MRCOOL VERSA PRO MVP-60-HP-230-00 (01) Image

Free English MRCOOL VERSA PRO MVP-60-HP-230-00 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD MRCOOL VERSA PRO MVP-60-HP-230-00 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What models are covered in the installation and owner’s manual for the MRCOOL VERSA PRO MVP-60-HP-230-00?

The manual covers the following models:

CONDENSER:

MVP-36-HP-C-230-00

MVP-48-HP-C-230-00

MVP-60-HP-C-230-00

AIR HANDLER:

MVP-36-HP-MUAH-230-00

MVP-48-HP-MUAH-230-00

MVP-60-HP-MUAH-230-00

COMPLETE SYSTEM:

MVP-36-HP-230-00

MVP-48-HP-230-00

MVP-60-HP-230-00


What are the refrigerant line set connection options and requirements for the MRCOOL VERSA PRO MVP-60-HP-230-00?

The MRCOOL VERSA PRO MVP-60-HP-230-00 (a 36K/48K/60K Capacity Unit) is designed to be installed using either a traditional flare nut configuration of refrigerant piping or the optional MRCOOL® No-Vac® Quick Connect® Pre-Charged Line Set.

If the optional No-Vac Quick Connect Line Set is used, you DO NOT have to retain the services of a professional HVAC installer.

If the traditional flare nut configuration is selected, you ARE REQUIRED to retain the services of a professional HVAC installer. Stub pipes and copper nuts are included with these capacity units to complete this type of installation.

If any other form of installation is attempted, or these stipulations are not followed, the warranty will be voided.

DISCLAIMER: You are assuming risk by handling materials containing refrigerants under pressure, that if not handled properly, can cause bodily injury. If you do not feel comfortable conducting this installation process, we recommend you retain the services of a qualified HVAC professional. Electrical work must be completed by a qualified electrical technician.


What are the key safety warnings for installing the MRCOOL VERSA PRO MVP-60-HP-230-00?

Installation must be performed by an authorized dealer or specialist. Defective installation can cause water leakage, electrical shock, or fire. Electrical work must be completed by a qualified electrical technician.

DO NOT install the unit in a location that may be exposed to combustible gas leaks. If combustible gas accumulates around the unit, it could cause fire.

DO NOT turn on the power until the installation and all work has been completed.

DO NOT install a unit equipped with an auxiliary electric heater within 3 ft (1 m) of any combustible materials.

1. Installation must be performed according to the installation instructions. Improper installation could cause water leakage, electrical shock, fire, and could void the warranty. (In North America, all wiring/electrical work must be performed in accordance with the requirements of NEC and CEC by authorized personnel only.)

2. Contact an authorized service technician for repair or maintenance of this unit. This appliance must be installed in accordance with national wiring regulations.

3. Only use the included accessories, parts, and specified parts for installation. Using non-standard parts can cause water leakage, electrical shock, fire, and/or failure of the unit.

4. Install the unit in a firm location that can support the unit’s weight. If the location cannot support the unit’s weight, or the installation is not done properly, the unit may drop and cause serious injury and damage.

5. Install the drainage piping according to the instructions in this manual. Improper drainage could cause water damage to your home and/or property.

6. When moving or relocating the air conditioner, consult experienced service technicians for disconnection and re-installation of the unit.

7. For detailed information of how to install the indoor and outdoor units to their respective supports, please refer to the indoor unit installation and outdoor unit installation sections of this manual.

8. Excessive Weight Hazard: Use two or more people when moving and installing the unit. Failure to do this could result in personal injury.


What are the warnings for product use of the MRCOOL VERSA PRO MVP-60-HP-230-00?

DO NOT insert fingers, rods, or other objects into the air inlet or outlet. This could cause injury, since the fan may be rotating at high speeds.

DO NOT use flammable sprays such as hair spray, lacquer or paint near the unit, as this could cause fire and/or an explosion.

DO NOT operate the unit in places near or around combustible gases. Emitted gas may collect around the unit and cause an explosion.

DO NOT allow children to play with the appliance. Children must be supervised around the unit at all times.

DO NOT operate the unit in a room where it could be exposed to excessive amounts of water, such as a bathroom or laundry room. Exposure to excessive water amounts can cause the electrical components to short circuit.

DO NOT expose your body directly to direct cool airflow from the unit for a prolonged period of time.

1. If the unit operates abnormally (emits strange noises or a burning smell), immediately turn off the unit and disconnect the power in order to avoid electric shock, fire, and/or injury. Call your local dealer for further assistance.

2. If the air conditioner is used together with burners or other heating devices, thoroughly ventilate the room in order to avoid an oxygen deficiency.

3. In certain functional environments (such as kitchens and server rooms etc.), the use of specially designed air-conditioning units is highly recommended.

4. This appliance can be used by children (8 years and older) and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge if they have been given instruction concerning the use of the appliance and understand the hazards involved.

5. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a licensed professional HVAC installer, service agency, or the gas supplier.


What are the electrical warnings for the MRCOOL VERSA PRO MVP-60-HP-230-00?

Electrical work must be completed by a qualified electrical technician.

DO NOT share the power supply with other appliances. An improper or insufficient power supply could cause fire and/or electrical shock.

