NATIONAL INSTRUMENTS NI SMB-2147 (01) PDF MANUAL


Post questions, comments, reviews or errors in the comment box below.

Your File is Ready … Download PDF

CLICK HERE TO DOWNLOAD NATIONAL INSTRUMENTS NI SMB-2147 (01) PDF MANUAL


PDF Content Summary: USER GUIDE NI SMB-2145/2146/2147/2148 Shielded Signal Accessories for NI 5751/5752 Adapter Modules The NI SMB-2145/2146/2147/2148 (NI SMB-214x) devices are shielded signal accessories for NI FlexRIOTM digitizer adapter modules (NI 5751 and NI 5752). NI SMB-214x accessories provide easy connections to other devices for testing and debugging. The following table describes each of the accessories. Table 1. NI 214x Signal Accessories Accessory Description NI SMB-2145 NI 5752 analog input accessory NI SMB-2146 NI 5752 digital I/O accessory NI SMB-2147 NI 5751 analog input accessory NI SMB-2148 NI 5751 digital I/O accessory This guide explains how to set up and use NI SMB-214x signal accessories with NI 5751/5752 adapter modules. Contents Conventions ............................................................................................ 2 What You Need to Get Started ............................................................... 2 Related Documentation........................................................................... 3 Parts Locator ........................................................................................... 3 Installing Cables...................................................................................... 5 Connecting Signals ................................................................................. 8 NI SMB-2145 .................................................................................. 9 NI SMB-2146 .................................................................................. 10 NI SMB-2147 .................................................................................. 11 NI SMB-2148 .................................................................................. 12 Cleaning the Accessory........................................................................... 13 Specifications...........................................................................................13 NI SMB-2145 ...................................................................................13 NI SMB-2146 ...................................................................................14 NI SMB-2147 ...................................................................................14 NI SMB-2148 ...................................................................................15 Compliance and Certifications ................................................................16 Environmental Management ............................................................16 Technical Support Resources ..................................................................17 Conventions The following conventions are used in this manual: This icon denotes a note, which alerts you to important information. This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. When this symbol is marked on a product, refer to the Specifications section for information about precautions to take. italic Italic text denotes variables, emphasis, a cross-reference, or an introduction to a key concept. Italic text also denotes text that is a placeholder for a word or value that you must supply. monospace Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames, and extensions. What You Need to Get Started To set up and use the NI SMB-214x, you need the following items: ❑ NI 5751R or NI 5752R, installed in a PXI/PXI Express or CompactPCI chassis Note The NI 5751R and NI 5752R are comprised of an NI FlexRIO FPGA module and an NI FlexRIO adapter module (NI 5751 or NI 5752). NI SMB-2145/2146/2147/2148 User Guide 2 ni.com ❑ The appropriate cable assembly for your adapter module: Table 2. NI SMB-214x Cables Adapter Module/Signal Cable Description Part Number NI 5751 Analog SHC68-C68-D4 196275A-01 NI 5751 Digital SHC68-C68-D4 196275A-01 NI 5752 Analog SHC68-C68-D3 188143B-01 NI 5752 Digital SHC68-C68-D4 196275A-01 ❑ At least one 50 Ω cable with SMB connectors Related Documentation You may find the following documents helpful as you use the NI SMB-214x. • NI 5751R User Guide and Specifications • NI 5752R User Guide and Specifications • NI FlexRIO FPGA Module Installation Guide and Specifications These printed documents provide the specifications for your adapter module and your FPGA module. These documents are also available at ni.com/manuals. Parts Locator Figures 1-4 show the connectors on each of the NI SMB-214x accessories. 1 1

