What are the basic safety attentions that must always be followed when using the GODOX ML100 BI?

First of all, as the most basic principle: This product is a professional lighting set equipment and should be used by professional lighting engineers or under the guidance of professionals. Basic safety attentions must always be followed during use, as follows:

1. Before use, please read and understand these instructions and attentions.

2. Professional lighting is prohibited for children. When children are near, parents or accompanying persons must supervise closely to prevent children from personal injury due to collision with lamps or private use of lamps.

3. This lighting product is not ordinary lighting product and cannot be used for general lighting. Anyone who has suffered eye damage or has sensitive eyes should avoid using this product.

4. When the lamp is on, it must be used with care. Do not touch high-temperature parts, such as LED lamp beads, to avoid burns.

5. When the lamp is on, it is forbidden to look directly at the lamp beads under any circumstances. Strong light should be used under the guidance of professional lighting engineers. Avoid prolonged exposure to strong light under any circumstances. If eye discomfort, please turn off the lamp in time, suspend use, and see a doctor immediately.

6. If the lamp bead is damaged or deformed by heat, stop using this equipment, and contact the manufacturer, service agent or qualified maintenance personnel to replace the lamp bead in time to avoid accidents.

7. This product is only suitable for use in -10°C to 40°C operating environment and normal humidity environment.

8. Do not use damaged equipment or accessories, and wait for professional maintenance personnel to check and repair to confirm being normal before use.

9. During using, if the casing of this product is broken due to being dropped, squeezed or subjected to strong impact, please do not use it, so as to avoid electric shock injury due to contact with internal electronic components.

10. Be sure to unplug equipment from the power outlet before cleaning and repairing. When not in use, do not pull the power cord to unplug the equipment. For normal power-off, please hold both ends of the plug of the equipment with your hands and pull the plug out of power outlet. This equipment needs to be connected to a grounded outlet.

11. This equipment is not waterproof, please keep it dry and do not immerse it in water or other liquids. The equipment should be installed in a dry and ventilated place, and avoid using it in rainy, humid, dusty or overheated environments. Do not place any objects on the lamp or let liquid flow into the lamp to avoid accidents.

12. Do not disassemble the product without permission. If the product fails, it must be checked and repaired by authorized maintenance personnel.

13. Before storing, make sure that the equipment has cooled down completely. For storage, unplug the power cord from the equipment. The equipment should be placed in the carrying case or in a ventilated dry place.

14. Do not place equipment near flammable and volatile solvents such as alcohol and gasoline.

15. Do not use accessories that are not recommended by our factory to avoid fire, electric shock or personal injury.

16. When cleaning, do not wipe it with a damp cloth, please use a dry cloth or a soft cloth to wipe the dirt of the equipment.

17. Please take off the protective cover before using.

18. This product complies with ROHS, CE, and FCC certification, please refer to the relevant national standards for use and operation.

19. The safety instructions are formulated according to the strict testing of the factory, and the design and specifications of the equipment are subject to change without prior notice. For latest product information, please check the GODOX website and view latest electronic instruction.


What are the dimensions and net weight of the GODOX ML100 BI (excluding the lens reflector)?

The dimensions of the GODOX ML100 BI (Excluding lens reflector) are approximately 4.80″ x 4.33″ x 1.81″.

The net weight of the GODOX ML100 BI (Excluding lens reflector) is approximately 487g.


How do I install the Lamp Head Protective Cover on the GODOX ML100 BI?

Align the lamp head protective cover with the Godox mount and insert it. Rotate the lamp head protective cover clockwise until you hear a “click” sound, indicating that the installation is complete.


How do I remove the Lamp Head Protective Cover from the GODOX ML100 BI?

While pushing the lamp fixture’s mount locking pusher, rotate the lamp head protective cover counterclockwise to remove it.


How do I install the Lens Reflector on the GODOX ML100 BI?

Align the lens reflector with the Godox mount on the device and insert it. Rotate the lens reflector clockwise until you hear a “click” sound, indicating that the installation is complete.


How do I remove the Lens Reflector from the GODOX ML100 BI?

While pushing the lamp mount locking pusher, rotate the lens reflector counterclockwise to detach it.


How do I power On/Off the GODOX ML100 BI?

After connecting the power supply, continuously press the power switch button to turn the device on or off.


How do I use the CCT Mode on the GODOX ML100 BI?

Press the MODE/ ⚙️ button briefly to switch modes. When the display screen shows “CCT,” it indicates that the current mode is the color temperature mode. Press the select dial briefly to select between CCT/Brightness.

