****** Page 1 ****** INs-rnucT10N MANUAL AUTO EJECT WP AUTOMATIC SHORELINE DISCONNECT MODEL MODEL MODEL # : 091-newp-one # : 091-newp.neo # : 091 -eowp-neo File: IM_091-1 Bwp_reve.indd Revised By: SO Date: 09-22-201 5 170 Cherry Avenue West Sayville, NY 11796 kussmaul.com 092 YEAR WARRANTY eKiJSSMAlJL ELECTRONICS ENERGIZED AND READY, WHEN SECONDS COUNT scan using your mobile device for more information Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com

****** Page 2 ****** INTRODUCTION The Auto Eject WP is a power input connector designed to be mounted in the side of a vehicle to permit connecting the shoreline. It comes with a weatherproof cover. The cover is spring loaded to close, preventing water from entering when the shoreline is not connected. A solenoid wired to the vehicle’s starter, is energized when the engine is cranked. This instantaneously drives the plug from the receptacle. This simple, reliable device, eliminates forever the broken cables which result when drivers forget to remove the shoreline before driving away. INSTALLATION INSTRUCTIONS l. MOUNTING THE AUTO EJECT WP 1. Locate a convenient place on the vehicle to mount the Auto Eject WP. A minimum clearance of 4″ behind the mounting panel is required as well as 3 3/4″ below the center line to clear the ejection mechanism. 2. Place the template in position and center punch in 7 places, see Figure 1 Hole Template. 3. Drill 2 holes, 1/2″ diameter. IMPORTANT THESE HOLES MUST BE DRILLED FIRST. 4. Drill 4 mounting holes, 3/16″ diameter and one, 2 1/4″ clearance hole for the Auto Eject WP. II. FIGURE 1, HOLE TEMPLATE FOR THE AUTO EJECT WP 1. Note: When printing this page, use the print setting “Actual Size” otherwise may not print to scale 3/16″ Dia. Hole (4 Places) 3.250 2 1/4″ Dia. Hole 170 Cherry Avenue West Sayville, NY 11796 kussmaul.com 2.125″ 1.875″ KUSSMAUL ELECTRONICS ENERGIZED AND READY, WHEN SECONDS COUNT 1/2″ Dia. Hole (2 Places) Drill these two holes first Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com

****** Page 3 ****** Ill. WIRING THE AUTO EJECT WP 1. 2. 3. Connect one terminal of the solenoid on the Auto Eject WP to the vehicle ground. Use a minimum of 16 AWG wire. Connect the other solenoid terminal to the vehicle’s starter and install a 4 Amp Fuse inline. Use a minimum of 16 AWG wire. Crimp the ring lugs on the wire and connect the Green, Black, and White power wires to the ac- cessories on the vehicle. For Model #’s: 091-18WP-012 and 091-18WP-120, use a minimum of 14 AWG wire. For Model #: 091-20WP-120, use a minimum of 12 AWG wire. IV. FIGURE 2, WIRING THE AUTO EJECT WP 1. Note: Connect the starter circuit so that the solenoid is energized only while the engine is cranking. If the solenoid is energized continuously it will OVERHEAT and BURN OUT and void the warranty. Note: The Auto Eject is on the outside of the truck wall (4) #8 Screw Weather Proof Cover Gasket Truck Wall 170 Cherry Avenue West Sayville, NY 11796 kussmaul.com (4) Hex Nut Note: use 12 AWG wire for 20 amps and 14 AWG wire for 15 amps Green Ground Black Line White Neutral Ring lugs supplied Solenoid To Battery Chassis Ground Vehicle Starter KUSSMAUL ELECTRONICS ENERGIZED AND READY, WHEN SECONDS COUNT Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com 3

