MR GASKET 8000MRG (01) Image

FREE ENGLISH MR GASKET 8000MRG (01) PDF DOCUMENT.
FREE ENGLISH MR GASKET 8000MRG (01) PDF USER GUIDE.
FREE ENGLISH MR GASKET 8000MRG (01) PDF USER MANUAL.
FREE ENGLISH MR GASKET 8000MRG (01) PDF OWNER GUIDE.
FREE ENGLISH MR GASKET 8000MRG (01) PDF OWNER MANUAL.
FREE ENGLISH MR GASKET 8000MRG (01) PDF REFERENCE GUIDE.
FREE ENGLISH MR GASKET 8000MRG (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH MR GASKET 8000MRG (01) PDF REFERENCE MANUAL.
FREE ENGLISH MR GASKET 8000MRG (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH MR GASKET 8000MRG (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD MR GASKET 8000MRG (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

How do I place the batteries in the MR GASKET 8000MRG?

To place the batteries in your MR GASKET 8000MRG, follow these steps:

How to open the battery cover: Place your thumb in the grooves as shown in the picture, push and slide the cover off in the direction of the arrow.

Direction of Batteries: Insert 4 AA batteries according to the + and – signs indicated.

It is important to:

*Replace all 4 batteries at the same time.

*Use the same brand/type of batteries.


Can I operate the MR GASKET 8000MRG if all four AA batteries are not available?

It is recommended to use all 4 AA batteries when you are able, but it is possible to operate the MR GASKET 8000MRG with 2 AA batteries during emergencies.

*With 4 batteries, the pump can pump out approximately 50 x 5 gallon fuel cans.

*With 2 batteries, the pump can pump out approximately 25 x 5 gallon fuel cans.


When should I replace the batteries in the MR GASKET 8000MRG?

You should replace the batteries in your MR GASKET 8000MRG when:

• The motor does not operate, even after pressing the ON switch.

• The transfer rate becomes slower than in normal operation.

Batteries can begin to discharge if they are stored for a long period of time. Always check the expiration dates of the batteries.


What are the steps for using the MR GASKET 8000MRG fuel transfer pump?

1. Make sure the utility jug adapter is fastened tightly to your supply tank.

2. Insert the intake hose through the adapter and fasten the pump’s universal threaded adapter tightly.
Caution: Do not lift up or push down the pump while it is attached to the fuel tank.

Note: Use the universal threaded adapter without the utility jug adapter to fasten the pump to most North American 5 gallon and smaller fuel cans.

3. Attach the discharge hose to your receiving tank using the clip. Make sure the discharge nozzle is in a vertical position.
Caution: Make sure that the supplying tank and receiving tank are on the same level when the pump is operating. For tanks which are not fixed with the clip, make sure the discharge nozzle is vertical to the liquid level.

4. Start the flow of fuel by pressing the ON button. The pump automatically stops when the fuel reaches the stop line.
Caution: Automatically stops when the fuel reaches the stop line.

5. After automatically stopping, bring the discharge hose up above the tank to drain the excess fuel or liquid back into the supply tank.

6. Put the discharge nozzle in the discharge nozzle compartment and lock it into place with the clip.
Caution: Place the discharge nozzle into the discharge nozzle compartment properly after fueling. In the event the fuel tank falls over, and the discharge hose is not in its storage hole, liquid can leak out.


How should I store the MR GASKET 8000MRG?

When the MR GASKET 8000MRG pump is not being used for long periods of time, take the pump out of the tank, make sure no remaining fuel is in the hose, and wipe it down with a cloth before storing it.

Make sure to take the batteries out before storing the pump.

Do not store the pump in an enclosed airtight container.


What are the product specifications for the MR GASKET 8000MRG?

Model 8000MRG Major materials: Polypropylene, Polyethylene, Polyacetal
Battery: AAx4 (not included) Operating temperature: Approx. 5°C to 40°C (41°F ~ 104°F)
Flux: About 2.5 GPM (9.5 LPM)
*Flow rate is based on pumping gasoline with DC 3V 3A without any elevation
Compatible liquids: Gasoline, Kerosene, Diesel, Non-potable water
Electrical Supply: 3VDC, 3A Pollution degree: 2
Altitude: 2000 m Installation category: I
Duty Cycle: 5 minutes run 10 minutes rest

What actions should be avoided when using the MR GASKET 8000MRG?

Do not transfer fuel while vehicle or the vehicle’s heater is ON (may cause a fire).

Do not leave the pump unattended (may cause oversupply of oil, a fire or any accident).

Do not alter or disassemble the pump (may cause failure of the product or an accident).

Do not place the pump in a wet area (may cause failure of the product or an accident).

Do not use deteriorated or aged fuels (these may cause our product to fail).

Do not use for drinkable liquid, thinner, solvent, acetone, benzene, cresol, ethanol, methanol, phenol, concentrated caustic soda liquid, nitric acid, hydrochloric acid, sulfuric acid, etc.

Do not shock the pump (may cause a failure or damage of the product).

Do not put the product in a vehicle with all windows closed, direct sunlight area, or next to any heating appliances (may cause an accident or transform the product).

Do not run the pump ‘dry’ or let the pump idle without transferring (may cause failure of product).

Do not close the hole of sensor inlet. Do not supply the oil into transparent vessel under direct sunlight (may not stop automatically and overflow of liquid).

Do not allow children to operate the product without adult supervision.

Do not use the product on carpet, wood floor or combustible area (may cause a fire). Be careful not to damage the floor surface and/or carpet by fuel leakage.


What are the mandatory safety instructions for the MR GASKET 8000MRG?

Make sure to use the pump on an even surface (If the tank falls down during the liquid supply, liquid will leak and may cause a fire or an accident).

Make sure the pump is tightly secured to the tank before turning the pump on.

Make sure the sensor on the discharge nozzle is vertical (may not stop automatically, could cause fuel to overflow).

Make sure to press the OFF switch after each use of the pump (may cause the continual consumption of battery and leak of liquid which will cause malfunction of the product).

Make sure to remove any left-over fuel in the pump after each use (may cause failure of the pump if fuel remains around the sensor).

Make sure to detach the tank from the pump when moving and when storing the tank (may cause leak of fuel if moved while the tank is attached).


What are the main operational warnings for the MR GASKET 8000MRG?

WARNING: IMPROPER USE CAN CAUSE A DEATH OR SERIOUS INJURY.

WARNING: IF THE EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THE MANUFACTURER, A FIRE HAZARD MAY BE CAUSED.


How do I troubleshoot my MR GASKET 8000MRG?

SYMPTOM CAUSE TREATMENT
Pump does not operate even after pressing ON Batteries may be incorrectly placed Ensure the batteries are placed in the pump correctly
Batteries are depleted Replace the batteries
Impeller is stuck Turn the impeller manually
Battery terminals are rusted Clean the rust from battery terminals
Pump’s performance is low Batteries are depleted Replace the batteries
Elevation of receiving tank is higher than supplying tank Make sure that the receiving tank is not elevated above the supply tank
Pump starts after pressing ON button but then stops unexpectedly Filter of receiving tank may be blocked with foreign material Clean foreign material from the filter
Pump immediately stops after pressing the ON button Batteries are depleted Replace the batteries
Motor stops before receptacle tank is full Batteries are depleted Replace the batteries
Sensor is too low and is touching the liquid Adjust the discharge nozzle up so that the sensor is closer to the top of the supply tank