1. The product must be properly grounded during installation or electrical shock could occur.

2. Appropriate wiring standards, regulations, and the installation manual must be followed for all electrical work.

3. If connecting power to fixed wiring, an all-pole disconnection device must be incorporated in the fixed wiring in accordance with the wiring rules and must meet the following requirements: at least 3 mm of clearances in all poles, a leakage current that may exceed 10 mA, and a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.

4. For all electrical work, fuse the specified cables. Connect cables tightly and clamp them securely to prevent external forces from damaging the terminal. Improper electrical connections could overheat, causing fire and/or electrical shock.

5. All electrical connections must be made according to the Electrical Connection Diagram located on the panels of the indoor and outdoor units.

6. All wiring must be properly arranged to ensure that the control board cover can close properly. If the control board cover is not properly closed, it can lead to corrosion and cause the connection points on the terminal to heat up, catch fire, or cause electrical shock.


How should I clean and maintain the MRCOOL VERSA PRO MVP-60-HP-230-00?

WARNING FOR CLEANING & MAINTENANCE

DO NOT clean the unit with excessive amounts of water.

DO NOT clean unit with combustible cleaning agents, as these could cause deformation and/or fire.

1. Turn off the device and disconnect the power before cleaning. Failure to do this could result in electrical shock.

CAUTION

DO NOT allow the air conditioner to operate for extended periods of time with the doors or windows open, or in very high humidity.

DO NOT operate the air conditioner with wet hands, as this could cause electric shock.

DO NOT use device for any other purpose than its intended use.

DO NOT climb onto or place objects on top of the outdoor unit.

1. Make sure that water condensation can drain smoothly and unhindered from the unit.

2. Turn off the unit and disconnect the power if the unit will not be used for an extended period of time.

3. As with any mechanical equipment, contact with sharp metal edges can result in personal injury. Ensure care is taken when handling the unit and any of its accessories by wearing gloves and protective clothing.


What are the fuse specifications for the MRCOOL VERSA PRO MVP-60-HP-230-00?

The unit’s circuit board (PCB) is designed with a fuse to provide over-current protection. This fuse must be replaced with an identical component if the existing fuse is blown.

The specifications of the fuse are printed on the circuit board, examples of such are T5A/250VAC and T10A/250VAC.


What is the allowed static pressure range for the MRCOOL VERSA PRO MVP-60-HP-230-00?

The allowed static pressure range of the air conditioner on site is 0.00-0.80 in H2O (0-200 Pa).

The data below represents the static pressures at the full required airflow used for AHRI testing.

Model 18-24K 30-36K 48-60K
Pressure 0.5 in H2O (125 Pa) 0.5 in H2O (125 Pa) 0.5 in H2O (125 Pa)

NOTE: The maximum functional total external static pressure cannot exceed 0.80 in WC (200 Pa). The airflow reduces significantly with pressures above and beyond 0.80 in WC (200 Pa). The system design should allow for the increased resistance of filters as they become dirty.


What accessories are included with the MRCOOL VERSA PRO MVP-60-HP-230-00?

The following accessories and parts are included. Use all installation parts and accessories to properly install the system.

PART QUANTITY
Owner’s & Installation Manual 1
Remote Control 1
Remote Control Manual 1
Batteries 2
Wired Thermostat 1
Thermostat Manual 1
Cable Ties 2
Foam Insulator 4
Stub Pipe (Optional) 2 packed with indoor unit, 2 packed with outdoor unit 4 total: 3/8″ (1 with indoor / 1 with outdoor), 3/4″ (1 with indoor / 1 with outdoor)

Included Optional Accessories:

PART QUANTITY
Drain Fitting (In Outdoor Packaging) 1
Seal (In Outdoor Packaging) 1
Flare Nut (In Indoor Packaging) 1

Where should I NOT install the indoor unit of the MRCOOL VERSA PRO MVP-60-HP-230-00?

DO NOT install the indoor unit in any of the following locations:

Areas where oil drilling or fracking is being performed.

Coastal areas with high salt content in the air.

Areas with caustic gases in the air, such as near laundry vents.

Areas with strong electromagnetic waves.

Areas where flammable materials or gas are stored.

Rooms with high humidity, such as bathrooms or laundry rooms.

Areas where the air inlet and outlet may be obstructed.


What are the installation location requirements for the indoor unit of the MRCOOL VERSA PRO MVP-60-HP-230-00?

The indoor unit should be installed in a location that meets the following requirements:

✓ Enough room for the installation and maintenance to be performed.

✓ Enough room for the refrigerant piping and drain pipe.

✓ On a structure that can support its weight. If the structure is too weak, the unit may fall and cause personal injury, unit and property damage, or death.

✓ At least 18 inches (46 cm) above the floor for a garage installation. Failure to follow these instructions can result in death, explosion, or fire.

✓ If suspended, the structure must support the weight of the unit.

✓ The ceiling is horizontal and its structure can sustain the weight of the indoor unit.

✓ The air inlet and outlet are not impeded.

✓ Room for properly sized return and supply ducts must be maintained.

✓ There is no direct radiation from heaters.


What are the dimensions and clearance requirements for the indoor unit of the MRCOOL VERSA PRO MVP-60-HP-230-00?

Clearance Requirements:

For horizontal installations, a minimum clearance of 1 in (25.4 mm) on all sides is required.

