and press into place (fig 4.11) To recharge the locator battery pack, connect the battery charger to the DC input connector on the front of the battery pack. Figure 4.12 Charging the locator Li-ion battery pack Figure 4.11: Line up the battery pack and press into position 5 Close the battery pack, turn the retaining latch and replace the accessory tray

© 2019 Radiodetection Ltd 14

Transmitter Li-ion battery pack To recharge the battery pack, remove the pack from the transmitter and connect the transmitter battery charger. Figure 4.13 Charging the transmitter Li-Ion battery pack For more information about recharging batteries refer to the instructions that came with your charger 4.2 Power on / off Switch the locator or transmitter on by pressing the key. To switch the locator or transmitter off, press and hold the key until the screen blanks off. folded down: toggles marker and combined (marker/ line) modes. Increase and decrease gain. RD7100 automatically sets gain to mid- point when pressed With the loop folded down only, affects the marker locator gain Rapidly increase and decrease gain steps in 1dB increments Send a survey measurement over Bluetooth if paired - - Not Used Table 4.1: Locator key actions Transmitter key actions NOTE: The locator will automatically power off after 5 minutes if no keys are pressed. 4.3 Keypad actions & shortcuts Locator key actions Key Short press Long press Enter the menu Switch power off Scroll through locate frequencies from low to high Key Short press Long press Enter the menu Switch power off Scroll through locate frequencies from low to high - - Take voltage and impedance measurements using selected frequency Take voltage and impedance measurements at a standardized frequency Take voltage and impedance measurements at a standardized frequency Take voltage and impedance measurements at a standardized frequency Take voltage and impedance measurements at a standardized frequency Adjusts the output signal Select standby / maximum standard power When using active frequencies: Toggle Peak, Peak+, Null and Guidance antenna modes. PLM Model: In Power Mode: scroll through Power FiltersTM for improved discrimination of parallel or strong power signals With the loop Table 4.2: Transmitter key actions NOTE: to scroll through frequencies from high to low, hold while pressing the button (applies to both locators and transmitters) In Peak+ antenna mode: In Peak+ antenna mode: Switch between Guidance and Null arrows Switch between Guidance and Null arrows Switch between Guidance and Null arrows

© 2019 Radiodetection Ltd 15 © 2019 Radiodetection Ltd 16

4.4 Antenna modes The RD7100 locator supports 6 cable, pipe and marker locate modes, each of which is designed for specific uses, depending on what task is being carried out. To scroll between locate modes, press the key. PEAK: For accurate locating, the Peak bargraph provides a visual readout of the signal strength. The Peak signal is found directly over the buried utility. PEAK+: Choose to combine the accuracy of the Peak bargraph with Null arrows, which can indicate the presence of distortion, or with proportional Guidance arrows for rapid line tracing – switch between them by pressing and holding the key. GUIDANCE: Proportional arrows and a ballistic directional ‘needle’ combine with audio left/right indication for rapidly tracing the general path of a buried utility. NULL: Provides a quick left/right indication of the path of a utility. As Null is susceptible to interference, it is best used in areas where no other utilities are present MARKER: Selected by lowering the antenna loop down, is used to locate a specific marker COMBINED MODE: Selected by lowering the antenna loop and by pressing the key, is used to locate a specific marker whilst tracing a buried utility. For more information on selecting and using the various antenna modes to assist with cable and pipe location, refer to Section 5. For more information about locating RF Markers refer to section 6. 4.5 System setup The RD7100 locator and transmitter settings can be accessed via the menu. Once in the menu it is possible to change settings according to your personal preferences and operating requirements. Some examples of setting changes are shown below. Refer to the locator and transmitter menu options (tables 3.1 and 3.2) for more information. NOTE: These procedures refer to both the transmitter and locator unless stated otherwise. Before changing settings, ensure the locator or transmitter is switched on by pressing the key for two seconds. Language The locator and transmitter support a number of languages. You can specify your preferred language using the menu system. To select your preferred menu language: 1 Press the key to enter the menu 2 Scroll to the LANG menu using the or keys 3 Press the key (on the locator) or the key (on the transmitter) to enter the LANG menu 4 Scroll through the language options using the or keys 5 Press the key to accept your selection and return to the main menu. 6 Press the key to return to the main operation screen. Battery type RD7100 locators and transmitters support Lithium-Ion, Alkaline or Nickel Metal Hydride batteries. You should set the Locator and transmitter battery type to match the currently installed type. This is to ensure optimal performance and correct battery level indication. Lithium-Ion batteries will automatically be detected by the locator To set your battery type: 1 Press the key to enter the menu 2 Scroll to the BATT menu using the or arrows 3 Press the key (on the locator) or the key (on the transmitter) to enter the BATT menu 4 Scroll through the battery options using the or keys. 5 Press the key to accept your selection and return to the main menu 6 Press the key to return to the main operation screen Power network frequency Select the correct frequency (50 or 60Hz) for your country or region’s power supply on your locator. To change power frequency on the locator: 1 Press the key to enter the menu 2 Scroll to the POWER menu using the or keys 3 Press the key to enter the POWER menu 4 Scroll through the power options using the or 5 Press the key to accept your selection and return to the main menu 6 Press the key to return to the main operation screen

keys

Measurement units The RD7100 locator allows you to work in Metric or Imperial (US customary) units. To select your preferred units: 1 Press the key to enter the menu 2 Scroll to the UNITS option using the or keys 3 Press the key to enter the UNIT menu 4 Scroll through the measurement options using the or keys to select METRE (for metric) or IMP (for imperial) units 5 Press the key to accept your selection and return to the main menu 6 Press the key to return to the main operation screen Enabling / disabling frequencies The locator and transmitter support a wide range of frequencies and there may be times when some of these frequencies are not used. It is possible to quickly enable or disable frequencies using the menu system. To enable or disable frequencies: 1 Press the key to enter the menu 2 Scroll to the FREQ menu using the or keys 3 Press the key (on the locator) or the key (on the transmitter) to enter the FREQ menu 4 Scroll through the frequency options using the or keys 5 Press the key (on the locator) or the key (on the transmitter) to enter the frequency 6 Scroll to OFF or ON using the or keys 7 Press the key to accept your selection and return to frequency menu. 8 If you wish to make any further changes follow steps 4 to 6. If you do not wish to make any further changes press the key twice to return to the main operation screen. Marker locator By default the marker locator is enabled or disabled by lowering or folding the marker loop antenna, item 8 in Section 3, figure 3.1 You can choose to disable or re-enable the marker locator function. To disable the marker locator: 1. Press the key to enter the menu 2. Scroll to the MARKR menu using the or keys 3. Press the key to enter the MARKR menu 4. Scroll to OFF or AUTO menu 5. Press the key to accept your selection and return to MARKR menu The marker locator can detect up to 9 different utility markers. If you wish you can enable or disabling them by using the menu system: To enable or disable utility markers: 1. Press the key to enter the menu 2. Scroll to the MARKR menu using the or keys 3. Press the key to enter the MARKR menu 4. Scroll to the AUTO menu and press the key 5. Scroll up or down to select a specific marker 6. Press the key 7. Scroll to OFF or ON menu 8. Press the key to accept your selection and return to markers menu if you wish to make any further changes follow steps 5 to 8. If you do not wish to make any further changes press the key twice to return to the main operation screen. Volume control The transmitter and locator feature an internal speaker to provide critical warnings and assist with cable and pipe location. To adjust audio level: WARNING! Muting audio on the locator will disable the StrikeAlert audio alarm. 1 Press the key to enter the menu 2 Scroll to the VOL menu the or arrows 3 Press the key (locator) or the key (transmitter) to enter the VOL menu 4 Scroll through the volume options using the or keys 5 Press the key to accept your selection and return to the main menu. 6 Press the key to return to the main operation screen. 4.6 Dynamic Overload ProtectionTM Dynamic Overload ProtectionTM (DOP) allows you to locate accurately in areas with high levels of

© 2019 Radiodetection Ltd 17

electromagnetic interference, such as sub-stations and beneath high-voltage transmission lines. DOP works by disregarding signal spikes that would otherwise overwhelm the RD7100 locator’s digital signal processor. DOP is an integrated feature of all RD7100 locators. No action is required by the user. Overload warning In cases of high levels of electromagnetic interference, the DOP will not be able to prevent the RD7100 from becoming overloaded. If the RD7100 becomes overloaded, users will be alerted by a flashing mode icon. Both the depth and current measurements will be disabled in the event of an overload. 4.7 TruDepthTM measurement All RD7100 locators use TruDepthTM to measure depth automatically when a good quality reading can be assured. NOTE: TruDepth only indicates a locate depth when • The locator is correctly oriented above the target line, cable or sonde. • The local signal conditions are assessed as be good enough to ensure an accurate reading To help you orientate the locator correctly, you can use the locator’s compass feature on the screen Depth readings are displayed according to your preferred units of measurement. For more information on measuring depth, refer to Section 7. 4.8 StrikeAlertTM StrikeAlert detects the possible presence of shallow utilities, and warns the operator with a series of flashing asterisks on the display and an audible alarm, characterized by a rapid warbling sound. StrikeAlert will activate in Power and Active locate modes. RD7100 locators are shipped with StrikeAlert enabled by default; this can be disabled by accessing the StrikeAlert (‘ALERT’) menu and setting StrikeAlert to OFF. StrikeAlert can also be disabled using the RD Manager PC software. Refer to the RD Manager operation manual for further information. WARNING! Muting audio on the locator will disable StrikeAlert Audio alarm. 4.9 Backlight The transmitter and locator feature a backlight to improve LCD visibility when required. The locator’s backlight is controlled by an ambient light sensor and does not require adjustment by the user. The transmitter’s LCD backlight is activated whenever you press a key. The backlight will automatically switch off after a few minutes. Bluetooth wireless All RD7100 locators feature a Bluetooth wireless module as standard, providing the ability to connect to compatible devices such PCs, laptops or handheld devices running a compatible application. Refer to Section 11 for further information about Bluetooth wireless connections and how to pair your devices. NOTE: The RD7100 locator wireless features may be subject to national and or local regulations. Consult your local authorities for more information. WARNING! Do not attempt any wireless connection in areas where such technology is considered hazardous. This may include: petrochemical facilities, medical facilities or around navigation equipment. 4.10 SideStepautoTM The transmitter can be used to recommend a general- purpose locate frequency for the intended locate task by measuring the impedance of the target cable or pipe. SideStepautoTM helps to improve locate accuracy by determining the best signal. SideStepauto can also help to prolong battery life. SideStepauto operates only in Direct Connection mode. Using SideStepauto To enable SideStepauto: Connect the transmitter to the target utility, then 1 Press the key to enter the menu 2 Scroll to the OPT F menu using the or keys 3 Press the key to enter the OPT F menu 4 Scroll through using the or keys until START is displayed 5 Press the key to start SideStepauto and exit the OPTF Menu 6 Press the key to exit the menu NOTE: SideStepauto has to be enabled for each Direct Connection using the START option. At any time the user may manually change the frequency using the key

