Free English MEDTRONIC RIST 079 (01) PDF Document. Free English MEDTRONIC RIST 079 (01) PDF User Guide. Free English MEDTRONIC RIST 079 (01) PDF User Manual. Free English MEDTRONIC RIST 079 (01) PDF Owner Guide. Free English MEDTRONIC RIST 079 (01) PDF Owner Manual. Free English MEDTRONIC RIST 079 (01) PDF Reference Guide. Free English MEDTRONIC RIST 079 (01) PDF Instruction Guide. Free English MEDTRONIC RIST 079 (01) PDF Reference Manual. Free English MEDTRONIC RIST 079 (01) PDF Instruction Manual. Free English MEDTRONIC RIST 079 (01) PDF Operating Instructions.
CLICK HERE TO DOWNLOAD MEDTRONIC RIST 079 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What is the MEDTRONIC RIST 079 Radial Access Guide Catheter?
The MEDTRONIC RIST 079 Radial Access Guide Catheter is a single lumen, flexible, variable stiffness long sheath. It has a radiopaque marker band on its distal end and a Luer hub at the proximal end. The shaft features a 25 cm lubricious coating at the distal end to reduce friction during use. Each package contains one MEDTRONIC RIST 079 Radial Access Guide Catheter and one Dilator.
What is the intended purpose of the MEDTRONIC RIST 079?
The MEDTRONIC RIST 079 Radial Access Guide Catheter is indicated for the introduction of interventional devices into the peripheral, coronary, and neuro vasculature.
What are the device compatibility specifications for the MEDTRONIC RIST 079?
The inner lumen of the MEDTRONIC RIST 079 Radial Access Guide Catheter is compatible with 6F (0.078 inch OD or 1.99 mm OD) or smaller catheters.
Are there any contraindications for the MEDTRONIC RIST 079?
Yes, the MEDTRONIC RIST 079 Radial Access Guide Catheter is contraindicated for use with liquid embolic agents, such as n-butyl cyanoacrylate, ethylene vinyl alcohol, and dimethyl sulfoxide (DMSO) based materials.
How should the MEDTRONIC RIST 079 be prepared for use?
1. Select the appropriately sized device based on procedure type and patient anatomy.
2. Grasp the hub and gently remove the MEDTRONIC RIST 079 Radial Access Guide Catheter from its protective tubing.
3. Inspect the product for kinks or other damage. If any damage is observed, replace with a new device.
4. Flush the inner lumen with saline and connect a Hemostasis valve to the hub of the MEDTRONIC RIST 079 Radial Access Guide Catheter.
IF USING DILATOR:
Flush and wet the dilator with saline.
Insert the dilator completely into The MEDTRONIC RIST 079 Radial Access Guide Catheter.
What are the directions for using the MEDTRONIC RIST 079?
1. Gain primary radial artery access using standard technique.
IF NOT USING A SHORT SHEATH:
Advance the MEDTRONIC RIST 079 Radial Access Guide Catheter/dilator assembly over the guide wire (0.037 inches or 0.94 mm or smaller) and advance products into vasculature. Remove the dilator.
IF USING A SHORT SHEATH:
Advance the MEDTRONIC RIST 079 Radial Access Guide Catheter over the guide wire into the appropriately sized short sheath. It is recommended to use a shaped catheter/dilator with the MEDTRONIC RIST 079 Radial Access Guide Catheter to aid insertion into a short sheath.
Insert appropriately sized catheters as needed and advance products to the intended vascular site under fluoroscopic guidance.
2. When use of the MEDTRONIC RIST 079 Radial Access Guide Catheter is complete, remove the product using standard technique.
3. After use, the device may be a potential biohazard. Handle and dispose of product in accordance with facility protocol and applicable local, state, and federal laws and regulations.
What warnings are associated with the MEDTRONIC RIST 079?
Contents supplied sterile using an ethylene oxide (EO) process. Do not use if sterile barrier is damaged.
Do not use if labeling is incomplete or illegible.