For vertical and horizontal installations, a minimum clearance of 24 inches is required at the front for service access.

Unit Dimensions:

Dimensions Model Capacity (BTU/H)
60K
Length of A 53 in (1346 mm)
Length of B 21 in (533 mm)
Length of C 24.5 in (622 mm)
Length of D 22.8 in (580 mm)
Length of E 10.25 in (260 mm)

Filter Dimensions:

Model Capacity (BTU/H) Width (W) Depth (D) Thickness (t)
60K 23 in (584.2 mm) 20 in (508 mm) .96 in (25.4 mm)

What are the guidelines for ductwork and connections for the MRCOOL VERSA PRO MVP-60-HP-230-00?

Air supply and return can be handled in one of several ways depending on which is best suited for the type of installation. The vast majority of problems encountered with combination cooling systems can be linked to improperly designed or installed ductwork. For this reason, it is highly important that the duct system be properly designed and installed.

The use of flexible duct collars will minimize the transmission of vibration and noise into the conditioned space. In an installation where the return air duct is short, or where sound is likely to be a problem, a sound absorbing liner should be used inside the duct.

Insulation of the ductwork is a requirement anywhere it runs through an uncooled space during the cooling season.

The use of a vapor barrier is recommended to prevent absorption of moisture from the surrounding air into the insulation.

The supply air duct should utilize a properly sized transition in order to match the unit opening.

All ducts should be suspended using flexible hangers and never fastened directly to the structure. This unit is not designed for non-ducted (free-blow) applications.

Ductwork should be fabricated and installed in accordance with local and/or national codes.

A field-fabricated secondary drain pan (not included), with a drain pipe to the outside of the building is required in all installations over a finished living space or in any area that may be damaged by overflow from the main drain pan. NOTE: A secondary drain pan is required for horizontal installations.


How do I configure the MRCOOL VERSA PRO MVP-60-HP-230-00 for a horizontal right or downflow installation?

The unit can be installed in a Vertical (downflow or upflow) or a Horizontal (right or left) configuration. Vertical Up and Horizontal Left installation does not require changing the direction of the evaporator. For Horizontal Right or Downflow configurations, follow these steps:

Step 1. Remove the filter door, then remove the filter.

Step 2. Remove the upper cover assembly.

Step 3. Remove the evaporator cover plate by removing the bottom cover first, then the second cover plate.

Step 4. Identify the position of the evaporator’s temperature sensors (T1, T2, T2A, T2B) and Electronic Expansion Valve (EEV).

Step 5. Unplug temperature sensors T1, T2, T2A, and T2B from the control board.

Step 6. Remove the T1 and T2 sensor wire ties.

Step 7. Take out the evaporator and drain pan and rotate them 180°.

Step 8. Adjust the mounting parts positioning according to the new direction of the unit.

Step 9. Reinstall the evaporator and drain pan.

Step 10. Reconnect the T1, T2, T2A, and T2B sensor plugs and the electronic expansion valve (EEV) plug. Tie up the sensor wires. The evaporator is now assembled in place. This includes cutting a foam gasket, removing knockouts, routing the wire through the buckle and slot, and replacing the foam gasket over the wires. The wire body needs to pass through the wire groove from the drain pan and attach to the hook on the drain pan.

Step 11. Use cable ties to attach the room temperature sensor as shown in the diagram.

Step 12. Reinstall the evaporator cover plate.

Step 13. Connect the wiring according to the wiring diagram.

Step 14. Reassemble the upper cover and reinstall the filter and filter cover plate.

Step 15. Connect the refrigerant pipes and install drainage pipes.


What are the requirements for the condensate drain trap for the MRCOOL VERSA PRO MVP-60-HP-230-00 in Upflow and Horizontal Left configurations?

The unit operates with a negative pressure at the drain connections, so a drain trap is required. The trap must be installed as close to the unit as possible. Make sure the top of the trap is below the connection to the drain pan to allow complete drainage.

On units of this type in which the blower “draws” in air rather than “blows” air through the coil, traps must be installed in the condensate drain lines (primary and auxiliary, if used). Traps prevent the blower from drawing air through the drain lines into the air supply.

Horizontal runs must also have an anti-siphon air vent (standpipe) installed ahead of the horizontal run to eliminate air trapping.

The drainpipe outlet should be at least 1.9 in (5 cm) above the ground. If it touches the ground, the unit may become blocked and malfunction.


What are the refrigerant pipe length, elevation, and oil trap requirements for the MRCOOL VERSA PRO MVP-60-HP-230-00?

Maximum Length and Drop Height:

Model Capacity (BTU/H) Maximum Length of Piping Maximum Drop Height
36K/48K/60K 213 ft (65 m) 98.4 ft (30 m)

Oil Trap Requirements:

If oil flows back into the outdoor unit’s compressor, this may cause liquid compression or deterioration of the oil return. Oil traps in the rising gas pipe can prevent this.

For units greater than 36,000Btu/h, an oil trap should be installed every 10m (32.8ft) of vertical suction line riser.