© 2019 Radiodetection Ltd 18

When Eco mode is active and the power output has been reduced, the display alternates between ‘POWER‘ and the current output power level. The transmitter will emit three beeps every time the power is reduced. It will then continue emitting two beeps each minute whilst it operates at a reduced power level. To enable or disable Eco mode 1 Press the key to enter the menu 2 Scroll to the BATT menu using the or keys and enter it by pressing the key. 3 Scroll through the battery options using the or until ALK is displayed. Press the key. 4 Use the or until ECO is displayed and press 4.11 Transmitter power output The transmitter supports several power output modes to help you select the optimal settings for your requirements whilst helping to prolong battery life. Adjusting power output NOTE: On iLOC enabled models, you can adjust the transmitter’s power output remotely using the locator. For more information, refer to Section 13. To adjust the power output: 1 Press the or keys to increase or decrease power output the key to enable Eco Mode. Or Select NORM and press the key to disable Eco mode. 5 Press the key to exit the menu 4.13 Measure mode The transmitter has the capability of providing impedance measurements by determining the resultant impedance across the crocodile clips of the Direct Connection lead while connected to the utility. These measurements can be useful when assessing sheath fault severity. It is also possible to measure potential voltage that may be present on utilities to warn of potentially dangerous or harmful voltages present. In measure mode the measurement is derived from an AC signal applied to the utility from the transmitter Impedance & voltage measurements 1. Connect the Direct Connection leads to the utility and switch on the transmitter. 2. Hold down the key until MEAS is displayed and the measuring icon is activated. The transmitter display will now indicate the voltage level measured across the connection leads. 3. Press the key once and the display will indicate the impedance measured across the connection leads. The measurement icon will display the following symbols: Figure 4.13 Impedance and voltage measurements 4. To exit MEAS mode hold down the key until the display reverts back to the normal operating screen. Boost (Tx-10 only) Boost allows the Tx-10 transmitter to output its maximum output power. Boost mode can be set to operate for a specified period of time. To configure boost: 1 Press the key to enter the menu 2 Scroll to the BOOST menu using the or keys 3 Press the key to enter the BOOST menu 4 Set the BOOST duration using the or keys. You can choose 5, 10, 15 and 20 minute periods or ON for continuous operation 5 Press the key to accept your changes and exit the BOOST menu 6 Press the key to exit the menu To enable boost: 1 First configure the boost duration using the procedure above 2 Press and hold the key until BOOST appears on the transmitter LCD 3 The transmitter will automatically exit boost mode after the selected duration To disable boost: 1 Press the key to disable boost 4.12 Transmitter Eco mode When using alkaline D-Cells in Tx-5 and Tx-10 transmitter models you can extend the effective use of the batteries by enabling Eco mode. In Eco mode the power output of the transmitter reduces when the batteries can no longer provide the required output power.

© 2019 Radiodetection Ltd 19

Impedance measurements using active frequency 1. Connect the Direct Connection lead to the utility and switch on the transmitter. 2. Select the preferred frequency and output the signal. 3. Press the key once and the display will indicate the impedance measured across the connection leads and also the output power of the transmitter. 4. Press the key once to return to the normal operating screen. 4.14 CALSafeTM Usage-logging equipped RD7100 locators can be set to disable themselves once they are beyond the expected service / calibration date. When the unit is within 30 days of the service due date the unit will display at startup the number of days left. The locator will stop functioning on the service due date. CALSafeTM is disabled by default. You can edit the CALSafe service due date, and enable or disable the function using the RD Manager PC software package. Refer to the RD Manager operation manual for further information. 4.15 Usage-Logging RD7100 logging models feature a powerful data logging system which records all the instrument’s critical parameters and warnings in its internal memory each second. The automatic logging system is always active and cannot be disabled. Its memory is capable of storing at least 500 days of normal usage data – based on 8 hours operation per day. Logs can be retrieved using the RD Manager PC application for usage analysis and survey validation. Refer to the RD Manager operation manual for further information.

© 2019 Radiodetection Ltd 20 Section 5 - Locating cables and pipes This section introduces the principals and techniques of locating buried cable and pipe utilities with the RD7100 system. For more information on the theory of cable and pipe location, refer to The theory of buried cable and pipe location, which is available to download from radiodetection.com

5.1 Frequencies Passive frequencies Passive frequency detection takes advantage of signals that may be present on buried metallic conductors. Dependent on the model, RD7100 locators support up to three types of passive frequencies: Power, Radio and CPS signals. You can detect these frequencies without the aid of a transmitter if they are present on the utility you are surveying. Power FiltersTM The RD7100PLM locator allows you to take advantage of the harmonic signals found on power networks. When strong or interfering power signals are present, accurate tracing of a target cable can be challenging. Power FiltersTM allow you to establish if a single large power signal comes from one source or from the presence of multiple cables. The different harmonic characteristics of the detected lines can then be used to trace and mark their route. Once in Power Mode, press the key to switch out of Radiodetection’s sensitive Power Mode and scroll through the five individual Power Filters. The use of an individual Power Filter harmonic can also allow you to locate power lines in situations where the total signal would otherwise be too large. Active frequencies Active frequencies are applied to a buried conductor using the transmitter. The transmitter can apply a signal using three methods: Direct Connection In Direct Connection, you connect the transmitter output directly to the utility. The transmitter will then apply a discrete signal which you can locate using the locator. This is the preferred method of applying a transmitter signal to a utility and in the majority of applications will apply a stronger signal to the utility, which may increase the locate distance. To directly connect to a non-energized conductive utility: 1 Switch the transmitter off 2 Connect the Direct Connection lead into the transmitter accessory socket 3 Clip the red connection lead to the utility ensuring that the area around the connection is clean and that a positive connection is achieved 4 Clip the black connection lead as far away as possible and at 90° to the ground stake or suitable ground point nearby ensuring that a positive connection is achieved 5 The display will show the Direct Connection lead connected icon Figure 5.1 Direct Connection lead icon For more information about other signal connection accessories, refer to Section 8. WARNING! Direct Connection to live conductors is POTENTIALLY LETHAL. Direct connections to live conductors should be attempted by fully qualified personnel only using the relevant products that allow connections to energized lines. WARNING! The transmitter is capable of outputting potentially lethal voltages. Take care when handling the terminals, connection leads and ground stake, notify other technicians working on the line of the hazard and guard exposed conductors to prevent accidental contact. Induction In this mode of operation the transmitter is placed on the ground over or near the survey area. If a Direct Connection lead or signal clamp is not plugged into the transmitter, it will automatically go into induction mode. In this mode, only frequencies applicable for induction mode will be made available as the key is pressed. Once activated the transmitter will induce the signal indiscriminately to any nearby buried conductors. Please note that these signals will also be airborne and it is advisable to keep the distance between the transmitter and locator at least 10m / 30’ – this distance may need to be increased, particularly if depth measurements are taken. Signal clamp An optional signal clamp can be connected to the transmitter and clamped around a cable or pipe to apply the transmitter signal. This method of applying the transmitter signal is particularly useful on insulated live wires and removes the need to disconnect the supply to

© 2019 Radiodetection Ltd 21

the cable. Clamps are available up to 8.5” / 215mm in diameter. WARNING! Do not clamp around uninsulated live conductors WARNING! Before applying or removing the clamp around a power cable, ensure that the clamp is connected to the transmitter at all times. 5.2 Choice of frequency for active location The choice of signal frequency is an important factor for effective tracing and identification of buried lines, and there is no single frequency that covers all conditions. For simple instruments to be used by relatively non- technical personnel, there is no option but to make a compromise, and choose a single frequency high enough to give good performance in the induction mode, but not so high that it will couple too easily into unwanted lines. Active signals between 8kHz and 33kHz are commonly used for these applications. For more comprehensive equipment for problem-solving by technically competent technicians, a range of frequencies may be provided. Typical examples of these and reasons for their use are illustrated below. 512Hz Figure 5.2 512Hz active signal This low frequency is most useful for line tracing and identification over long distances. It does not couple easily to unwanted lines however it is too low for induction, and it falls within the band of power frequency harmonic interference. unwanted lines, and loses its strength over shorter distances than lower frequencies. 100kHz and Over Figure 5.5 100kHz active signal This very high frequency range deals with the difficult cases – induction onto small diameter lines in dry sandy soil, and short lengths of cable. It is very easy to apply by induction however it couples very easily to unwanted lines, and does not travel far. Selecting frequencies For more information see Section 5.1, , visit the Knowledge Base section in support.radiodetection.com or refer to the application note “ABC & XYZ of Locating Buried Pipes and Cables”, which is available as a free download from radiodetection.com To select a frequency on the locator: 1 Press the key to cycle through available frequencies 2 Alternatively, hold down the key and press the or keys to cycle up or down the range of frequencies You can change your transmitter’s output frequency manually using your transmitter’s keypad. To manually select a transmitter output frequency: 1 Press the key to cycle through available

© 2019 Radiodetection Ltd 22

Figure 5.3 8kHz active signal This medium frequency is the most useful general- purpose signal, high enough for induction, outside the power frequency interference band, and with limited coupling to wanted lines however it may not be high enough to impose a strong signal on small diameter line like telecom cables.33kHz Figure 5.4 33kHz active signal This higher frequency is easily applied by induction to most lines, so is very useful for initial search. It travels on small diameter line however it couples more easily to If locating using an active frequency you must also set your transmitter to output the matching frequency. NOTE: Some frequencies require that you connect an accessory, for example an A-Frame, before the frequency is available. 5.3 Antenna modes The RD7100 system supports up to four antenna modes, exclusively dedicated to locating cable and pipes, and to suit your particular application or the local environment. These are: • Null mode

frequencies To change frequencies using iLOC, refer to Section 13. • Peak mode • Peak+ mode • Guidance mode

Peak mode Peak mode provides the most sensitive and accurate mode for location and depth measurement. It provides a sharp Peak response with a corresponding small decrease in sensitivity. Peak mode cannot be disabled using the menu. In Peak mode the following indicators are displayed by the LCD: • Depth • Current • Signal strength • Compass To select Peak mode: 1 Press the key until the Peak mode icon is displayed on the LCD NOTE: The depth and current values will display automatically, although these values should not be considered accurate until the locator is directly over the target line. Peak+TM mode Peak+TM mode combines the accuracy of the Peak bargraph with a choice of Guidance or Null directional arrows. Guidance arrows provide visual indication of the direction to the target utility, and are designed to get you close to the Peak position faster, before using the Peak bargraph to pinpoint the target utility, Using Null arrows allow you to check for distortion before marking a point, and should be used when accurate locate measurements are required. Switching between arrow types: When in Peak+ mode, press and hold the key to toggle between Guidance and Null arrow types. You can also select the default arrow type in the locator menu: 1 Press the key to enter the menu 2 Scroll to the ARROW menu using the or keys 3 Press the key to enter the ARROW menu 4 Select NULL or GUIDE using the or keys 5 Press the key twice to return to the main locate menu. When using Guidance arrows: Use the proportional arrows to guide the locator along the path of the target cable or pipe. To accurately locate the center point of the target utility, for example to mark a point or take a survey measurement, use the Peak bargraph to pinpoint the Peak position. When using Null arrows: Use the arrow heads to place the locator above the NULL point. If the Peak response is not at a maximum then this is evidence of a distorted field. If the Peak response is at its maximum level where the Null point is located then there is no or very limited distortion present. In Peak+ mode the following indicators are displayed by the LCD: • Right and left arrows • Signal strength • Compass • Current • Depth To select Peak+ mode: 1 Press the key until the Peak+ mode icon is displayed on the LCD Guidance mode Guidance mode offers good performance in distorted fields and provides three indicators to guide the user towards the target line. The Left and Right Proportional Arrows become shorter as the locator approaches the target, and the Target Position Needle will move towards its central position. The Signal Strength reading will also reach its maximum value when the locator is positioned above the target. Any deviation from all three indicators showing the target position in the same location could signal the presence of a distorted field. In Guidance mode the following indicators are displayed: • Proportional left and right arrows • Target Position Needle • Signal strength • Gain • Compass • Current • Depth To select Guidance mode: 1. Press the key until the Guidance mode icon is displayed on the LCD

