****** Page 1 ****** APPLICATION The 1000-ohm, three-watt 4074FAB Resistor is used in certain applications to assure compatibility with power- stealing thermostats. Use this Resistor When Installing... • Forced air systems using ST9120 or ST9141 Electronic Fan Timer. Taco zone valve applications. Trane electric heat air handlers. • Oil systems using Honeywell R8184 Oil Primaries. • Cool only applications. INSTALLATION When Installing this Product... 1. 2. 3. 4. Read these instructions carefully. Failure to follow them could damage the product or cause a haz- ardous condition. Check the ratings on the resistor to make sure the resistor is suitable for your application. Installer must be a trained, experienced service technician. After installation is complete, check out product operation as provided in these instructions. CAUTION Electrical Hazard. Can Cause Electrical Shock or Equipment Damage. Disconnect power supply before installing resis- tor. To Install The Resistor 1. 2. 3. Loosen terminal screws as shown in the applica- tion drawing. Slide the resistor leads under the terminal screws and tighten the screws. Turn on the system power. Honeywell 4074FAB Resistor INSTALLATION INSTRUCTIONS ST9120A-G DISCONNECT POWER SUPPLY BEFORE INSTALMTION. M16650 Fig. 1. Connect resistor to ST9141 Fan Timer terminals C and W. THERMOSTAT TACO ZONE VALVE RESISTOR (HOT) POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED, BEND RESISTOR AWAY FROM ZONE VALVE CASE MI 5401 A TO PREVENT SHORTING. Fig. 2. Connect resistor to Taco zone valve terminals 1 and 2. 69-1371-1 U.S. Registered Trademark Copyright 0 2003 Honeywell International Inc. • • All Rights Reserved

****** Page 2 ****** 40744B TERMINAL BOARD CONNECTION TO THERMOSTAT W TERMINAL B TERMINAL (OPTIONAL) 1 DISCONNECT POWER SUPPLY BEFORE INSTALLATION. M16653 Fig. 3. Connect resistor across terminals W and B on Trane electric heat air handlers. R8184G o RESET DISCONNECT POWER SUPPLY BEFORE INSTALLATION. BE SURE RESISTOR IS MOUNTED ON LOWER M16651 T AND F TERMINALS. Fig. 4. Connect resistor to R8184 Oil Primary terminals T and F. Automation and Control Solutions 4074FAd COMPRESSOR CONTACTOR (HOI) POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M16652 Fig. 5. Connect resistor for cool only application. CHECKOUT 1. 2. 3. Set the thermostat heating setpoint to 100F (60C) above the room temperature. Watch the thermostat display for approximately five minutes to be sure the display does not go blank during the call for heat. Reset the thermostat to a comfortable setpoint. Honeyvvell International, Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honemell Limitée 35 Dynamic Drive Scarborough, Ontario MIV 4Z0 69-1371-1 GH_ 9-03 Honeywell wwwhoneywell.com/yourhome


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE - USER MANUAL

OWNER GUIDE - OWNER MANUAL

REFERENCE GUIDE - REFERENCE MANUAL

INSTRUCTION GUIDE - INSTRUCTION MANUAL

Leave a Reply