What are the important safety warnings for the MEGGER MPCC230?

WARNING: Failure to follow these safety instructions could result in fire, electric shock, or other injury or damage to the MPCC230, or other property. Read all safety information and operating instructions before using the MPCC230.

This product is manufactured following IEC/EN61010-1, guidelines for safety installation testers. Follow this user manual to avoid damaging the instrument:

Local Health and Safety Legislation require users of this equipment and their employers to conduct valid risk assessments of all electrical work to identify potential sources of danger and issue safe working procedures.

Understand and follow the operating instructions carefully.

No user serviceable parts inside.

Do not use in high humidity or wet environment.

Do not use in an explosive atmosphere.

The maximum input voltage is 250 V. Connecting to higher voltages will cause permanent damage to the instrument and may give rise to the potential of electric shock.

Extreme care must be taken when measuring above 50 V.

The circuit checker must not be used if any part of it is damaged.

Check for correct operation by testing a known voltage before and after use. Do not use it if misleading results are obtained.

Warnings and precautions must be read and understood before the circuit checker is used. They must be observed during the operation of this circuit checker.

Personal protective equipment should be used if there are ACCESSIBLE HAZARDOUS LIVE PARTS in the installation where measurement is to be carried out.

Do not use on or around uninsulated hazardous live conductors where a potential to cause electric shock, electrical burns or arc flash exists.


What do the symbols on the MEGGER MPCC230 instrument mean?

Icon Description
High Voltage Warning Symbol Warning: High Voltage, risk of electric shock
Caution Symbol Caution: Refer to user guide.
Double Insulation Symbol Double/reinforced insulation throughout
UK CA UK conformity. This equipment complies with current UK legislation
CE EU conformity. Equipment complies with current EU directives.
Australian Conformity Symbol Conforms to relevant Australian Safety and EMC standards
Prohibited above 250V Symbol Prohibited for use on electrical systems above 250 V
Do Not Dispose Symbol Do not dispose of in the normal waste stream.

What are the installation category definitions for the MEGGER MPCC230?

CAT IV – Measurement category IV: Equipment connected between the origin of the low-voltage mains supply and the distribution panel.

CAT III – Measurement category III: Equipment connected between the distribution panel and the electrical outlets.

CAT II – Measurement category II: Equipment connected between the electrical outlets and the user’s equipment.

Measurement equipment may be safely connected to circuits at the marked rating or lower.

The connection rating is that of the lowest rated component in the measurement circuit.

This instrument is intended for origin of installation use and is protected by double insulation per EN 61010- 1:2010 +A1:2019 Safety requirements for electrical equipment for measurement, control, and laboratory use to Measurement connection: CAT II 250 V; Pollution Degree 2. The instrument also meets EN 62196-2:2022, Plugs, socket-outlets, vehicle connectors and vehicle inlets.


What are the main components and buttons of the MEGGER MPCC230?

Item Description Display
1 TEST button Starts a test or selects memory download bar code
2 Function button to select the measurement mode. Socket Test / VOLT – RCD – LOOP – Harmonics / Memory.
3 Sub-function navigation Cycle through displayed features or memory values
4 Display TFT 1,77”
5 Anti-scratch glass
6 UK plug
7 EU plug

How do I operate the MEGGER MPCC230?

1. Connect the MPCC230 to a socket.

2. Press FUNC to cycle through Measurement Modes. The sequence is: Volt -> Loop -> RCD -> HAR -> MEM.

3. Press F1 or F2 for Sub-functions.

4. Press and hold the Test button to begin a test.

5. Read Reports on your smart device by downloading the MPCC Link App.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD MEGGER MPCC230 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.