How do I disassemble the KENWOOD TR-3600E?

To remove the cases and PC boards of your KENWOOD TR-3600E, follow these steps:

1. Depress the release button and pull the battery pack off to the right.

2. Remove the 4 screws from the battery pack bottom plate.

3. Remove the 3 screws from the top and bottom cases.

4. Open the case towards the front by holding it with both hands as shown in the illustration. Note that indented retainers are located on the “hinge” or swing part.

5. Remove the 3 screws from the DCL unit mounting bracket.

6. After removing 4 screws, separate the RX and TX units.

7. Remove the escutcheons from the TX and RX units.


What are the initial settings and important notes for performing adjustments on the KENWOOD TR-3600E?

Before performing adjustments, unless otherwise specified, set the controls on your KENWOOD TR-3600E as follows:

Controls Setup:

POWER/VOL: OFF

KEY LOCK: OFF

TX STOP: OFF

DCS: ON

HI/LOW: HI

SQL VR: MIN

Notes:

• When adjusting the trimmers or coils, use a non-inductive tuning tool.

• When adjusting the RX section, never transmit to prevent damage to the Signal Generator (SSG).

• Connect the MIC connector as shown in the service manual diagram. The SSG output level is indicated as open circuit.


How do I perform a PLL adjustment on the KENWOOD TR-3600E?

PLL ADJUSTMENT
ItemConditionMeasurement EquipmentUnitTerminalAdjustment PartMethodSpecification/Remarks
1. PLL1) FREQ.: 430.000 M2,T,W,X / 440.000 K,M1RF VTVMTXTP2TC8MAX2.0V±0.1V
2) Transmit1.6V or more
3) FREQ.: 439.900 M2,T,W,X / 449.900 K,M1DVM f.counterTXTP1L24,25 TC10Adjust5.2V or less
4) Transmit
5) Receive
Reference level 0.4V
10.4950MHz±100Hz

How do I perform a TX adjustment on the KENWOOD TR-3600E?

TX ADJUSTMENT
ItemConditionMeasurement EquipmentTerminalAdjustment PartMethodSpecification/Remarks
1. PowerFREQ: 435.000 M2,T,W,X / 445.000 K,M1Power meter (5W or 10W), AmmeterANTTC3-7Attach L6. If the current rises above 750mA, reduce the current to 50mA so that the capacity of TC7 increases in ANT, OPEN condition. Maximize the power with TC6.1.5W or more
750mA or less
2. f adjustment1) FREQ: 435.005 M2,T,W,X / 445.005 K,M1
Transmit/Receive
ANTL23435.005.0MHz±100Hz M2,T,W,X
445.005.0MHz±100Hz K,M1
2) FREQ: 435.000 M2,T,W,X / 445.000 K,M1
Transmit/Receive
TC9435.000.0MHz±100Hz M2,T,W,X
445.000.0MHz±100Hz K,M1

How do I adjust the Low Power, Modulation, Tone, DTMF, and Battery Meter settings on the KENWOOD TR-3600E?

ItemConditionMeasurement EquipmentUnitTerminalUnitPartMethodSpecification/Remarks
3. Low powerFREQ: 435.000 M2,T,W,X / 445.000 K,M1
ANT: Power meter
Power meter (3W)ANTTXTC3If the current rises above 400mA, increase the capacity of TC5 to decrease the current below 400mA.0.1–0.6W
400mA or less
4. Modulation1) FREQ: 435.000 M2,T,W,X / 445.000 K,M1
AG: 1kHz, 80mV K,M,X
1kHz, 50mV W,T
Power meter, Coupler, Linear detector, AG, AF VTVM, Oscilloscope, DVMANTTXVR1Linear detection P-P/2±4.5kHz
2) AG: 1kHz, 8mV K,M,X
1kHz, 5mV W,T
VR2-P or +P±4.5kHz±50Hz
±3.0kHz–±3.8kHz
5. Tone1) Connect to TU-35.
Tone FREQ: 88.5Hz
TXCheckDEV±400Hz or more
2) T type onlyVR3Short TP3 to TP4. 1750±10Hz (1740–1760Hz)DEV±2.5kHz or more
3) W type only
TONE SW: ON
TXVR3P-P/2. 1750±10Hz (1740–1760Hz)
6. DTMF K,M,X type onlyFREQ: 435.000 M2,X / 445.000 K,M1
Transmit
RXVR5Check
Depress 1 key
DEV±2.5kHz or more
DEV±3.2kHz
7. BATT meterHI/LOW SW: LOW
Source voltage: 6.5V
Transmit
DVMS meterRXVR4Set to point A.A B
S | 1 | 3 | 5 | 7 | | 10
BATT

