INTERMATIC T104 (01) PDF MANUAL


Post questions, comments, reviews or errors in the comment box below.

Your File is Ready … Download PDF

CLICK HERE TO DOWNLOAD INTERMATIC T104 (01) PDF MANUAL


PDF Content Summary: MODEL: T104 24 HOUR DIAL TIME SWITCH LR3730 TYPE 1 INDOOR USE ONLY DOUBLE POLE SINGLE THROW (DPST) 40 A RESISTIVE EACH POLE, 120-480 VAC UL 40 A INDUCTIVE, TUNGSTEN OR 1000 VA HOLOGRAM PILOT DUTY EACH POLE 120V-277 VAC; LABEL 2 HP (24 FLA) - 120 VAC; 5 HP (28 FLA) - 240 VAC 16 A ELECTRONIC BALLAST, 277 VAC WARNING Risk of Fire or Electric Shock • Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing. • Installation and/or wiring must be in accordance with national and local electrical code requirements. • Use wires rated at least 90°C - COPPER conductors ONLY. • Replace plastic insulator covering terminals before powering ON. • KEEP DOOR CLOSED AT ALL TIMES when not servicing. AVERTISSEMENT Risque d’incendie ou de choc électrique • Utiliser des fils classés 90 °C minimum - Conducteurs en CUIVRE UNIQUEMENT. NOTICE • Rotate timer dial clockwise only. • Do not move the clock hands on the timer. Moving the clock hands can damage the timer. CLOCK MOTOR CLOCK VOLTAGE MOTOR: AND CYCLE 208-277 MUST VAC, BE AS 60 SPECIFIED. HZ. TO ORDER REPLACEMENT, INDICATE PART NO. (WG--) ON MOTOR COVER. TIME DIAL WIRING DIAGRAM 240 AND V GROUND 2 WIRE TIME POINTER GR A 1 2 3 4 OFF TRIPPER SUPPLY 240V LINE 1 LINE 2 TOLOAD(S) MANUAL LEVER 277/480 VOLT CONNECT MOTOR LEADS TO TERMINALS “A” AND 1 AND SUPPLY NEUTRAL TO TERMINAL “A”. WIRING INSTRUCTIONS: Remove 1/2 inch of insulation from wire ends. Tighten terminal screws firmly (2-18 in-lbs). Use solid or stranded COPPER conductors only. May use two wires of the same size and type. MINIMUM COPPER 75°C PROGRAMMING INSTRUCTIONS 1. TO SET “ON” AND “OFF” TIMES: Hold trippers against edge of CLOCK- DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. For additional tripper pairs on CLOCK-DIAL order 156T1978A. 2. TO SET TIME-OF-DAY: Pull CLOCK-DIAL outward. Turn in either direction and align the exact time-of-day on the CLOCK-DIAL (the time now, when switch is being put into operation) to the pointer. DO NOT MOVE POINTER. OPERATING INSTRUCTIONS • TO OPERATE SWITCH MANUALLY: Move MANUAL LEVER below CLOCK- DIAL left or right as indicated by arrows. This will not effect next operation. • IN CASE OF POWER FAILURE, reset CLOCK-DIAL to proper time-of-day. See programming instructions. INTERMATIC INCORPORATED SPRING GROVE, ILLINOIS 60081-9698 154--02030 INSULATION MAX. MOTOR LOAD (HP) WIRE SIZE (AWG) SINGLE PHASE 3 PHASE 120 V. 240 V. 208 V. 240 V. 1412108 15203040 90909090 1/212- 2 2 1/2 35 N/A N/A MAX. LOAD (AMP) MIN. INSUL- ATION TEMP(°C) ON TRIPPER PRESSURE PLATE TERMINAL SCREW MAKE SURE WIRE INSULATION CLEARS PRESSURE PLATE CLOCK MOTOR GROUND


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE - USER MANUAL

OWNER GUIDE - OWNER MANUAL

REFERENCE GUIDE - REFERENCE MANUAL

INSTRUCTION GUIDE - INSTRUCTION MANUAL

Leave a Reply