LIBERTY PUMPS AE21L-3 (01) PDF SUMMARY:

What should I do if I have questions about servicing the control panel?

Call the factory at 1-800-543-2550.


Who should install and service this control panel?

A licensed electrician should install and service this control panel in accordance with the National Electric Code NFPA-70, state, and local electrical codes.


What is the warranty offered by Liberty Pumps?

Liberty Pumps offers a three-year limited warranty. Visit http://www.libertypumps.com for complete terms and conditions.


What should I do with products that are being returned?

Products being returned must be cleaned, sanitized, or decontaminated as necessary prior to shipment. This is to ensure that employees will not be exposed to health hazards in handling the material. All applicable laws and regulations apply.


What does the control panel operate with?

The Single Phase Duplex control panel operates with float switches.


When is the panel inactive?

When all floats are in the open or OFF position, the panel is inactive.


What happens when the liquid level rises and closes the STOP float?

The panel remains inactive until the LEAD float closes.


What happens when the LEAD float closes?

At this point, the LEAD pump will turn ON if the Hand-Off-Auto switch is in the AUTO mode and the power is ON.


How long will the pump remain on?

The pump will remain ON until both the STOP and LEAD floats return to their OFF positions.


What happens if the liquid level rises beyond both the STOP and LEAD floats to reach the LAG float?

The LAG pump will turn ON if the Hand-Off-Auto switch is in the AUTO mode and the power is ON.


How long will both pumps remain on?

Both pumps will remain ON until the STOP, LEAD, and LAG floats return to their OFF positions.


What happens if the liquid level rises to reach the ALARM float?

The alarm will be activated.


What happens when an alarm condition occurs?

The red light and horn will be activated.


How can the horn be silenced?

If the TEST/NORMAL/SILENCE switch is moved to the SILENCE position and released, the horn will be silenced.


What happens when the alarm condition is cleared?

The alarm system is reset.


What do the HOA 3-way switches control?

The HOA 3-way switches control pump functions.


What does the HAND mode do?

In HAND mode, the pump will turn ON.


What does the OFF mode do?

OFF turns the pump OFF.


What does the AUTO mode do?

In AUTO mode, commands from the float switches turn each pump ON and OFF.


What do circuit breakers provide?

Circuit breakers provide pump disconnect and branch circuit protection. Note that circuit breakers are optional.


What do motor contactors do?

Motor contactors control pumps by switching electrical lines.


What functions do the float switches activate?

The float switches activate pump STOP, LEAD pump START, LAG pump START, and high-level ALARM functions.


What should be done before installing floats in the tank?

Ensure all power is turned OFF before installing floats in the tank. Failure to do so could result in serious or fatal shock.


What should be done with each float and cord end?

Label each float and cord end with the provided pairs of STOP, LEAD, LAG, and ALARM stickers.


What should be done if the distance to the control panel exceeds the length of the float switch cords or the pump power cord?

Splicing in a liquid-tight junction box will be required. For outdoor or wet installation, a Liberty Pumps UL Type 4X junction box is recommended.


What should you determine when wiring the control panel?

Determine conduit entrance locations on the control panel.


What should you check when wiring the control panel?

Check local codes and the schematic inside the panel for the number of power circuits required. Be sure the pump power voltage and phase are the same as the pump motor being installed.


What wires should be connected to the proper terminal positions?

Connect the following wires to the proper terminal positions:

  • incoming power
  • pump 1
  • pump 2
  • float switches

See the schematic inside the control panel for details.


What should be verified after installation is complete?

Verify correct operation of the control panel after installation is complete.


What type of conduit must be used to maintain a Type 4X rating of the control panel?

Type 4X conduit must be used to maintain a Type 4X rating of the control panel.


What must be used to prevent moisture or gases from entering the panel?

Conduit sealant must be used to prevent moisture or gases from entering the panel.


What happens if the floats are not properly mounted and connected in the correct order?

If the floats are not properly mounted and connected in the correct order, the pumps will not function properly.


What should you ensure regarding the floats?

Floats require a free range of motion. They must not touch each other or any equipment in the pump chamber.


What is the function of the ON/OFF switch?

The ON/OFF switch controls control/alarm power.


Where are the float terminals located?

Float terminals are located inside the control panel.


What do the float LEDs indicate?

The float LEDs indicate the status of the floats.


What do the pump LEDs indicate?

The pump LEDs indicate pump run status (green) and pump fail status (red).


What is the function of the lead/lag selector switch?

The lead/lag selector switch selects which pump will be the lead pump.


What is the function of the auxiliary alarm terminals?

The auxiliary alarm terminals are used to connect external alarm devices. They can be wired normally open or normally closed.


What do the simulate float buttons do?

The simulate float buttons simulate the activation of the float switches for testing purposes.


What do the pump HOA switches do?

The pump HOA switches allow you to select the operating mode for each pump (Hand, Off, or Auto).


How can I program the float button options?

With power on, HOAs off, floats off or disconnected, press the desired float button rapidly 4 times and hold. The pump LEDs will flash upon successful programming.


What does the “Pump Fail Alarm Stop On” option do?

Activates if a pump causes “LAG” 3 cycles in a row.


What does the “Manual Alarm Reset Lead Off” option do?

Latches high alarm: clear with external test switch.


What does the “Seal Fail Horn Lag Off” option do?

Activates horn upon seal fail.


What does the “Alarm Flasher Alarm Off” option do?

Flashes beacon upon high alarm.


What does a flashing red pump light indicate?

Pump fail.


What does a flashing SF1 or SF2 PROG indicate?

Seal fail.


What does a flashing “BAD FLOAT” LED indicate?

Float fail.


What does a solid alarm float LED indicate?

High alarm.

CLICK HERE TO DOWNLOAD LIBERTY PUMPS AE21L-3 (01) PDF MANUAL