© 2019 Radiodetection Ltd 23

Null mode Null mode is used to verify a locate signal in environments with limited or no interference or distortion. Null mode gives a null response when it is directly over the line. In Null mode the following indicators are displayed by the LCD: • Signal strength. • Compass. • Right and left arrows. To select null mode: 1 Press the key until the null mode icon is displayed on the LCD The sharp, null response can be easier to use than the Peak response but is vulnerable to interference and should not be used for locating, except in areas where there is no interference present. Guidance Mode offers improved performance in such conditions while Peak+ mode can combine the Peak bargraph with Guidance arrows to combine fast and accurate locate tools. 5.4 Compass The LCD compass provides a visual indication of the direction of the target cable, pipe or sonde. The compass is available for all frequencies apart from Power, Radio and Passive. 5.5 Trace Line tracing can be accelerated by switching the locator to Guidance mode. Move the locator left and right while walking along the path of the line to place the target position Needle directly over the line. As you move the locator over the line, the left and right arrows (and an accompanying tone) will indicate if the target line is to the left or right of the locator. 5.6 Pinpoint Locating a target line in Peak, or Peak+, mode accurately defines the position of a target line after it has been traced and its position is approximately known. Start with medium output power from the transmitter, medium frequency on the transmitter and locator, and Peak or Peak+ mode on the locator. Set the locator sensitivity to approximately 50% by pressing the or key NOTE: it may be necessary to adjust the sensitivity level throughout the pinpointing to keep the bar graph on scale. 1 With the antenna perpendicular to the line, make traverses across the line. Define the point of maximum response. 2 Without moving the locator, turn it round as if it is on a pivot. Stop at the point of maximum response. 3 Hold the locator vertical with the antenna just above the ground and move the locator from side to side across the line. Stop at the point of maximum response. 4 With the end of the antenna close to the ground, repeat steps 2 and 3. 5 Mark the position and direction of the line. Repeat the steps of the procedure to increase pinpoint accuracy. If using Peak+ mode, switch to null arrows by pressing and holding the key. Alternatively switch to Null antenna mode. Move the locator to find the Null position. If the position of the Peak and the Null pinpoints correspond, it can be assumed that the pinpoint is accurate. The pinpoint is not precise if the marks do not correspond, but both marks will show an error to the same side. True line position will be close to the Peak position. The line lies half the distance to the other side of the Peak position as the distance between the Peak and the Null positions. Figure 5.7: Pinpointing with Peak and Null indicators Figure 5.6: Pinpointing a target line

© 2019 Radiodetection Ltd 24

Inductive search An inductive search procedure is a more certain technique for locating unknown lines. This type of search requires a transmitter and locator and two people. This type of search is referred to as a ‘two person sweep’. Before starting the sweep, define the area of search and the probable direction of lines crossing the area. Ensure the transmitter is switched on in induction mode. Figure 5.9: Inductive search The first person operates the transmitter and the second person operates the locator. The transmitter induces a signal onto lines as it passes over them and the lines are then detected with the locator at a suitable distance away from the transmitter (around 15 meters / 50 feet – although this will depend upon the level of induction power used.) Hold the transmitter with its length aligned with the assumed direction of any lines. 5.7 Sweep and search There are a number of techniques available for locating unknown lines in an area. Using these techniques is particularly important before conducting any excavation work to help ensure that buried lines are not damaged. Passive sweep 3 Traverse the area in a grid search, at a steady walk, and hold the locator comfortably with the antenna in line with the direction of movement and at right angles to any lines that may be crossed. The second person holds the locator at the start of the area to be searched and with the locator antennas at right angles to the probable direction of the buried lines. Set the locator sensitivity level as high as possible without the locator picking up any airborne signals directly from the transmitter. When the transmitter and locator are in line both operators start to move forward in parallel. The operator with the locator sweeps it backwards and forwards, keeping the locator vertical, as they proceed in parallel with the transmitter. This method allows for misalignment of the transmitter, locator and buried line. The transmitter applies the strongest signal to the lines directly below it, which are then located with the locator. Move the transmitter from side to side to establish the highest signal which indicates that the transmitter is also directly above the line(s). Mark the ground at the point of each Peak signal detected with the locator. Repeat the search along any other possible paths of lines. Once the positions of any lines have been marked, reverse positions, place the transmitter over and along each line in turn, and trace the line out of the search area. A passive sweep is used to locate Power Radio or CPS signals that may radiate from buried conductors. To perform a passive sweep: 1 Press the key to select the passive frequency you wish to locate. You can select from the following passive frequencies (model dependent): • Power • Radio • CPS (Cathodic Protection System) 2 Adjust the sensitivity to maximum; reduce the sensitivity to keep the bar graph on scale when there is a response. Figure 5.8: Passive sweep Stop when the locator response rises to indicate the presence of a line. Pinpoint the line and mark its position. Trace the line out of the area being searched. Resume grid search in the area. In some areas there may be a confusing amount of 50 / 60Hz power signals. Lift the locator 50mm / 2” from the ground and continue the sweep, or if using an RD7100PL / RD7100PLG locator, use the key to switch from Power mode and use Power Filters to discriminate individual lines. Switch the locator to Radio Mode. Increase sensitivity to maximum and repeat the above grid search procedure over the area. Pinpoint, mark, and trace out any lines that are located. In most, but not all areas, radio mode will locate lines that do not radiate power signals and a grid search should be made in both power and radio modes.

© 2019 Radiodetection Ltd 25 Section 6 - Locating RF Markers The RD7100 marker locator enables users to locate most common RF utility markers. These are also referred to as Electronic Marker System (EMS) and Omni MarkersTM. RF markers are used to identify buried utilities and are generally located, at regular intervals, directly on top of the utility they are marking. The markers are passive devices which resonate at a specific frequency when energized by the marker locator. Each utility is identified by a specific frequency and color. 6.1 Marker Mode Folding down the special marker loop antenna, on the front of the RD7100 locator, activates the Marker mode. In Marker mode, the locator can be used to locate a specific marker or to locate a buried conductor and a marker simultaneously. Entering Marker mode To enter marker mode fold down the marker antenna loop. The locator will enter the Marker mode and display the marker icon and identify the marker selected. NOTE: The locator defaults to the last marker used Changing RF marker type 1 Press the key to select the marker you wish to locate. The abbreviations for each type of marker are indicated in the table below: Display abbreviation Utility Color Frequency PWR* Electrical Power Red 169.8kHz H20 Water Blue 145.7kHz PDE German Power Blue Red / 134.0kHz SAN Sanitary Green 121.6kHz TEL Telephone / Telecoms Orange 101.4kHz GAS Gas Yellow 83.0kHz CTV Cable TV Black / Orange 77.0kHz PUR General / Non- drinkable water Purple 66.35kHz PFR French Power Natural 40.0kHz *Use of the red Electrical Power (PWR) marker locate mode is subject to radio licensing restrictions for Short Range Devices in the EU and possibly other countries. It is the responsibility of the user to ensure that the red Power (PWR) marker locate mode is only enabled in countries where radio licensing restrictions do not apply at the operating frequency of 169 kHz. If required and permitted, use the RD Manager software package to enable this frequency. Markers can be disabled using the Marker setup menu, see Section 3.3. Disabled markers are not available to be selected and will not be displayed. Markers can also be permanently disabled in the locator by using RD Manager. Refer to its operation manual for further information. © 2019 Radiodetection Ltd 26 Figure 6.1 Marker mode Marker type Marker mode icon

Combined mode In combined mode the locator is used to locate buried conductors (pipes or cables) and the selected marker simultaneously. In this mode, the left / right arrows indicate the buried conductor position while the bargraph, numeric display, and audio response indicate the amplitude of the received marker signal. To enter combined mode: 1 Press the key to select dual mode. The display will show the guidance locate proportional arrows. 6.2 Locating RF markers Single mode locating Use this mode when locating a RF marker only, for example, when locating markers used with water or gas plastic utilities. Proceed as follows: 1 Select Marker mode, see 6.1. 2 Select the type of marker you are trying to locate 3 Carry out a sweep of the area in which the markers are located to ensure that all markers are located. (set to maximum sensitivity) 4 Use the or keys to set the locator’s sensitivity to low and pinpoint the marker(s) CAUTION: The radio signals generated by marker locators may be reflected by other marker types. This may cause the locator to show a response to a different utility marker type, if it is close enough. 5 Once you have located a specific utility marker, scroll through all available marker types by pressing the key to ensure that no other marker types display a greater response and to confirm that you have located the correct utility marker type. NOTE: If you cannot locate the marker ensure that you have selected the correct marker type for the utility you are trying to locate and have the sensitivity set to maximum. Combined mode locating Use this mode when locating the marker and conductor simultaneously. In this mode no null mode sensitivity adjustments can be made whilst marker sensitivity adjustments are possible by using the or keys. To set up the system for dual locating proceed as follows: 5 Locate the conductor using the left / right arrows as normal but sweep the area either side of the conductor to ensure that all markers are located. When an RF marker is approached the volume and bargraph reading will increase and decrease as the marker is passed. Use the or keys to set the locator’s RF marker sensitivity as required to help pinpointing the marker. CAUTION: The radio signals generated by marker locators may be reflected by other marker types. This may cause the locator to show a response to a different utility marker type, if it is close enough. 6 Once you have located a specific utility marker, switch back to Single mode locating, by pressing the key, and scroll through all available marker types by pressing the key to ensure that no other marker types display a greater response and to confirm that you have located the correct utility marker type. NOTE: If you cannot locate the marker ensure that you have selected the correct marker type for the utility you are trying to locate. NOTE: A thorough scan of the area as described in 5.7 is recommended when locating for cable and pipes 1 Select the same frequency on the locator as used by the transmitter. 2 Pull down the RF marker antenna on the locator. The marker symbol is displayed. 3 Press the key to select the specific marker you are trying to locate. 4 Press the key to select dual mode. The display shows the null symbol and location arrows, and the locate frequency is shown in place of the marker type. Figure 6.2 Combined mode

© 2019 Radiodetection Ltd 27 Section 7 - Depth and current readings

7.1 TruDepthTM The RD7100 locator provides automatic depth of buried conductors, sondes and RF utility markers when the locator is correctly orientated above the target line, sonde or in close proximity of the RF marker. Current readings are also displayed simultaneously if the locator is orientated correctly (feature not available in sonde or RF utility marker modes). Depth and current readings are automatically displayed simultaneously, but if the locator is not correctly orientated neither reading will be displayed. Depth range and accuracy vary depending on the makeup and type of target utility (e.g. cable, pipe, sonde or RF marker), its depth and external environmental factors like electromagnetic noise, ground conditions and interference. WARNING: The accuracy of depth measurement is subject to a number of factors and is meant as a guide only. Never use the depth measurement to define mechanical digging depths. Always follow local safe digging guidelines. The depth measurement is to the center of the pipe, cable, sonde or RF marker. The best readings are typically detected from ‘active’ signals output by a transmitter rather than from passive sources. The RD7100 RF marker locator is capable of determining cable depth when locating some passive power signals. However passive signals on lines are less suited for measuring depth because accuracy can be compromized by interference- e.g due to the passive signal being present on more than one line. WARNING! Do not make depth measurements near bends or tees in the line. Go at least 5m (16ft) from a bend for best accuracy. TruDepth for RF Markers The RD7100 locator is capable of automatically estimating the depth of a buried marker when it is in close proximity to it. In order to get the best possible accuracy it is important to ensure the locator is directly above the marker position by pinpointing its exact position first as described in paragraph 5.6 TruDepth for buried conductors or sondes TruDepth and Compass It is important to note that the RD7100 locator will only display depth and current (in applicable modes) when the locator is correctly orientated above the target line, cable or sonde. To ensure the locator is correctly orientated, use the Compass feature. When locating lines, make sure the Compass display is in the North / South orientation position. When locating sondes (see Section 12.5), make sure the Compass display is in the East / West orientation. Figure 7.1: Taking a depth reading To minimize signal distortion, do not apply the signal by induction. If Direct Connection or signal clamping is not possible, place the transmitter in induction at least 15m (50ft) from the point of any depth measurements. Depth measurements may not be accurate if there is audible interference or if part of the transmitter signal has coupled to a nearby line. Confirming the Peak position coincides with a Null position indicates that the position is suitable for making a depth estimate. Figures 7.2: Depth readings • Pinpoint the target line accurately with the locator • Check the locator is directly over the line, the antennas are at right angles to it and the locator is vertical. Adjust the sensitivity level to bring the bar graph indication to approximately 50% If the ground appears to radiate a strong field, perhaps near a radio station, check depth by holding the bottom of the antenna 50mm (2”) above the ground and subtract this reading from the indicated depth.

