Free English PANASONIC LS-H22 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD PANASONIC LS-H22 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.


How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.


What safety precautions should be followed when using the PANASONIC LS-H22?

Never use the PANASONIC LS-H22 as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products which meet standards, such as OSHA, ANSI or IEC for personnel protection applicable in each region or country. Do not view the direct beam by the unprotected eye or with an optical instrument, as lasers are potentially hazardous. Use of control or adjustment or performance of procedures other than those specified in this instruction may result in hazardous radiation exposure.


What is the laser classification of the PANASONIC LS-H22?

The PANASONIC LS-H22 is classified as a Class 2 laser product according to IEC 60825-1-2014 and JIS C 6802-2014.


What are the technical specifications for the PANASONIC LS-H22 emitting element?

The emitting element of the PANASONIC LS-H22 is a red semiconductor laser, Class 2 (IEC/JIS/GB/KS standard), with a maximum output of 3mW or less and a peak emission wavelength of 655nm.


What are the ambient temperature and humidity operating ranges for the PANASONIC LS-H22?

The operating ambient temperature for the PANASONIC LS-H22 is -10 to +55 degrees Celsius, with no dew condensation or icing allowed. The storage temperature range is -20 to +70 degrees Celsius. The operating and storage ambient humidity is 35 to 85 percent RH.


What material is used for the enclosure of the PANASONIC LS-H22?

The enclosure of the PANASONIC LS-H22 is made of PBT, with an attachment made of PEI and a lens cover made of acrylic.


What is the cable specification for the PANASONIC LS-H22?

The PANASONIC LS-H22 uses a 0.1mm squared cable that is shielded and 2 meters long.


What sensing range options are available for the PANASONIC LS-H22 depending on the mode?

The sensing range for the PANASONIC LS-H22 (long sensing range line reflective type) is as follows: H-SP mode is 30 to 300mm; FAST mode is 30 to 300mm; STD mode is 30 to 500mm; U-LG mode is 30 to 1,000mm.


What is the approximate weight of the PANASONIC LS-H22?

The PANASONIC LS-H22 has an approximate weight of 30 grams.


Are there any restrictions on the amplifier used with the PANASONIC LS-H22?

The PANASONIC LS-H22 must be used with an optional exclusive amplifier from the LS-400 series. Using a different amplifier may cause the specifications to not be met, and may cause malfunction or breakdown.


What should be considered regarding ground connections when using the PANASONIC LS-H22?

If noise generating equipment, such as a switching regulator or an inverter motor, is used in the vicinity of the PANASONIC LS-H22, connect the frame ground (F.G.) terminal of the equipment to an actual ground. Similarly, if power is supplied from a commercial switching regulator, ensure the F.G. terminal of the power supply is connected to an actual ground.


Can the cable of the PANASONIC LS-H22 be extended?

No, the sensor head cable of the PANASONIC LS-H22 cannot be extended.


What should I do if dust or dirt gets on the lens of the PANASONIC LS-H22?

Do not allow water, oil, fingerprints, or other substances that might refract light, or dust, dirt, or other substances that might block light, to stick to the emitting or receiving surfaces of the PANASONIC LS-H22. If they are present, wipe them off with a clean, soft cloth or lens paper.


What conditions should be avoided when operating the PANASONIC LS-H22?

Do not use the PANASONIC LS-H22 in vaporous, dusty, or corrosive gas atmospheres. Ensure the power is off while cleaning the emitting or receiving windows of the sensor head.


How should the PANASONIC LS-H22 be mounted?

The tightening torque for mounting the PANASONIC LS-H22 should be 0.5N・m or less.


How do I adjust the spot size on the PANASONIC LS-H22?

The PANASONIC LS-H22 incorporates a spot-size adjuster. Turn the spot-size adjuster clockwise or counterclockwise to adjust the spot diameter to your desired detecting distance. Note that if the adjuster is over turned, it may be damaged.


How is the lens attachment (LS-MR1) removed from the PANASONIC LS-H22?

To remove the lens attachment (LS-MR1) from the PANASONIC LS-H22, insert a screwdriver into the fixing slot located at the top of the sensor. Tilt the screwdriver inserted in the slot to remove the lens attachment.


What should I check before using the PANASONIC LS-H22 with the LS-MR1 attachment?

The size of the upper fixing hook of the LS-MR1 is not the same as the lower fixing hook. After confirming the upper and lower fixing hooks, insert the LS-MR1 upper fixing hook into the fixing slot at the top of the PANASONIC LS-H22 sensor and then insert the LS-MR1 lower fixing hook into the fixing slot at the bottom of the sensor. After mounting, check that the LS-MR1 is properly fixed.