Connecting Pipe Assembly Sizes:

Shape Quantity
Liquid Side Φ6.35 (1/4in)
Φ9.52 (3/8in)
Φ12.7 (1/2in)
Parts must be purchased separately. Consult your dealer or technician about the proper pipe size for the unit you purchased.
Gas Side Φ16 (5/8in)
Φ19 (3/4in)
Φ22 (7/8in)

How do I connect the refrigerant piping for the MRCOOL VERSA PRO MVP-60-HP-230-00?

Insulate both the gas and liquid piping to prevent condensation. All field piping must be completed by a licensed technician.

Step 1: Cut Pipes

Measure the distance between the indoor and outdoor units. Using a pipe cutter, cut the pipe a little longer than the measured distance. Make sure the pipe is cut at a perfect 90° angle. Do not deform the pipe while cutting.

Step 2: Remove Burrs

Burrs can affect the air-tight seal and must be completely removed. Hold the pipe at a downward angle to prevent burrs from falling into the pipe. Use a reamer or deburring tool to remove all burrs from the cut section.

Step 3: Flare Pipe Ends

Proper flaring is essential for an airtight seal.

1. After removing burrs, seal the ends with PVC tape to prevent foreign materials from entering.

2. Sheath the pipe with insulating material.

3. Place flare nuts on both ends of the pipe, facing the right direction.

4. Remove PVC tape when ready to flare.

5. Place a flaring tool onto the form.

6. Turn the handle of the flaring tool clockwise until the pipe is fully flared. Inspect the pipe end for cracks and even flaring.

Step 4: Connect Pipes

Connect the copper pipes to the indoor unit first, then to the outdoor unit. Connect the low-pressure pipe first, then the high-pressure pipe.

1. When connecting the flare nuts, apply a thin coat of refrigeration oil to the flared ends of the pipes.

2. Align the center of the two pipes to be connected.

3. Tighten the flare nut snugly by hand.

4. Using a wrench, grip the nut on the unit tubing. While firmly gripping the nut, use a torque wrench to tighten the flare nut according to the specified torque values.

Pipe gauge Tightening torque
Φ 6.35 (Ø 1/4″) 18-20 N.m (180-200kgf.cm)
Φ 9.52 (Ø 3/8″) 32-39 N.m (320-390kgf.cm)
Φ 12.7 (Ø 1/2″) 49-59 N.m (490-590kgf.cm)
Φ 16 (Ø 5/8″) 57-71 N.m (570-710kgf.cm)
Φ 19 (Ø 3/4″) 67-101 N.m (670-1010kgf.cm)
Φ 22 (Ø 7/8″) 85-110 N.m (850-1100kgf.cm)

5. After connecting the pipes, wrap the power cable, signal cable, and piping together with binding tape. Thread the pipeline through the wall, and insulate all piping, including the outdoor unit valves.

6. Open the stop valves of the outdoor unit to start the flow of refrigerant. Check for leaks.


How do I install an optional Electric Heat Kit in the MRCOOL VERSA PRO MVP-60-HP-230-00?

Installation must be performed by a licensed contractor. Before installation, confirm the electric auxiliary heat module and supplied accessories are present and free of damage.

Step 1: Open the upper cover of the indoor unit.

Step 2: Use tools to remove the knock-out holes of the upper cover.

Step 3: Remove the terminal block and power wires, loosen the screws, and remove the electric auxiliary heating cover.

Step 4: Install the electric auxiliary heating assembly through the front. Note that the support assembly must lock into the support holes in the back of the cabinet.

Step 5: Tighten the mounting screws.

Step 6: Wire according to the wiring nameplate. Apply the wiring diagram to the inside cover for future reference and maintenance.

Step 7: Install the upper cover and the silicone breaker cover.

Step 8: After installing the electric auxiliary heat module, apply the circuit breaker label near the silicone breaker cover previously installed.


What are the electrical specifications for the MRCOOL VERSA PRO MVP-60-HP-230-00 without an electric heat kit?

Use copper wire only to connect the unit. The specification may vary between models, so refer to the indoor unit’s nameplate.

Unit Size Volts-Phase Rated Current (A) Minimum Circuit Amps Branch Circuit
Minimum Wire Size AWG Fuse/Circuit Breaker Amps
60K 208/230-1 7.0 9.0 14# 15.0

How do I select a location for the outdoor unit of the MRCOOL VERSA PRO MVP-60-HP-230-00?

Before installing the outdoor unit, choose an appropriate location based on these standards:

Meets Spatial Requirements:

24in (60cm) above

12in (30cm) on left

24in (60cm) on right

12in (30cm) from back wall

79in (200cm) in front

Firm & Solid: The location must support the unit without vibration.

Low Noise: Noise from the unit will not disturb other people.

Good Air Circulation: The location should have good air circulation and ventilation.

Snowfall: Where snowfall is anticipated, take appropriate measures to prevent ice buildup and coil damage. The outdoor unit must be installed on a riser of at least 6in (15cm) in height or per local code to get the unit above local mean snow fall.

Do NOT install the unit in the following locations:

Near an obstacle that will block air inlets and outlets.

In a location that is exposed to large amounts of dust.

Near animals or plants that will be harmed by hot air discharge.

Near any source of combustible gas.

Near a public street, crowded areas, or where noise from the unit can disturb others.


How do I prepare the outdoor unit of the MRCOOL VERSA PRO MVP-60-HP-230-00 for extreme weather?

