What should I know about the replacement overlay for the GE BEH80DCEJSB control?
Service replacement controls must have a new overlay included with the control. Overlays have a one-time adhesive, and damage will occur if attempts are made to remove and re-use the old one. The Control Trim has changed design on some models, so a new control, overlay, and trim must be used.
Which control number corresponds to my GE BEH80DCEJSB water heater?
| Model Number | Control Number |
|---|---|
| GEH50DEEDSR* GEH50DFEJSR* GEH80DFEJSR* |
WS35X20581 (red) |
| GEH50DEEJSC* GEH80DEEJSC* |
WS35X20582 (gray) |
| GEH50DEEDSC* | WS35X20584 (gray) |
| BEH50DCEHSB*/ RE2H50R10-1NCWW BEH50DCEJSB*/ RE2H50R10B-1NCWT BEH80DCEJSB*/ RE2H80R10B-1NCWT |
WS35X20583 (black) |
* Denotes Engineering Digit
How do I remove the bezel to access the control housing on my GE BEH80DCEJSB?
Some models have a visible screw at the bottom of the control which allows removal of the control housing. All other models have a bezel which must be removed to access the screw securing the control housing to the water heater.
To remove the bezel, pull the right side to the right and outwards to release the mounting tabs.
The bottom mounting screw can now be removed to access the rear cover and wiring connections.
How do I install the new overlay on the GE BEH80DCEJSB control console?
Step 1. Place the control console on a firm, flat surface.
Step 2. Peel the protective paper backing from the back of the overlay. Use care not to touch the LED window to prevent fingerprints and sticking to the adhesive.
Step 3. Place the overlay against the right side lip of the control housing.
Step 4. Use the RJ45 and top / bottom lips to finish proper orientation of the overlay.
Step 5. Firmly press the overlay working from the center out to the edges.
How do I install the new control and bezel on my GE BEH80DCEJSB?
Step 1. Install the control board assembly.
Step 2. Connect all wiring.
Step 3. Re-mount the control assembly to the water heater.
Step 4. Re-install the mounting screw at the bottom of the control.
Step 5. Remove the protective film from the outside of the overlay.
Step 6. Install the new control bezel. The control trim is held in place with 10 tabs (3 each side, 2 on top and bottom). The trim has a top and bottom. When reinstalling the trim, if reversed, the tabs will not align. It is helpful to squeeze the sides of the trim slightly to guide the side tabs in place.
Step 7. Turn the power ON.
How do I set the Personality ID on a new control for my GE BEH80DCEJSB?
After installing the new control and turning the power ON:
1. The new control will blink “ooo” at the top of the display and beep 3 times.
2. Use the arrow keys on the user interface to scroll to the selected personality ID.
Which Personality ID should I select for my GE BEH80DCEJSB?
Use the below table to select the proper personality ID. The personality must be set correctly for the new service control to operate properly. For the GE BEH80DCEJSB with CCE Active, the initial ID is 83A. If a ducting kit is installed, the ID will be adjusted to 86A in a later step.
| Model | Personality ID |
|---|---|
| GEH50DEEDSR* | 50C |
| GEH50DEEDSC* | 50D |
| GEH50DFEJSR* (CCE Active) | 51A / 54A |
| GEH50DEEJSC* (CCE Active) | 52A / 55A |
| GEH80DFEJSR* (CCE Active) | 81A / 84A |
| GEH80DEEJSC* (CCE Active) | 82A / 85A |
| BEH50DCEHSB*/RE2H50R10-1NCWW | 50E |
| BEH50DCEJSB*/RE2H50R10B-1NCWT (CCE Active) | 53A / 56A |
| BEH80DCEJSB*/RE2H80R10B-1NCWT (CCE Active) | 83A / 86A |
Note: If the Model has a ducting kit installed use the smaller number in the chart below for initial setting. The ducted personality number will not display and cannot be programmed in this step. The Ducting Accessory adjustment is completed in Step 7.
How do I finalize the Personality ID setting on my GE BEH80DCEJSB?
Press and HOLD the ENTER button until a tone is heard.
Note: If a valid personality ID is not received the water heater will not function and the display will show a circle in the upper half of each of the three digits.
What should I do if I set the incorrect Personality ID on my GE BEH80DCEJSB?
1. Enter Service Mode.
2. Press the MODE button 3 times (until the previously selected personality displays on the screen).
3. Repeat the steps for setting the Personality ID.
4. Exit Service Mode.
Note: Service mode entry instructions may be found in the mini-manual, inside the front shroud to the right of the control module.
How do I perform the Duct Accessory Model Personality Adjustment on my GE BEH80DCEJSB?
Only activate the CCE setting if it was active before the control was serviced. The CCE setting does not need to be active on units with a ducting kit unless it qualifies for Northern Climate Tier 3 rebates or if the consumer wishes the setting to be active.