How do I perform an RX (Receiver) adjustment on the KENWOOD TR-3600E?

RX ADJUSTMENT
ItemConditionMeasurement EquipmentUnitTerminalUnitPartMethodSpecification/Remarks
1. Sensitivity1) FREQ : 435.100 M2,T,W,X / FREQ: 445.100 K,M1
SSG: 0dB
TX.S SW: ON
SSG, AF VTVM, SP, OscilloscopeSPRXTC1–5Repeat 2 or 3 times on TC1–5.NQ Maximum
2) SSG: 30dBVolt meterS meterTX
RX
TC1,2
T1
S meter Maximum
3) SSG: 40dB (DEV: 5kHz, f: 1kHz)SPRXT2AF Maximum
4) SSG: -6dB (DEV: 3.5kHz, f: 1kHz)Deviation meterFREQ: 430.100, 439.900 M2,T,W,X
FREQ: 440.100, 449.900 K,M1
S/N 12dB or more

How do I adjust the S meter and perform a backup check on the KENWOOD TR-3600E?

ItemConditionMeasurement EquipmentUnitTerminalUnitPartMethodSpecification/Remarks
2. S meterFREQ: 435.100 M2,T,W,X / 445.100 K,M1
SSG: 26dB (MOD: OFF)
S meterRXVR3Set to point B.A B
S | 1 | 3 | 5 | 7 | | 10
BATT
3. Back up checkPOWER/VOL: OFF
Disconnect battery connector.
Connect jig to RX unit D14 as illustrated.
Use jig as illustratedRXD14LED goes off slowly.
Jig components: D1: 1S1555, D2: LED, R: 100Ω

How do I perform an operation check on the KENWOOD TR-3600E?

Caution: K,M1 type shift adjustment frequency to 440 MHz order.

