What is the recommended procedure to check for gas leakage after installing or servicing the PANASONIC CS-E10JD3EA Air Conditioner?
After completing installation or service on the PANASONIC CS-E10JD3EA Air Conditioner, confirm that there is no leakage of refrigerant gas. If refrigerant gas contacts fire, it may generate toxic gas.
What are the safety precautions regarding electrical work for the PANASONIC CS-E10JD3EA Air Conditioner?
Electrical work for the PANASONIC CS-E10JD3EA Air Conditioner must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed.
What is the required torque for tightening the flare nut when connecting the piping to the outdoor unit of the PANASONIC CS-E10JD3EA Air Conditioner?
When connecting the piping to the outdoor unit for the PANASONIC CS-E10JD3EA Air Conditioner:
The torque for tightening the flare nut is:
| Model | Piping size | Torque (Gas) | Torque (Liquid) |
|---|---|---|---|
| E10**** | 3/8″ | 42 N m | 1/4″ (18 N m) |
What is the procedure for evacuating the air inside the indoor unit and pipes for the PANASONIC CS-E10JD3EA Air Conditioner (for Europe & Oceania destination)?
The procedure for evacuating the equipment for the PANASONIC CS-E10JD3EA Air Conditioner is as follows:
1. Connect a charging hose with a push pin to the Low and High side of a charging set and the service port of the 3-way valve. Be sure to connect the end of the charging hose with the push pin to the service port.
2. Connect the center hose of the charging set to a vacuum pump with check valve, or vacuum pump and vacuum pump adaptor.
3. Turn on the power switch of the vacuum pump and make sure that the needle in the gauge moves from 0 cmHg (0 MPa) to -76 cmHg (-0.1 MPa). Then evacuate the air approximately ten minutes.
4. Close the valve of the charging set and turn off the vacuum pump. Make sure that the needle in the gauge does not move after approximately five minutes.
5. Disconnect the charging hose from the vacuum pump and from the service port of the 3-way valve.
6. Tighten the service port caps of both of the 3-way valve at a torque of 18 N m with a torque wrench.
7. Remove the valve caps of both of the 2-way valve and 3-way valve. Position both of the valves to OPEN using a hexagonal wrench (4 mm).
8. Mount valve caps onto the 2-way valve and the 3-way valve.
What is the required torque for tightening the flare nut when connecting the piping to the indoor unit for the PANASONIC CS-E10JD3EA Air Conditioner?
When connecting the piping to the indoor unit for the PANASONIC CS-E10JD3EA Air Conditioner:
The torque for tightening the flare nut is:
| Model | Piping size (Torque) | Gas | Liquid |
|---|---|---|---|
| E10**** | 3/8″ | 42 N m | 1/4″ (18 N m) |
How does the PANASONIC CS-E10JD3EA Air Conditioner handle auto restart after a power failure?
The PANASONIC CS-E10JD3EA Air Conditioner features random auto restart after power failure for safety restart operation. When the power supply is cut off during operation, the compressor will re-operate within three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after power supply resumes.
What are the conditions for the compressor to stop under Thermostat control during Cooling Operation for the PANASONIC CS-E10JD3EA Air Conditioner?
Under Thermostat control during Cooling Operation for the PANASONIC CS-E10JD3EA Air Conditioner:
- Compressor is OFF when Intake Air Temperature – Internal Setting Temperature is less than -1.5°C.
What are the conditions for the compressor to turn ON under Thermostat control during Cooling Operation for the PANASONIC CS-E10JD3EA Air Conditioner?
Under Thermostat control during Cooling Operation for the PANASONIC CS-E10JD3EA Air Conditioner:
- Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature – Internal Setting Temperature is greater than Compressor OFF point.
What are the conditions for the compressor to stop under Thermostat control during Soft Dry Operation for the PANASONIC CS-E10JD3EA Air Conditioner?
Under Thermostat control during Soft Dry Operation for the PANASONIC CS-E10JD3EA Air Conditioner:
- Compressor is OFF when Intake Air Temperature – Internal Setting Temperature is less than -2.0°C.
What are the conditions for the compressor to turn ON under Thermostat control during Soft Dry Operation for the PANASONIC CS-E10JD3EA Air Conditioner?
Under Thermostat control during Soft Dry Operation for the PANASONIC CS-E10JD3EA Air Conditioner:
- Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature – Internal Setting Temperature is greater than Compressor OFF point.
What are the conditions for the compressor to stop under Thermostat control during Heating Operation for the PANASONIC CS-E10JD3EA Air Conditioner?
Under Thermostat control during Heating Operation for the PANASONIC CS-E10JD3EA Air Conditioner:
- Compressor is OFF when Intake Air Temperature – Internal Setting Temperate is greater than +2.0°C.
What are the conditions for the compressor to turn ON under Thermostat control during Heating Operation for the PANASONIC CS-E10JD3EA Air Conditioner?
Under Thermostat control during Heating Operation for the PANASONIC CS-E10JD3EA Air Conditioner:
- Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature – Internal Setting Temperature is less than Compressor OFF point.
What is the condition for Quiet operation to stop when using the PANASONIC CS-E10JD3EA Air Conditioner in Cooling/Soft Dry Mode?
Quiet operation stops on the PANASONIC CS-E10JD3EA Air Conditioner in Cooling/Soft Dry Mode when one of the following conditions is satisfied:
1. Powerful button is pressed.
2. Stop by OFF/ON switch.
3. Timer off activates.
4. Quiet button is pressed again.
What are the control contents for Quiet operation in Cooling/Dry Mode for the PANASONIC CS-E10JD3EA Air Conditioner?
The control contents for Quiet operation in Cooling/Dry Mode for the PANASONIC CS-E10JD3EA Air Conditioner are:
1. Auto fan speed is changed from normal setting to quiet setting of respective fan speed. This is to reduce sound of Hi, Me, Lo for 3dB.
2. Manual fan speed for quiet operation is 1 step from setting fan speed.
3. Outdoor fan speed is changed to Q-Lo.
4. Compressor frequency reduced.
What is the condition for Quiet operation to stop when using the PANASONIC CS-E10JD3EA Air Conditioner in Heating Mode?
Quiet operation stops on the PANASONIC CS-E10JD3EA Air Conditioner in Heating Mode when one of the following conditions is satisfied:
1. Powerful button is pressed.
2. Stop by OFF/ON switch.
3. Timer off activates.
4. Quiet button is pressed again.
What are the control contents for Quiet operation in Heating Mode for the PANASONIC CS-E10JD3EA Air Conditioner?
The control contents for Quiet operation in Heating Mode for the PANASONIC CS-E10JD3EA Air Conditioner are:
a. Fan Speed Auto: Indoor FM RPM depends on pipe temperature sensor of indoor heat exchanger. Auto fan speed is changed from normal setting to quiet setting of respective fan speed. This is to reduce sound of Hi, Me, Lo for 3dB.
b. Fan Speed Manual: Manual fan speed for quiet operation is – 1 step from setting fan speed.
c. Compressor frequency reduced.
How does the Powerful Mode Operation work on the PANASONIC CS-E10JD3EA Air Conditioner?
When the powerful mode is selected on the PANASONIC CS-E10JD3EA Air Conditioner, the internal setting temperature will shift higher up to 3.5°C (for Heating) or lower up to 2°C (for Cooling/Soft Dry) than remote control setting temperature for 20 minutes to achieve the setting temperature quickly.
What happens when the ON Timer is set for the PANASONIC CS-E10JD3EA Air Conditioner?
When the ON Timer is set using the remote control for the PANASONIC CS-E10JD3EA Air Conditioner, the unit with the timer set will start operating earlier than the setting time to provide a comfortable environment when reaching the set ON time. 60 minutes before the set time, the indoor fan motor (at fan speed of Lo-) and outdoor fan motor start operating for 30 seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting time.
What happens when the OFF Timer is set for the PANASONIC CS-E10JD3EA Air Conditioner?
When the OFF Timer is set using the remote control for the PANASONIC CS-E10JD3EA Air Conditioner, the unit will stop operating at the set time.
What is the Restart Control (Time Delay Safety Control) protection for all operations on the PANASONIC CS-E10JD3EA Air Conditioner?
The Restart Control (Time Delay Safety Control) for all operations on the PANASONIC CS-E10JD3EA Air Conditioner is:
The Compressor will not turn on within 3 minutes from the moment operation stops, although the unit is turned on again by pressing the OFF/ON button at the remote control within this period. This control is not applicable if the power supply is cut off and on again. This phenomenon is to balance the pressure inside the refrigerant cycle.
What is the 30 Seconds Forced Operation protection for all operations on the PANASONIC CS-E10JD3EA Air Conditioner?
The 30 Seconds Forced Operation protection on the PANASONIC CS-E10JD3EA Air Conditioner means that once the air conditioner is turned on, the compressor will not stop within 30 seconds in a normal operation although the intake air temperature has reached the thermo-off temperature. However, force stop by pressing the OFF/ON button at the remote control is permitted or the Auto OFF/ON button at the indoor unit. The reason is to allow the refrigerant oil run in a full cycle and return back to the outdoor unit.
How is the Total Running Current Control implemented for the outdoor unit of the PANASONIC CS-E10JD3EA Air Conditioner?
The Total Running Current Control for the outdoor unit of the PANASONIC CS-E10JD3EA Air Conditioner is implemented as follows:
1. When the outdoor unit total running current (AC) exceeds X value, the frequency instructed for compressor operation will be decreased.
2. If the running current does not exceed X value for five seconds, the frequency instructed will be increased.
3. However, if total outdoor unit running current exceeds Y value, the compressor will be stopped immediately for 3 minutes.