1. Press “DOWN Arrow (v)” and “FILTER” button for 5 seconds.
2. The screen will display “dUC or CCE”.
3. Personality will be adjusted to the larger ducted number as shown in the Personality ID table (e.g. from 83A to 86A for the BEH80DCEJSB).
4. To exit out of duct setting press “DOWN Arrow (v)” and “FILTER” button for 5 seconds, the screen will display “Std”.
How do I verify the operation of my GE BEH80DCEJSB after installing a new control?
Verify that the user interface is displaying an initial set-point of 120 °F and turns on.
How do I connect my GE BEH80DCEJSB to the smartphone app if it has a ConnectPlus Wi-Fi module?
If the serviced water heater has a ConnectPlus Wi-fi module, you will need to follow the directions to connect the GeoSpring to the smartphone app. For models listed in the left column in the below table, enter the model number in the right column into the smartphone GeoSpring app.
| Model Number on Rating Plate | Enter Model in Smartphone GeoSpring app |
|---|---|
| GEH50DEEDSRA | GEH50DEEDSRX |
| GEH50DEEDSRB | GEH50DEEDSRX |
| GEH50DEEDSCA | GEH50DEEDSCX |
| GEH50DEEDSCB | GEH50DEEDSCX |
| RE2H50R10-1NCWW | BEH50DCEHSBA |
| RE2H50R10B-1NCWT | BEH50DCEJSBA |
| RE2H80R10B-1NCWT | BEH80DCEJSBA |
For models GEH50DFEJSRA, GEH50DEEJSCA, GEH80DFEJSRA and GEH80DEEJSCA follow the activation instructions on the consumer’s smartphone GeoSpring app.
What are the control wiring connections for the GE BEH80DCEJSB?
The wire color key for models including the GE BEH80DCEJSB is as follows:
1 Purple: anode (not all models)
2 Brown: fan (not all models)
3 Red: L2 Route through CT201
4 Pink: L2
5 Purple: L1
6 Orange: upper element
7 Yellow Jumper
8 Brown: lower element
9 Pink: compressor capacitor (not all models)
10 Blue: compressor
11 Green: ground (not all models)
12 Grey: fan
13 Yellow: T5 sensor
14 White: T2 sensor, Red (T3a sensor), White (T3b sensor)
15 Blue: T4 sensor
16 White, Orange, Yellow, Blue and Red: EEV
17 Orange: Condensate Sensor
Notice: some models have a blue jumper wire, it is no longer used.
What does Fault Code FC on my GE BEH80DCEJSB indicate and what should I check?
Condition: The control checks to ensure the evaporator is free of frost. It continuously verifies that T3a sensor (evaporator inlet temperature) is greater than 20°F after 30 minutes of run time.
Check: Check T3a sensor mounting, wiring and resistance. Check Electronic Expansion Valve (EEV) operation. Check sealed system for refrigerant leak.
What does Fault Code Fd on my GE BEH80DCEJSB indicate and what should I check?
Condition: The control checks to ensure evaporator superheat is OK (controlled by EEV). It continuously verifies the temperature difference between T3a sensor (evap inlet temp) and T3b sensor (evap outlet temp) is greater than 5°F after 30 mins of run time. The control also verifies that T3a is greater than 10°F less than the T5 ambient sensor.
Check: Check that the filter is clean. Check T3a, T3b and T5 sensor mounting, wiring and resistance. Check Electronic Expansion Valve (EEV) operation. Check sealed system for refrigerant leak.
What does Fault Code FE on my GE BEH80DCEJSB indicate and what should I check?
Condition: The control checks to ensure the compressor discharge temperature never exceeds 240°F. It continuously verifies that T4 sensor (compressor outlet temperature) is less than 240°F every minute of run time.
Check: Check T4 sensor mounting, wiring and resistance. Check Electronic Expansion Valve (EEV) operation. Check sealed system for refrigerant leak.
What does Fault Code FF on my GE BEH80DCEJSB indicate and what should I check?
Condition: The control checks to ensure the EEV is operating properly and valve rotation is within range.
Check: Check Electronic Expansion Valve (EEV) operation. Check T3a and T3b sensors mounting, wiring and resistance. Check sealed system for refrigerant leak.
What does Fault Code FG on my GE BEH80DCEJSB indicate and what should I check?
Condition: The control checks to ensure Ambient temperature is within an acceptable range before starting the heat pump. Heat pump operating range is 35°F < [T5 ambient] < 120°F. If ambient temperature (as viewed by T5 sensor) is outside of this range, the unit will switch to Electric/Standard Mode for that heating cycle only. NO fault code is shown on the display.
Check: No failure is assumed, but this information is provided for completeness.
What does Fault Code FI* on my GE BEH80DCEJSB indicate and what should I check?
Condition: The control checks to ensure evaporator superheat is <20°F AND the EEV position is <450 after 30 minutes of run time. If outside these limits, this provides an early indication of a refrigerant leak.