If the unit is exposed to heavy wind, install it so that the air outlet fan is at a 90° angle to the direction of the wind. If needed, build a barrier (wind baffle) in front of the unit to protect it from extremely heavy winds.

If the unit is frequently exposed to heavy rain or snow, build a shelter above the unit to protect it. Be careful not to obstruct air flow around the unit.


How do I install the drain fitting on the outdoor unit of the MRCOOL VERSA PRO MVP-60-HP-230-00?

Step 1: Find the base pan hole on the outdoor unit.

Step 2:

Fit the rubber seal on the end of the drain fitting that will connect to the outdoor unit.

Insert the drain fitting into the hole in the base pan of the unit. The drain fitting will click into place.

Connect a drain hose extension (not included) to the drain fitting to redirect water from the unit during heating mode.

In Cold Climates: Make sure the drain hose is as vertical as possible to ensure swift water drainage. If water drains too slowly, it can freeze inside the hose and flood the unit.


How do I anchor the outdoor unit of the MRCOOL VERSA PRO MVP-60-HP-230-00?

If installing the unit on the ground or a concrete mounting platform:

1. Mark the positions for four expansion bolts based on the dimensions chart.

2. Pre-Drill holes for expansion bolts.

3. Place a nut on the end of each expansion bolt.

4. Hammer expansion bolts into the pre-drilled holes.

5. Remove the nuts from expansion bolts, and place the outdoor unit on the bolts.

6. Put a washer on each expansion bolt, then replace the nuts.

7. Using a wrench, tighten each nut until snug.

If installing the unit on a wall-mounted bracket:

1. Mark the position of the bracket holes based on the dimensions chart.

2. Pre-Drill holes for expansion bolts.

3. Place a washer and nut on the end of each expansion bolt.

4. Thread expansion bolts through the holes in the mounting brackets, put mounting brackets into position, and hammer the expansion bolts into the wall.

5. Check that the mounting brackets are level.

6. Carefully lift the unit and place its mounting feet on the brackets.

7. Bolt the unit firmly to the brackets.

8. If allowed, install the unit with rubber isolator pads to reduce vibrations and noise.

Make sure the wall is made of solid brick, concrete, or of similarly strong material. The wall must be able to support at least four times the weight of the unit.


What are the general wiring precautions for the MRCOOL VERSA PRO MVP-60-HP-230-00?

Before performing any electrical work, read these warnings:

BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAIN POWER TO THE SYSTEM.

All wiring must comply with local and national electrical codes, regulations, and must be installed by a licensed electrician.

All electrical connections must be made according to the Electrical Connection Diagram located on the panels of the indoor and outdoor units.

If there is a serious safety issue with the power supply, stop work immediately. Do not resume the install until the safety issue is properly resolved.

Power voltage should be within 90-110% of rated voltage. Insufficient power supply can cause malfunction, electrical shock, or fire.

Installation of an external surge suppressor at the outdoor disconnect is recommended.

If connecting power to fixed wiring, a switch or circuit breaker that disconnects all poles and has a contact separation of at least 1/8in (3mm) must be incorporated in the fixed wiring. The qualified technician must use an approved circuit breaker or switch.

Only connect the unit to an individual branch circuit. Do not connect another appliance to that circuit.

Make sure to properly ground the unit.

Every wire must be firmly connected. Loose wiring can cause the terminal to overheat, resulting in product malfunction and possible fire.

Do not let wires touch or rest against refrigerant tubing, the compressor, or any moving parts within the unit.

To avoid getting electric shock, never touch the electrical components soon after the power supply has been turned off. After turning off the power, always wait 10 minutes or more before you touch the electrical components.

Ensure electrical wiring does not cross with signal wiring. This may cause distortion, interference, or possibly damage the circuit boards.

No other equipment should be connected to the same power circuit.

Connect the outdoor wires before connecting the indoor wires.


How do I wire the outdoor unit of the MRCOOL VERSA PRO MVP-60-HP-230-00?

BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAIN POWER TO THE SYSTEM.

Step 1: Prepare the cable for connection

1. You must first choose the right cable size.

2. Using wire strippers, strip the rubber jacket from both ends of the signal cable to reveal approximately 5.9in (15cm) of wire.

3. Strip the insulation from the ends.

4. Stranded wire requires u-lugs or ring terminals to be crimped onto the ends of the wire.

Step 2: Access the terminal block

Remove the electrical box cover of the outdoor unit. If there is no cover, take off the bolts from the maintenance board and remove the protection board.

Step 3: Connect the wires

1. Match the wire colors/labels with the labels on the terminal block. Firmly screw the u-lug of each wire to its corresponding terminal (L1, L2).

2. Clamp down the cable with the cable clamp.

3. Insulate unused wires with electrical tape. Keep them away from any electrical or metal parts.

4. Reinstall the cover of the electrical control box.


How do I wire the indoor unit of the MRCOOL VERSA PRO MVP-60-HP-230-00?

While connecting the wires, strictly follow the wiring diagram. The refrigerant circuit can become very hot; keep the interconnection cable away from the copper tube.

Step 1: Prepare the cable for connection.

1. Using wire strippers, strip the rubber jacket from both ends of the signal cable to reveal about 5.9in (15cm) of the wire.

2. Strip the insulation from the ends of the wires.

Step 2: Open the front panel.