© 2019 Radiodetection Ltd 28

5 Compare this reading with the depth reading on the locator. Refer to appendix 13.5 to verify if the Locator is operating within specification. When locating for conductors or sondes There are two ways of checking the calibration of the locator in the field. Both methods require the use of a transmitter: Method 1 Place the transmitter on top of a non-metallic object, 18” / 500mm in height or more, on the ground and away from any buried lines. Switch the transmitter on in induction mode. Hold the locator with the blade horizontal and pointing towards the front of the transmitter and approximately five meters from the front of the transmitter. 1 Switch the locator on. 2 Select the same frequency as is selected on the transmitter but make sure that this frequency is in the sonde mode. 3 Move the locator from left to right and when the bargraph reading is at its Peak note the depth as indicated on the locator. Measure the distance from the base of the locator to the center of the transmitter using a tape measure. 4 Compare this reading with the depth reading on the 7.2 Verifying depth measurements Check a suspect or critical depth reading by lifting the locator 50mm (2”) above the ground and repeating the measurement. If the measured depth increases by the same amount it is a good indication that the depth reading is correct. When locating for a conductor or sonde, depth measurements should be precise to ±3% if conditions are suitable. However, you may not always know if the conditions are suitable so the following techniques should be used to check critical readings: • Check that the route of the line is straight for at least 2 meters (6 ft) to either side of the measurement point. • Check that the signal response is reasonably constant over the 15 meter distance to the transmitter and make depth measurements to either side of the original point. • Check that there are no adjacent lines carrying a significant signal within 1 to 2 meters (3 to 6 ft) of the target line. This is the most common source of error of depth measurements as a strong signal coupled to an adjacent line can often introduce ± 50% error. • Make several depth measurements at points slightly displaced from the line’s apparent position. The shallowest indication will be the most accurate and will also indicate the line’s position most accurately. locator. The locator can be considered accurate if the difference between the depth reading on the locator and the distance measured with the tape is less than 10%. Method 2 1 Apply a signal to a cable or pipe of known depth. 2 Locate the cable or pipe; the locator will display depth on the LCD automatically. 3 Compare the depth reading on the locator with the actual depth. Checking depth accuracy This paragraph describes several quick and easy ways of verifying that the depth reading on the locator when used for markers or conductors and sondes is within acceptable limits. Refer to this if you are getting inaccurate depth readings from a cable or pipe for which you know the approximate depth. Inaccurate depth readings could be the result of the locator picking up a stronger signal such as another cable or pipe running in close parallel to the target pipe or cable. NOTE: The accuracy of depth measurement is subject to a number of factors and is meant as a guide only. Exercise caution when performing any excavation. 7.3 Current readings Identifying a utility using current measurements Measuring current value on a line helps confirm the identity of the line and may provide information about the condition of cable insulation or pipe coating. When locating for RF Markers 1 Set the locator to marker mode and select the correct marker type. 2 Place the marker on top of a non-metallic object, such as a cardboard box, on the ground and away from any buried lines or other sources of interference. 3 Place the locator horizontal, at a distance equal to half the maximum depth range distance for the marker you are using (for example 700mm / 271⁄2” for the center of a marker ball to the bottom of the locator). 4 Note the depth as indicated on the locator LCD.

© 2019 Radiodetection Ltd 29

About current measurements The transmitter applies a signal or current onto a target line. The current decreases in strength as the distance from the transmitter increases. This rate of decrease depends on the type of line and on soil conditions. Regardless of the type of line and the frequency being used the rate of decrease should be regular with no sudden drops or changes. Any sudden or abrupt current change indicates that the line or its condition has changed. Figure 7.3 Current readings In congested areas, where there is more than one line, the locator may sometimes detect a stronger signal from an adjacent line to which the signal has coupled or shares common grounding because it is nearer the surface. Although current measurement compensates for depth, signal response will be less as the depth increases. The line with the highest current measurement, rather than the line giving the strongest response, is the target line to which the transmitter signal has been connected. Measuring current provides useful information about the position of bends and intersections. Measuring current after a tee will indicate the main line that pulls more current along its greater length. Figures 7.4 – 7.6 Taking current readings Applying a transmitter signal The transmitter signal can be connected, clamped or induced to the target line in the same way as the signal for line tracing is applied. WARNING! Direct Connection to live conductors is POTENTIALLY LETHAL. Direct Connections to live conductors should be attempted by fully qualified personnel only using the relevant products that allow connections to energized lines. Signal current measurements

Pinpoint the line and confirm the accuracy of the Peak pinpoint with null arrows. Check the locator is directly over the line, with the antennas at right angles to it and vertical. The locator will automatically estimate and display depth on the LCD. A signal coupled to a nearby line may distort the accuracy of the measurement. If the accuracy of the reading is suspect, sweep the area to check if other nearby lines are radiating the signal. If other signals are © 2019 Radiodetection Ltd 30 causing interference, it may be necessary to make the current measurement at another point along the line. Both antennas are needed to make a current measurement and locator accessory antennas such as a normal clamp or stethoscope cannot be used. Because current measurement is a function of depth, it is only available in active locating modes. Figure 7.7: Current readings using transmitter signals © 2019 Radiodetection Ltd 31 Section 8 - Locating techniques

8.1 Identifying target utilities Induction If several conductors are running in parallel, and it is not possible to connect a transmitter, each line may be located separately. Proceed as follows: 1 Perform a sweep of the area to find the position and number of conductors in the area. 2 Map the direction in which the conductors are going. To trace the lines: 1 Select induction mode on the transmitter. 2 Select the same frequency as on the locator. 3 Place the transmitter on its side and in line with a conductor 4 Ensure the conductor is directly below the transmitter 5 This will ‘null out’ the signal directly below the transmitter, placing no signal on that conductor, and enable the other conductors to be located 6 Locate each conductor and mark its position 7 Move the transmitter down the route and continue locating and marking. 8 Trace each conductor out of the search area until the target can be accurately located. Unwanted signal coupling Unwanted coupling of the signal from the target line to another nearby line is one of the most common location problems. It leads either to an error in the marked position and depth of the target line or to marking the wrong line. A certain degree of coupling is unavoidable in many situations but there are ways in which a careful user can reduce coupling and increase location reliability. • Avoid applying the signal by induction. The signal may be coupling to more than one line directly from the transmitter. Use the signal clamp where possible. • Identify points where lines may be bonded or in close proximity to each other. Work toward these points rather than away from them. For example, if gas and water pipes are bonded within a building, apply the signal at the valves or access points in the road rather than in the building. • Reduce coupling to a parallel line by using a low signal frequency where available • Return signal flowing on another line. Use a double- ended connection to by-pass the ground return if possible • Choose a signal application point where the line is furthest from other lines and not in a congested area • When using single-ended connection, site the ground stake as far from the target line as possible and away from other buried lines • Avoid using existing structures for ground connections; other buried lines may be bonded to them • A bad ground connection or just laying the ground lead on the surface at right angles to the line may result in less coupling than a good ground provided long distance tracing is not required. Figures 8.1 – 8.4: Nulling utilities & interference from services

© 2019 Radiodetection Ltd 32

• Metal fence posts 8.3 Double-ended connections Large diameter water pipes and gas distribution pipes that are laid in sections sometimes have insulated joints between the sections and can be difficult to locate using a single ended connect. This is because when using a single ended connection ground return, signals can often cause confusion by returning to the transmitter along other lines. The problem sometimes occurs when return signals appear stronger than on the target line, usually because the target line is deeper than the line carrying the return signal, or the return path may be a better electrical conductor than the target line. Applying a double-ended transmitter connection is a useful technique for positively tracing and identifying a target line in a situation such as a heavily congested industrial site, provided there are access points at each end of the line. Making a double-ended connection Connect the transmitter to an access point on the target line. The transmitter ground is connected with a long cable to another access point further along the line. A complete circuit is achieved without using ground as a current return path. The long cable should be kept as far away as possible from the expected route of the line. This method of applying the transmitter signal is ideal for positive identification of a target line. When a connection has been made to two points on the same line, the same level of current should be detectable around the circuit. The locator display should remain constant if the depth of the line does not change. 8.2 Signal & ground connection Manhole covers Sometimes when locating, it is not possible to insert the ground stake into the earth, for example, when locating on hard ground such as roads. In this case, the ground return can be made by attaching the ground lead to the metal frame of a manhole. Using lighting columns Direct Connecting to a metal, street-lamp column is almost as effective as connecting to the cable sheath itself. Normally the cable sheath is bonded to the metal column, therefore a simple connection onto the column enables the user to locate the street lighting quickly and safely without having to call out a technician from the lighting company. If the lighting column is made from concrete make the transmitter connection to the cable sheath unless the cable is earthed to the inspection doorframe. Connection to the cable sheath applies the transmitter signal for a considerable distance enabling the locator to trace cables feeding illuminated street furniture as well as other street lights. WARNING! The live cable connector is for use only by operators licensed or permitted to work on live cables. The use of a street light column as a means of applying a signal to other power cables on the same electric circuit is a possibility. The signal may be weak using this method because it may have travelled some distance back to the sub-station and out again on the other system. With the locator used on a high sensitivity setting it is often possible to locate a cable, which would otherwise have been difficult or inconvenient to energize with the transmitter signal. Finding a good ground point When using a Direct Connection, it is important to get the best possible grounding for the transmitter. This provides the lowest resistance ground path and the best output signal. If it is not possible to use the ground stake the following are examples of good alternative ground points: • Metal manhole covers • Metal drainage grates • Metal railings Figure 8.5: Making double-ended connections