****** Page 4 ****** TEST AND OPERATION l. ELECTRICAL TEST Inspect and verify that all wiring is properly connected as illustrated in figure 2. Measure the D.C. voltage across the solenoid. Cranking the engine should create a D.C. voltage approximately equal to the battery voltage and simultaneously cause the plug to eject. II. OPERATION Install the connector in the Auto Eject WP and note that A.C. power is applied to the vehicle mount- ed battery charger. Verify that cranking the engine ejects the shoreline. NOTES AND CAUTIONS l. STARTER CIRCUIT The Auto Eject WP must be connected to the starter circuit so that the solenoid is energized only while the engine is cranking. If the solenoid is energized continuously it will OVERHEAT and BURN OUT. II. CONNECTOR INSTALLATION Do not permit the shore line to drop to the floor when it is ejected. Keep from falling by utilizing a bungee cord restraint, cord reel or some other device. Dropping the connector may result in dam- age or breakage. Kussmaul Electronics does not warrant the connector. Ill. USING THE CORRECT CONNECTORS The Auto Eject WP is supplied with mating connector. Do not replace with similar connectors. Use only the Kussmaul Electronics supplied connector. IV. ANNUAL MAINTENANCE 1. Keep connector and contacts of the Auto Eject WP clean. 2. Clean contacts with WD-40 solvent as required. 3. Lubricate contacts monthly with “vaseline” to insure free operation. 4. Check all gaskets and replace if warn. V. MOUNTING LOCATION If the Auto Eject WP is installed where the rear mechanism can accumulate dirt, grime or water, the 091-18CP, Rear Enclosure, must be installed as well. VI. WARRANTY IMPACT Failure to follow these notes and cautions will void the warranty 170 Cherry Avenue West Sayville, NY 11796 kussmaul.com KUSSMAUL ELECTRONICS ENERGIZED AND READY, WHEN SECONDS COUNT Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com 4

****** Page 5 ****** OPTIONAL ACCESSORIES l. E-Z MOUNTING PLATE, MODEL 091-185-010 Provides an easier installation of the Auto Eject WP Shows an indication of when the line cord has been connected properly • Green Watertight LED indicator II. AUTO REEL, MODEL 091-220-20-120 Automatic shoreline retraction and storage compatible with Auto Eject or by manual disconnection Reduce tripping hazard and liability by removing hazardous cord on the ground Increase productivity during emergency dispatch by automating the electrical disconnection process • Ceiling or Wall mounted Curved edges for Safe and Easy mounting Ill. POWER CORD REEL, MODEL L4545 12 33 45 foot, 12 AWG, 3 conductor cord Spring retractable with latch Wall or ceiling mount Adjustable cord stop 120 VAC CINNECTED 170 Cherry Avenue West Sayville, NY 11796 kussmaul.com KUSSMAUL ELECTRONICS ENERGIZED AND READY, WHEN SECONDS COUNT Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com

****** Page 6 ****** OPTIONAL ACCESSORIES Ill. ALUMINUM ENCLOSURE, MODEL 091-18CP Provides protection from road dirt, grime or water W. DYNAMIC DISCONNECT, MODEL 091-18-098 • Totally eliminates connector arcing Disconnects load before Auto Eject is ejected • Time delay connects load after Auto Eject WP is plugged in 30 Amp Relay Contact Rating V. RUBBER CONNECTOR PROTECTOR, MODEL 091-55-069 Covers the female 5-15P-H, 6-15P-H, or 5-20P-H connector with 1/8″ rubber to protect the connector and nearby vehicles from impact damage 170 Cherry Avenue West Sayville, NY 11796 kussmaul.com KUSSMAUL ELECTRONICS ENERGIZED AND READY, WHEN SECONDS COUNT Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com 4

****** Page 7 ****** SPECIFICATIONS Input Voltage: 10 – 28 Volts DC Input Current: 1.6 Ameres Max Elecrical Rating: Model 091-18WP-012: 12 Volts DC or 250 Volts AC, 15 Amperes Max Model 091-18WP-120: 120 Volts AC, 15 Amperes Max Model 091-20WP-120: 120 Volts AC, 20 Amperes Max Hardware Pack Provided: 3 ring lugs, cover with gasket and mounting screws, mating connector Weight: 2 pounds INSTALLATION RECORD DATE INSTALLED INSTALLED BY VEHICLE IDENTIFICATION VEHICLE OWNER WARRANTY POI-ICY All products of Kussmaul Electronics are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects which become apparent in normal use within 2 years from the date the equipment was shipped. Equipment is to be returned, shipping charges prepaid and will be returned, after repair, shipping charges paid. Kussmaul Electronics shall have no liability for damages of any kind to associated equipment arising from the installation and/or use of the Kussmaul Electronics products. The purchaser, by the acceptance of the equipment, assumes all liabil- ity for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others. Members of Fire and Emergency Manufacturers and Service Association MS Members of National Fire Protection Members of Fire Apparatus Manufacturers Made in USA 170 Cherry Avenue West Sayville, NY 11796 kussmaul.com Association Association NFPA KUSSMAUL ELECTRONICS ENERGIZED AND READY, WHEN SECONDS COUNT AMA Ph: 800-346-0857 Fax: 631-567-5826 sales@kussmaul.com