The values for X (A) and Y (A) during the first 30 minutes of cooling operation (A) are:
| Operation Mode | X (A) | Y (A) |
|---|---|---|
| Cooling/Soft Dry (A) & (C) | 4.95 | 15.06 |
| Cooling/Soft Dry (B) | 4.43 | 15.06 |
| Heating | 6.21 | 15.06 |
What is the Overheating Prevention Control for the IPM (Power transistor) on the PANASONIC CS-E10JD3EA Air Conditioner?
The Overheating Prevention Control for the IPM (Power transistor) on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. When the IPM temperature rises to 110°C, compressor operation will stop immediately.
2. Compressor operation restarts after three minutes the temperature decreases to 95°C.
What is the DC Peak Current Control for the IPM (Power transistor) on the PANASONIC CS-E10JD3EA Air Conditioner?
The DC Peak Current Control for the IPM (Power transistor) on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. When electric current to IPM exceeds set value of 22.33 ± 5.0 A, the compressor will stop operate. Then, operation will restart after three minutes.
2. If the set value is exceeded again more than 30 seconds after the compressor starts, the operation will restart after two minutes.
3. If the set value is exceeded again within 30 seconds after the compressor starts, the operation will restart after one minute. If this condition repeats continuously for seven times, all indoor and outdoor relays will be cut off.
How is the Compressor Overheating Prevention Control regulated for the PANASONIC CS-E10JD3EA Air Conditioner?
The instructed frequency for compressor operation on the PANASONIC CS-E10JD3EA Air Conditioner is regulated by compressor discharge temperature. If compressor discharge temperature exceeds 112°C, the compressor will stop, occurring 4 times per 20 minutes, and the timer LED will be blinking (“F97” is to be confirmed).
How is the compressor operating frequency regulated according to the outdoor air temperature for the PANASONIC CS-E10JD3EA Air Conditioner during Cooling & Soft Dry Operation?
The compressor operating frequency on the PANASONIC CS-E10JD3EA Air Conditioner during Cooling & Soft Dry Operation is regulated in accordance to the outdoor air temperature, beginning 1 minute after the compressor starts. The compressor frequency will adjust based on Outdoor Air Temperature.
What triggers the Cooling Overload Control (Pipe temperature limitation/restriction) on the PANASONIC CS-E10JD3EA Air Conditioner?
The Cooling Overload Control on the PANASONIC CS-E10JD3EA Air Conditioner is triggered by:
1. Detection of the Outdoor pipe temperature and applying restriction/limitation (Limit the compressor Operation frequency).
2. The compressor stopping if the outdoor pipe temperature exceeds 63°C.
3. If the compressor stops 4 times in 20 minutes, the Timer LED blinks (F95: outdoor high pressure rise protection).
What are the activation conditions for Dew Prevention Control 1 on the PANASONIC CS-E10JD3EA Air Conditioner during Cooling or Dry mode?
Dew Prevention Control 1 activates on the PANASONIC CS-E10JD3EA Air Conditioner if the following conditions are fulfilled:
1. Outdoor air temperature and Indoor pipe temperature judgment by microcontroller if fulfilled.
2. Cooling or Dry mode is operated for more than 20 minutes or more.
What are the stopping conditions for Dew Prevention Control 1 on the PANASONIC CS-E10JD3EA Air Conditioner?
Dew Prevention Control 1 stops on the PANASONIC CS-E10JD3EA Air Conditioner if:
1. Compressor stopped.
2. Remote control setting changed (fan speed / temperature).
3. Outdoor air temperature and indoor intake temperature changed.
What are the starting conditions for Dew Prevention Control 2 on the PANASONIC CS-E10JD3EA Air Conditioner?
Dew Prevention Control 2 starts on the PANASONIC CS-E10JD3EA Air Conditioner if all conditions continue for 20 minutes:
1. Operated with Cooling or Soft Dry Mode.
2. Indoor intake temperature is between 25°C and 29°C.
3. Outdoor air temperature is less than 30°C.
4. Quiet Lo fan speed.
What stops Dew Prevention Control 2 on the PANASONIC CS-E10JD3EA Air Conditioner?
Dew Prevention Control 2 stops on the PANASONIC CS-E10JD3EA Air Conditioner when it receives an air swing change signal from the Remote Control.
What are the conditions that lead to Freeze Prevention Control activating on the PANASONIC CS-E10JD3EA Air Conditioner?
Freeze Prevention Control on the PANASONIC CS-E10JD3EA Air Conditioner activates when:
1. The indoor heat exchanger temperature is lower than 7°C continuously for six minutes, causing the compressor to stop operating.
2. The compressor will resume its operation 3 minutes after the indoor heat exchanger is higher than 13°C.
3. At the same time, the indoor fan speed will be higher than during its normal operation.
4. If the indoor heat exchanger temperature is higher than 13°C for 5 minutes, the fan speed will return to its normal operation.
What conditions cause the compressor to operate at maximum frequency under Intake Air Temperature Control for Heating Operation on the PANASONIC CS-E10JD3EA Air Conditioner?
The compressor on the PANASONIC CS-E10JD3EA Air Conditioner will operate at maximum frequency under Intake Air Temperature Control for Heating Operation when the indoor intake air temperature is 30°C or above.
What is the Overload Protection Control for the compressor operating frequency during Heating Operation on the PANASONIC CS-E10JD3EA Air Conditioner?
The compressor operating frequency on the PANASONIC CS-E10JD3EA Air Conditioner during Heating Operation is regulated in accordance to the indoor heat exchanger temperature. If the heat exchanger temperature exceeds 60°C, the compressor will stop.
What initiates Cold Draught Operation on the PANASONIC CS-E10JD3EA Air Conditioner?
Cold Draught Operation starts on the PANASONIC CS-E10JD3EA Air Conditioner when the indoor pipe temperature is low, resulting in the indoor fan speed being reduced.
What initiates Deice Operation on the PANASONIC CS-E10JD3EA Air Conditioner?
Deice Operation starts on the PANASONIC CS-E10JD3EA Air Conditioner when the outdoor pipe temperature and outdoor temperature are low, causing the indoor fan motor and outdoor fan motor to stop and the operation LED to blink.
What are the malfunction decision conditions for F91 (Refrigeration Cycle Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction decision conditions for F91 (Refrigeration Cycle Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner are:
1. During cooling, compressor frequency = Fcmax.
2. During heating, compressor frequency > Fhrated.
3. During cooling and heating operation, running current: 0.65A < I < 1.65A.
4. During cooling, indoor intake – indoor pipe < 4°C.
5. During heating, indoor pipe – indoor intake < 5°C.
Multi Models Only:
– Gas shortage detection 1: A gas shortage is detected by checking the CT-detected input current value and the compressor running frequency. During startup and operating of cooling and heating, input current < 8.78/256 (A/Hz) × compressor running frequency + 0.25.
– Gas shortage detection 2: A gas shortage is detected by checking the difference between indoor pipe temperature and indoor intake air temperature during cooling and heating.
What are the malfunction causes for F91 (Refrigeration Cycle Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction causes for F91 (Refrigeration Cycle Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner are:
1. Refrigerant shortage (refrigerant leakage).
2. Poor compression performance of compressor.
3. 2/3 way valve closed.
4. Detection error due to faulty indoor intake air or indoor pipe temperature sensors.
What is the procedure for troubleshooting when F91 (Refrigeration Cycle Abnormality) indication happens on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure when F91 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the indoor air intake and pipe temperature sensors.
2. If it does not conform to the sensor characteristic chart, check the 2/3-way valve opened. If the 2/3-way valve is not opened, open the 2/3 way valve. If the 2/3-way valve is closed, check for gas leaking.
3. If gas leaks, check for oil oozing out from the 2/3 way valve. If oil is oozing out, repair the pipe flare or union nuts, reclaim and recharge refrigerant. If no gas leak is found, check if the capillary tube or dryer is clogged. If clogged, replace the capillary tube or dryer.
4. Charge for a specified amount of fresh refrigerant. If the Refrigerant cycle abnormality error occurs again, replace the outdoor unit PCB & compressor. Otherwise, the procedure is complete.
What are the malfunction decision conditions for F93 (Compressor Rotation Failure) on the PANASONIC CS-E10JD3EA Air Conditioner?
A compressor rotation failure is detected by checking the compressor running condition through the position detection circuit on the PANASONIC CS-E10JD3EA Air Conditioner, which is the malfunction decision condition for F93.
What are the malfunction causes for F93 (Compressor Rotation Failure) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction causes for F93 (Compressor Rotation Failure) on the PANASONIC CS-E10JD3EA Air Conditioner are:
1. Compressor terminal disconnect.
2. Outdoor PCB malfunction.
3. Compressor malfunction.
What is the troubleshooting procedure when F93 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure when F93 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the U, V and W connector connection. Turn OFF the power, check the U, V and W connection at outdoor unit PCB and compressor terminal.
2. If the connector connection is normal, disconnect the harnesses U, V and W from the compressor terminal. Turn ON the power and operate the inverter checker. If the blinking of the 6 LEDs in same sequence/condition occurs, replace the compressor. If not, replace the outdoor unit PCB.
3. If the connector connection is not normal, correct the connection.
What is the malfunction decision condition for F95 (Cooling High Pressure Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction decision condition for F95 (Cooling High Pressure Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner is detected when the outdoor unit heat exchanger high temperature data (61°C) is detected by the outdoor pipe temperature sensor during operation of cooling.
What are the malfunction causes for F95 (Cooling High Pressure Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction causes for F95 (Cooling High Pressure Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner are:
1. Air short circuit at outdoor unit.
2. Dust accumulation on the outdoor unit heat exchanger.
3. 2/3 way valve closed.