© 2019 Radiodetection Ltd 33

Section 9 - Fault-finding 9.1 About fault-finding RD7100PL and RD7100TL locators are capable of locating cable to ground faults caused by damaged cable sheaths and can also be used to locate damage to insulation on pipelines. This process is known as Fault- Finding and uses specific fault find signals applied to the target. Fault find signals can only be applied using Direct Connection method. The A-frame accessory is used to locate cable sheath faults on power and telecom cables or insulation faults on pipelines. To use Fault-Find you will need the following equipment: • RD7100 locator • Tx-5 or Tx-10 transmitter • Accessory A-frame with connecting lead • Direct connection lead and earth stake There are 2 types of signals that can be used for fault finding: • 8K Fault Find – useful for sheath faults on cables but can also be used on pipelines over shorter distances. 9.2 Preparation Using RD7100 standard locating techniques locate the cable or pipe for a short distance and trace and mark its route. Remove all earth bonds from the line to be traced during the fault-finding survey. If there are any earth bonds along the path the fault find signal may direct the user to this location as this will be the preferred path for the fault find signal to leak away into the ground and may result in the fault not being located. Connecting the transmitter 1 With the transmitter switched off connect the Direct Connection lead into the transmitter accessory socket 2 Clip the red connection lead to the cable, cable sheath or pipe ensuring that the area around the connection is clean and that a positive connection is achieved 3 Extend the black connection lead as far away as possible at 90° to the probable route of the target cable and clip the connector to the ground stake ensuring that a positive connection is achieved NOTE: Always connect the black connection lead to a ground stake and not a water pipe or buried cable, as these may carry the signal. Reference readings It is good practice to obtain a reference reading from the ground stake before you attempt to locate a fault on a target line. Reference readings help to provide the following information: • Severity of fault • Survey interval Before taking the reference reading set up the transmitter and locator as follow: On the transmitter: 1 Select a fault-finding frequency using the key 2 Use the or keys to increase or decrease the output signal level 3 If required you can use the BOOST setting if the fault is located on a high resistance cable or if the cable is long WARNING! By selecting 8KFF the transmitter will have the ability to output high voltages and a high voltage warning icon will appear on the transmitter’s LCD. On the locator: 4 Connect one end of the connection lead to the A- frame socket 5 Connect the other end to the locator accessory socket 6 The locator will automatically recognize the A-frame and display the A-frame icon on the LCD 7 Select a fault-finding frequency using the key Obtaining a reference reading: Position the locator approximately 2m (6 feet) from the ground stake and push the A-frame spikes into the ground with the green spike towards the ground stake Attach the locator to the A-frame by the retention hook. (If you are holding the locator separately, make sure that the locator is in line with the A-frame and is pointing towards the green spike.) The fault direction arrow should be pointing away from the ground stake. If it is not, make sure that the transmitter is connected correctly (red connector to the cable and black to the ground stake). Take the dB reading and keep it for reference. If there is a single fault on the cable, it will be approximately the same dB value as the reference reading. NOTE. To establish how often to take readings on the cable or pipe, move away from the ground stake and take further readings until the arrow has difficulty in

© 2019 Radiodetection Ltd 34

locking and the dB reading is low. Measure the distance that the locator is now away from the ground stake. This is the distance that you can safely use between taking readings on the cable or pipe to ensure that you do not miss the fault. 9.3 How to find a fault Starting from the transmitter, walk along the cable or pipe route pushing the A-Frame spikes into the ground with the green spike pointing away from the transmitter. Where there are no faults the dB reading will be low and the direction arrow may flicker forward and back. NOTE: Flickering arrows may also indicate that you may be too far away from the fault or ground stake (or both) for the locator to lock on. Figure 9.1: Cable sheath fault-finding If you are trying to locate high resistance faults or there is a long distance between faults, carry on with the survey and the locator will lock on when you get closer to the fault. Figure 9.2: Locating faults with the locator and A-frame Take readings at the survey intervals determined by the reference reading. To locate the cable or pipe while using the fault find signal during a Fault-Find survey, press the key once and the locator will switch to Peak locate mode. To use alternative antenna modes, press the key to step through available antenna modes. To get back to fault find mode step through all available antenna modes until the locator goes back to fault find mode. Note: While the A-Frame is connected to the locator, depth and current measurements will not be available. If depth or current measurements are required, remove the A-Frame lead from the locator. As a fault is approached the Fault-Find direction arrow will lock on to the fault signal, point forward and the dB readings will increase. When the fault is passed the arrow will point back towards the transmitter. Take readings at smaller survey intervals to determine the exact point of the fault. When the A-frame is directly over the fault the dB reading will drop as shown opposite. Mark the ground to show the position of the fault. Find the maximum dB reading in front of the fault by pushing the A-frame into the ground at small intervals. Note the dB reading. If the reading is approximately the same as the reference reading, you can assume that there is only one fault. If the reading is less than the reference reading, keep surveying the cable for other faults. NOTE: If the cable or pipe runs under a paved surface, the fault can often be pinpointed by fault finding in the grass / soil adjacent to the paving. Reduce the distance between placing the A-frame spikes in the ground to allow for the increased distance to the actual fault position.

NOTE: The values given are for illustration purposes only and may not be the same as those obtained in other situations. To pinpoint the fault, turn the A-frame 90° to the cable or pipe and Fault-Find until the exact point is found. Where the arrow direction changes the center line of the A- frame is now directly over the fault. NOTE: If the cable or pipe runs under a road, use the equipment as normal on the road surface as it can sometimes detect signals when working on blacktop, concrete, or paved surfaces. If necessary, try wetting the road surface. Pouring a very small amount of water around the bottom of the A-frame spikes before each Fault-Find will generally ensure a good ground connection. © 2019 Radiodetection Ltd 35 Section 10 - Survey Measurements

RD7100 RF marker locators are capable of transmitting survey measurements to an external device running a compatible software application. When a measurement is taken, the RD7100 locator will transmit the most relevant measurements taken and info data, such as: • Log number • Current • Gain • Depth • Signal • Phase • Frequency • Marker type These measurements, taken at specific points indicated by you, can be used to report and map all your findings. Refer to Error! Reference source not found. for more i nformation about Bluetooth pairing. 10.1 Saving measurements To send survey measurements, press the key. To achieve accurate results the locator must be kept as still as possible during the saving process. If Bluetooth is switched on and the Bluetooth survey measurements transmission are active the locator will attempt to send the saved measurement to a paired device running a compatible application. If your paired device is out of reach, or if its Bluetooth features are disabled, the locator will display an error code. To avoid these errors ensure that your paired device is within range and correctly paired. For more information about Bluetooth, please refer to Section 11. NOTE: A flashing depth and/or current reading display means that the measurement is poor and should be taken again. Poor readings may be caused by nearby conductors or sources of electromagnetic interference.

© 2019 Radiodetection Ltd 36 Section 11 - Bluetooth wireless connections RD7100 cable, pipe and marker locators feature a Bluetooth wireless module, as standard, providing the ability to pair to a PC, Android or PDA devices running a compatible application.

NOTE: The RD7100 locator wireless features may be subject to national and or local regulations. Consult your local authorities for more information. WARNING! Do not attempt any wireless connection in areas where such technology is considered hazardous. This may include: petrochemical facilities, medical facilities or around navigation equipment. 11.1 Switching Bluetooth On By default RD7100 locators are shipped with the Bluetooth wireless connection module disabled. To switch Bluetooth On: 1 Press the key to enter the menu 2 Scroll to the BT menu using the or keys 3 Press the key to enter the BT menu 4 Scroll up or down to the ON option 5 Press the key to switch Bluetooth ON and return to the previous menu 11.2 Switching Bluetooth off You can switch Bluetooth off to prolong battery life or comply with regulations in areas where wireless communications are considered hazardous. To switch Bluetooth off: 1 Press the key to enter the menu 2 Scroll to the BT menu using the or keys 3 Press the key (locator) or the key (transmitter) to enter the BT menu 4 Scroll up or down to the OFF option 5 Press the key to switch Bluetooth off and return to the previous menu 11.3 Pairing to an Android, PDA or PC Pairing Pair the RD7100 locator to your Android, PDA or PC device using its Bluetooth manager On the locator: 1 Press the key to enter the menu 2 Scroll to the BT menu using the or keys 3 Press the key to enter the BT menu 4 Scroll up or down to the PAIR menu 5 Press the key to enter the PAIR menu 6 Scroll up or down to the BT-PC option 7 Press the key and the locator will be ready to your compatible device On your Android device: 1 Navigate to Settings > Bluetooth 2 Ensure that Bluetooth connectivity is switched on devices 4 Select the RDMRX-XXX device 5 If asked for a passkey, enter 1234 NOTE: The procedure below describes the pairing process between a RD7100 locator and a PDA. Pairing to a PC follows the same steps for the RD7100 locator and similar steps for your PC or laptop. Consult your PC or laptop Bluetooth pairing instructions to pair with the RD7100 locator. NOTE: The procedure for pairing your PDA may differ depending on the PDA make and model. The following procedure should apply to most PDAs. On your PDA: 1 From the PDA’s Start menu, select Settings then select the Connections Tab followed by the Bluetooth icon 2 Ensure the Bluetooth radio is switched on and make the PDA visible to other devices 3 Select the Devices tab and scan for new 4 Create a partnership with the RD8M_xxx device 5 If asked for a passkey, enter 1234 6 Select the COM Ports tab and make a New Outgoing Port with the RD7100 locator. Note the port number of the selected COM port

3 Scan for a new device to add to the list of paired partnerships © 2019 Radiodetection Ltd 37

11.4 Bluetooth Protocol RD7100 locators can transmit survey measurements to a paired PDA device running a compatible program. To set the locator to work with Radiodetection’s RD Map or SurveyCERT+ application, you need to set the data format to the PPP protocol: 1 Press the key to enter the menu 2 Scroll to the BT menu using the or keys 3 Press the key to enter the BT menu 4 Scroll up or down to the PROT menu 5 Press the key to enter the PROT menu 6 Scroll up or down to the PPP option 7 Press the key to confirm your choice and exit the menu The ASCII protocols can be used when using third party apps. Refer to the software supplier’s operation manual for instructions 11.5 Bluetooth standby mode When using the Bluetooth connection on the RD7100, the Bluetooth module is by default kept in standby mode. This can help to increase the locator battery life and in some applications reduce potential interference from the Bluetooth module. The RD7100 locator provides users with the option to set the Bluetooth module to STANDBY or ON. In the ON position the Bluetooth module will be permanently ready to send data, which can help to speed up the transfer times compared to that of modules set to STANDBY mode To set Bluetooth to STDBY : 1 Press the key to enter the menu 2 Scroll to the BT menu using the or keys 3 Press the key to enter the BT menu 4 Scroll up or down to the STDBY menu 5 Press the key to confirm your choice To set Bluetooth connection mode to ON: 1 Press the key to enter the menu 2 Scroll to the BT menu using the or keys 3 Press the key to enter the BT menu 4 Scroll up or down to the ON option 5 Press the key to confirm your choice 11.6 Troubleshooting Successful wireless communication depends on a number of factors including: battery life, electromagnetic interference, device memory and physical obstructions. Ensure that the RD7100 locator and any other wireless device is sufficiently charged for wireless communication. Note that many PDAs will suspend wireless connections when their battery capacity drops below a threshold percentage. Consult your device’s documentation for more information. Excessive electromagnetic interference can limit the range of wireless communication and / or corrupt data. Your PDA device may have insufficient memory to maintain a wireless link, particularly if the connection is sustained over an hour or longer. Make sure you quit applications on your PDA using the method described in your device’s documentation. Keep your paired device and the RD7100 locator within 10m (30ft) to maintain a wireless connection. Resetting connections If you experience problems with the RD7100 wireless Bluetooth technology features, Radiodetection recommends resetting the connection and then pairing your device again. To reset the wireless connections: 6 Press the key to enter the menu 7 Scroll to the BT menu using the or keys 8 Press the key to enter the BT menu 9 Scroll up or down to the RESET menu 10 Press the key and the locator will purge all current connections 11 Re-pair your devices as described in section 11.3 and 11.4