1. Open the front panel of the indoor unit. Using a screwdriver, remove the cover of the electric control box on your indoor unit.

Step 3: Connect the wires to the terminals.

1. Thread the power cable and the signal cable through the wire outlet.

2. Match the wire colors/labels with the labels on the terminal block. Firmly screw the wires of each wire to its corresponding terminal. Refer to the Wiring Diagram located on the cover of the electric control box.

3. Clamp down the cable with the cable clamp. The cable must not be loose or pull on the u-lugs.

4. Reattach the electric box cover.


How do I use the optional condensate overflow switch and alarm output on the MRCOOL VERSA PRO MVP-60-HP-230-00?

Condensate Overflow Switch:

The unit will accommodate a remote condensate overflow switch. To enable, remove jumper J1 and connect the installer-provided condensate overflow device to CN5. When an overflow condition is present, the device should open the connection, signaling the unit to turn off the system.

Alarm Output:

An alarm output (CN33) can be utilized if actions are required when a fault is present. This is a passive outlet port, so you will need to input a voltage signal. The relay is normally open for normal operation, and closed when a fault condition is active.


What is the control logic for the indoor and outdoor unit connectors of the MRCOOL VERSA PRO MVP-60-HP-230-00?

Indoor Unit Connector

Connector Purpose
R 24V Power Connection
C Common
G Fan Control
Y1 Low Cooling
Y/Y2 High Cooling
B Heating Reversing Valve
W Heating Control
W1 Stage 1 Electric Heating
W2 Stage 2 Electric Heating
E/AUX Emergency Heating
DH/DS/BK Dehumidification/Zoning Control
L System Fault Signal

Outdoor Unit Connector

Connector Purpose
R 24V Power Connection
C Common
Y1 Low Cooling
Y2 High Cooling
B Heating Reversing Valve
W Heating Control
D Defrost Control
L System Fault Signal

How do I interpret the LED Display and use the KEY1 button on the wired controller for the MRCOOL VERSA PRO MVP-60-HP-230-00?

LED Display:

The control displays unit status as well as any active fault codes on the LED display. If the unit is functioning normally, the LED will display the current temperature setpoint. When a fault code is active, the display will quickly flash the active fault code. Refer to the fault code table located in the troubleshooting section of the manual for detailed fault code information.

KEY1 Instructions (For Wired Controller Only):

Press KEY1 to enter the forced automatic mode. Press KEY1 again to enter the forced cooling mode (LED Display FC). Press KEY1 again to shut down.

Keep pressing KEY1 under forced cooling mode (LED Display FC) for five seconds to enter forced defrost mode.


What are the Indoor Unit Dial Code settings for the MRCOOL VERSA PRO MVP-60-HP-230-00?

No. Dial Code Control Scenario Function ON OFF Note
1 SW1-2 1, 2, 3 Anti-cold blow protection option NO [Default] YES
2 SW1-3 1, 2, 3 Single cooling/heating and cooling options Cooling [Default] Cooling & Heating
3 SW2-1 1 Compressor Running (demand working with heat pump+electric heat) Compressor slower speed [Default] Faster Compressor
4 SW2-1 2 Temperature differential to activate first stage auxiliary heat (the GAP of T1 and Ts), Wire controller demand with heat pump+electric heat working together 2°F (1°C) [Default] 4°F (2°C) Only affects compressor and W1
5 SW2-2 2 Electric heat on delay YES [Default] NO
6 SW2-3 2 Electric auxiliary heating delay to start time 30 minutes [Default] 15 minutes Based on SW2-2 is ON.
7 SW2-4 1 Compressor The operation of the heat pump is limited by the outdoor temperature, and the operation of auxiliary heat is not limited. [Default] The operation of heat pump is limited by the outdoor temperature, and the operation of auxiliary heat is not limited. SW2-4 and S3 need to be working together.
8 SW2-4 2 Compressor/Auxiliary heat outdoor ambient lockout The operation of heat pump is limited by the outdoor temperature, and the operation of auxiliary heat is not limited. [Default] Only one heat pump or auxiliary heat can be operated. SW2-4 and S3 need to be working together.
9 Rotary Switch S3 1, 2 Set outdoor temperature limitation (for auxiliary heating or compressor) Table A
10 SW3-1 1 Maximum continuous runtime allowed before system automatically stages up capacity to satisfy set point. 30 minutes [Default] 90 minutes
11 SW3-2 1 Cooling and heating Y/Y2 temperature differential adjustment Compressor slower speed [Default] Faster compressor Only affects compressor
12 SW3-3 1 Compressor running (demand working with heat pump+electric heat) Compressor slower speed [Default] Faster compressor Only affects compressor and W2
13 SW3-3 2 Temperature differential to activate second stage auxiliary heating (the GAP of T1 and Ts). 4°F (2°C) [Default] 6°F (3°C)
14 SW3-4 1, 3 Fan speed of cooling mode when 24V Thermostat is applied for Turbo High
15 SW4 1, 2, 3 Electric heat nominal CFM adjustment Available settings are 000/001/010/011. See table for corresponding CFM adjustment.
16 S4-1 1, 3 Default ON [Default] For single stage supplemental heat, W1 and W2 are connected For dual stage supplemental heat, W1 and W2 are controlled independently.
17 S4-2 1, 3 DH function selection [Default] Dehumidification control not available Dehumidification feature is enabled through the thermostat

What are the Air Volume (CFM) settings for the MRCOOL VERSA PRO MVP-60-HP-230-00?