4. Faulty outdoor unit fan motor.
5. Excessive refrigerant.
6. Clogged expansion valve or strainer.
7. Faulty outdoor pipe temperature sensor.
8. Faulty outdoor unit PCB.
What is the troubleshooting procedure when F95 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure when F95 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the outdoor air passage. If there is any short circuit, provide sufficient air passage.
2. Check the dust accumulation on the outdoor unit heat exchanger. If it is dirty, clean the outdoor heat exchanger.
3. Check the 2/3 way valve closed? If closed, open the 2/3 way valve. If not closed, check the outdoor unit fan motor operation. If the fan motor does not operate normally, replace the outdoor unit fan motor and/or outdoor PCB.
4. Check refrigerant amount. If the additional refrigerant amount filled correctly, check for clogged expansion valve or strainer. If the expansion valve or strainer is clogged (ice formed?), replace the expansion valve and/or strainer and reclaim and recharge refrigerant. If not clogged, check the outdoor pipe temperature sensor. If it does not conform to the sensor characteristic charts, replace the outdoor pipe temperature sensor. Otherwise, replace the outdoor unit PCB.
What are the malfunction decision conditions for F96 (IPM Overheating) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction decision conditions for F96 (IPM Overheating) on the PANASONIC CS-E10JD3EA Air Conditioner during operating of cooling and heating is when IPM temperature data (100°C) is detected by the IPM temperature sensor. Multi Models Only:
Compressor Overheating: During operation of cooling and heating, when the compressor OL is activated.
Heat Sink Overheating: During operation of cooling and heating, when heat sink temperature data (90°C) is detected by the heat sink temperature sensor.
What are the malfunction causes for F96 (IPM Overheating) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction causes for F96 (IPM Overheating) on the PANASONIC CS-E10JD3EA Air Conditioner are:
1. IPM overheats due to short circuit of hot discharge air flow.
2. IPM overheats due to defective of outdoor fan motor.
3. IPM overheats due to defective of internal circuitry of IPM.
4. IPM overheats due to defective IPM temperature sensor.
Multi Models Only:
1. Compressor OL connector poor contact.
2. Compressor OL faulty.
What is the troubleshooting procedure when F96 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure when F96 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the outdoor unit installation condition during cooling or soft dry operation. If there is improper heat radiation, reinstall the outdoor unit, remove the obstacle(s), and clean the outdoor heat exchanger.
2. If there is no improper heat radiation, check if the outdoor fan motor is operating. If it is not operating, defect in IPM or replace the outdoor unit PCB.
3. If the outdoor fan motor is operating, check for improper heat radiation. If yes, proceed as in step 1. If no, it indicates defect in IPM or replace the outdoor unit PCB.
What are the malfunction decision conditions for F97 (Compressor Overheating) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction decision condition for F97 (Compressor Overheating) on the PANASONIC CS-E10JD3EA Air Conditioner is when the compressor tank temperature data (112°C) is detected by the compressor tank temperature sensor during operation of cooling and heating.
What are the malfunction causes for F97 (Compressor Overheating) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction causes for F97 (Compressor Overheating) on the PANASONIC CS-E10JD3EA Air Conditioner are:
1. Refrigerant shortage (refrigerant leakage).
2. 2/3 way valve closed.
3. Detection error due to faulty compressor tank temperature sensor.
What is the troubleshooting procedure when F97 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure when F97 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the compressor tank temperature sensor. If it does not conform to the sensor characteristic chart, replace the compressor tank temperature sensor.
2. If it conforms, check the 2/3 way valve closed? If closed, open the 2/3 way valve. If not closed, check for gas leakage.
3. If oil oozing out from the 2/3 way valve, repair the pipe flare or union nuts, reclaim and recharge refrigerant. If not, check if the capillary tube or dryer is clogged. If clogged, replace the capillary tube or dryer.
4. Charge for a specified amount of fresh refrigerant. If the Refrigerant cycle abnormality error occurs again, replace the outdoor unit PCB and compressor. Otherwise, the procedure is complete.
What are the malfunction decision conditions for F98 (Input Over Current Detection) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction decision condition for F98 (Input Over Current Detection) on the PANASONIC CS-E10JD3EA Air Conditioner is detected when an input over-current (15.06A) is checked by the current transformer (CT) with the compressor running during operation of cooling and heating.
What are the malfunction causes for F98 (Input Over Current Detection) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction causes for F98 (Input Over Current Detection) on the PANASONIC CS-E10JD3EA Air Conditioner are:
1. Over-current due to compressor failure.
2. Over-current due to defective outdoor unit PCB.
3. Over-current due to defective inverter main circuit electrolytic capacitor.
4. Over-current due to excessive refrigerant.
What is the troubleshooting procedure when F98 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure when F98 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Get restarted and measure the input current. If Input current is greater than 15.06A, turn off power supply, check the main circuit electrolytic capacitor. If it is normal, check refrigerant amount. If there is excess refrigerant, reclaim and recharge with correct amount of refrigerant. If not normal, replace the outdoor unit PCB.
2. If Input current is not greater than 15.06A, it indicates that the input current is normal.
What are the malfunction decision conditions for F99 (Output Over Current Detection) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction decision condition for F99 (Output Over Current Detection) on the PANASONIC CS-E10JD3EA Air Conditioner is detected by checking the current that flows in the inverter DC peak sensing circuitry when an output over-current (20.2A) occurs during operation of cooling and heating.
What are the malfunction causes for F99 (Output Over Current Detection) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction causes for F99 (Output Over Current Detection) on the PANASONIC CS-E10JD3EA Air Conditioner are:
1. DC peak due to compressor failure.
2. DC peak due to defective power transistor(s).
3. DC peak due to defective outdoor unit PCB.
What is the troubleshooting procedure for checking the power transistor when F99 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure for checking the power transistor when F99 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Get restarted and measure the input current. If Input current > 20.2A, check the compressor winding resistance (U-V, V-W, W-U) after turning off the power and disconnecting the harness U, V and W from the terminal board. If the compressor’s winding resistance (U-V, V-W, W-U) are not uniform, replace the compressor. If uniform, check if the outdoor electronic circuit defect due to power transistor is present. If so, replace the outdoor unit PCB.
2. If Input current is not greater than 20.2A, replace the outdoor unit PCB.
Note: Never touch any live parts for at least 10 minutes after turning off the circuit breaker. If unavoidable necessary to touch a live part, make sure the power transistor’s supply voltage is below 50V using the tester. For the UVW, make measurement at the Faston terminal on the board of the relay connector.
| Tester’s negative terminal | Power transistor (+) | UVW | Power transistor (-) | UVW |
|---|---|---|---|---|
| Tester’s positive terminal | UVW | Power transistor (+) | UVW | Power transistor (-) |
| Normal resistance | Several kΩ to several MΩ | |||
| Abnormal resistance | 0 Ω or – |
What is the malfunction cause for H11 (Indoor/Outdoor Abnormal Communication) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction causes for H11 (Indoor/Outdoor Abnormal Communication) on the PANASONIC CS-E10JD3EA Air Conditioner are:
1. Faulty indoor unit PCB.
2. Faulty outdoor unit PCB.
3. Indoor unit-outdoor unit signal transmission error due to wrong wiring.
4. Indoor unit-outdoor unit signal transmission error due to breaking of wire in the connection wires between the indoor and outdoor units.
5. Indoor unit-outdoor unit signal transmission error due to disturbed power supply waveform.
What is the troubleshooting procedure for H11 (Indoor/Outdoor Abnormal Communication) on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure for H11 (Indoor/Outdoor Abnormal Communication) on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the indoor-outdoor units’ connection wires. If there is any wiring error, correct the indoor-outdoor units connection wires. If no wiring error, check indoor and outdoor units model number. If model numbers do not match, match the compatible model(s). If model numbers match, check the spare part numbers of the indoor and outdoor unit PCBs and compare with their Part data. If they match, check compatibility. If not compatible, change for the specified indoor or outdoor unit PCB. If compatible, replace indoor unit PCB.
2. Disconnect terminal 3 wire and measure Vdc between terminal 2 & 3 from the outdoor unit. If the Vdc fluctuates between 20-70Vdc, replace outdoor PCB. If the Vdc is between 20-50Vdc, reconnect terminal 3 wire and measure Vdc between terminal 2 & 3 from the outdoor unit. If Vdc fluctuates between 20-50Vdc, replace indoor unit PCB.
What is the troubleshooting procedure for H14 (Indoor Intake Air Temperature Sensor Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure for H14 (Indoor Intake Air Temperature Sensor Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the connector connection: Turn off the power and check the connector connection. If the connector connection is not normal, connector poor contact or correct the connection.
2. If the connector connection is normal, check the indoor intake air temperature sensor: Plug out connector from the indoor unit PCB and measure the resistance of the indoor intake air temperature sensor. If the measured resistance of the indoor intake air temperature sensor matches the value specified in its characteristic chart, defect in indoor unit PCB or replace the indoor unit PCB. If it does not match, defect in indoor intake air temperature sensor or replace the indoor intake air temperature sensor.
What is the troubleshooting procedure for H15 (Compressor Temperature Sensor Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure for H15 (Compressor Temperature Sensor Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the connector connection: Turn off the power and check the connector connection. If the connector connection is not normal, connector poor contact or correct the connection.
2. If the connector connection is normal, check the outdoor compressor temperature sensor: Plug out connector from the outdoor unit PCB and measure the resistance of the outdoor compressor temperature sensor. If the measured resistance of the outdoor compressor temperature sensor matches the value specified in its characteristic chart, defect in outdoor unit PCB or replace the outdoor unit PCB. If it does not match, defect in outdoor compressor temperature sensor or replace the outdoor compressor temperature sensor.