What is the proper procedure for shortening the cable of the PANASONIC LS-H22?

The cable of the PANASONIC LS-H22 can be shortened to your desired length. Use a flat-head screwdriver (blade width 2mm or less) to push the operating lever (white) located at the wire inlet to remove the wire. After shortening, re-wire according to the connection procedure.


How do I connect the wires for the PANASONIC LS-H22 to the connector?

First, process the core length to 7 to 8 mm as indicated by the strip gauge on the side of the unit, and twist the core several times. When using shielded wires, twist the wire until the diameter is 1.2 mm or less. Use a flat-head screwdriver (2mm or less) to push the operating lever (white) located at the operating area until it is locked. Insert the wire into the innermost part of the wire inlet, ensuring the shielded wire is properly inserted and the core end has passed through the wire connection area. Place the head of a flat-head screwdriver underneath the operating lever through the releasing slot and lift the screwdriver head. If you hear a snap, the operating lever is returned and the wire is fixed. Lightly pull the wire to ensure it is not loose and check that shielded wires do not contact each other.


What are the wire color assignments for the PANASONIC LS-H22 terminal connections?

The terminal connections for the PANASONIC LS-H22 are as follows:

Terminal 1: Conductive core, Brown

Terminal 2: Shielded wire, Gray

Terminal 3: Conductive core, Yellow

Terminal 4: Shielded wire, Black


What happens if the PANASONIC LS-H22 sensor head is exposed to rapid-starter fluorescent lamps?

The PANASONIC LS-H22 sensor head should not be directly exposed to a fluorescent lamp from a rapid-starter lamp or a high frequency lighting device, as this may affect the sensing performance.


Does the PANASONIC LS-H22 require any specific setup after power-on?

Do not use the PANASONIC LS-H22 during the initial transient time, which is 0.5 seconds just after the power supply is switched on.


Can I run the wires for the PANASONIC LS-H22 in the same raceway as high-voltage lines?

No, do not run the wires for the PANASONIC LS-H22 together with high-voltage lines or power lines, or put them in the same raceway. This can cause malfunction due to induction.


What should I be careful about regarding the PANASONIC LS-H22 cable joint?

Make sure that no stress is applied to the sensor head cable joint of the PANASONIC LS-H22.


Is the PANASONIC LS-H22 suitable for outdoor use?

No, the PANASONIC LS-H22 is suitable for indoor use only.


What should I avoid contact with when using the PANASONIC LS-H22?

Take care that the PANASONIC LS-H22 does not come in contact with water, oil, grease, or organic solvents, such as thinner.


Is the laser emission indicator visible on the PANASONIC LS-H22?

Yes, while the laser is emitted, the green laser emission indicator on the PANASONIC LS-H22 lights up. This indicator is visible even when wearing laser protective glasses.


What should I do if the label on the PANASONIC LS-H22 is not visible after installation?

If the affixed label on the PANASONIC LS-H22 might not be visible after installation, affix the accessory label close to the product where it can be seen.


How do I verify the PANASONIC LS-H22 is receiving power?

The PANASONIC LS-H22 features an orange operation indicator LED which lights up when the amplifier output is ON.


Does the PANASONIC LS-H22 come with CE Marking?

The models listed under the “SPECIFICATIONS” section of the document, which includes the PANASONIC LS-H22, come with CE Marking.


Is it possible to damage the PANASONIC LS-H22 by applying bending force to the lens attachment?

Yes, do not apply any excessive bending force to the lens attachment (LS-MR1) used with the PANASONIC LS-H22, as such force may cause damage.


How can I clean the lens attachment (LS-MR1) for the PANASONIC LS-H22?

Keep the lens of the PANASONIC LS-H22 attachment free from dust, dirt, water, oil, grease, etc., to maintain performance.


What is the function of the screwdriver when releasing wires from the PANASONIC LS-H22?

When releasing wires from the PANASONIC LS-H22, use a flat-head screwdriver with a blade width of 2mm or less to push the white operating lever located at the wire inlet to release the wire.


What is the correct core length for wiring the PANASONIC LS-H22?

The core length for wiring the PANASONIC LS-H22 should be 7 to 8 mm.


How should I prepare shielded wires for the PANASONIC LS-H22?

When using shielded wires for the PANASONIC LS-H22, twist the wire until obtaining a diameter of 1.2 mm or less before inserting it into the wire inlet.