© 2019 Radiodetection Ltd 38 Bluetooth error codes If an error occurs when attempting to perform any Bluetooth command using the locator to the transmitter or the locator to a paired device, the LCD will display a code to help you resolve the problem on the locator. The codes are as follows: BT Code Description BT001 Bluetooth not configured for this unit BT002 Internal Bluetooth error BT003 Locator not paired with transmitter BT004 Locator not paired with PC / PDA BT005 Paired but connection attempt failed. Power cycling may be required BT009 Corrupt response received from PDA BT010 Transmission to PDA failure Table 12.1: Bluetooth error codes © 2019 Radiodetection Ltd 39 Section 12 - Using accessories

12.1 About accessories Both the transmitter and locator are compatible with a wide range of accessories. When an accessory is connected, the locator or transmitter will recognize it and will enable the mode appropriate to the accessory. For example, attaching an A-Frame to the RD7100 locator will automatically switch the locator to fault-find mode and limit the number of available frequencies to those that are compatible with the A-Frame. The LCD will also display an icon of the accessory and will remove any nonessential icons from the screen. Radiodetection supply an accessory sheet with pictures and details of all applicable accessories which is available on radiodetection.com For a full list of supported accessories that are available for purchase, refer to the appendix 12.2 Headphones Radiodetection supplies an optional headphone set for the RD7100 locator. The headphones feature an adjustable headband to ensure a tight fit when used in the field. The accessory headphones also feature volume adjustment for both left and right speakers. Connect the 3.5mm headphone jack into the locator’s headphone socket, which is located next to the accessory panel. WARNING! Before wearing headphones, lower the locator’s volume levels to help prevent damage to your hearing. WARNING! Wearing headphones may impede your awareness to dangers in the field such as moving traffic or other heavy machinery. Exercise caution! 12.3 Locator clamps A locator clamp is used to positively locate and identify a cable when several cables are running close together. A target cable can be identified in a chamber, on a tray or other access point by fitting a clamp to the locator and examining each cable in turn. Signal strength response shown on the locator display should be noted for each cable. When to use clamps Clamps can be used where: • Several cables or pipes run in close proximity to each other. • A cable or pipe is accessible at an inspection hole or manhole. Connecting a clamp 1 Put the clamp connector into the accessory socket on the front of the RD7100 locator. 2 Place the clamp around the pipe or cable and switch the locator on. 3 Set the frequency to the same as that on the transmitter. 4 Put the clamp around each cable in turn and note the bar graph response. Compare the strength of response from each cable. The cable with a substantially stronger response than the others will be the cable to which the transmitter signal has been applied. To ensure that the target cable has been correctly identified, reverse the positions of the transmitter and locator and check that the strongest response is still received from the target cable by the locator in its new position. Locator clamp range Standard clamps The clamp plugs into the locator accessory socket and is used for cable identification at points where the cable can be accessed. The standard clamps are suitable for cables up to 130mm (51⁄4”) diameter. Figure 12.1: Connecting clamps

© 2019 Radiodetection Ltd 40

even if it has no actual ground connection, providing a reasonable length is buried either side of the clamp to provide capacitive coupling to ground (earth). NOTE: It is not necessary to make a ground connection from the transmitter when using the clamp. Transmitter clamp range Although transmitter and locator clamps look the same, they have different internal windings. To prevent the wrong clamp being connected, transmitters and locator clamps have plugs of a different orientation. Figure 12.2: Standard Clamp Standard signal clamps The standard clamps apply the transmitter signal very selectively and effectively to a target cable up to 130mm (51⁄4”) in diameter using frequencies from 8kHz to 200kHz Figures 12.4 – 12.5: Connecting transmitter clamps The standard and small clamps have a double spring action for positive toroidal contact. WARNING!. The transmitter must only be connected to live services using the appropriate accessory such as a plug connector or live cable connector. Small clamp The small clamp performs the same function as the standard clamp but is useful in cramped situations where there is insufficient access for the standard clamp. The small clamp is suitable for cables up to 50mm (2”) diameter. 12.4 Transmitter clamps The transmitter clamp fits around a pipe or cable and safely applies a signal to a live insulated cable without interrupting or disconnecting the supply. The clamp applies a very discriminating signal to a target line with reduced coupling to other lines. A clamp can sometimes be a more effective method of applying the signal than Direct Connection. The target line will carry the strongest signal. The other lines will carry the weaker return signal. If the system comprises only two conductors, they may carry equal signals. WARNING! Do not clamp around uninsulated live conductors WARNING! Before applying or removing the clamp around a power cable, ensure that the clamp is connected to the transmitter at all times. The clamp may buzz or vibrate if it is placed around a power cable that has significant net current flow. This is normal and does not harm the equipment. Connecting the clamp 6 Plug the clamp into the transmitter output socket. 7 Put the clamp around the pipe or cable and ensure that the jaws are closed. Switch the transmitter on. The display will show the Clamp connected icon Figure 12.3 Clamp connected icon The line should be grounded (earthed) on each side of the clamp for the signal to transfer to the line. Ground the line if necessary. An insulated cable may be traced

© 2019 Radiodetection Ltd 41

inspecting drains. Sondes used in underground drilling and boring operations are normally housed in the boring or drill head behind the boring or drill bit. Locating and tracing a sonde Insert the sonde in the drain or duct access and locate it while it is still just in view at the drain or duct entrance. Hold the locator vertical directly over the sonde with the antenna in line with the sonde. Adjust the locator sensitivity so the bar graph reads between 60% and 80%. The sonde radiates a Peak field from the center of its axis with a ghost signal at each end of the Peak. Move the locator a little way behind and then in front of the axis of the sonde to detect the ghost signals. Finding the two ghost signals positively confirms the locate. Reduce the locator sensitivity to lose the ghost signals but still indicate a clear Peak response directly over the sonde. Locator sensitivity is now set for tracing the duct or drain unless the distance between sonde and locator changes. Propel the sonde three paces along the drain or duct and stop. Place the locator over the supposed position of the sonde. Do not adjust the sensitivity level. Figure 12.6 Sonde deployment To locate a sonde: 1 Move the locator backwards and forwards and stop when the bar graph indicates a Peak. You can use the LCD compass to orient the blade of the locator with the direction of the sonde. 2 Rotate the locator as if the blade is a pivot. Stop when the bar graph indicates a Peak. 12.5 Sondes Sonde overview A sonde is a self-contained battery operated transmitter used for tracing the paths of pipes, ducts, sewers and drains and in the precise location of blockages or collapses. The sonde can be fitted to a flexible rod for insertion or pushing through pipes etc. and the smaller diameter sondes can be used in conjunction with jetting machines and blown through the duct. A suitable Radiodetection locator can then be used to locate the sonde. Check that your locator features sonde locating before starting. Choosing a suitable sonde Radiodetection offers a wide range of sonde to suit most applications: From the 1⁄4” / 6mm diameter S6 33kHz microsonde which, with a range of 6.6” / 2m, targets fiber-optic micro ducting or other small non-conductive pipes, to the 33kHz Super Sonde, which with a depth range of 50 feet / 15m targets deep sewer pipes. Consult the precision locate accessory range brochure or web page on radiodetection.com for a full list of all available sondes and their technical specifications. Check that the sonde has sufficient range for the application and is dimensionally small enough and sufficiently robust for the application. Ensure that the frequency of the sonde corresponds with the locator frequency; the locator will not locate the sonde unless the frequencies are the same. Sondes are marked with their transmitting frequency. Ensure that the means of propelling the sonde is available together with the correct fittings and couplings. Preparation Insert a new battery into the sonde. A new battery or a freshly recharged battery should be used at the beginning of each day and preferably at the start of each new job. Before inserting the sonde, check that the sonde and locator are at the same frequency and working correctly. To do this, place the sonde on the ground at a distance from the locator that is equal to the rated depth of the sonde. Point the locator at the sonde with the antenna in line with the sonde (the opposite of using the locator to locate a line) and check that the bargraph reading exceeds 50% at maximum sensitivity. Propelling a sonde Sondes have a thread at one end for connecting to drain rods, or to other devices for inserting and propelling the sonde along a drain or duct. Sondes may be floated along drains at the end of a tether and floats are available for fitting to the sewer sonde and super sonde. Sondes can be strapped to high-pressure water jets or similar devices used for cleaning, maintaining and

© 2019 Radiodetection Ltd 42

blade is always in line with the sonde. Find the null positions A and B (See Figure 8.10). Measure the distance between them and multiply by 0.7 to give an approximate depth measurement. FlexiTrace The FlexiTrace is a traceable plastic covered fiberglass rod incorporating wire conductors and is used for locating small diameter, non-metallic pipes to a depth of 3 meters. The FlexiTrace can be inserted into a pipe or duct as small as 9mm / 3/8” internal diameter, and ith a minimum bend radius of 250mm. Batteries are not required, as the FlexiTrace is powered by any Radiodetection transmitter. The FlexiTrace has a maximum power rating of 1W. When using the FlexiTrace with a Radiodetection Tx-5 or Tx-10 transmitter the output limit must be set to 1W in the MAX P menu and the output voltage limit set to LOW in the MAX V menu. Figure 12.7 Locating a sonde 3 Move the locator from side to side until the bar graph indicates a Peak. No settings are required for the Tx-1 transmitter. WARNING: Failure to follow the Tx-5 or Tx-10 instructions above may result in the tip of the FlexiTrace becoming too hot to touch, resulting in risk of personal injury and damage to the equipment. The FlexiTrace can be used in two modes: Sonde mode or Line mode. In sonde mode only the tip of the FlexiTrace is energized whilst in line mode its whole length is energized. To use as a sonde, connect both transmitter leads to the FlexiTrace stud terminals. As the FlexiTrace terminals are not color coded it does not matter to which terminals the leads are connected. To use the FlexiTrace in line mode, connect the red transmitter lead to one of the FlexiTrace terminals and connect the black transmitter lead to a suitable ground connection. Figure 12.9: FlexiTrace 4 Repeat 1, 2 and 3 with the antenna vertical and resting on or just above the ground. The locator should then be directly above the sonde with the antenna in line with it. Mark the position of the sonde and its direction. 5 Propel the sonde a further 1 or 2 meters, pinpoint, and mark the position. Repeat this pinpoint procedure at similar intervals along the line of the drain or duct until the survey is completed. Checking sonde depth The RD7100 locator will automatically display the depth of a located sonde providing the locator is correctly oriented and positioned above the sonde. Using the LCD compass as a guide, rotate the locator until the compass indicates the sonde is in East / West position. 12.6 Stethoscopes When to use a stethoscope At times, it may not be possible to put a clamp around a cable because of congestion or because of inaccessibility. A stethoscope antenna should be used in place of a clamp to identify the target cable(s). Figure 12.8: Calculating sonde depth Calculation method Pinpoint the sonde. Move the locator in front of the sonde and still with the antenna in line with it, increase sensitivity to find the Peak of the ghost signal. Move the locator to behind the sonde ensuring that the locator