For single use only. Do not reuse, reprocess or resterilize. Reuse, reprocessing or resterilization may compromise the structural integrity of the device and/or lead to device failure which, in turn, may result in patient injury, illness or death. Reuse, reprocessing or resterilization may also create a risk of contamination of the device and/or cause patient infection or cross-infection, including, but not limited to, the transmission of infectious disease(s) from one patient to another. Contamination of the device may lead to injury, illness or death of the patient.
When the Guide Catheter is introduced to the vascular system, it should be manipulated while under high-quality fluoroscopic observation. Do not advance or retract the Guide Catheter if resistance is met during manipulation; determine the cause of the resistance before proceeding.
Torquing or moving the device against resistance may result in damage to the vessel or device.
This device is coated with a hydrophilic coating at the distal end of the device for a length of 25cm. Please refer to the preparation and directions sections for further information on how to prepare and use this device to ensure it performs as intended. Failure to abide by the warnings in this labeling may result in damage to the device coating, which may necessitate intervention or result in serious adverse events.
After use, dispose of product and packaging in accordance with hospital, administrative and/or local government policy.
What precautions should be taken when using the MEDTRONIC RIST 079?
1. The MEDTRONIC RIST 079 Radial Access Guide Catheter must only be used by physicians trained in intravascular intervention.
2. Use the device prior to the “Use By” date specified on the package.
3. Maintain a constant infusion of appropriate flush solution.
4. If flow through the device becomes restricted, do not attempt to clear the lumen by infusion. Remove and replace the device.
5. Examine the device to verify functionality and to ensure that its size and shape are suitable for the specific procedure for which it is to be used.
6. The MEDTRONIC RIST 079 Radial Access Guide Catheter should be used only by physicians trained in percutaneous procedures and/or interventional techniques.
7. Prior to beginning radial artery access, perform an assessment of the collateral circulation of the hand to ensure that radial access is appropriate for the patient.
8. Limit the exposure to X-ray radiation doses to patients and physicians by using sufficient shielding, reducing fluoroscopy times, and modifying X-ray technical factors when possible.
9. Avoid wiping the device with dry gauze as this may damage the device coating.
10. Avoid excessive wiping of the coated device.
11. Avoid using alcohol, antiseptic solutions, or other solvents to pre-treat the device because this may cause unpredictable changes in the coating which could affect the device safety and performance.
12. Use an appropriate hemostasis valve during the procedure.
How should the MEDTRONIC RIST 079 be handled and stored?
This device should be stored in a dry place, away from sunlight.
What are the potential complications associated with the MEDTRONIC RIST 079?
Potential complications include:
Air Embolism
Allergic Reaction
Death
Embolism
False Aneurysm Formation
Fistula
Hemorrhage
Hypersensitivity
Hypotension
Infection
Inflammation
Intracranial hemorrhage
Ischemia
Material Left in Patient
Neurological deficit/ dysfunction
Occlusion
Organ failure
Pain And Tenderness
Radial Artery Occlusion
Stenosis
Stroke/Cerebral infarction
Therapeutic response decreased
Thromboembolism
Thrombus/Thrombosis
Vessel Collapse
Vessel Dissection
Vessel Perforation or Rupture
Vessel Spasm/Vasoconstriction
Vision symptoms
What is the meaning of the symbols on the MEDTRONIC RIST 079 packaging?
| STERILE EO | Sterilized using ethylene oxide |
| Do not re-use | Do not re-use |
| Rx ONLY | Caution: Federal (USA) law restricts this device to sale by or on the order of a physician |
| Do not resterilize | Do not resterilize |
| i | Consult instructions for use at this website |
| ! | Caution |
| Do not use if package is damaged | Do not use if package is damaged |
| Ж | Non-pyrogenic |
| * | Keep away from sunlight |
| Keep dry | Keep dry |
| REF | Catalogue number |
| Manufacturer | Manufacturer |
| Σ | Use-by date |
| LOT | Batch code |
| Date of manufacture | Date of manufacture |
| CONTENTS | Contents of Package |
| BIO | Contains biological material of animal origin |
| Radial Access Guide Catheter | Radial Access Guide Catheter |
| Dilator | Dilator |