The constant airflow volume motor is applied. Therefore, the airflow volume is constant at all External Static Pressure (ESP) within the stated range of 0 – 0.80 in. w.g.

Fan Speed Electric heater kit 24V thermostat Wired controller Airflow volume (CFM)
DIP Switch 24V terminal engaged Mode
Cooling Turbo SW3-4=ON Y2/Y Cool 1806
Cooling High SW3-4=OFF Y2/Y Cool 1582
Cooling Medium Y1 Cool 1359
Cooling Low Cool 1135
Heat Pump Turbo Heat 1659
Heat Pump High B+Y2/Y, W Heat 1582
Heat Pump Medium Y1 Heat 1247
Heat Pump Low Heat 976
Electric heater kit 0(Default) 25KW SW4-1=OFF, SW4-2=OFF, SW4-3=OFF W1, W2, AUX Heat + AUX, AUX 2171
Electric heater kit 1 15KW, 20KW SW4-1=OFF, SW4-2=OFF, SW4-3=ON W1, W2, AUX Heat + AUX, AUX 2029
Electric heater kit 2 10KW, 15KW SW4-1=OFF, SW4-2=ON, SW4-3=OFF W1, W2, AUX Heat + AUX, AUX 1894
Electric heater kit 3 10KW SW4-1=OFF, SW4-2=ON, SW4-3=ON W1, W2, AUX Heat + AUX, AUX 1753

What are the power and line gauge specifications for the MRCOOL VERSA PRO MVP-60-HP-230-00?

Line Diameter Sizing per NFPA 70 (2020), Table 310.5 (B) (16) Based on type NM-B Romex wire. Other sizing options are possible. Consult NFPA 70 or a Licensed Electrician for alternate sizing.

60K
POWER (outdoor) PHASE
FREQUENCY AND VOLT
1 Phase
208/230V, 60Hz
INPUT CIRCUIT FUSE OUTDOOR UNIT(A)
MCA
MOCP
Std 34 / NA
Hyper HT 60 / NA
LINES GAUGE OUTDOOR UNIT POWER LINE LINE QUANTITY 2+Ground
LINE DIAMETER(AWG) STD 8
HH NA
OUTDOOR-INDOOR SIGNAL LINE LINE QUANTITY 2
LINE DIAMETER(AWG) 20
THERMOSTAT SIGNAL LINE LINE QUANTITY
LINE DIAMETER(AWG) 18

How do I perform an air evacuation on the MRCOOL VERSA PRO MVP-60-HP-230-00?

Air and foreign matter in the refrigerant circuit can cause abnormal rises in pressure, which can damage the unit. Use a vacuum pump and manifold gauge to evacuate the refrigerant circuit. Evacuation should be performed upon initial installation and when the unit is relocated.

Before Performing Evacuation:

✓ Check to ensure the connective pipes between the indoor and outdoor units are connected properly.

✓ Check to make sure all wiring is connected properly.

Evacuation Instructions:

1. Connect the charge hose of the manifold gauge to the service port on the outdoor unit’s low pressure valve.

2. Connect another charge hose from the manifold gauge to the vacuum pump.

3. Open the low pressure side of the manifold gauge. Keep the high pressure side closed.

4. Turn on the vacuum pump to evacuate the system.

5. Run the vacuum for at least 15 minutes, or until the compound meter reads -750 Microns (-105Pa).

6. Close the low pressure side of the manifold gauge, and turn off the vacuum pump.

7. Wait for 5 minutes, then check that there has been no change in system pressure.

8. If there is a change in system pressure, refer to the Gas Leak Check section for information on how to check for leaks. If there is no change in system pressure, unscrew the cap from the packed valve (high pressure valve).

9. Insert a hexagonal wrench into the packed valve (high pressure valve) and open the valve by turning the wrench in a 1/4 counter-clockwise turn. Listen for gas to exit the system, then close the valve after 5 seconds.

10. Watch the pressure gauge for one minute to make sure that there is no change in pressure. The pressure gauge should read slightly higher than atmospheric pressure.

11. Remove the charge hose from the service port.

12. Using a hexagonal wrench, fully open both the high pressure and low pressure valves.

13. Tighten valve caps on all three valves (service port, high pressure, and low pressure) by hand. Tighten it further using a torque wrench if needed.


How do I calculate and add extra refrigerant to the MRCOOL VERSA PRO MVP-60-HP-230-00?

DO NOT mix refrigerant types. Some systems require additional charging depending on pipe lengths. The standard pipe length varies according to local regulations. For example, in North America, the standard pipe length is 7.5m (25′). The refrigerant should be charged from the service port on the outdoor unit’s low pressure valve. The additional refrigerant to be charged can be calculated using the following formula:

Liquid Side Diameter
φ6.35(1/4″) φ9.52(3/8″) φ12.7(1/2″)
R410A: (metering device in the indoor unit) (Total pipe length – standard pipe length) x30g(0.32oz)/m(ft) (Total pipe length – standard pipe length) x65g(0.69oz)/m(ft) (Total pipe length – standard pipe length) x115g(1.23oz)/m(ft)
R410A: (metering device in the outdoor unit) (Total pipe length – standard pipe length) x15g(0.16oz)/m(ft) (Total pipe length – standard pipe length) x30g(0.32oz)/m(ft) (Total pipe length – standard pipe length) x65g(0.69oz)/m(ft)

What checks should I perform before the initial test run of the MRCOOL VERSA PRO MVP-60-HP-230-00?