What is the troubleshooting procedure when H16 (Outdoor Current Transformer Open Circuit) occurs on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure when H16 occurs on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Operate normal heating operation. When H16 occurs again, turn OFF the power.
2. Check the 2/3 way valve. If it is closed, check for gas leakage. If there is gas leakage, repair the pipe flare or union nuts, reclaim and recharge refrigerant. If no gas leakage, check if oil is oozing out from the 2/3 way valve. If yes, repair the pipe flare or union nuts, reclaim and recharge refrigerant. If no oil oozing out, turn ON the power and operate FORCE HEATING. Measure the current from the outdoor LIVE terminal. If the current is < 1.0A, it is a defect in CT or replace the outdoor unit PCB. If current is > 1.0A, while still in FORCE HEATING, check the discharge pressure. If the pressure is unchanged (same as when compressor stop), replace the outdoor unit PCB. If pressure changed, while still in FORCE HEATING, further check by touching: If the compressor discharge pipe is cold and compressor body is warm, it confirms compressor low compression, replace the compressor. If the compressor discharge pipe is warm and compressor body is cold, it confirms compressor low compression, replace the compressor.
What is the troubleshooting procedure when H19 (Indoor Fan Motor – DC Motor Mechanism Locked) indication starts again on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure when H19 indication starts again on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Turn off power supply and rotate fan by hand. If the fan does not rotate smoothly, replace fan motor.
2. If the fan rotates smoothly, turn power supply on and operate fan. If it does not rotate, stop fan motor. Then check the rotation feedback output from fan motor.
3. If the fan rotates, turn off power supply and disconnect fan motor connector, then turn power on. Check the output of fan motor from indoor PCB. If the motor power supply voltage is not generated (pin 1 & 4 are not ~325Vdc), or motor control voltage is not generated (pin 5 & 4 are not 15Vdc), or rotation command voltage is not generated (pin 2 & 4 are 1-5Vdc), replace indoor PCB. If motor power supply voltage, motor control voltage, and rotation command voltage are generated, replace fan motor.
What is the troubleshooting procedure for H23 (Indoor Pipe Temperature Sensor Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure for H23 (Indoor Pipe Temperature Sensor Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the connector connection: Plug out connector from the indoor unit PCB and measure the resistance of the indoor pipe temperature sensor. If the connector connection is not normal, connector poor contact or correct the connection.
2. If the connector connection is normal, check the outdoor air temperature sensor: Plug out connector from the outdoor unit PCB and measure the resistance of the outdoor air temperature sensor. If the measured resistance of the outdoor air temperature sensor matches the value specified in its characteristic chart, detect in outdoor unit PCB or replace the outdoor unit PCB. If it does not match, defect in outdoor air temperature sensor or replace the outdoor air temperature sensor.
What is the troubleshooting procedure for H24 (Indoor Pipe Temperature Sensor 2 Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure for H24 (Indoor Pipe Temperature Sensor 2 Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the connector connection: Plug out connector from the indoor unit PCB and measure the resistance of the indoor pipe temperature sensor. If the connector connection is not normal, connector poor contact or correct the connection.
2. If the connector connection is normal, check the outdoor air temperature sensor: Plug out connector from the outdoor unit PCB and measure the resistance of the outdoor air temperature sensor. If the measured resistance of the outdoor intake air temperature sensor matches the value specified in its characteristic chart, defect in outdoor unit PCB or replace the outdoor unit PCB. If it does not match, defect in outdoor intake air temperature sensor or replace the outdoor intake air temperature sensor.
What is the troubleshooting procedure for H27 (Outdoor Air Temperature Sensor Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure for H27 (Outdoor Air Temperature Sensor Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the connector connection: Turn off the power and check the connector connection. If the connector connection is not normal, connector poor contact or correct the connection.
2. If the connector connection is normal, check the outdoor air temperature sensor: Plug out connector from the outdoor unit PCB and measure the resistance of the outdoor air temperature sensor. If the measured resistance of the outdoor air temperature sensor matches the value specified in its characteristic chart, defect in outdoor unit PCB or replace the outdoor unit PCB. If it does not match, defect in outdoor air temperature sensor or replace the outdoor air temperature sensor.
What is the troubleshooting procedure for H28 (Outdoor Pipe Temperature Sensor Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure for H28 (Outdoor Pipe Temperature Sensor Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the connector connection: Turn off the power and check the connector connection. If the connector connection is not normal, connector poor contact or correct the connection.
2. If the connector connection is normal, check the outdoor heat exchanger temperature sensor: Plug out connector from the outdoor unit PCB and measure the resistance of the outdoor heat exchanger temperature sensor. If the measured resistance of the outdoor heat exchanger temperature sensor matches the value specified in its characteristic chart, defect in outdoor heat exchanger temperature sensor or replace the outdoor heat exchanger temperature sensor. If it does not match, defect in outdoor unit PCB or replace the outdoor unit PCB.
What is the troubleshooting procedure for H30 (Compressor Discharge Temperature Sensor Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure for H30 (Compressor Discharge Temperature Sensor Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the connector connection: Turn off the power and check the connector connection. If the connector connection is not normal, connector poor contact or correct the connection.
2. If the connector connection is normal, check the outdoor discharge pipe temperature sensor: Plug out connector from the outdoor unit PCB and measure the resistance of the outdoor discharge pipe temperature sensor. If the measured resistance of the outdoor discharge pipe temperature sensor matches the value specified in its characteristic chart, defect in outdoor discharge pipe temperature sensor or replace the outdoor discharge pipe temperature sensor. If it does not match, defect in outdoor unit PCB or replace the outdoor unit PCB.
What is the troubleshooting procedure when H98 (Indoor High Pressure Protection) Malfunction Decision Conditions are met for the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure when H98 (Indoor High Pressure Protection) occurs on the PANASONIC CS-E10JD3EA Air Conditioner:
1. Check the air passage. If there is no short circuit, provide sufficient air passage.
2. Check the indoor unit air filter. If it is dirty, clean the air filter.
3. Check the dust accumulation on the indoor unit heat exchanger. If dirty, clean the indoor unit heat exchanger.
4. Check the 2/3 way valve. If it is closed, open the 2/3 way valve. If not closed, check the indoor unit fan motor operation. If the indoor unit fan motor does not operate normally, replace the indoor unit fan motor and/or indoor unit PCB.
5. Check refrigerant amount. If refrigerant amount is not checked for gas leakage, check for gas leakage. If gas leaks, repair the pipe flare or union nuts, reclaim and recharge refrigerant. If no gas leakage, check if the additional refrigerant amount filled correctly. If not filled correctly, reclaim and recharge with correct amount of refrigerant. If filled correctly, check for clogged expansion valve or strainer. If the expansion valve or strainer is clogged (ice formed?), replace the expansion valve and/or strainer and reclaim and recharge refrigerant. If not clogged, check the indoor pipe temperature sensor. If it does not conform to the sensor characteristic chart, replace the indoor pipe temperature sensor. Otherwise, replace the indoor unit PCB.
What is the troubleshooting procedure when H99 (Indoor Freeze Prevention Protection: Cooling or Soft Dry) Malfunction Decision Conditions are met for the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure when H99 (Indoor Freeze Prevention Protection: Cooling or Soft Dry) Malfunction Decision Conditions are met for the PANASONIC CS-E10JD3EA Air Conditioner:
1. Check the air passage. If there is any short circuit, provide sufficient air passage.
2. Check the indoor unit air filter. If it is dirty, clean the air filter.
3. Check the dust accumulation on the indoor unit heat exchanger. If dirty, clean the indoor unit heat exchanger.
4. Check the 2/3 way valve. If the 2/3 way valve is closed, open the 2/3 way valve. If not closed, check the indoor unit fan motor operation. If the indoor unit fan motor does not operate normally, replace the indoor unit fan motor and/or indoor unit PCB.
5. If the indoor unit fan motor operates normally, check for gas leakage. If gas leaks, repair the pipe flare or union nuts, reclaim and recharge refrigerant. If no gas leakage, check for clogged expansion valve or strainer. If the expansion valve or strainer is clogged (ice formed?), replace the expansion valve and/or strainer and reclaim and recharge refrigerant. If not clogged, check the indoor pipe temperature sensor. If it does not conform to the sensor characteristic chart, replace the indoor pipe temperature sensor. Otherwise, replace the indoor unit PCB.
What are the malfunction decision conditions for F11 (4-way valve Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction decision conditions for F11 (4-way valve Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner are:
1. When heating operation, when indoor pipe temperature is below 10°C.
2. When cooling operation, when indoor pipe temperature is above 45°C.
What are the malfunction causes for F11 (4-way valve Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction causes for F11 (4-way valve Abnormality) on the PANASONIC CS-E10JD3EA Air Conditioner are:
1. Connector in poor contact.
2. Faulty sensor.
3. Faulty outdoor unit PCB.
4. 4-way valve defective.
What is the troubleshooting procedure when F11 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure when F11 indication happens on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the indoor pipe temperature sensor. If it does not conform to the sensor characteristic chart, replace the indoor pipe temperature sensor. If it conforms, check if the 4-way valve coil is energized during cooling operation. If it is energized, replace the outdoor unit PCB. If not energized, check harness out of connector. If harness is out of connector, reconnect the harness. If harness is connected, check the continuity of the 4-way valve coil. If there is no continuity, replace the 4-way valve coil. If there is continuity, disconnect the harness from the connector. Measure the resistance between harnesses. If resistance is about 18Ω, measure DC voltage supply to CN-HOT (pin1 & 2) during heating operation. If the voltage supply to 4-way valve is 2.5-4.5Vdc, replace the outdoor unit PCB. If not, replace the 4-way valve.
