INNOVATIVE IED IED1522LR (01) PDF MANUAL


Post questions, comments, reviews or page errors in the comment box below.

Click here to download INNOVATIVE IED IED1522LR (01) PDF MANUAL


PDF Content Summary:

****** Page 1 ****** QUICK START GUIDE INTRODUCTION IEDI 522LR LOGIC/RELAY MODULE Logic / Relay Module Quick Start Guide The 1522LR Logic / Relay Module is a cost effective interface module that operates as an integral part of an IED GLOBALCOM system. It is a web-enabled, programmable relay device for a wide variety of remote control and automation applications. It has two electro-mechanical relays, two optically-isolated inputs, and a wealth of cutting-edge features. The relays can be controlled remotely using actions configured in the GLOBALCOM control software. The optically-isolated inputs can be used to trigger actions or as logic monitor points that will register faults in the system. The module receives its power over IEEE 802.3af POE (Power over Ethernet) and communicates with other system devices over the Ethernet network. BASIC SETUP PROCEDURE 1. 2. 3. 4. 5. 6. 7. 8. 9. Connect unit to power and network. Set up a computer on the same network as the input module. To do this, set the IP address of the computer to 10.2.150.x (where “x” can be any unused address between 1 and 174) with a netmask of 255.0.0.0. Configure the 1522LR using web browser. Do this by pointing browser to 10.2.150.175/setup.html. The login username is admin and the password is iednet (all lower case). Set the permanent IP address, subnet mask and (optionally) the gateway address in the setup page under the Network tab. If the host network supports it, change the Speed to 100 Mbps and the Mode to Full Duplex, also in the Network tab. Submit the changes via the Submit button on the web page. Reset the 1522LR via either the Reset button on the web page or by removing and re-applying power to the unit. Next, set the computer back to its original or desired network settings for the installation and verify that the 1522LR can be accessed at its new (permanent) IP address. Proceed to connect logic inputs and relay outputs as needed for the application. 1522LR Pinout power supply Factory Default Settings IP Address: Subnet Mask: Control Web Address: Setup Web Address: Setup Username: Setup Password: Control Password: Innovative Electronic Designs, LLC 9701 Taylorsville Road Louisville, KY 40299, USA REV: 04-14 10.2.150.175 255.0.o.o 10.2.150.175 1 0.2.150.175/setup.html admin iednet (all lower case) no password set + 1.502267.7436 phone + 1.502.267.9070 fax iedaudio.com DOC: 1214D Vin+ * Vin— Gnd Inl- 1172+ ln2- INC INO CPU 20 2NC 2NO CPU Power Supply Input + Power Supply Input • +5V DC output (50mA max) Ground (common) for 5V out Optically-Isolated Input 1 + Optically-Isolated Input 1 – Optically-Isolated Input 2+ Optically-Isolated Input 2• Relay 1 common Relay 1 Normally Closed Relay 1 Normally Open Relay 2 Common Relay 2 Normally Closed Relay 2 Normally Open * – Power supply input terminals not used when device is connected to POE source nanäk C n i cati on S Group 02014, Innovative Electronic Designs, LLC

****** Page 2 ****** QUICK START GUIDE IEDI 522LR LOGIC/RELAY MODULE Logic / Relay Module Quick Start Guide MAKING LOGIC CONNECTIONS The logic inputs on the 1522LR are opto-isolated, which means they require a voltage differential to activate, not a simple open/closed condition. If connecting to dry contacts, a “wetting voltage” will have to be applied. The 1522LR has a built-in power supply and connections to supply just such a voltage. The proper way to connect a dry contact is to connect the power supply ground to the minus logic input and then connect the power supply voltage output to the plus logic input via the contact. This wiring arrangement is shown in the diagram below. DRY Vout Gnd In 1, LOST IP ADDRESS 1522LR comes from the factory with the default IP address of 10.2.150.175. If the IP has been set to something else and one does not know the IP address of a 1522LR, one of two things can be done: (1) reset it to the factory default IP address or (2) assign it a temporary IP address. Innovative Electronic Designs, LLC 9701 Taylorsville Road Louisville, KY 40299, USA REV: 04-14 + 1.502267.7436 phone + 1.502.267.9070 fax iedaudio.com DOC: 1214D nanäk C n i cati on S Group 02014, Innovative Electronic Designs, LLC