AI 0/16AI 0/16 AI 1/17AI 1/17 AI 2/18AI 2/18 AI 2/18AI 2/18 AI 3/19AI 3/19 AI 3/19AI 3/19 AI 3/19AI 3/19 AI 4/20AI 4/20 AI 5/21AI 5/21 AI 6/22AI 6/22 AI 6/22AI 6/22 AI AI 7/23 7/23 AI AI 7/23 7/23 AI AI 7/23 7/23 AI 8/24AI 8/24 AI 8/24AI 8/24 AI 8/24AI 8/24 AI 8/24AI 8/24 AI AI 12/28 12/28 AI AI 12/28 12/28 AI AI 12/28 12/28 AI AI 12/28 12/28 AI 9/25AI 9/25 AI 9/25AI 9/25 AI 9/25AI 9/25 AI 9/25AI 9/25 AI 9/25AI 9/25 AI AI 13/29 13/29 AI AI 13/29 13/29 AI AI 13/29 13/29 AI AI 13/29 13/29 AI AI 13/29 13/29 AI AI 10/26 10/26 AI AI 10/26 10/26 AI AI 10/26 10/26 AI AI 10/26 10/26 AI AI 10/26 10/26 AI AI 10/26 10/26 AI AI 14/30 14/30 AI AI 14/30 14/30 AI AI 14/30 14/30 AI AI 14/30 14/30 AI AI 14/30 14/30 AI AI 14/30 14/30 AI AI 11/27 11/27 AI AI 11/27 11/27 AI AI 11/27 11/27 AI AI 11/27 11/27 AI AI 11/27 11/27 AI AI 11/27 11/27 AI AI 11/27 11/27 SMB-2145 SMB-2145 Analog Analog Input Input Accessory Accessory SMB-2145 SMB-2145 Analog Analog Input Input Accessory Accessory SMB-2145 SMB-2145 Analog Analog Input Input Accessory Accessory SMB-2145 SMB-2145 Analog Analog Input Input Accessory Accessory SMB-2145 SMB-2145 Analog Analog Input Input Accessory Accessory SMB-2145 SMB-2145 Analog Analog Input Input Accessory Accessory SMB-2145 SMB-2145 Analog Analog Input Input Accessory Accessory AI AI 15/31 15/31 AI AI 15/31 15/31 AI AI 15/31 15/31 AI AI 15/31 15/31 AI AI 15/31 15/31 AI AI 15/31 15/31 AI AI 15/31 15/31 AI AI 15/31 15/31

2 3 1 Analog Inputs <0..31> 2 VHDCI Connector 3 Shield Ground Lug Figure 1. NI SMB-2145 Parts Locator Diagram © National Instruments Corporation 3 NI SMB-2145/2146/2147/2148 User Guide 1 2 DO 0DO 0 DO 1DO 1 DO 2DO 2 DO DO 3 3 DO 9DO 9 DO 10DO 10 DO 11DO 11 SMB-2147 SMB-2147 Analog Analog Input Input Accessory Accessory AI AI 3 3 DO 4DO 4 DO 12DO 12 DO 5DO 5 DO DO 13 13 DO 6DO 6 DO 14DO 14 DO 7DO 7 DO 15DO 15 DI 0DI 0 DI 1DI 1 DO 8DO 8 SMB-2146 SMB-2146 Digital Digital I/O I/O Accessory Accessory 3 4 1 Digital Outputs <0..15> 2 Digital Inputs <0..1> 3 VHDCI Connector 4 Shield Ground Lug 1 Analog Inputs <0..15> 2 VHDCI Connector 3 Shield Ground Lug 1 Digital Outputs <0..7> 2 Digital Inputs <0..7> Figure 2. NI SMB-2146 Parts Locator Diagram 1 AI 15AI 15 AI 14AI 14 AI AI 13 13 AI 12AI 12 AI 7AI 7 AI 6AI 6 AI 5AI 5 AI 4AI 4 AI 11AI 11 AI 10AI 10 AI 9AI 9 AI 8AI 8 AI 2AI 2 AI 1AI 1 AI 0AI 0 2 3 Figure 3. NI SMB-2147 Parts Locator Diagram 1DO 0DO 0 DO 1DO 1 DO 2DO 2 DO DO 3 3 DO 4DO 4 DI 0DI 0 DI 1DI 1 DI 2DI 2 DI DI 3 3 DI 4DI 4 SMB-2148 SMB-2148 Digital Digital I/O I/O Accessory Accessory 2 Figure 4. NI SMB-2148 Parts Locator Diagram DO 5DO 5 DI 5DI 5 DO 6DO 6 DI 6DI 6 DO 7DO 7 DI 7DI 7 3 4 3 VHDCI Connector 4 Shield Ground Lug NI SMB-2145/2146/2147/2148 User Guide 4 ni.com Installing Cables Caution Disconnect power from the adapter module, accessory, and any other connected hardware before connecting the cable to prevent personal injury or damage to the hardware. NI is not liable for damage resulting from improper connections. Complete the following steps to install the cable and any 50 Ω SMB cables. 1. Install the NI 5751R or NI 5752R by following the installation procedure described in the NI FlexRIO FPGA Module Installation Guide and Specifications. 2. Remove power from the adapter module by powering down the PXI/PXI Express or CompactPCI chassis or by programmatically removing power from the adapter module. Power down any external hardware intended for connection to this system. 3. Attach either end of the cable assembly to the VHDCI connector on the front panel of the adapter module and secure the cable with the captive screws on the cable connector. Note Do not use cables other than the cables listed in Table 2 with these accessories. 4. Attach and secure the other end of the cable assembly to the VHDCI connector of the NI SMB-214x and secure them together with the captive screws on the cable connector. © National Instruments Corporation 5 NI SMB-2145/2146/2147/2148 User Guide Figures 5 and 6 show how to connect your NI SMB-214x accessory to your NI FlexRIO system. 1 NI PXI-1042 2 NNAATTIOIONNAAL L 4 5 3