© 2019 Radiodetection Ltd 43

40mm 40mm 8mm How to use a stethoscope Plug the stethoscope into the locator accessory socket. Press the concave head against each cable in turn to detect a maximum signal. Stethoscope range Large stethoscope antenna The large stethoscope antenna, which plugs into the locator accessory socket, is used for cable identification in situations where the cable is exposed. It is particularly useful for identifying heavy cables lying in a tray where it is not possible to fit a clamp. The concave detector head on the end of the insulated, flexible gooseneck is placed firmly against the cable to be identified. If there are a number of cables, the stethoscope antenna will give the strongest response from the cable to which the transmitter signal has been applied. Small stethoscope antenna The small stethoscope antenna has a 25mm (2”) concave head at the end of a 2m (61⁄2 ft) lead. The small stethoscope can be screwed into an extension rod or used at the end of several extension rods joined together for identifying inaccessible small cables. Miniature hi-gain stethoscope The miniature stethoscope is similar to the small stethoscope but has no handle or facility for extension rods. The miniature stethoscope can also be used as a miniature antenna for locations where the bulk of the locator makes it inconvenient for use, such as locating pipes or cables in walls. 12.7 Submersible antenna When to use a submersible antenna Tracing buried pipes and cables across waterways and estuaries are frequent and critical locating applications. Less frequent but equally important is tracing and locating lines between the mainland and offshore islands. When locating pipes and cables the locator sensing antennas should be as close as possible to the target line so it is not practical to locate lines buried under a river or seabed from the surface. In most cases, it is necessary to measure the depth of cover to ensure the line is protected from dragging anchors or other underwater hazards. The submersible, double depth antenna is suitable for use under water for tracing pipes or cables. There is a weight at the bottom of the antenna for stability and the unit has been pressure tested to IP68 to a depth of 100m (300ft). The antenna is supplied with 10m of submersible marine umbilical cable as standard, but lengths of up to 100m can be supplied. The extra length enables the antenna to be carried by a diver on a riverbed or seabed while the locator is used in a surface vessel. It is crucial to have effective communication between the operator with the locator and the diver with the antenna. Alternatively the antenna can be fastened to the end of a non-metallic boom from a barge and lowered to the riverbed or seabed. How to use a submersible antenna Apply the transmitter signal to the target line at an access point on the shore. The submersible antenna line for tracing the line underwater is plugged into the accessory socket of the locator. The locator is used onboard a boat, which should by positioned directly over the line. The transmitting signal should be applied by Direct Connection with the strongest possible signal and at the frequency that the submersible antenna is calibrated to. Make a ground connection about 50m (160ft) from the transmitter. Test the quality of signal on the line before locating on the water. NOTE: The submersible antenna is calibrated to work at one frequency. Tips for using a submersible antenna: The user in the boat should be a specialist or have considerable experience using a locator so that they can give concise instructions to the diver. It is prudent for the pair to practice working together on dry land before attempting to locate underwater. Using the antenna the diver should locate and trace a known line blindfolded receiving directions from the user with the locator out of sight of the line and the diver. Because of rapid signal loss and a combination of large surface area and very conductive soil there may be problems applying a suitable signal for tracing a large diameter pipe. It may be necessary to use a high power, low frequency tracing signal. It is necessary to define a method of recording target line position and depth before starting work in the boat or on the seabed. Figure 12.10: Using a submersible antenna

© 2019 Radiodetection Ltd 44

Figure 12.12: Bracket positioning 8 Insert the mount bracket locating pins in the mounting holes at the back of the locator screen 9 Secure the rubber o-ring around either of the 2 fixing studs and loop it around the locator handle WARNING: Only properly licensed and experienced divers should attempt to use the submersible antenna. 12.8 Phone/Tablet mount Figure 12.13: Bracket secured 10 Stretch the other end of the rubber o-ring over the remaining fixing stud as for figure 12.13 rubber o-ring locating pins fixing stud fixing stud arm support ball arm support ball arm support ball arm support ball 11 Use the hand tightening bolts to loosen up the arm brackets and to attach it over the bracket’s arm support ball. 12 Add the phone or tablet holder mount bracket fixing stud

13 Tighten the hand tightening bolts to secure the mount 14 Position the phone or tablet to the front of the locator as shown in figure 8.x Figure 12.14: Phone/tablet correct position WARNING: Mobile phones or tablets may interfere with the locator’s performance if positioned not in front of the locator, see picture 12.14 Some mobile phone or tablets may affect the locator’s performance, even if used in the correct position. This may be obvious in situation where the locator is trying to detect a very small signal and it manifests itself by an When using a mobile device running a compatible application, such as RD Map for Android, you can use the Phone or Tablet mount to conveniently hold your device next to the locator and have immediate visual feedback on the survey measurement points you are marking. Figure 12.11: Phone/tablet mount kit To use the mobile device mount: © 2019 Radiodetection Ltd 45

tablet holder hand tightening bolts phone holder arm bracket

unstable signal shown on the bargraph and/or depth or current measurement. If in doubt remove the mobile phone or tablet to verify if these are affecting the behavior of the locator. No cables, such as power leads or headphones, must be connected to the phone or tablet when used with the mount kit. © 2019 Radiodetection Ltd 46

Section 13 - Appendices 13.1 Care and maintenance The RD7100 locator and transmitter are robust, durable and weatherproof. However you can extend your equipment’s life by following these care and maintenance guidelines. General Store the equipment in a clean and dry environment. Ensure all terminals and connection sockets are clean, free of debris and corrosion and are undamaged. Do not use this equipment when damaged or faulty. Batteries and power supply Use only good quality Alkaline or NiMH batteries. When using an AC adapter, use only Radiodetection approved adapters. Only use Radiodetection approved Li-Ion battery packs. Cleaning WARNING! Do not attempt to clean this equipment when it is powered or connected to any power source, including batteries, adapters and live cables. Ensure the equipment is clean and dry whenever possible. Clean with a soft, moistened cloth. If using this equipment in foul water systems or other areas where biological hazards may be present, use an appropriate disinfectant. Do not use abrasive materials or chemicals as they may damage the casing, including the reflective labels. Do not use high pressure hoses. Disassembly Do not attempt to disassemble this equipment under any circumstances. The locator and transmitter contain no user serviceable parts. Disassembly may damage the equipment and or reduce its performance and may void the manufacturer’s warranty. Service and maintenance The locator and transmitter are designed to minimize the requirement for regular calibration. However, as with all safety equipment, it is recommended (and may be required by law) that they are serviced at least once a year, either at Radiodetection or a Radiodetection- approved repair center. Regularly check your locator for correct operation using eCert (see section 10.6) and the on-board Self-Test. NOTE: Service by non-approved service centers or operators may void the manufacturer’s warranty. Radiodetection products, including this guide, are under continuous development and are subject to change without notice. Go to radiodetection.com or contact your local Radiodetection representative for the latest information regarding the RD7100 locator or any Radiodetection product. 13.2 Enhanced Self-Test RD7100 locators incorporate an Enhanced Self-Test feature. In addition to the typical checks for display and power functions, the RD7100 applies test signals to it’s locating circuitry during a Self-Test to check accuracy and performance. We recommend that a self-test is run at least weekly, or before each use. Running a Self-Test As the Self-Test tests the integrity of the locate circuity, it is important that it is carried out away from large metallic object such as vehicles, or strong electrical signals. To run a Self-Test: 1 Press the key to enter the menu 2 Scroll to the INFO menu using the or keys 3 Press the key to enter the INFO menu 4 Select TEST using the or keys. 5 Press the key to select YES 6 Press the key to begin the Self Test 7 Once the Self-Test is completed, the result (PASS or FAIL) will be displayed. 8. Restart the locator using the key

© 2019 Radiodetection Ltd 47 Radiodetection Calibration Certificate when a positive test result is obtained. To run eCert, the locator should be connected to an internet-enabled PC, on which the RD Manager software is installed. Additional eCert credits may be required and purchased. Refer to the RD Manager operation manual for further details. NOTE: eCert is not presently available for transmitters. 13.6 Time and date error messages RD7100 usage logging models feature an internal clock which is used to time and date survey measurements, the 1/second internal logging and for the CALSafe feature. Every time the locator is switched on, it performs a check to verify its correct operation. In the unlikely event of an issue with this clock the system will emit a warning audio tone and display the word ERROR, followed by a 3 digit error code. Make a note of this code and contact your nearest service center or Radiodetection representative. 13.7 RF Markers The RD7000+ Marker is compatible with any RF marker tuned to the frequency shown in the table below: Utility Color Frequency French Power Natural 40.0kHz General / Non- drinkable water 13.3 RD ManagerTM RD Manager is the RD7100 Locator PC companion and allows you to manage and customize your locator. It also allows software upgrades to both the locator and transmitter. You can use RD Manager to register your products to extend the warranty to a total of 3 years (see Section 10.4), setup your locator by performing a number of maintenance tasks, such as setting date and time, activating and de-activating active frequencies, setting up custom frequencies, or setting-up functions like CALSafe or StrikeAlert. RD Manager is also used to retrieve and analyze internal logged data (logging models only). RD Manager is compatible PCs running with Microsoft Windows XP, Windows 7, Windows 8 and Windows 8.1. For more information about RD Manager refer to the RD Manager operation manual. To Obtain RD Manager: 1 Go to radiodetection.com/RDManager 2 Follow the instructions 13.4 Upgrading software From time to time, Radiodetection may release software upgrades to enhance features and improve performance of the RD7100 locator or transmitter. Software upgrades are free of charge. You can check if your products are up-to-date or upgrade them by using the RD Manager software upgrade screen. Refer to the RD Manager operation manual for further information. E-mail alerts and notification of new software releases are sent to all registered users. NOTE: To upgrade your software you need to have created an account using RD Manager and have a live internet connection. An optional Radiodetection supplied power source may be required to update your transmitter software. 13.5 eCert The RD7100 locator should be regularly checked to ensure its correct operation. eCert provides a thorough test of the RD7100’s locating circuitry and marker transceiver, and supplies a Purple 66.35kHz Cable TV Black/Orange 77.0kHz Gas Yellow 83.0kHz Telephone/Telecom s Orange 101.4kHz Sanitary Green 121.6kHz German Power Blue/Red 134.0kHz Water Blue 145.7kHz Electrical Power* Red 169.8kHz *Use of the red Electrical Power (PWR) marker locate mode is subject to radio licensing restrictions for Short Range Devices in the EU and possibly other countries. It is the responsibility of the user to ensure that the red Power (PWR) marker locate mode is only enabled in countries where radio licensing restrictions do not apply at the operating frequency of 169kHz. © 2019 Radiodetection Ltd 48 13.8 Supported Accessories Locator Accessories High Gain Stethoscope 10/RX-STETHOSCOPE-HG Small Stethoscope 10/RX-STETHOSCOPE-S Large Stethoscope 10/RX-STETHOSCOPE-L 640Hz Submersible DD Antenna (10m Cable) 10/RX-SUBANTENNA-640 8kHz Submersible DD Antenna (10m Cable) 10/RX-SUBANTENNA-8K 512Hz Submersible DD Antenna (10m Cable) 10/RX-SUBANTENNA-512 Additional Submersible Cable Length (Per Metre) 10/RX-SUBANTENNA-CABLE Submersible Antenna Adaptor 10/RX-SUBANTENNA- ADAPTOR Headphones 10/RX-HEADPHONES A-Frame (includes A-Frame Lead) 10/RX-AFRAME A-Frame Bag 10/RX-AFRAME-BAG A-Frame Lead 10/RX-AFRAME-LEAD 2" (50mm) Locator Clamp 10/RX-CLAMP-50 © 2019 Radiodetection Ltd 49 4" (100mm) Locator Clamp 10/RX-CLAMP-100 5" (130mm) Locator Clamp 10/RX-CLAMP-130 Locator CD/CM Clamp (only used for Current Measurement) 10/RX-CD-CLAMP Locator mobile phone holder - complete kit 10/RX-PHONE-HOLDER-K Locator tablet holder - complete kit 10/RX-TABLET-7-8-HOLDER- K Mobile device support bracket and arm 10/RX-HOLDER-MOUNT Mobile phone holder 10/RX-PHONE-HOLDER 7"-8" tablet holder 10/RX-TABLET-7-8-HOLDER Bracket adapter for RAM mounts 10/RX-RAM-ADPT Bracket O-ring set for mobile devise holder (spare set of 2 O-rings) 10/RX-RAM-ADPT-ORING © 2019 Radiodetection Ltd 50 Transmitter Accessories Live Plug Connector 10/TX-LPC-XX (XX= EU, UK, US) Live Cable Connector (with Crocodile clips) 10/TX-LCC 2" (50mm) Transmitter Clamp 10/TX-CLAMP-50 4" (100mm) Transmitter Clamp 10/TX-CLAMP-100 5" (130mm) Transmitter Clamp 10/TX-CLAMP-130 8.5” (215mm) Transmitter Clamp 10/TX-CLAMP-215 Signal Clamp Extension Rod 10/TX-CLAMP-EXTROD Transmitter Connection Kit Contains Earth Reel, Earth Stake, Direct Connection Lead and Magnet 10/TX-CONNECTION-KIT Transmitter Connection Kit Contains Earth Reel, Earth Stake, Direct Connection Lead with banana connectors and Magnet 10/TX-CONNECTION-KIT-BAN Earth Lead 10m and Magnet 10/TX-EARTHLEAD-KIT Earth Lead 10m 10/TX-EARTHLEAD Hi-strength Magnet with M4 eyebolt 10/TX-MAGNET Spiral Earth Stake 10/TX-EARTHSTAKE Tx Direct Connection Lead 10/TX-DC-LEAD © 2019 Radiodetection Ltd 51 Tx Direct Connection Lead, crocodile clip 10/TX-DC-LEAD-TEL Tx Direct Connection Lead with banana connectors, insulated plug/socket 10/TX-DC-LEAD-BAN Tx Direct Connection Lead with banana connectors, Open Grid Europe 10/TX-DC-LEAD-OPEN