ItemConditionOperation Check
1. Call sign input1) Connect to EXT. SP, POWER/VOL: ON, RESET SW: ONDisplay: S
2) Depress 1 keyDisplay: S _ _ _ _ 1
3) Depress 1 keyDisplay: S _ _ _ 1 1, Tone sounds.
4) Depress 2 key two times.Display: S _ _ _ 2 2, Tone sounds.
5) Depress 3 key two times.Display: S _ _ 3 3, Tone sounds.
6) Depress 4 key two times.Display: S _ 4 4, Tone sounds.
7) Depress 5 key two times.Display: S 5 5, Tone sounds.
8) Depress 6 key two times.Display: S 6 6, Tone sounds.
2. Digital code inputS 4 3 3 . 0 0 0
1) Depress MS keyDisplay: 0 0 0 0 0
2) Depress 1 keyDisplay: _ _ _ _ 1, Tone sounds.
3) Depress 1 keyDisplay: _ _ _ 1 1, Tone sounds.
4) Depress 1 keyDisplay: _ _ 1 1 1, Tone sounds.
5) Depress 1 keyDisplay: _ 1 1 1 1, Tone sounds.
6) Depress 1 keyDisplay: 1 1 1 1 1, Tone sounds.
7) Depress MS keyDisplay: 0 0 0 0 0, Tone sounds.
8) Depress 1 -> 2 -> 3 -> 4 -> 5 keys.Display: 1 2 3 4 5, Tone sounds when key depressed.
9) Depress MS key
10) Depress 6 -> 7 -> 8 -> 9 -> 0 keys.
Display: 0 0 0 0 0, Tone sounds.
Display: 6 7 8 9 0, Tone sounds when key depressed.
3. Call sign, Digital code recall1) Depress C key.Display: S 4 3 3 . 0 0 0
2) Depress F -> 8 keys
3) Depress ▲/▼ keys. Repeat above method 5 times.S 1: 1 1 Tone sounds. S 2: 2 2 Tone sounds. S 3: 3 3 Tone sounds. S 4: 4 4 Tone sounds. S 5: 5 5 Tone sounds. S 6: 6 6 Tone sounds.
S 4 3 3 . 0 0 0, Tone sounds.
4) Depress MS keyDisplay: 6 7 8 9 0, Tone sounds.
5) Depress MS keyDisplay: 1 1 1 1 1, Tone sounds.
6) Depress MS keyDisplay: 1 2 3 4 5, Tone sounds.
7) Depress C keyDisplay: S 4 3 3 . 0 0 0, Tone sounds.
4. Verify scan8) DCL SW: OFFTone sounds.
1) SQ Pot.: Threshold (Reference 8–10 o’clock). Depress ▼ key.Display: S 4 3 2 . 9 9 5, Tone sounds.
2) Depress ▼ key several times.When depressed, tone sounds and frequency is decreased 5kHz.
3) Depress ▼ key continuously.Down scan speed becomes faster.
4) Release ▼ key.Down scan speed becomes slow.
5) SQ Pot.: MIN (Counterclockwise)Scan stops.
6) SQ Pot.: ThresholdScan restarts.
7) Depress C key.Scan stops. Tone sounds.
8) Depress C key.Display: S 4 3 3 . 0 0 0, Tone sounds.
9) Depress ▲ key.Display: S 4 3 3 . 0 0 5, Tone sounds.
10) Depress ▲ key several times.When depressed, tone sounds and frequency increases 5kHz.
11) Depress ▲ key continuously.Display frequency increases faster.
12) Release ▲ keyDisplay frequency increases slowly.
13) Depress F -> 7 keys.[SCAN] is displayed. Display increases every 5 seconds.
14) Depress F -> 9 keys[P.SCAN] is displayed.
15) SQ Pot.: MIN (Counterclockwise)Scan stops. Scan starts.
16) Depress F -> 7 keys.[SCAN] goes off. Scan stops.
17) Depress F -> 9 keys[P.SCAN] goes off. Display increases every 5 seconds.
18) SQ Pot.: Threshold
19) Depress C key
Scan starts. Scan stops.
5. Program scan1) Depress 9 -> 9 -> 9 -> F -> MR -> 9 keys.Display: S 4 3 9 . 9 9 0, Tone sounds.
2) Depress 9 -> 0 -> 0 -> F -> MR -> 8 keys.Display: S 4 3 9 . 0 0 0
3) Depress ▲ -> ▼ -> ▲ keys.Display: S 4 3 9 . 0 3 0
4) Depress F -> ▲ keys.Tone sounds.
5) Depress F -> ▼ keys.PROG.S is displayed. Display scan from 439.000 in 30kHz steps.
6) Depress C key.Scan stops.
6. ALERT1) Depress F -> 0 keys.ALERT is displayed.
2) SQ Pot.: MIN (Counterclockwise)The tone sounds every 6 seconds.
3) Depress F -> 0 keysALERT goes off.
4) Depress C key.
7. Repeater1) Depress 9 -> 0 -> 0 -> F -> MR -> 0 keys.Display: S 4 3 9 . 0 0 0
2) Depress C -> C keysDisplay: S 4 3 3 . 0 0 0
3) REV SW: PushDisplay: + 4 3 3 . 0 0 0
4) Depress F -> 3 keysDisplay: M + 4 3 3 . 0 0 0
5) REV SW: PushDisplay: + 4 3 8 . 0 0 0
6) Depress F -> 2 keysDisplay: M- 4 3 3 . 0 0 0
7) REV SW: PushDisplay: – 4 3 9 . 0 0 0
8) Depress F -> 1 key.Display: – 4 3 3 . 0 0 0
9) REV SW: PushDisplay: – 4 3 3 . 0 0 0
10) Depress F -> MS key.Display: – 4 3 3 . 0 0 0
11) REV SW: PushDisplay: – 4 3 0 . 0 0 0
12) Depress F -> 5 keys.Display: S 4 3 3 . 0 0 0
8. Memory input1) Depress 0 -> 0 -> 0 -> F -> MR -> 1 keys.Display: 4 3 0 . 0 0 0
2) Depress 5 -> 0 -> 0 -> F -> MR -> 2 keys.Display: 4 3 5 . 0 0 0
3) Depress 5 -> 1 -> 0 -> F -> MR -> 6 keys.Display: 4 3 5 . 1 0 0
4) Depress 0 -> 1 -> 0 -> F -> MR -> 7 keys.Display: 4 3 0 . 1 0 0
9. Verify MS1) Depress the MS key.MS is displayed.
2) SQ Pot.: ThresholdScan channel 1 to 0 in order.
3) Depress MS and 2 key at the same time.Channel 2 is skipped.
4) Depress C key.MS goes off. Scan stops.
5) Depress MR key1 2 6 7 8 9 0 is displayed.
6) Depress 2 key4 3 5 . 0 0 0★ is displayed.
7) Depress MR and 2 keys at the same time. Depress C key. Depress MR -> 2 keys.★ should not be lit.