How do I know the wire for the PANASONIC LS-H22 is locked in the connector?

After inserting the wire into the PANASONIC LS-H22 connector and lifting the operating lever using a flathead screwdriver in the releasing slot, you should hear a snap, which indicates the operating lever is returned and the wire is fixed.


How do I verify the wire is not loose after connecting it to the PANASONIC LS-H22?

After finishing the wiring procedure for the PANASONIC LS-H22, lightly pull the wire to ensure that it is not loose.


What is the required power status for cleaning the PANASONIC LS-H22?

Make sure that the power is off while cleaning the emitting or receiving windows of the PANASONIC LS-H22 sensor head.


Can the lens attachment (LS-MR1) be used with other models besides the PANASONIC LS-H22?

The lens attachment (LS-MR1) is specifically used with the PANASONIC LS-H22 and can also be attached to the LS-H21 to obtain performance equivalent to the PANASONIC LS-H22.


What type of screw should be used to mount the PANASONIC LS-H22?

An M3 screw (length 12 mm) with washers should be used for mounting the PANASONIC LS-H22 to a sensor bracket.


What must be checked regarding the PANASONIC LS-H22 setup after power-on?

Do not use the PANASONIC LS-H22 during the initial transient time (0.5 seconds) just after the power supply is switched on.


How should the PANASONIC LS-H22 emitting/receiving surfaces be maintained?

Do not allow water, oil, or dust to stick to the emitting/receiving surfaces of the PANASONIC LS-H22. If they are present, wipe them off with a clean, soft cloth or lens paper.


Are there special considerations for using the PANASONIC LS-H22 in areas with noise?

If noise-generating equipment such as a switching regulator or inverter motor is used near the PANASONIC LS-H22, connect the frame ground (F.G.) terminal of the equipment to an actual ground to prevent issues.


How should the PANASONIC LS-H22 sensor cable be handled?

Ensure that no stress is applied to the PANASONIC LS-H22 sensor head cable joint. Do not run wires with high-voltage lines to avoid induction-related malfunctions.


What is the purpose of the operation indicator on the PANASONIC LS-H22?

The orange LED operation indicator on the PANASONIC LS-H22 lights up when the amplifier output is ON.


How do I perform the wiring for the PANASONIC LS-H22 terminal number 2?

Terminal number 2 of the PANASONIC LS-H22 is used for the shielded wire, which should be gray in color.


How do I perform the wiring for the PANASONIC LS-H22 terminal number 4?

Terminal number 4 of the PANASONIC LS-H22 is used for the shielded wire, which should be black in color.


What is the core color for terminal number 1 on the PANASONIC LS-H22?

Terminal number 1 of the PANASONIC LS-H22 is for the conductive core, which is brown in color.


What is the core color for terminal number 3 on the PANASONIC LS-H22?

Terminal number 3 of the PANASONIC LS-H22 is for the conductive core, which is yellow in color.


What if the PANASONIC LS-H22 emits a laser but the indicator is off?

The PANASONIC LS-H22 laser emission indicator (green LED) should light up while the laser is being emitted. If it does not, you should check your connections or contact support as described for the PANASONIC LS-H22.


What must be ensured when using the PANASONIC LS-H22 for industrial use?

The PANASONIC LS-H22 has been developed and produced for industrial use only, and must be used with the connector joined to the exclusive amplifier.


Is the PANASONIC LS-H22 designed to be safe for eyes?

The PANASONIC LS-H22 is a Class 2 laser product. It uses a visible, low-power beam. Blink response of the eye generally affords protection, but do not view the beam directly.


How should the PANASONIC LS-H22 be handled while wiring?

Make sure that the power is off while wiring the PANASONIC LS-H22 to the amplifier.


What happens to the PANASONIC LS-H22 if the lens attachment is incorrectly mounted?

Mounting the lens attachment incorrectly on the PANASONIC LS-H22 might cause performance issues or damage to the attachment. Always confirm that the upper and lower fixing hooks are correctly inserted into their respective slots.


Can the PANASONIC LS-H22 be used with a commercial switching regulator?

Yes, but if the power for the PANASONIC LS-H22 is supplied from a commercial switching regulator, ensure the frame ground (F.G.) terminal of the power supply is connected to an actual ground.


What is the operating voltage requirement for the PANASONIC LS-H22?

The operating voltage is handled by the amplifier in the LS-400 series to which the PANASONIC LS-H22 is connected.


CLICK HERE TO DOWNLOAD PANASONIC LS-H22 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.