Tx-10 Isolation Transformer (for locating 3-phase core-core shorts) 10/TX121-XX (XX= DE, EN, FR, NL) Accessories for tracing or locating non-conductive utilities

Standard Sonde 33kHz, depth up to 5m 10/SONDE-STD-33 Standard Sonde 8kHz, depth up to 5m 10/SONDE-STD-8 Standard Sonde 512Hz, depth up to 5m, single end 10/SONDE-STD-512 Standard Sonde 512Hz, depth up to 5m, twin end 10/SONDE-STD-512-TW Sewer Sonde 33kHz, depth up to 8m 10/SONDE-SEWER-33 External Shell for heavy-duty Applications (dia. as Sewer Sonde) 10/SONDE-SEWER-SHELL Super Sonde 33kHz, depth up to 15m 10/SONDE-SUPER-33

4.5" (115mm) Diameter Floats/Pair for Sewer and Super Sondes 10/SONDE-FLOATS

S6 Microsonde Kit, incl. battery and case 10/SONDE-MICRO-33 © 2019 Radiodetection Ltd 52 Pack of 10 × Batteries for S6 Microsonde 10/SONDE-MICRO- BATPACK S9 MiniSonde, incl. battery and case 10/SONDE-MINI-33 Pack of 10 × Batteries for S9 MiniSonde 10/SONDE-MINI-BATPACK S13 Sonde Kit (includes M10 Stud and Plain End Caps, two Batteries and Case) 10/SONDE-S13-33 Pack of ten spare Batteries for S13 Sonde 10/SONDE-S13-BATPACK S18A Sonde 33kHz with M10 Stud End Cap and one D1/3N battery 10/SONDE-S18A-33 S18A Sonde 33kHz Kit with M10 Stud and Plain End Caps and two D1/3N Batteries 10/S18-33-KIT S18A M10 Stud End Cap with one D1/3N Battery 10/S18-M10-ENDCAP S18A Extended Plain Cap with one D1/3N Battery 10/S18-PLAINENDCAP S18A Pack of 5 D1/3N Batteries 10/S18-BATTERYPACK S18B Sonde 33kHz with Extended Aluminum End Cap for two AA Batteries (batteries included) 10/SONDE-S18B-33 S18B Sonde Aluminum AA Batteries End Cap (batteries included) 10/S18-AA-ENDCAP Bendi Sonde with M10 Male End Cap (512Hz continuous) 10/SONDE-BENDI-512 Pack of 5 AA Batteries 10/SONDE-BENDI- BATPACK FlexiTrace 50m (Tx powered pushrod transmitter) 10/TRACE50-XX © 2019 Radiodetection Ltd 53 FlexiTrace 80m (Tx powered pushrod transmitter) 10/TRACE80-XX (XX = D, F, GB, NL) 4.5mm 50m Flexrod 10/TRACE50-XX (XX = D, F, GB, NL) 4.5mm 80m Flexrod 10/TRACE80-XX (XX = D, F, GB, NL) 6.7mm 50m Flexrod 10/FLEXRODF50-4.5 6.7mm 100m Flexrod 10/FLEXRODF80-4.5 6.7mm 150m Flexrod 10/FLEXRODF50-7 9mm 60m Flexrod 10/FLEXRODF60-9 9mm 120m Flexrod 10/FLEXRODF120-9 M6 to M10 adapter to interface 6.7mm rod with RD M10 thread 10/6- 10FLEXRODADAPTOR Spring Coupling M10 Male 10/SU0335 Wards Rod Connector, 3/4" (19mm) x 10 BSW, Female 02/SU0341 Wards Rod Connector, 1/2" (13mm) x 12 BSW, Female 02/SU0342 "Lockfast" Connector, 3/4" (19mm) x 10 BSW 02/SU0676 © 2019 Radiodetection Ltd 54 RF Marker Balls (box of 30) Purple - General / Non-potable Water - 66.35kHz 61/OMGENERAL Black/Orange - Cable TV - 77.0kHz 61/OMCABLE Yellow - Gas - 83.0kHz 61/OMGAS Orange - Telephone / Telecoms - 101.4kHz 61/OMTEL Green - Sanitary - 121.6kHz 61/OMSANITARY Blue - Water - 145.7kHz 61/OMWATER Red - Electrical Power - 169.8kHz 61/OMPOWER Locator power accessories and spares Li-Ion rechargeable battery pack with mains charger (includes power lead) (1) 10/RX-MBATPACK-LION-K-XX Li-Ion rechargeable battery pack with auto charger (1) 10/RX-ABATPACK-LION-K Li-Ion rechargeable battery pack with mains and automotive charger (includes power lead) (1) 10/RX-MABATPACK-LION-K- XX 3 cells battery tray (3x D Cell / LR20) (1) - Marker Locator only 10/RX-MARKER-3DCELL- TRAY 2 cells battery tray (2x D Cell / LR20) (2) 10/RX-2DCELL-TRAY (1) Compatible with the RD7100/RD8100 and Marker (MRX) Locators (2) Compatible with the RD7100/RD8100 and RD7000+/RD8000 Locators © 2019 Radiodetection Ltd 55 D Cell batteries Alkaline Battery (D-Cell, LR20, MN1300) 10/1DCELL-ALK Mains Leads C7 Mains lead, 6.5' (2m), 2.5A 10/MAINS-LEAD-C7-XX C13 Mains lead, 6.5' (2m), 2.5A 10/MAINS-LEAD-C13-XX (XX=US, UK, EU or AU) Transport and Storage Accessories Soft Carry Bag 10/LOCATORBAG Hard Flight Case with wheels 10/RD7K8KCASE Calibration Certificates, Remote Calibration and PC Software Locator Calibration Certificate, per unit (requestable with initial locator order, cannot be ordered later) 10/CALCERT eCALTM Calibration Certificate Verification Key for RD7000+/RD8000 (non-marker models) 10/RD7K8KECAL eCertTM Calibration Credit for RD7100 and RD8100 locators 10/ECERT-RD71/RD81 eCertTM Calibration Credit for Marker locators 10/ECERT-MARKERS RD Manager Check product documentation for details radiodetection.com/rdmanager RD Manager CD with latest version 97/RDMANAGER © 2019 Radiodetection Ltd 56 Visit radiodetection.com Global locations Radiodetection (USA) 28 Tower Road, Raymond, Maine 04071, USA Toll Free: +1 (877) 247 3797 Tel: +1 (207) 655 8525 rd.sales.us@spx.com Pearpoint (USA) 39-740 Garand Lane, Unit B, Palm Desert, CA 92211, USA Toll Free: +1 800 688 8094 Tel: +1 760 343 7350 pearpoint.sales.us@spx.com pearpoint.com Schonstedt Instrument Company (USA) 100 Edmond Road, Kearneysville, WV 25430 USA Toll Free: +1 888 367 7014 Tel: +1 304 724 4722 schonstedt.info@spx.com Radiodetection (Canada) 344 Edgeley Boulevard, Unit 34, Concord, Ontario L4K 4B7, Canada Toll Free: +1 (800) 665 7953 Tel: +1 (905) 660 9995 rd.sales.ca@spx.com Radiodetection Ltd. (UK) Western Drive, Bristol, BS14 0AF, UK Tel: +44 (0) 117 976 7776 rd.sales.uk@spx.com Radiodetection (France) 13 Grande Rue, 76220, Neuf Marché, France Tel: +33 (0) 2 32 89 93 60 rd.sales.fr@spx.com Radiodetection (Benelux) Industriestraat 11, 7041 GD ’s-Heerenberg, Netherlands Tel: +31 (0) 314 66 47 00 rd.sales.nl@spx.com Radiodetection (Germany) Groendahlscher Weg 118, 46446 Emmerich am Rhein, Germany Tel: +49 (0) 28 51 92 37 20 rd.sales.de@spx.com Radiodetection (Asia-Pacific) Room 708, CC Wu Building, 302-308 Hennessy Road, Wan Chai, Hong Kong SAR, China Tel: +852 2110 8160 rd.sales.asiapacific@spx.com Radiodetection (China) 13 Fuqianyi Street, Minghao Building D304, Tianzhu Town, Shunyi District, Beijing 101312, China Tel: +86 (0) 10 8146 3372 rd.service.cn@spx.com Radiodetection (Australia) Unit H1, 101 Rookwood Road, Yagoona NSW 2199, Australia Tel: +61 (0) 2 9707 3222 rd.sales.au@spx.com Copyright © 2019 Radiodetection Ltd. All rights reserved. Radiodetection is a subsidiary of SPX Corporation. Radiodetection, and RD7100 are registered trademarks of Radiodetection in the United States and/or other countries. Trademarks and Notices. The following are trademarks of Radiodetection: RD7100, eCert, TruDepth, RD Manager, RD Map, Peak+, Power Filters, StrikeAlert, CALSafe. The design of the RD7100 locators and transmitters has been registered. The design of the 4 chevrons has been registered. RAM is a trademark of National Products Inc. Due to a policy of continued development, we reserve the right to alter or amend any published specification without notice. This document may not be copied, reproduced, transmitted, modified or used, in whole or in part, without the prior written consent of Radiodetection Ltd.