What are the malfunction decision conditions for F90 (Power Factor Correction Protection) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction decision conditions for F90 (Power Factor Correction Protection) on the PANASONIC CS-E10JD3EA Air Conditioner occur during startup and operation of cooling and heating, when the Power Factor Correction (PFC) protection circuitry at the outdoor unit main PCB senses an abnormal high DC voltage level.
What are the malfunction causes for F90 (Power Factor Correction Protection) on the PANASONIC CS-E10JD3EA Air Conditioner?
The malfunction causes for F90 (Power Factor Correction Protection) on the PANASONIC CS-E10JD3EA Air Conditioner are:
1. DC voltage peak due to power supply surge.
2. DC voltage peak due to compressor windings not uniform.
3. Faulty outdoor PCB.
What is the troubleshooting procedure when abnormality indication starts again for F90 (Power Factor Correction Protection) on the PANASONIC CS-E10JD3EA Air Conditioner?
The troubleshooting procedure when abnormality indication starts again for F90 (Power Factor Correction Protection) on the PANASONIC CS-E10JD3EA Air Conditioner is:
1. Check the supply voltage. If supply voltage is not as specified, correct the power supply.
2. If supply voltage is as specified, operate the system. Verify PFC abnormality by measuring DC voltage between P(+) and N(-) terminal at the outdoor unit PCB. If the DC voltage is not between 285-315Vdc, it is a defect in PFC circuitry or replace the outdoor unit PCB.
3. If the DC voltage is between 285-315Vdc, check the compressor winding resistance. Turn off the power supply and reconnect the harness U, V and W. Measure the winding resistance between U-V, V-W and W-U. If the compressor’s winding resistance (U-V, V-W, W-U) are not uniform, replace the compressor. If uniform, replace the outdoor unit PCB.
What are the specifications for Power Supply for PANASONIC CS-E10JD3EA CU-E10HBEA?
The specifications for Power Supply for PANASONIC CS-E10JD3EA CU-E10HBEA are:
| Performance Test Condition | Phase, Hz | V | Min. | Mid. | Max. | Min. | Mid. | Max. |
|---|---|---|---|---|---|---|---|---|
| Power Supply | Single, 50 | 230 | 240 |
What are the Cooling Capacity specifications for PANASONIC CS-E10JD3EA CU-E10HBEA?
The Cooling Capacity specifications for PANASONIC CS-E10JD3EA CU-E10HBEA are:
| Capacity | kW | Min. | Mid. | Max. | Min. | Mid. | Max. |
|---|---|---|---|---|---|---|---|
| 0.60 | 2.50 | 3.00 | 0.60 | 2.50 | 3.00 | ||
| BTU/h | 2050 | 8530 | 10200 | 2050 | 8530 | 10200 | |
| Kcal/h | 520 | 2150 | 2580 | 520 | 2150 | 2580 |
What are the Heating Capacity specifications for PANASONIC CS-E10JD3EA CU-E10HBEA?
The Heating Capacity specifications for PANASONIC CS-E10JD3EA CU-E10HBEA are:
| Capacity | kW | Min. | Mid. | Max. | Min. | Mid. | Max. |
|---|---|---|---|---|---|---|---|
| 0.60 | 3.20 | 5.00 | 0.60 | 3.20 | 5.00 | ||
| BTU/h | 2050 | 10900 | 17100 | 2050 | 10900 | 17100 | |
| Kcal/h | 520 | 2750 | 4300 | 520 | 2750 | 4300 |
What is the Indoor Noise (H / L / QLo) for PANASONIC CS-E10JD3EA CU-E10HBEA?
The Indoor Noise (H / L / QLo) for PANASONIC CS-E10JD3EA CU-E10HBEA is 33 / 27 / 24 dB-A for both Indoor and Outdoor units.
What is the Outdoor Noise (H / L) for PANASONIC CS-E10JD3EA CU-E10HBEA?
The Outdoor Noise (H / L) for PANASONIC CS-E10JD3EA CU-E10HBEA is 46 / – / – dB-A for both Indoor and Outdoor units.
What is the compressor output power in Watts for the PANASONIC CS-E10JD3EA CU-E10HBEA?
The compressor output power in Watts for the PANASONIC CS-E10JD3EA CU-E10HBEA is 750 W.
What is the Indoor Fan Motor Output Power in Watts for the PANASONIC CS-E10JD3EA CU-E10HBEA?
The Indoor Fan Motor Output Power in Watts for the PANASONIC CS-E10JD3EA CU-E10HBEA is 30 W.
What is the Outdoor Fan Motor Output Power in Watts for the PANASONIC CS-E10JD3EA CU-E10HBEA?
The Outdoor Fan Motor Output Power in Watts for the PANASONIC CS-E10JD3EA CU-E10HBEA is 40 W.
What is the Moisture Removal rate in L/h (Pt/h) for the PANASONIC CS-E10JD3EA CU-E10HBEA?
The Moisture Removal rate in L/h (Pt/h) for the PANASONIC CS-E10JD3EA CU-E10HBEA is 1.5 (3.2) L/h (Pt/h).
What is the standard length for piping when installing the PANASONIC CS-E10JD3EA CU-E10HBEA?
The standard length for piping when installing the PANASONIC CS-E10JD3EA CU-E10HBEA is 7.5 m (24.6 ft).
What is the recommended amount of additional refrigerant for the PANASONIC CS-E10JD3EA CU-E10HBEA per meter of piping length difference?
The recommended amount of additional refrigerant for the PANASONIC CS-E10JD3EA CU-E10HBEA per meter of piping length difference is 20 g/m (0.2 oz/ft).
What are the dimensions (Height, Width, Depth) for the Indoor Unit of the PANASONIC CS-E10JD3EA?
The dimensions for the Indoor Unit of the PANASONIC CS-E10JD3EA are:
| Dimension | Measurement | mm (inch) |
|---|---|---|
| Height | 235 (9-9/32) | |
| Width | 750 (29-17/32) | |
| Depth | 370 (14-19/32) |
What are the dimensions (Height, Width, Depth) for the Outdoor Unit of the PANASONIC CU-E10HBEA?
The dimensions for the Outdoor Unit of the PANASONIC CU-E10HBEA are:
| Dimension | Measurement | mm (inch) |
|---|---|---|
| Height | 540 (21-9/32) | |
| Width | 780 (30-23/32) | |
| Depth | 289 (11-13/32) |
What are the Indoor Operation Range limits (Dry Bulb and Wet Bulb temperatures in °C) for Cooling on the PANASONIC CS-E10JD3EA?
The Indoor Operation Range limits for Cooling on the PANASONIC CS-E10JD3EA are:
| Dry Bulb | Wet Bulb | |
|---|---|---|
| Maximum | 32 | 23 |
| Minimum | 16 | 11 |
What are the Outdoor Operation Range limits (Dry Bulb and Wet Bulb temperatures in °C) for Cooling on the PANASONIC CU-E10HBEA?
The Outdoor Operation Range limits for Cooling on the PANASONIC CU-E10HBEA are:
| Dry Bulb | Wet Bulb | |
|---|---|---|
| Maximum | 43 | 26 |
| Minimum | -10 | – |
What are the Indoor Operation Range limits (Dry Bulb) for Heating on the PANASONIC CS-E10JD3EA?
The Indoor Operation Range limits for Heating on the PANASONIC CS-E10JD3EA (Dry Bulb) are:
| Dry Bulb | |
|---|---|
| Maximum | 30 |
| Minimum | 16 |
What are the Outdoor Operation Range limits (Dry Bulb and Wet Bulb temperatures in °C) for Heating on the PANASONIC CU-E10HBEA?
The Outdoor Operation Range limits for Heating on the PANASONIC CU-E10HBEA are:
| Dry Bulb | Wet Bulb | |
|---|---|---|
| Maximum | 24 | 18 |
| Minimum | -10 | – |
What is the Indoor Fan Motor Speed (QLo, Cool mode) for the PANASONIC CS-E10JD3EA?
The Indoor Fan Motor Speed (QLo, Cool mode) for the PANASONIC CS-E10JD3EA is 1000 rpm.
What is the Indoor Fan Motor Speed (SHi, Heat mode) for the PANASONIC CS-E10JD3EA?
The Indoor Fan Motor Speed (SHi, Heat mode) for the PANASONIC CS-E10JD3EA is 1440 rpm.
What is the Outdoor Fan Motor Speed (Hi, Cool mode) for the PANASONIC CU-E10HBEA?
The Outdoor Fan Motor Speed (Hi, Cool mode) for the PANASONIC CU-E10HBEA is 800 rpm.
What is the Indoor Airflow (Me, Cool mode) for the PANASONIC CS-E10JD3EA in m3/min (ft3/min)?
The Indoor Airflow (Me, Cool mode) for the PANASONIC CS-E10JD3EA is 5.8 (210) m3/min (ft3/min).
What is the Outdoor Airflow (Hi, Heat mode) for the PANASONIC CU-E10HBEA in m3/min (ft3/min)?
The Outdoor Airflow (Hi, Heat mode) for the PANASONIC CU-E10HBEA is 29.5 (1040) m3/min (ft3/min).
What is the required amount of Refrigerant Oil in cm3 for the PANASONIC CS-E10JD3EA CU-E10HBEA?
The required amount of Refrigerant Oil in cm3 for the PANASONIC CS-E10JD3EA CU-E10HBEA is RB68A or Freol Alpha 68M (400) cm3.
What is the type and amount of Refrigerant for the PANASONIC CS-E10JD3EA CU-E10HBEA?