When selecting CCT, scroll the select dial to adjust the CCT value. Scroll up once to increase CCT by 100K, and scroll down once to decrease CCT by 100K. The CCT range is from 2800K to 6500K.

When selecting brightness, scroll the select dial to adjust the brightness value. Scroll up once to increase the brightness by 1%, and scroll down once to decrease the brightness by 1%. The brightness range is from 0% to 100%.


How do I use the FX Mode on the GODOX ML100 BI?

Press the MODE/ ⚙️ button briefly to switch modes. When the display shows “FX,” it indicates that the current mode is the FX Mode. Press the select dial briefly to select lighting effects/lighting effect parameters/brightness.

When selecting lighting effects, scroll the select dial to choose from the 11 available lighting effect types.

When selecting lighting effect parameters, scroll the select dial to adjust specific lighting effect parameters within the range specified in the table below.

When selecting brightness, scroll the select dial to adjust the brightness value. Scroll up once to increase the brightness by 1%, and scroll down once to decrease the brightness by 1%. The brightness range is from 0% to 100%.


What are the FX lighting effects available on the GODOX ML100 BI?

No. FX Icon FX Type Option Adjustable Range
1 (icon of a spark) FLASH SPD 1-100
2 (icon of a lightning bolt) LIGHTNING FREQ RANDOM/2-20
3 (icon of clouds) CLOUDY SPD RANDOM/1-100
4 (icon of an exclamation point in a lightbulb) BROKEN BULB SPD 1-100
5 (icon of TV) TV SPD 1-100
6 (icon of a candle) CANDLE SPD 1-100
7 (icon of fire) FIRE SPD 1-100
8 (icon of fireworks) FIREWORKS SPD 1-100
9 (icon of an explosion) EXPLOSION SPD 1-100
10 (icon of welding sparks) WELDING SPD 1-100
11 (icon of SOS) SOS CCT 2800K-6500K

How do I access the Bluetooth Settings on the GODOX ML100 BI?

Continuously press the MODE/ ⚙️ button to enter the Bluetooth settings. Scroll the select dial to select Bluetooth Reset (RESET)/Bluetooth On (ON)/ Bluetooth Off (OFF).


How do I perform a Bluetooth Reset on the GODOX ML100 BI?

Select Bluetooth Reset (RESET), then press the select dial briefly to perform a Bluetooth reset. After the reset is complete, it will automatically return to the main interface.


What happens when Bluetooth is turned On (ON) on the GODOX ML100 BI?

After Bluetooth is turned on, you can use the “Godox Light” app to connect to the light body.


What happens when Bluetooth is turned Off (OFF) on the GODOX ML100 BI?

After Bluetooth is turned off, the “Godox Light” app cannot connect to the light body.


What should I do if the GODOX ML100 BI shows a Low Battery Warning?

Please power the device with an external battery pack through DC port. When the battery level is below one green bar, the display screen will automatically show a low battery symbol.


What should I do if the GODOX ML100 BI shows a High Temperature Warning at the top of the display?

When the top of the display shows 🌡️, it indicates that the lamp bead temperature is too high. It is recommended to pause usage until the display screen no longer shows 🌡️, and then you can resume using the light.


What should I do if the GODOX ML100 BI shows a High Temperature Warning on the full screen?

When the full screen of the display shows 🌡️, it indicates that the light body temperature is too high. The light fixture will automatically activate the light-off function. Once the temperature of the light beads returns to normal, the light fixture will resume normal operation.


What is the photometric data for the GODOX ML100 BI bare light at 4300K CCT?

CCT Test Condition Unit 1m 2m 3m
4300K Bare Light lux ≈ 3520 ≈ 916 ≈ 427
fc ≈ 327 ≈ 85 ≈ 40

What is the photometric data for the GODOX ML100 BI with Lens Reflector ML-L15 at 4300K CCT?

CCT Test Condition Unit 1m 2m 3m
4300K Lens Reflector ML-L15 lux ≈ 32900 ≈ 8350 ≈ 3860
fc ≈ 3060 ≈ 776 ≈ 359

What is the photometric data for the GODOX ML100 BI with Lens Reflector ML-L36 at 4300K CCT?

CCT Test Condition Unit 1m 2m 3m
4300K Lens Reflector ML-L36 lux ≈ 17100 ≈ 4320 ≈ 1910
fc ≈ 1590 ≈ 401 ≈ 177

What is the photometric data for the GODOX ML100 BI bare light at 2800K CCT?

CCT Test Condition Unit 1m 2m 3m
2800K Bare Light lux ≈ 2580 ≈ 682 ≈ 316
fc ≈ 239 ≈ 63 ≈ 29

What is the photometric data for the GODOX ML100 BI with Lens Reflector ML-L15 at 2800K CCT?

