What should I do if the thermometer malfunctions or has been damaged?
Do not use the thermometer if it malfunctions or has been damaged in any matter.
What should I do when the ambient temperature changes too much?
Allow the thermometer to remain in a room for 30 minutes where the temperature is between 15℃ to 40℃ (59℉- 104℉).
What mode should I select to measure human forehead temperature and other objects?
If measuring human forehead temperature, select “body” mode; for measuring other objects, liquids, food, and other temperature, please select “surface” mode.
What should I do if there is fog on the sensor?
If the ambient environment was mutations, please should be note whether there is fog on the sensor, if any, before using accordance with the “Care and Storage” section to removing the fog.
What should I avoid so as not to impact the accuracy of the measurement data?
Do not near strong electrostatic field or strong magnetic fields.
What should I do if I have any doubt about the measuring result of this product?
If you have any doubt, please measure the temperature in other methods. The measuring result of this product is only for your reference.
What should I do with the device when it is not in use?
When not in use, store the device in a dry room and protect it against extreme moisture, heat, lint, dust, and direct sunlight. Never place any heavy objects on the storage case.
What should I do if I think the device is damaged or notice anything unusual?
Do not use this device if you think it is damaged or notice anything unusual.
What should I do if the device is damaged/degraded/loosened in any way?
Do not use the device if it is damaged/ degraded/loosened in any way. The continuous use of a damaged unit may cause injury, improper results, or serious danger.
How do I install the batteries?
- Pull the battery downward, toward the bottom of the Non Contact Infrared Body Thermometer, and remove the battery access door;
- Insert two pieces AAA size batteries according to the “+” and “-”;
- Close the battery cover.
How do I measure body temperature?
The thermometer is aligned with the middle of the forehead to measure body temperature (between the eyebrows above) and keep the vertical distance, press the On/measure button, temperature display immediately.
What should I do when people move from one place of lower temperature to another place of higher temperature?
When people moving from one place of lower temperature to another place of higher temperature, should at least remain in the test environment more than 5 minutes, to be consistent with the ambient temperature after the re-measure-ment.
How long should I wait for the next measurement?
Wait at least 1 second for the next measurement. If the continuous measurement of five times, it is recommended to wait at least 30 seconds and then continue measurement.
Where can I try to align if, for some reason, the low forehead temperature measurement?
If for some reason the low forehead temperature measurement can try to align behind the ears.
What are the steps to start measuring?
- Turn on the thermometer by pressing the On/measure button. The thermometer will perform self-test with all segments displayed for 2 seconds.
- Align staff forehead to keep the distance, and then press the On/measure button to start the measurement, read the data.
What does green, yellow, and red mean when the target value of the measured temperature is displayed on the LCD?
Green means ready for next measurement. When 37.4℃-38.0℃, it’s yellow, means slight fever warning. Please pay attention to body temperature. When the body temperature is above 38.1℃, it’s red, means high fever. Please take action to cool down or go for a doctor.
How long should I wait to ensure the accuracy of the measurement?
To ensure the accuracy of the measurement, wait at least 30 seconds after 5 consecutive measurements.
How do I set the unit to Fahrenheit?
Under the boot mode, long press SET button to enter F1, press the “MODE” or “MEMO” button to switch Celsius and Fahrenheit temperature units, press the SET button to confirm the unit settings (factory default is Celsius).
How do I set the fever alert?
Under F1 state, press SET button to enter the F2, press the “MODE” button to decrease 0.1 ℃, press the “MEMO” button plus 0.1 ℃, long press to accelerate the speed of temperature regulation, and finally press the SET button to save (The factory default is 38.1 ℃).
How do I set the prompt sound settings?
Under F2 state, short press SET button to enter F3, press MODE button or MEMO button to set voice switch, and press the SET button to confirm the settings (The factory default is the voice Prompt to open).
How do I turn on or off the prompt sound function?
Under the boot mode, short press SET button to take on or take off the Prompt sound function.
How do I restore to factory setting function?
Under the boot mode, long press MODE button until LCD display “rst”. Two seconds later, former F1-F3 parameter back to factory setting.
How do I convert between “body” mode and “surface” mode?
When the device is running, pressing the MODE button to cycle conversion between “body” mode and “surface” mode. The factory default is “body” mode.
How many temperature readings can be stored in memory?
Up to 50 temperature readings can be stored into the memory cells and automatically overwrite historical data.
How do I clear all stored data?
In boot mode, press the MEMO button until the LCD display “CLR”, which means that all stored data is cleared completelyconds after the long beep, which means that all stored data is cleared completely.
What steps should I take to replace the battery?
- Open and release battery cover following indicator on the surface of battery cover. Before changing the battery be sure the system is already power off.
- Remove the battery and replace it with 2 new ones, type AAA, Make sure align properly as indicated inside the battery cover.
- Slide the battery cover back in until it snaps in place.
What should I do if the system is latched up after changing the battery?
In case, if system is latched up after changing battery. You may not follow up the process of rule one. Just take off battery, waiting 30 sec, then load battery again.
What measured distance is recommended?
Measured over the distance:1-5cm (0.4-2in). Optimum measurement distance is 1cm.
What should I do if the battery capacity is too low?
Install a new battery.
What should I do if the ambient temperature changes too fast?
Move to a room within the operating range wait 30 minutes before taking temperature.
How do I clean the device?
Use a clean, soft cloth to clean the surface of the device and LCD. Do not use solvents or immerse the device into water or other liquids.
What should I do with used batteries?
Used Batteries should be deposited at a collection point.
What do I do if I have any problems with this device?
If you have any problems with this device, such as setting up, maintaining, or using, please contact with SERVICE PERSONNEL of HeTaiDa Technology Co., Ltd. Don’t open or repair the device by yourself.
What should I report to HeTaiDa Technology Co., Ltd.?
Please report to HeTaiDa Technology Co., Ltd. if any unexpected operation or events occur.
How often does the device need calibration to ensure proper function?
Calibration is needed to ensure proper function for every two years or after device impact.
What should I be cautious about regarding EMC?
Do not use a mobile phone or other devices that emit electromagnetic fields near the unit, as this may result in incorrect operation. This machine should not be used adjacent to or stacked with other equipment, and if adjacent or stacked use is necessary, the machine should be observed to verify normal operation in the configuration in which it will be used.
CLICK HERE TO DOWNLOAD HETAIDA HTD8813 (01) PDF MANUAL
How do I get Warranty service for this device
How do i get service for Robert Wood Johnson Barnabas Healthcare (Barnabas Health Medical Group) I am a biomed and we bought many of your model HTD8813C thermometers in approximately April 2020 and this particular one serial number 2003054E11286 lit# 204E02 has a battery door that will not stay secure without taping it closed, how do we get it replaced or repaired? There may be others with similar issues.
My email and number are above, i tried your 400 836 9986 phone number and it wouldn’t go thru, please contact me 7-3 estime. Tnx
Try contacting Hetaida from their website hetaida.com.cn about your product issues. Hope this helps.
I am unable to understand your manual, it was written by a person(s) who are unable to translate it into US English.
I do not get 3 beeps but a single beep after a forehead reading is given.
I am unable to change setting from C° as already programmed on device to F° . How do I make that change.
On page 13 of the manual it says “Under the boot mode. Long press SET button to enter F1, press the “MODE” or “MEMO” button to switch Celsius and Fahrenheit temperature units, press the SET button to confirm the unit settings (factory default is Celsius).”