The Refrigerant Type for the PANASONIC CS-E10JD3EA CU-E10HBEA is R410A, 1.15k (40.6) g (oz).
What is the length range (min – max) for piping when installing the PANASONIC CS-E10JD3EA CU-E10HBEA?
The piping length range (min – max) for the PANASONIC CS-E10JD3EA CU-E10HBEA is 3 (9.8) m to 20 (65.6) m (ft).
What is the height difference allowed between Indoor and Outdoor unit piping connection for the PANASONIC CS-E10JD3EA CU-E10HBEA?
The I/D & O/D Height Different for the PANASONIC CS-E10JD3EA CU-E10HBEA is 15 m (49.2 ft).
What is the drain hose inner diameter and length for the PANASONIC CS-E10JD3EA CU-E10HBEA?
The drain hose inner diameter for the PANASONIC CS-E10JD3EA CU-E10HBEA is 14 mm, and the length is 255 mm.
What is the Fin Material for the Indoor Heat Exchanger of the PANASONIC CS-E10JD3EA?
The Fin Material for the Indoor Heat Exchanger of the PANASONIC CS-E10JD3EA is Aluminium (Pre Coat).
What is the Fin Material for the Outdoor Heat Exchanger of the PANASONIC CU-E10HBEA?
The Fin Material for the Outdoor Heat Exchanger of the PANASONIC CU-E10HBEA is Aluminium.
What are the Row × Stage × FPI specifications for the Outdoor Heat Exchanger of the PANASONIC CU-E10HBEA?
The Row × Stage × FPI specifications for the Outdoor Heat Exchanger of the PANASONIC CU-E10HBEA are 2 × 24 × 17.
What is the required method for cleaning the drain piping for the PANASONIC CS-E10JD3EA Indoor Unit installation?
For the PANASONIC CS-E10JD3EA Indoor Unit installation, if drain piping or connecting piping is in the room (where dew may form), the insulation should be increased by using POLY-E FOAM with thickness 8 mm or above.
What is the recommended procedure for checking the drainage after connecting the power supply for the PANASONIC CS-E10JD3EA?
To check the drainage after connecting the power supply for the PANASONIC CS-E10JD3EA:
1. Pour approximately 600 cc of water into the drain pan of the main unit using a squeeze bottle, etc.
2. Press the drain test run switch on the control board in the control box to start the drain motor and check whether the water drains normally. (The drain motor operates for approximately 5 minutes and then stops automatically.)
What is the required Test Run Operation procedure (for Pump Down/Servicing Purpose) for the outdoor unit PCB of the PANASONIC CS-E10JD3EA CU-E10HBEA?
The Test Run operation for the outdoor unit PCB of the PANASONIC CS-E10JD3EA CU-E10HBEA will be activated by short-circuiting CN-S at the outdoor unit PCB after applying power between the terminal 1 and 2. The unit is then forced to run rated frequency cooling operation mode.
What are the standard values for Normal Pressure and Outlet Air Temperature for Cooling Mode on the PANASONIC CS-E10JD3EA?
The standard values for Normal Pressure and Outlet Air Temperature for Cooling Mode on the PANASONIC CS-E10JD3EA are:
| Gas pressure MPa (kg/cm2G) | Outlet air temperature (°C) |
|---|---|
| 0.9 – 1.2 (9 – 12) | 12 – 16 |
Condition: Indoor fan speed High, Outdoor temperature 35°C at cooling mode and 7°C at heating mode. Compressor operates at rated frequency.
What are the standard values for Normal Pressure and Outlet Air Temperature for Heating Mode on the PANASONIC CS-E10JD3EA?
The standard values for Normal Pressure and Outlet Air Temperature for Heating Mode on the PANASONIC CS-E10JD3EA are:
| Gas pressure MPa (kg/cm2G) | Outlet air temperature (°C) |
|---|---|
| 2.3 – 2.9 (23 – 29) | 36 – 45 |
Condition: Indoor fan speed High, Outdoor temperature 35°C at cooling mode and 7°C at heating mode. Compressor operates at rated frequency.
What is the required procedure for detaching the Upper and Inner Casing of the PANASONIC CS-E10JD3EA Indoor Unit?
The required procedure for detaching the Upper and Inner Casing of the PANASONIC CS-E10JD3EA Indoor Unit is:
1. Unscrew the 10 screws on the Upper and Inner Casing and detach them.
What is the required procedure for detaching the Control Board of the PANASONIC CS-E10JD3EA Indoor Unit?
The required procedure for detaching the Control Board of the PANASONIC CS-E10JD3EA Indoor Unit is:
1. Unscrew the 2 screws on the Control Board and open the Control Board Cover.
2. Pull the Control Board down following the Slide Guide.
3. Lift the Control Board up from the bottom, disengage the Catch holding the Board.
What is the procedure for Detaching the Fan on the PANASONIC CS-E10JD3EA Indoor Unit?
The procedure for Detaching the Fan on the PANASONIC CS-E10JD3EA Indoor Unit is:
1. First detach the Upper and Inner Casing (16.1.1).
2. Disengage the 4 catches (2 each on the left and right) on the Air Guide.
3. Use a 2.5 mm hexagonal wrench to loosen the 2 bolts connecting the Fan Motor and Fan, detach the shaft connecting the Fan Motor and Fan, loosen the screw holding the Fan and detach the Fan.
What is the procedure for Detaching the Fan Motor on the PANASONIC CS-E10JD3EA Indoor Unit?
The procedure for Detaching the Fan Motor on the PANASONIC CS-E10JD3EA Indoor Unit is:
1. First detach the Upper and Inner Casing (16.1.1) and the Fan (16.1.3).
2. Unscrew the 4 screws holding the Fan Motor and detach it.
What is the procedure for Detaching the Drain Motor on the PANASONIC CS-E10JD3EA Indoor Unit?
The procedure for Detaching the Drain Motor on the PANASONIC CS-E10JD3EA Indoor Unit is:
1. First detach the Upper and Inner Casing (16.1.1) and the Fan (16.1.3).
2. From the Fan Motor side, undo the 2 hexagon bolts and detach the Drain Motor.
What is the error code for “No abnormality detected” on the PANASONIC CS-E10JD3EA?
The error code for “No abnormality detected” on the PANASONIC CS-E10JD3EA is H00. The abnormality judgement is “Normal operation” and the primary location to verify is “Normal operation”.
What is the error code for “Indoor / outdoor abnormal communication” on the PANASONIC CS-E10JD3EA?
The error code for “Indoor / outdoor abnormal communication” on the PANASONIC CS-E10JD3EA is H11. The abnormality judgement is “> 1 min. after starting operation” and the emergency operation is “Indoor fan operation only”. The primary location to verify is “Internal / external cable connections” or “Indoor / Outdoor PCB”.
What is the error code for “Connection capability rank abnormal” on the PANASONIC CS-E10JD3EA?
The error code for “Connection capability rank abnormal” on the PANASONIC CS-E10JD3EA is H12. The abnormality judgement is empty and there is no emergency operation. The primary location to verify is empty.
What is the error code for “Indoor intake air temperature sensor abnormality” on the PANASONIC CS-E10JD3EA?
The error code for “Indoor intake air temperature sensor abnormality” on the PANASONIC CS-E10JD3EA is H14. The abnormality judgement is “Continue for 5 sec.” and there is no emergency operation. The primary location to verify is “Intake air temperature sensor (defective or disconnected)”.
What is the error code for “Outdoor compressor temperature sensor abnormality” on the PANASONIC CS-E10JD3EA?
The error code for “Outdoor compressor temperature sensor abnormality” on the PANASONIC CS-E10JD3EA is H15. The abnormality judgement is “Continue for 5 sec.” and there is no emergency operation. The primary location to verify is “Compressor temperature sensor (defective or disconnected)”.
What is the error code for “Outdoor Current Transformer open circuit” on the PANASONIC CS-E10JD3EA?
The error code for “Outdoor Current Transformer open circuit” on the PANASONIC CS-E10JD3EA is H16. The abnormality judgement is empty and there is no emergency operation. The primary location to verify is “Outdoor PCB” or “IPM (Power transistor) module”.
What is the error code for “Indoor fan motor merchanism lock” on the PANASONIC CS-E10JD3EA?
The error code for “Indoor fan motor merchanism lock” on the PANASONIC CS-E10JD3EA is H19. The abnormality judgement is empty and there is no emergency operation. The primary location to verify is “Indoor PCB” or “Fan motor”.
What is the error code for “Indoor float switch operation abnormal” on the PANASONIC CS-E10JD3EA?
The error code for “Indoor float switch operation abnormal” on the PANASONIC CS-E10JD3EA is H21. The abnormality judgement is empty and the emergency operation is “O”. The primary location to verify is empty.
What is the error code for “Indoor heat exchanger temperature sensor 1 abnormality” on the PANASONIC CS-E10JD3EA?
The error code for “Indoor heat exchanger temperature sensor 1 abnormality” on the PANASONIC CS-E10JD3EA is H23. The abnormality judgement is “Continue for 5 sec.” and the emergency operation is “O (Cooling only)”. The primary location to verify is “Heat exchanger temperature sensor 1 (defective or disconnected)”.
What is the error code for “Indoor heat exchanger temperature sensor 2 abnormality” on the PANASONIC CS-E10JD3EA?
The error code for “Indoor heat exchanger temperature sensor 2 abnormality” on the PANASONIC CS-E10JD3EA is H24. The abnormality judgement is “Continue for 5 sec.” and there is no emergency operation. The primary location to verify is “Heat exchanger temperature sensor 2 (defective or disconnected)”.
What is the error code for “Outdoor air temperature sensor abnormality” on the PANASONIC CS-E10JD3EA?