CCT Test Condition Unit 1m 2m 3m
2800K Lens Reflector ML-L15 lux ≈ 24100 ≈ 6010 ≈ 2800
fc ≈ 2240 ≈ 558 ≈ 260

What is the photometric data for the GODOX ML100 BI with Lens Reflector ML-L36 at 2800K CCT?

CCT Test Condition Unit 1m 2m 3m
2800K Lens Reflector ML-L36 lux ≈ 12500 ≈ 3140 ≈ 1380
fc ≈ 1160 ≈ 292 ≈ 128

What is the photometric data for the GODOX ML100 BI bare light at 3200K CCT?

CCT Test Condition Unit 1m 2m 3m
3200K Bare Light lux ≈ 2990 ≈ 777 ≈ 363
fc ≈ 278 ≈ 72 ≈ 34

What is the photometric data for the GODOX ML100 BI with Lens Reflector ML-L15 at 3200K CCT?

CCT Test Condition Unit 1m 2m 3m
3200K Lens Reflector ML-L15 lux ≈ 27900 ≈ 7040 ≈ 3250
fc ≈ 2590 ≈ 654 ≈ 302

What is the photometric data for the GODOX ML100 BI with Lens Reflector ML-L36 at 3200K CCT?

CCT Test Condition Unit 1m 2m 3m
3200K Lens Reflector ML-L36 lux ≈ 14500 ≈ 3640 ≈ 1610
fc ≈ 1350 ≈ 338 ≈ 150

What is the photometric data for the GODOX ML100 BI bare light at 5600K CCT?

CCT Test Condition Unit 1m 2m 3m
5600K Bare Light lux ≈ 3670 ≈ 953 ≈ 446
fc ≈ 341 ≈ 89 ≈ 41

What is the photometric data for the GODOX ML100 BI with Lens Reflector ML-L15 at 5600K CCT?

CCT Test Condition Unit 1m 2m 3m
5600K Lens Reflector ML-L15 lux ≈ 34300 ≈ 8800 ≈ 4040
fc ≈ 3190 ≈ 817 ≈ 376

What is the photometric data for the GODOX ML100 BI with Lens Reflector ML-L36 at 5600K CCT?

CCT Test Condition Unit 1m 2m 3m
5600K Lens Reflector ML-L36 lux ≈ 17900 ≈ 4480 ≈ 1990
fc ≈ 1660 ≈ 416 ≈ 185

What is the photometric data for the GODOX ML100 BI bare light at 6500K CCT?

CCT Test Condition Unit 1m 2m 3m
6500K Bare Light lux ≈ 3380 ≈ 878 ≈ 410
fc ≈ 314 ≈ 82 ≈ 38

What is the photometric data for the GODOX ML100 BI with Lens Reflector ML-L15 at 6500K CCT?

CCT Test Condition Unit 1m 2m 3m
6500K Lens Reflector ML-L15 lux ≈ 31200 ≈ 8100 ≈ 3730
fc ≈ 2840 ≈ 752 ≈ 346

What is the photometric data for the GODOX ML100 BI with Lens Reflector ML-L36 at 6500K CCT?

CCT Test Condition Unit 1m 2m 3m
6500K Lens Reflector ML-L36 lux ≈ 16500 ≈ 4130 ≈ 1830
fc ≈ 1530 ≈ 383 ≈ 170

How can the GODOX ML100 BI be powered using DC Power Supply?

Connect the adapter to AC power, input 20V= 6A.


How can the GODOX ML100 BI be powered using USB-C Power Supply?

You can separately purchase a charging adapter or power bank, the output of which is determined by the charging adapter or power bank used.


How can the GODOX ML100 BI be powered using AK-B02 Power Supply?

You can separately purchase a V-mount battery accessory kit AK-B02 and one 14.8V V-mount battery.


How should I maintain the exterior of the GODOX ML100 BI?

To prevent dust buildup affecting performance, please clean the exterior of the device regularly using a soft, damp cloth.


What are the technical specifications for the GODOX ML100 BI?

Model GODOX ML100 BI
Power Supply 20V= 6A
Max. Input Power ≈120W
Brightness Range 0%-100%
CRI Average≥97
TLCI Average≥98
CCT 2800-6500K
FX Type 11
Bluetooth Control Distance Max.30m
Working Environment Temperature -10°C~+40°C
Dimension (Excluding lens reflector) 4.80″ x 4.33″ x 1.81″
Net Weight(Excluding lens reflector) 487g