1 PXI Chassis with NI 5752R 2 NI SMB-2145 3 NI SMB-2146 Figure 5. Connecting the NI 5752R to the NI SMB-2145 and NI SMB-2146 4 SHC68-C68-D4 Cable Assembly 5 SHC68-C68-D3 Cable Assembly

NI SMB-2145/2146/2147/2148 User Guide 6 ni.com INSTRUMENTSINSTRUMENTS INSTRUMENTSINSTRUMENTS NATIONAL NATIONAL 1 2 NI PXI-1042 NATIONAL NATIONAL 3 4 4 AAI I 115 5 AAI I 111 1 AAI I 114 4 AI 10 AAI I 13 13 AI AI 99 AAI I 12 12 AAI I 88 AI 10 AAAnnaloaloSg g MInpInpB-2ut ut 14AA7 ccccesessosory ry AI I 77 AAI I 3 3 AAI I 22 INSTRUMENTS SMB-2147 AAI I 66 AAI I 55 AAI I 44 AI AI 11 AAI I 00 1 PXI Chassis with NI 5751R 2 NI SMB-2147 3 NI SMB-2148 4 SHC68-C68-D4 Cable Assemblies Figure 6. Connecting the NI 5751R to the NI SMB-2147 and NI SMB-2148 5. Make signal connections by connecting SMB cables to NI SMB-214x signal terminals. Refer to the Connecting Signals section for more information. Note To ensure a solid ground connection, tighten the SMB connectors by gently snapping them into place. © National Instruments Corporation 7 NI SMB-2145/2146/2147/2148 User Guide INSTRUMENTSINSTRUMENTS NATIONAL 6. Apply power to the adapter module by powering on the PXI/PXIe or Compact PCI chassis or by programmatically applying power to the adapter module. 7. Power on any external hardware intended for use with this system. Connecting Signals The NI SMB-214x provides signal connectivity to the NI 5751/5752 adapter module. You can connect to these signals from the labeled SMB connectors on the NI SMB-214x. Caution Connections that exceed any of the maximum ratings for the NI SMB-214x or the NI 5751/5752 adapter module can damage the device and the computer. Maximum input ratings are provided in the specifications document that shipped with the adapter module. NI is not liable for any damages resulting from such signal connections. Figures 7 through 10 show the pinouts of the VHDCI connectors of NI SMB-214x accessories. The analog inputs, digital inputs, and digital outputs are connected to corresponding pins on the NI SMB-214x. Refer to Table 3 for the pin descriptions. Table 3. VHDCI Connector Pinout Descriptions Pin Signal Description AI <0..31> Analog input channels 0 through 31 DI <0..15> Digital input channels 0 through 15 DO <0..15> Digital output channels 0 through 15 GND Ground reference for signals RSVD Reserved for system use. Do not connect signals to these channels. NI SMB-2145/2146/2147/2148 User Guide 8 ni.com NI SMB-2145 GND 135GND AI 0/16 236GND GND 337AI 1/17 GND 438GND AI 2/18 539GND GND 640AI 3/19 GND 741GND AI 4/20 842GND GND 943AI 5/21 GND 1044GND AI 6/22 1145GND GND 1246AI 7/23 GND 1347GND AI 8/24 1448GND GND 1549AI 9/25 GND 1650GND AI 10/26 1751GND GND 1852AI 11/27 GND 1953GND AI 12/28 2054GND GND 2155AI 13/29 GND 2256GND AI 14/30 2357GND GND 2458AI 15/31 GND 2559GND GND 2660GND GND 2761GND GND 2862GND GND 2963GND GND 3064GND GND 3165GND GND 3266GND GND 3367GND GND 34 68 GND Figure 7. NI SMB-2145 VHDCI Connector Pinout © National Instruments Corporation 9 NI SMB-2145/2146/2147/2148 User Guide NI SMB-2146 RSVD 135GND 236RSVD 337GND 438RSVD 539GND 640RSVD 741RSVD 842RSVD 943GND 1044RSVD 1145GND 1246RSVD 1347GND 1448DI 1 1549GND 1650DO 15 1751GND 1852DO 13 1953GND 2054DO 11 2155GND 2256DO 9 2357GND 2458DO 7 2559RSVD 2660DO 5 2761GND 2862DO 3 2963RSVD 3064DO 1 3165GND 3266RSVD 3367GND 34 68 Figure 8. NI SMB-2146 VHDCI Connector Pinout RSVD GND RSVD GND RSVD GND RSVD GND RSVD GND RSVD GND RSVD GND DI 0 GND DI 14 RSVD DO 12 GND DO 10 GND DO 8 GND DO 6 RSVD DO 4 GND DO 2 RSVD DO 0 GND RSVD GND NI SMB-2145/2146/2147/2148 User Guide 10 ni.com