A test run must be performed after the entire system has been completely installed. Confirm the following points before performing the test:

a) Indoor and outdoor units are properly installed.

b) Piping and wiring are properly connected.

c) No obstacles near the inlet and outlet of the unit that might cause poor performance or product malfunction.

d) Refrigeration system does not leak.

e) Drainage system is unimpeded and draining to a safe location.

f) Insulation of piping and duct is properly installed.

g) Grounding wires are properly connected.

h) Length of the piping and additional refrigerant capacity have been recorded.

i) Power voltage is the correct voltage for the system.


How do I perform a test run on the MRCOOL VERSA PRO MVP-60-HP-230-00?

Failure to perform the test run may result in unit damage, property damage, or personal injury.

1. Open both the liquid and gas service valves.

2. Turn on the main power switch and allow the unit to warm up.

3. Set the unit to COOL mode.

4. For the Indoor Unit

a. Double check to see if the room temperature is being registered correctly.

b. Ensure the manual buttons on the indoor unit work properly.

c. Check to see that the drainage system is unimpeded and draining smoothly.

d. Ensure there is no vibration or abnormal noise during operation.

5. For the Outdoor Unit

a. Check for any leaks from the refrigeration system.

b. Make sure there is no vibration or abnormal noise during operation.

c. Ensure the wind, noise, and water generated by the unit do not disturb individuals nearby or pose a safety hazard.

6. Drainage Test

a. Ensure the drainpipe flows smoothly. New buildings should perform this test before finishing the ceiling.

b. Turn on the main power switch and run the unit in COOL mode.

c. Check to see that the water is discharged. It may take up to one minute before the unit begins to drain depending on the drainpipe.

d. Make sure that there are no leaks in any of the piping.

e. Stop the unit. Turn off the main power switch.


What does the 24V Signal Chart indicate for the various operating modes of the MRCOOL VERSA PRO MVP-60-HP-230-00?

The 24V signal chart shows which terminals receive a 24V signal for different operating modes. The AUU (Air Handler Unit) will turn off if the 24V input does not meet the table requirements. Note: 1 = 24V signal; 0 = No 24V signal; * = 1 or 0.

Mode Priority 24V input terminal Fan speed Display
G Y1 Y/Y2 B W W1 W2 E/AUX DH/DS/BK
OFF / 0 0 0 0 0 0 0 0 * OFF 0
FAN 7 1 0 0 * 0 0 0 0 * Low 1
Cooling stage 1 6 * 1 0 0 0 0 0 0 1 Mid 2
Cooling stage 2 * * 1 0 0 0 0 0 1 High 3
Dehumidification * 1 0 0 0 0 0 0 0 Low 4
Dehumidification * * 1 0 0 0 0 0 0 Low 5
Heat pump stage 1 5 * 1 0 1 0 0 0 0 1 Mid 6
Heat pump stage 2 * * 1 1 0 0 0 0 1 High 7
Heat pump stage 2 * * * * 1 0 0 0 1 High
Electric heater kit 1 3 * 0 0 * 0 1 0 0 * Turbo 8
Electric heater kit 2 * 0 0 * 0 0 1 0 * Turbo 9
Electric heater kit 1 and kit 2 * 0 0 * 0 1 1 0 * Turbo
Heat pump stage 1 + Electric heater kit 1 4 * 1 0 1 0 1 0 0 1 Turbo 10
Heat pump stage 1 + Electric heater kit 2 * 1 0 1 0 0 1 0 1 Turbo
Heat pump stage 2 + Electric heater kit 1 * * 1 1 0 1 0 0 1 Turbo
Heat pump stage 2 + Electric heater kit 1 * * * * 1 1 0 0 1 Turbo
Heat pump stage 2 + Electric heater kit 2 * * 1 1 0 0 1 0 1 Turbo 11
Heat pump stage 2 + Electric heater kit 2 * * * * 1 0 1 0 1 Turbo
Heat pump stage 1 + Electric heater kit 1 and kit 2 * 1 0 1 0 1 1 0 1 Turbo
Heat pump stage 2 + Electric heater kit 1 and kit 2 * * 1 1 0 1 1 0 1 Turbo 11
Heat pump stage 2 + Electric heater kit 1 and kit 2 * * * * 1 1 1 0 1 Turbo
Emergency heat 1 * * * * * * * 1 * Turbo 12
Heating zone control 2 * 1 0 1 0 * * 0 0 Low 13
Heating zone control * * 1 1 0 * * 0 0 Low
Heating zone control * * * * 1 * * 0 0 Low
Heating zone control * 0 0 * 0 1 0 0 0 Low
Heating zone control * 0 0 * 0 0 1 0 0 Low
Heating zone control * 0 0 * 0 1 1 0 0 Low

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD MRCOOL VERSA PRO MVP-60-HP-230-00 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.