PDF Content Summary: INSTALLATION INSTRUCTIONS 550-LED Pendant PD-55024/55036/55048 CAUTION: To prevent electrical shock, ensure electricity has been turned off at the circuit breaker before beginning. • Read all instructions before installing. • System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations. • When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only. • Retain installation instructions for future maintenance reference. WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern Forms could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are damaged or missing. MAINTENANCE NOTE: Coastal conditions may cause mineral and residue build-up on the fixture. We recommend that customers in coastal areas clean all external surfaces of the fixture once every two weeks with a wet cloth. MISE EN GARDE: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer. • Lisez toutes les instructions avant l’installation. • Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux règlements locaux. • Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base. ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement avec les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus pour ce produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées. NOTE D’ENTRETIEN: Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec un chiffon humide. HARDWARE A B C D

Mounting screw Wood screw Plastic anchor

modernforms.com modernforms.com Phone (800) 526.2588 Phone (800) 526.2588 Fax (800) 526.2585 Fax (800) 526.2585 Headquarters/Eastern Distribution Center Headquarters/Eastern Distribution Center 44 Harbor Park Drive 44 Harbor Park Drive Port Washington, NY 11050 Port Washington, NY 11050 Central Distribution Center Central Distribution Center 1600 Distribution Ct 1600 Distribution Ct Lithia Springs, GA 30122 Lithia Springs, GA 30122 Western Distribution Center Western Distribution Center 1750 Archibald Avenue 1750 Archibald Avenue Ontario, CA 91760 Ontario, CA 91760

1 Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

INSTALLATION INSTRUCTIONS 550-LED Pendant PD-55024/55036/55048 PREPARATION Fig. 1 Junction Box

Plastic anchor Wire connector

D 1. Shut off the power at the circuit breaker and remove existing fixture, A including the crossbar. 2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation. Back plate Safety cood PS:PD-55048 MOUNTING THE FIXTURE (Fig. 1) Junction box screw Wood screw C Mounting screw B 3. Remove the mounting screw (B) from the fixture. 4. Drill holes in the wall aligned with the key holes located in the back Ground wire Driver

plate, insert the plastic anchor (D) 5. Secure back plate to the junction box using standard junction box screws that comes with the junction box. Fasten it to the wall using wood screw (C) onto the plastic anchor. Note: the side of the mounting plate marked “GND” must face out. 6. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired. a. Retract these wires close to a desirable length to within the canopy before securing the fixture in place. Note: retracting or extending excessive cable length through the cable gripper is not recommended. b. Warning: Shortening these cables without professional helps or electronic background is not advisable. Any modifications to the fixture may result in voiding the warranty of the product. CONNECTING THE WIRES (Fig. 2) Cable-gripper Push up Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired. Fixture

7. Connect the driver input/output wires with junction box wires as shown in Fig.2, making sure that all wire connectors (A) (C)are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the mounting plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box. 8. This fixture features electronic low voltage (ELV or TRAIC) or 0-10V dimming capabilities. See notes below for specific dimming wiring information. 9. Secure the fixture to the back plate using the mounting screw (B). NOTE: DIMMING WIRING INFORMATION (Fig. 3) 10. This fixture features electronic low voltage (ELV or TRAIC) or 0-10V dimming capabilities. See notes below for specific dimming wires information. 11. To utilize ELV or TRAIC dimming: use wires black (hot), white (neutral) and bare copper ground wire (ground). 12. To utilize 0-10V dimming: use wir e purple (dim+), gray (dim-), black (hot), white (neutral) and bare copper ground wire (ground). NOTE: Make sure to connect 0-10V prior to power-up the fixture in order to allow the 0-10V dimming to function properly. Fig. 2 Wiring Fig. 3 Back Plate Dimensions

Fixture Wires Black or Smooth Fixture Wires White or Ribbed Fixture Wires Bare wire (Ground) modernforms.com modernforms.com House Wires Black (Hot) House Wires White (Neutral) House Wires Green or Bare Copper (Ground) Headquarters/Eastern Distribution Center Headquarters/Eastern Distribution Center Central Distribution Center Central Distribution Center Φ 6 3/4” 1 3/8” 1 3/4” Western Distribution Center Western Distribution Center Phone (800) 526.2588 Phone (800) 526.2588 Fax (800) 526.2585 Fax (800) 526.2585 44 Harbor Park Drive 44 Harbor Park Drive Port Washington, NY 11050 Port Washington, NY 11050 1600 Distribution Ct 1600 Distribution Ct Lithia Springs, GA 30122 Lithia Springs, GA 30122 1750 Archibald Avenue 1750 Archibald Avenue Ontario, CA 91760 Ontario, CA 91760

2 Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017