What are the specifications of the BC-2 Battery Charger for the KENWOOD TR-3600E?

Part No.W09-0317-05W09-0318-05
RatingPrimary side: AC220V 50/60 Hz
Secondary side: DC 10.15V, DC 42.5mA
Primary side: AC 240V 50 Hz
Secondary side: DC 10.15V, DC 42.5mA
Output voltage (resistance loaded)At 0mA: DC 12.5V ±5%
At 42.5mA: DC 5.5V ±5%
At 0mA: DC 12.6V ±5%
At 42.5mA: DC 5.6V ±5%
WeightAbout 240gAbout 220g
Consumed power4W or less with 50 Hz at rated input and battery loaded.4W or less with 50 Hz at rated input and battery loaded.
DestinationEuropeEngland

What are the specifications of the optional accessories for the KENWOOD TR-3600E?

BT-3 (AA MANGANESE/ALKALINE BATTERY CASE)

• Battery: AA Manganese/Alkaline battery x 6 pcs

• Voltage: 9V (1.5V x 6)

• Dimensions: 66 (W) x 52 (H) x 40 (D) mm

EB-3 (EXTERNAL C MANGANESE/ALKALINE BATTERY CASE)

• Battery: C Manganese/Alkaline battery x 6 pcs

• Voltage: 9V (1.5V x 6)

• Dimensions: 63 (W) x 175 (H) x 34 (D) mm

PB-26 (Ni-Cd BATTERY)

• Nominal voltage: 8.4V, 450mAh

• Recharge time: Approx. 15 hours when fully discharged (with supplied charger or MS-1). Approx. 1.5 hours (with ST-2).

• Working time: Depends on transceiver, operating habits.

• Charge/discharge cycle: Approx. 300 cycles

DC-26 (DC-DC CONVERTER)

• Input voltage: 13.8V DC ± 15%

• Output voltage: 8.4V DC ± 5%

• Output current: 800mA (at input voltage of 13.8V DC, with max. load)

• Weight: Approx. 110g

• Accessories: Instruction manual, 1; Spare fuse (2A), 1.

HMC-1 (HEADSET WITH VOX)

• Mic input sensitivity: 1.5mV (1kHz)

• Delay time: Approx. 1.2 sec.