NI SMB-2147 AI 0 135RSVD GND 236GND RSVD 337AI 1 GND 438GND AI 2 539RSVD GND 640GND RSVD 741AI 3 RSVD 842GND AI 4 943RSVD GND 1044GND RSVD 1145AI 5 GND 1246GND AI 6 1347RSVD GND 1448GND RSVD 1549AI 7 GND 1650GND AI 8 1751RSVD GND 1852RSVD RSVD 1953AI 9 GND 2054GND AI 10 2155RSVD GND 2256GND RSVD 2357AI 11 GND 2458GND AI 12 2559RSVD RSVD 2660RSVD RSVD 2761AI 13 GND 2862GND AI 14 2963RSVD RSVD 3064RSVD RSVD 3165AI 15 GND 3266GND RSVD 3367RSVD GND 34 68 GND Figure 9. NI SMB-2147 VHDCI Connector Pinout © National Instruments Corporation 11 NI SMB-2145/2146/2147/2148 User Guide NI SMB-2148 RSVD 135GND 236RSVD 337GND 438RSVD 539GND 640RSVD 741RSVD 842RSVD 943GND 1044RSVD 1145GND 1246RSVD 1347GND 1448RSVD 1549GND 1650DI 7 1751GND 1852DI 5 1953GND 2054DI 3 2155GND 2256DI 1 2357GND 2458DO 7 2559RSVD 2660DO 5 2761GND 2862DO 3 2963RSVD 3064DO 1 3165GND 3266RSVD 3367GND 34 68 Figure 10. NI SMB-2148 VHDCI Connector Pinout Note For additional shielding, you can connect the shield ground connector on the NI SMB-214x to earth/hard ground. This terminal is connected to the shielded enclosure ground. The shield ground lug is shown in Figures 1 through 4. RSVD GND RSVD GND RSVD GND RSVD GND RSVD GND RSVD GND RSVD GND RSVD GND DI 6 RSVD DI 4 GND DI 2 GND DI 0 GND DO 6 RSVD DO 4 GND DO 2 RSVD DO 0 GND RSVD GND NI SMB-2145/2146/2147/2148 User Guide 12 ni.com Cleaning the Accessory Disconnect all cables to the NI SMB-214x before cleaning. To remove light dust, use a soft, nonmetallic brush. To remove other contaminants, use alcohol wipes. The unit must be completely dry and free from contaminants before returning to service. Specifications These specifications are characteristic at 25 °C unless otherwise noted. NI SMB-2145 Analog Input Analog input channels............................ 16, single-ended Typical propagation delay through NI SMB-2145 ........................... 1.2 ns Typical channel-to-channel skew........... ±35 ps Typical trace characteristic impedance ........................ 50 Ω Maximum voltage rating........................ 5.5 V or the maximum input voltage of the NI 5752 analog inputs, whichever is less Physical Dimensions............................................. 30.5 cm × 4.5 cm × 26.5 cm (12.0 in. × 1.77 in. × 10.43 in.) Weight.................................................... 1,380 g (48.7 oz.) I/O connectors ........................................ One 68-pin VHDCI connector, 16 SMB jack connectors, one banana-style connector © National Instruments Corporation 13 NI SMB-2145/2146/2147/2148 User Guide NI SMB-2146 Digital I/O Digital output channels...........................16, single-ended Digital input channels.............................2, single-ended Typical propagation delay through NI SMB-2146............................1.2 ns Typical channel-to-channel skew ...........±35 ps Typical trace characteristic impedance.........................50 Ω Maximum voltage rating ........................5.5 V or the maximum input voltage of the NI 5752 digital inputs, whichever is less Physical Dimensions .............................................30.5 cm × 4.5 cm × 26.5 cm (12.0 in. × 1.77 in. × 10.43 in.) Weight ....................................................1,380 g (48.7 oz.) I/O connectors.........................................One 68-pin VHDCI connector, 18 SMB jack connectors, one banana-style connector NI SMB-2147 Analog Input Analog input channels ............................16, single-ended Typical propagation delay through NI SMB-2147............................1.2 ns Typical channel-to-channel skew ...........