The error code for “Outdoor air temperature sensor abnormality” on the PANASONIC CS-E10JD3EA is H27. The abnormality judgement is “Continue for 5 sec.” and the emergency operation is “O”. The primary location to verify is “Outdoor temperature sensor (defective or disconnected)”.
What is the error code for “Outdoor heat exchanger temperature sensor abnormality” on the PANASONIC CS-E10JD3EA?
The error code for “Outdoor heat exchanger temperature sensor abnormality” on the PANASONIC CS-E10JD3EA is H28. The abnormality judgement is “Continue for 5 sec.” and the emergency operation is “O”. The primary location to verify is “Outdoor heat exchanger temperature sensor (defective or disconnected)”.
What is the error code for “Discharge temperature sensor abnormality” on the PANASONIC CS-E10JD3EA?
The error code for “Discharge temperature sensor abnormality” on the PANASONIC CS-E10JD3EA is H30. The abnormality judgement is “Continue for 5 sec.” and there is no emergency operation. The primary location to verify is “Discharge temperature sensor”.
What is the error code for “Indoor drain water adverse current abnormal” on the PANASONIC CS-E10JD3EA?
The error code for “Indoor drain water adverse current abnormal” on the PANASONIC CS-E10JD3EA is H35. The abnormality judgement is empty and there is no emergency operation. The primary location to verify is empty.
What is the error code for “Outdoor Fan Motor lock abnormality” on the PANASONIC CS-E10JD3EA?
The error code for “Outdoor Fan Motor lock abnormality” on the PANASONIC CS-E10JD3EA is H97. The abnormality judgement is “2 times occurrence within 30 minutes” and there is no emergency operation. The primary location to verify is “Outdoor PCB” or “Outdoor Fan Motor”.
What is the error code for “Indoor high pressure protection” on the PANASONIC CS-E10JD3EA?
The error code for “Indoor high pressure protection” on the PANASONIC CS-E10JD3EA is H98. The error code will not display (no Timer LED blinking) but is stored in EEPROM. The abnormality judgement is empty and there is no emergency operation. The primary location to verify is “Air filter dirty” or “Air circulation short circuit”.
What is the error code for “Indoor heat exchanger anti-freezing protection” on the PANASONIC CS-E10JD3EA?
The error code for “Indoor heat exchanger anti-freezing protection” on the PANASONIC CS-E10JD3EA is H99. The error code will not display (no Timer LED blinking) but is stored in EEPROM. The abnormality judgement is empty and there is no emergency operation. The primary location to verify is “Insufficient refrigerant” or “Air filter dirty”.
What is the error code for “Cooling / Heating cycle changeover abnormality” on the PANASONIC CS-E10JD3EA?
The error code for “Cooling / Heating cycle changeover abnormality” on the PANASONIC CS-E10JD3EA is F11. The abnormality judgement is “4 times occurrence within 30 minutes” and there is no emergency operation. The primary location to verify is “4-way valve” or “V-coil”.
What is the error code for “PFC control” on the PANASONIC CS-E10JD3EA?
The error code for “PFC control” on the PANASONIC CS-E10JD3EA is F90. The abnormality judgement is “4 times occurrence within 10 minutes” and there is no emergency operation. The primary location to verify is “Voltage at PFC”.
What is the error code for “Refrigeration cycle abnormality” on the PANASONIC CS-E10JD3EA?
The error code for “Refrigeration cycle abnormality” on the PANASONIC CS-E10JD3EA is F91. The abnormality judgement is “2 times occurrence within 20 minutes” and there is no emergency operation. The primary location to verify is “No refrigerant (3-way valve is closed)”.
What is the error code for “Outdoor compressor abnormal revolution” on the PANASONIC CS-E10JD3EA?
The error code for “Outdoor compressor abnormal revolution” on the PANASONIC CS-E10JD3EA is F93. The abnormality judgement is “4 times occurrence within 20 minutes” and there is no emergency operation. The primary location to verify is “Outdoor compressor”.
What is the error code for “Cool high pressure protection” on the PANASONIC CS-E10JD3EA?
The error code for “Cool high pressure protection” on the PANASONIC CS-E10JD3EA is F95. The abnormality judgement is “4 times occurrence within 20 minutes” and there is no emergency operation. The primary location to verify is “Outdoor refrigerant circuit”.
What is the error code for “IPM (power transistor) overheating protection” on the PANASONIC CS-E10JD3EA?
The error code for “IPM (power transistor) overheating protection” on the PANASONIC CS-E10JD3EA is F96. The abnormality judgement is empty and there is no emergency operation. The primary location to verify is “Excess refrigerant”, “Improper heat radiation”, or “IPM (Power transistor)”.
What is the error code for “Outdoor compressor overheating protection” on the PANASONIC CS-E10JD3EA?
The error code for “Outdoor compressor overheating protection” on the PANASONIC CS-E10JD3EA is F97. The abnormality judgement is “4 times occurrence within 20 minutes” and there is no emergency operation. The primary location to verify is “Insufficient refrigerant” or “Compressor”.
What is the error code for “Total running current protection” on the PANASONIC CS-E10JD3EA?
The error code for “Total running current protection” on the PANASONIC CS-E10JD3EA is F98. The abnormality judgement is “3 times occurrence within 20 minutes” and there is no emergency operation. The primary location to verify is “Excess refrigerant” or “Improper heat radiation”.
What is the error code for “Outdoor Direct Current (DC) peak detection” on the PANASONIC CS-E10JD3EA?
The error code for “Outdoor Direct Current (DC) peak detection” on the PANASONIC CS-E10JD3EA is F99. The abnormality judgement is “7 times occurrence continuously” and there is no emergency operation. The primary location to verify is “Outdoor PCB”, “IPM (Power transistor)”, or “Compressor”.
What are the required materials to be prepared locally for the installation of the PANASONIC CS-E10JD3EA Indoor Unit?
The other items to be prepared locally for the installation of the PANASONIC CS-E10JD3EA Indoor Unit are:
1. Rigid PVC pipe: VP20 (outer diameter ø26); also sockets, elbows and other parts as necessary.
2. Adhesive: PVC adhesive.
3. Insulation: For refrigerant piping insulation: foamed polyethylene with a thickness of 8 mm or more. For drain piping insulation: foamed polyethylene with a thickness of 10 mm or more.
4. Indoor/outdoor connecting cable: 4 x 1.5 mm2 flexible cord, designation type 245 IEC 57 (H05RN-F).
5. Hanging bolt related parts: Hanging bolts (M10) (4) and nuts (12), Flat washers (8) (when hanging the indoor unit).
What are the installation location considerations for the Indoor Unit of the PANASONIC CS-E10JD3EA?
Indoor unit installation location considerations for the PANASONIC CS-E10JD3EA are:
1. Do not install the unit in excessive oil fume area such as kitchen, workshop and etc.
2. The location should be strong enough to support the main unit without vibration.
3. There should not be any heat or steam source nearby.
4. Drainage should be easy. Avoid locating the drain port close to ditches (domestic wastewater).
5. Avoid locations above entrances and exits.
6. Do not block the air intake and discharge passages.
7. Select the location that enables the cool and warm air to spread out to the entire room.
8. Locate the indoor unit at least 1 m or more away from a TV, radio, wireless appliance, antenna cable and fluorescent light, and 2 m or more away from a telephone.
What is the recommended mounting location for the Remote Controller for the PANASONIC CS-E10JD3EA?
The recommended mounting location for the Remote Controller for the PANASONIC CS-E10JD3EA is:
1. Allow sufficient space around the remote controller as shown in the illustration.
2. Install in a place which is away from direct sunlight and high humidity.
3. Install in a flat surface to avoid warping of the remote controller. If installed to a wall with an uneven surface, damage to the LCD case or operation problems may result.
4. Install in a place where the LCD can be easily seen for operation. (Standard height from the floor is 1.2 to 1.5 meters.)
5. Avoid installing the remote controller cable near refrigerant pipes or drain pipes, else it will cause electrical shock or fire.
6. Install the remote controller cable at least 5 cm away from electric wires of other appliances to avoid miss-operation (electromagnetic noise).
What is the procedure to drill a hole in the wall and install a sleeve of piping for the PANASONIC CS-E10JD3EA Indoor Unit?
The procedure to drill a hole in the wall and install a sleeve of piping for the PANASONIC CS-E10JD3EA Indoor Unit is:
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the wall.
4. Finish by sealing the sleeve with putty or caulking compound at the final stage.
If the wall is hollow, be sure to use the sleeve for tube assembly to prevent pests from damaging the cables, e.g. mice biting the connecting cable.
What are the installation considerations for the PANASONIC CS-E10JD3EA Indoor Unit when installation is embedded in the ceiling?
When installing the PANASONIC CS-E10JD3EA Indoor Unit embedded in the ceiling:
1. Always provide sufficient entry and exit space to allow installation work, inspection and unit replacement.
2. Waterproof the rear surface of the ceiling below the unit in consideration of water droplets forming and dropping.
3. When installing into a ceiling, select the unit position and airflow direction that enable the cool and warm air to spread out to the whole room.
4. Do not place objects that might obstruct the airflow within 1 m below the intake grill.
5. The relative positions of the ceiling opening and hanging bolts are shown in the illustrations below. When making an inspection opening below the unit, make a 960 mm x 480 mm opening at the ceiling surface. Also, lead the drain piping, refrigerant piping and indoor/outdoor connecting cables up to the respective piping and cable connection positions.