****** Page 3 ****** QUICK START GUIDE IEDI 522LR LOGIC/RELAY MODULE Logic / Relay Module Quick Start Guide RESTORING FACTORY DEFAULT SETTINGS In the event that the IP address or passwords are forgotten, the 1522LR may be restored to its original factory default settings. To do this, first remove the power from the unit. Next, carefully insert a thin object (such as a toothpick) through the small hole in the bottom of the unit to press the small button that is located inside the unit. When the object is inserted, a tactile feel can be detected as the button is depressed. While holding the button down, apply power and wait for about 10 seconds. After about 10 seconds, release the button. Now all settings will be back to the original factory defaults. Reset Button Access Hole CAUTION — Do NOT use metal objects for this function. ASSIGNING A TEMPORARY IP ADDRESS The device will retain the temporary address until power is reset to it. How to set it depends on the host system you are working from. Windows: Open a Command Prompt (select START, then RUN, then type “cmd”). Note: for Vista, the Command Prompt should be run as administrator (select Start, then type “cmd” and right click on “cmd” and select “Run as administrator”). Type: arp -s {new IP address} {serial number of the 1522LR } Note: IP address format is xxx.xxx.xxx.xxx Serial number format is ss-ss-ss-ss-ss-ss (I.e., the MAC address) For example, to set a IEDI 522LR (with serial number 00-0C-C8-01-00-01) to 10.10.10.40 the following command would be used: arp -s 10.10.10.40 00-00-08-01-00-01 Next, type: ping -1 102 {new IP address} (The character after the dash is a lowercase “L”.) For example, if the new IP address is 10.10.10.40, the following command would be used: ping -1 102 10.10.10.40 Innovative Electronic Designs, LLC 9701 Taylorsville Road Louisville, KY 40299, USA REV: 04-14 + 1.502267.7436 phone + 1.502.267.9070 fax iedaudio.com DOC: 1214D nanäk C n i cati on S Group 02014, Innovative Electronic Designs, LLC

****** Page 4 ****** QUICK START GUIDE IEDI 522LR LOGIC/RELAY MODULE 522LR Logic / Relay Module Quick Start Guide Assigning a Temporary IP Address (Continued) Linux/Unix Open a terminal, change to root user (su then enter root password). Type: arp -s {new IP address} {serial number of the 1522LR } Note: IP address format is xxx.xxx.xxx.xxx Serial number format is ss:ss:ss:ss:ss:ss (i.e., a MAC address) For example, to set the 1522LR (with serial number 00-0C-C8-01-00-01) to 10.10.10.40 the following command would be used: arp -s 10.10.10.40 Next, type: ping -s 102 {new IP address} For example, if the new IP address is 10.10.10.40, the following command would be used: ping -s 102 10.10.10.40 Mac OS X Open a terminal. Note that the terminal is in the “Utilities” directory, which is in the ‘Applications” directory. Type: sudo arp -s {new IP address} {serial number of the 1522LR } Note: Administrator password is required. IP address format is xxx.xxx.xxx.xxx Serial number format is ss:ss:ss:ss:ss:ss (i.e., the MAC address) For example, to set a 1522LR (with serial number 00-0C-C8-01-00-01) to 10.10.10.40 the following command would be used: sudo arp -s 10.10.10.40 Next, type: ping -s 102 {new IP address} For example, if the new IP address is 10.10.10.40, the following command would be used: ping -s 102 10.10.10.40 Innovative Electronic Designs, LLC 9701 Taylorsville Road Louisville, KY 40299, USA REV: 04-14 + 1.502267.7436 phone + 1.502.267.9070 fax iedaudio.com DOC: 1214D nanäk C n i cati on S Group 02014, Innovative Electronic Designs, LLC