±35 ps Typical trace characteristic impedance.........................50 Ω Maximum voltage rating ........................5.5 V or the maximum input voltage of the NI 5751 analog inputs, whichever is less NI SMB-2145/2146/2147/2148 User Guide 14 ni.com Physical Dimensions............................................. 30.5 cm × 4.5 cm × 26.5 cm (12.0 in. × 1.77 in. × 10.43 in.) Weight.................................................... 1,380 g (48.7 oz.) I/O connectors ........................................ One 68-pin VHDCI connector, 16 SMB jack connectors, one banana-style connector NI SMB-2148 Digital I/O Digital input channels ............................ 8, single-ended Digital output channels .......................... 8, single-ended Typical propagation delay through NI SMB-2148 ........................... 1.2 ns Typical channel-to-channel skew........... ±35 ps Typical trace characteristic impedance ........................ 50 Ω Maximum voltage rating........................ 5.5 V or the maximum input voltage of the NI 5751 digital inputs, whichever is less Physical Dimensions............................................. 30.5 cm × 4.5 cm × 26.5 cm (12.0 in. × 1.77 in. × 10.43 in.) Weight.................................................... 1,380 g (48.7 oz.) I/O connectors ........................................ One 68-pin VHDCI connector, 16 SMB jack connectors, one banana-style connector © National Instruments Corporation 15 NI SMB-2145/2146/2147/2148 User Guide Compliance and Certifications Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the NI and the Environment Web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste Electrical and Electronic Equipment, visit ni.com/environment/weee. 电子信息产品污染控制管理办法 ˄中国 RoHS) 中国客户 National Instruments ヺড়Ё೑⬉ᄤֵᙃѻકЁ䰤ࠊՓ⫼ɨѯ᳝ᆇ⠽䋼ᣛҸ (RoHS)DŽ ݇Ѣ National Instruments Ё೑ RoHS ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) NI SMB-2145/2146/2147/2148 User Guide 16 ni.com Technical Support Resources The National Instruments Web site is your complete resource for technical support. At ni.com/support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at ni.com/support and follow the calling instructions or dial 512 795 8248. For telephone support outside the United States, contact your local branch office: Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800, Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, Finland 358 (0) 9 725 72511, France 01 57 66 24 24, Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737, Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710, Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466, New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, Poland 48 22 328 90 10, Portugal 351 210 311 210, Russia 7 495 783 6851, Singapore 1800 226 5886, Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197, Spain 34 91 640 0085, Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, Taiwan 886 02 2377 2222, Thailand 662 278 6777, Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545 © National Instruments Corporation 17 NI SMB-2145/2146/2147/2148 User Guide LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments Corporation. Refer to the Trademark Information at ni.com/trademarks for other National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. © 2010 National Instruments Corporation. All rights reserved. 375568A-01 May10


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE - USER MANUAL

OWNER GUIDE - OWNER MANUAL

REFERENCE GUIDE - REFERENCE MANUAL

INSTRUCTION GUIDE - INSTRUCTION MANUAL

Leave a Reply