6. Secure the hanging bolts (M10, locally purchased) firmly in a manner capable of supporting the unit weight.
7. Consult your construction or interior contractor for details on finishing the ceiling opening.
When cooling operation is performed for an extended period under the following conditions, water droplets may form and drop. Attach locally purchased insulation (foamed polyethylene with a thickness of 5 mm or more) to the outside of the indoor unit before installing into the ceiling to improve heat insulation:
- Locations with a dew point inside the ceiling of 23°C or more.
- Kitchens and other locations that produce large amounts of heat and steam.
- Locations where the inside of the ceiling serves as an outside air intake passage.
What is the duct bending allowance for the Discharge side duct when installing the Intake and Discharge Duct Type for the PANASONIC CS-E10JD3EA?
For the Discharge side duct when installing the Intake and Discharge Duct Type for the PANASONIC CS-E10JD3EA, the allowable duct length is 5 m or less including the intake side, and the allowance for duct bends is 90° or less in one location.
What is the required procedure for PREPARING TO INSTALL THE INDOOR UNIT for the PANASONIC CS-E10JD3EA?
The procedure for PREPARING TO INSTALL THE INDOOR UNIT for the PANASONIC CS-E10JD3EA is:
1. Fit the drain hose insulation around the drain hose as shown in the diagram beside.
2. Attach the discharge chamber. ( ) (10 screws).
3. Cut out the intake cut-out portions at the unit rear panel using a cutter or other tools to make openings.
4. Remove the two screws at the rear edge of the unit top panel and attach the intake chamber. ( ) (8 screws).
What is the procedure for Securing the Hanging Bolts for the PANASONIC CS-E10JD3EA Indoor Unit installation?
The procedure for Securing the Hanging Bolts for the PANASONIC CS-E10JD3EA Indoor Unit installation involves securing the hanging bolts (M10) to a ceiling surface, considering reinforcing materials (60 to 90 mm) for wooden structures or utilizing a C channel for securing to a ceiling surface.
How can the High State Switch (SW2) be switched on the control board for the PANASONIC CS-E10JD3EA?
To increase the air volume on the PANASONIC CS-E10JD3EA, open the control box and on the control board, switch the FAN switch (SW2) to “HI”.
What is the procedure for Installation into the Ceiling for the PANASONIC CS-E10JD3EA Indoor Unit?
The procedure for Installation into the Ceiling for the PANASONIC CS-E10JD3EA Indoor Unit is:
1. Attach the nuts and washers to the hanging bolts, then lift up and hook the main unit onto the hanging fixtures.
2. Check if the unit is leveled using a level or a vinyl hose filled partially with water.
What is the procedure for Remote Controller Installation (A. IF REMOTE CONTROLLER CABLE IS EMBEDDED) for the PANASONIC CS-E10JD3EA?
The procedure for Remote Controller Installation (A. IF REMOTE CONTROLLER CABLE IS EMBEDDED) for the PANASONIC CS-E10JD3EA is:
1. Embed an outlet box (JIS C 8336) into the wall. Outlet box maybe purchased separately. Medium size square outlet box (obtain locally) Part No. DS3744 (Panasonic Co., Ltd.) or equivalent.
2. Secure the remote controller lower case to the outlet box with the two accessory screws. Make sure that the lower case is flat against the wall at this time, with no bending.
3. Pass the remote controller cable into the box.
4. Route the remote controller cable inside the lower case through rear feeding-out direction.
5. Insert firmly the connector of remote controller cable to connector (CON1) in the upper case circuit board. (Refer to the illustration at below.)
6. Secure the remote controller upper case to the lower case with the tabs provided.
When the wall is hollow, please be sure to use the sleeve for remote controller cable to prevent dangers caused by mice biting the cable.
What is the procedure for Remote Controller Installation (B. IF REMOTE CONTROLLER CABLE IS EXPOSED) for the PANASONIC CS-E10JD3EA?
The procedure for Remote Controller Installation (B. IF REMOTE CONTROLLER CABLE IS EXPOSED) for the PANASONIC CS-E10JD3EA is:
1. Install the remote controller lower case to the wall with the two accessory screws.
2. Fasten the screws properly until screw head is lower than the rib and reach the base of remote controller lower case to ensure they do not damage the PCB inside the remote controller.
3. The feeding-out direction for the remote controller cable can be either via top, left or right side.
4. Use nipper to cut a notch at the upper case. (Select the intended feeding-out position).
5. Route the remote controller cable inside the lower case in accordance with the intended feeding-out direction. (Refer to the illustration at below).
6. Insert firmly the connector of remote controller cable to connector (CON1) in the upper case circuit board. (Refer to the illustration at below)
7. Secure the remote controller upper case to the lower case with the tabs provided.
What are the requirements for CONNECTING THE DRAIN PIPING for the PANASONIC CS-E10JD3EA Indoor Unit?
The requirements for CONNECTING THE DRAIN PIPING for the PANASONIC CS-E10JD3EA Indoor Unit are:
1. Lay the drain piping so as to ensure drainage.
2. Use a locally purchased VP20 general rigid PVC pipe (outer diameter ø26) for the drain piping and firmly connect the indoor unit and the drain piping using PVC adhesive to ensure that no leakage occurs.
3. Drain piping located indoor should always be insulated by wrapping with locally purchased insulation (foamed polyethylene with a thickness of 10 mm or more).
4. The drain piping should have a downward gradient (1/50 or more) and should be secured by using pipe hanging equipment to avoid creating hills or traps partway.
5. Should there be any obstacle preventing the drain piping from being extended smoothly, the drain piping can be raised outside of the main unit as shown in the illustration below.
Strictly do not install and extend the drain piping from the main unit drain water outlet horizontally or upward or raised it 20 cm or more. Doing so may result in poor drainage or drain motor failure.
What is the Wire Stripping and Connecting Requirement for connecting the Indoor/Outdoor connecting cable on the PANASONIC CS-E10JD3EA?
The Wire Stripping and Connecting Requirement for connecting the Indoor/Outdoor connecting cable on the PANASONIC CS-E10JD3EA is:
1. Wire stripping should have no loose strand when stripping.
2. A gap of 5 mm or more between wires is required at the Indoor/outdoor connection terminal board.
3. The connection of the conductor should be ACCEPT (fully insert), PROHIBITED (conductor not fully insert), and PROHIBITED (conductor not fully insert).
What are the conditions for using additional refrigerant when installing the PANASONIC CS-E10JD3EA CU-E10HBEA Outdoor Unit?
If the piping length is over 10m when installing the PANASONIC CS-E10JD3EA CU-E10HBEA Outdoor Unit, additional refrigerant should be added as shown in the table:
| Model | Piping size | Rated length (m) | Max. Elevation (m) | Min. Piping Length (m) | Max. Piping Length (m) | Additional Refrigerant (g/m) |
|---|---|---|---|---|---|---|
| E10**** | Gas: 3/8” Liquid: 1/4” | 7.5 | 15 | 3 | 20 | 20 |
Example: If the unit is installed at a 12m distance, the quantity of additional refrigerant should be 40 g… (12-10) m × 20 g/m = 40 g.
What is the procedure for “Connecting The Piping To Indoor Unit” for the PANASONIC CS-E10JD3EA?
The procedure for “Connecting The Piping To Indoor Unit” for the PANASONIC CS-E10JD3EA is:
1. Please make flare after inserting flare nut (locate at joint portion of indoor piping) onto the copper pipe. (In case of using long piping).
2. Connect the piping by aligning the center of piping and sufficiently tightening the flare nut with fingers. Further tighten the flare nut with torque wrench in specified torque as stated in the table.
What is the procedure for “Connecting The Piping To Outdoor Unit” for the PANASONIC CS-E10JD3EA?
The procedure for “Connecting The Piping To Outdoor Unit” for the PANASONIC CS-E10JD3EA is:
1. Align the center of the pipings and sufficiently tighten the flare nut with fingers.
2. Finally, tighten the flare nut with torque wrench until the wrench clicks. When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench.
What is the procedure for CUTTING AND FLARING THE PIPING for the PANASONIC CS-E10JD3EA?
The procedure for CUTTING AND FLARING THE PIPING for the PANASONIC CS-E10JD3EA is:
1. Please cut using pipe cutter and then remove the burrs.
2. Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. Turn the piping end down to avoid the metal powder entering the pipe.
3. Please make flare after inserting the flare nut onto the copper pipes.
What is the check item for Earth wire connection on the PANASONIC CS-E10JD3EA after servicing?
One of the check items for the PANASONIC CS-E10JD3EA after servicing is: “Is the Earth wire connection done properly?”.
What is the check item for power supply voltage compliance on the PANASONIC CS-E10JD3EA after servicing?
One of the check items for the PANASONIC CS-E10JD3EA after servicing is: “Is the power supply voltage complied with the rated value?”.
What is the check item for abnormal sound on the PANASONIC CS-E10JD3EA after servicing?
One of the check items for the PANASONIC CS-E10JD3EA after servicing is: “Is there any abnormal sound emitted?”.
What is the check item for cooling/heating operation normality on the PANASONIC CS-E10JD3EA after servicing?
One of the check items for the PANASONIC CS-E10JD3EA after servicing is: “Is the cooling / heating operation normal?”.
What is the check item for thermostat operation normality on the PANASONIC CS-E10JD3EA after servicing?
One of the check items for the PANASONIC CS-E10JD3EA after servicing is: “Is the thermostat operation normal?”.
What is the check item for drainage OK on the PANASONIC CS-E10JD3EA after servicing?
One of the check items for the PANASONIC CS-E10JD3EA after servicing is: “Is the drainage OK? (Refer to the “Check the Drainage” section)”.
What is the check item for Remote Control’s LCD operation normality on the PANASONIC CS-E10JD3EA after servicing?
One of the check items for the PANASONIC CS-E10JD3EA after servicing is: “Is the Remote Control’s LCD operation normal?”.