• DC current: 3.5mA

TU-35A (REPEATER TONE UNIT)

• Oscillator frequency: 88.5 Hz (±0.2 Hz) at normal temperature

• Frequency adjustment range: 60 ~ 260 Hz

• Weight: 8 grams

TU-35B (REPEATER TONE UNIT)

• Oscillator frequency: 1 MHz ± 0.1%

• Usable frequency range: 37 EIA Specification Group Frequencies (67.0 – 250.3 Hz)

• Weight: 8 grams

MS-1 (MOBILE STAND CHARGER)

• Dimensions: 79(W) x 180(H) x 53(D) mm

• Weight: 350g

• Input source voltage: DC13.8V±15%

• Output voltage: DC9.0V

• Charging current: About 45mA (DC 13.8V)

• Charging time: About 15 hrs.

SMC-30 (SPEAKER MICROPHONE)

• Speaker: 40mmφ, 0.5W Max. Input, 8Ω Input impedance

• Microphone: Electret condensor, -67dB Sensitivity, 2kΩ Output impedance, 200Hz~5kHz Frequency response

• Operating temperature: -20°C~+60°C

• Dimensions: 51W x 73H x 33D (mm) (Projections excluded)

• Weight: 130g (Cord included)

ST-2 (BASE STAND)

• Power Source Voltage: 220V 50/60Hz (W TYPE), 240V 50/60Hz (T TYPE)

• Dimensions: 185 (W) x 72 (H) x 115 (D) mm

• Weight: 1.5 kg

• DC Power Source Unit: 9.0V Output Voltage, 0.8A Output current

• Charging Power Source Unit: Boosting charge type, Boosting charge approx. 600mA, Trickle charge approx. 20mA, Boosting charge time approx. 1 hr, Trickle charge time approx. 20 hrs


What are the general specifications for the KENWOOD TR-3600E?

Frequency Range: 430.000–439.995MHz (M2,T,W,X)

Memory Channels: 10CH

Mode: FM (F3), (F2 in DCS mode)

Operating Voltage: 8.4V DC ±25%

Power Requirement: 8.4V, 450mAH (Ni-Cd battery pack); 9V manganese or alkaline (not Ni-Cd); 6 “C” CELL battery case (option)

Back-up Power Requirement: CR-2032 Lithium battery

Current Drain: Approx. 35mA in receive mode with no input signal; Less than 750mA in HI transmit mode (at 8.4V); Less than 400mA in Low transmit mode (at 8.4V); Less than 1μA for memory back-up

Grounding: Negative

Operating Temperature: -20°C to +50°C

Antenna Impedance: 50Ω

Dimensions: With Ni-Cd battery: 66(2.6)W x 168(6.7)H x 40(1.6)D mm (inch); With manganese battery: 66(2.6)W x 176(7.0)H x 40(1.6)D mm (inch)

Weight: With Ni-Cd battery: 540g (1.2lbs.); With manganese battery: 530g (1.2lbs.)


What are the transmitter specifications for the KENWOOD TR-3600E?

RF Output Power: HI = 1.5W, LOW = 0.3W approx.

Modulation: Variable reactance direct shift

Frequency Tolerance: Less than ±20 x 10⁻⁶ (-10°C~+50°C)

Maximum Frequency Deviation: ±5kHz

Spurious Radiation: Less than -60dB


What are the receiver specifications for the KENWOOD TR-3600E?

Circuitry: Double conversion superheterodyne

Intermediate Frequency: 1st IF = 21.6MHz, 2nd IF = 455kHz

Sensitivity: Better than 1μV for S/N 30dB; Less than 0.25μV for 12dB SINAD

Pass-Band Width: More than 12kHz (-6dB)

Selectivity: Less than 24kHz (-40dB)

Spurious Response: Better than 50dB

Squelch Sensitivity: Less than 0.25μV (threshold)

Audio Output Power: More than 400mW (at 10% distortion and 8Ω load)