Check: Check sealed system for refrigerant leak. Check T3a, T3b, T5 sensor mounting, wiring and resistance. Check Electronic Expansion Valve (EEV) operation.
What does Fault Code FJ on my GE BEH80DCEJSB indicate and what should I check?
Condition: The control checks to ensure that the AC current draw is <= 20.5A while the compressor and lower heating element are both enabled. If current draw is >20.5A, the compressor will be disabled.
Check: Check lower heating element rated wattage. Element wattage is stamped on the heating element terminal block. Correct wattage can be found on the water heater’s rating plate.
What does Fault Code FL on my GE BEH80DCEJSB indicate and what should I check?
Condition: The control checks to ensure that T3a and T3b evaporator inlet and outlet temperatures are within 2.5°F of the T5 ambient temperature 20 minutes after defrost begins.
Check: Check T3a, T3b, T5 sensor mounting, wiring and resistance. Check Electronic Expansion Valve (EEV) operation.
What does Fault Code F2 on my GE BEH80DCEJSB indicate and what should I check?
Condition: T2 tank temperature sensor failure. Just before the compressor starts, the control checks if T2 sensor is within the 30°F – 170°F temperature range.
Check: Check T2 sensor mounting, wiring and resistance. Use service mode to monitor T2 sensor temperature. The control assembly may have failed.
What does Fault Code F3 on my GE BEH80DCEJSB indicate and what should I check?
Condition: Compressor failure. Control energizes the compressor, but the current sensor detects no current flow.
Check: Check compressor run capacitor. Check compressor, overloads, relay and wiring. Use service mode to manually cycle the compressor on/off.
What does Fault Code F4 on my GE BEH80DCEJSB indicate and what should I check?
Condition: Fan Failure.
Check: Check fan and wiring.
What does Fault Code F5 on my GE BEH80DCEJSB indicate and what should I check?
Condition: T3a sensor (evap inlet temperature) failure. The control detects the thermistor output is at or nearly shorted or open circuit.
Check: Check T3a sensor mounting, wiring and resistance. Use service mode to monitor T3a sensor temperature. Control assembly may have failed.
What does Fault Code F6 on my GE BEH80DCEJSB indicate and what should I check?
Condition: T3b sensor (evap outlet temperature) failure. The control detects the thermistor output is at or nearly shorted or open circuit.
Check: Check T3b sensor mounting, wiring and resistance. Use service mode to monitor T3b sensor temperature. Control assembly may have failed.
What does Fault Code F7 on my GE BEH80DCEJSB indicate and what should I check?
Condition: T4 sensor (compressor outlet) failure. The control detects the thermistor output is at or nearly shorted or open circuit.
Check: Check T4 sensor mounting, wiring and resistance. Use service mode to monitor T4 sensor temperature. Control assembly may have failed.
What does Fault Code F8 on my GE BEH80DCEJSB indicate and what should I check?
Condition: T5 sensor (ambient temperature) failure. The control detects the thermistor output is at or nearly shorted or open circuit.
Check: Check T5 sensor mounting, wiring and resistance. Use service mode to monitor T5 sensor temperature. Control assembly may have failed.
What does Fault Code F9 on my GE BEH80DCEJSB indicate and what should I check?
Condition: Lower heating element failure. Control energizes lower element, but current sensor detects no current flow.
Check: Check lower heating element and wiring. Use service mode to cycle element and check current draw. Control assembly may have failed.
What does Fault Code F10 on my GE BEH80DCEJSB indicate and what should I check?
Condition: Upper heating element failure. Control energizes Upper element, but current sensor detects no current flow.
Check: Check Upper heating element and wiring. Use service mode to cycle element and check current draw. Control assembly may have failed.
What does Fault Code F11 on my GE BEH80DCEJSB indicate and what should I check?
Condition: Dry Tank fault. This test is run within the first 22 minutes after the unit has powered on. The tank temperature, T2, is read and verified it has not risen more than 5 deg F. If it has, this indicates there is not enough water in the tank for water heater operation. After 1 failed Dry Tank test, “F11” is displayed. After 5 failed tests, an audible alarm will sound.
Check: Check to ensure the tank is full of water. Check T2 sensor mounting, wiring and resistance. Use service mode to monitor T2 sensor temperature. Control assembly may have failed.
What does Fault Code bAd linE (F12) on my GE BEH80DCEJSB indicate and what should I check?
Condition: The voltage is too low at power-up. The control monitors the input line voltage 1 minute after power-up, and if the voltage is below 155V, the fault code will be displayed.
Check: Check electrical supply line connections. Voltage should measure either 208 VAC or 240 VAC, depending upon power supply. Badline counts stored in “F12” and can be monitored via the Control when placed in diagnostics mode.
What does Fault Code F13 on my GE BEH80DCEJSB indicate and what should I check?
Condition: Stuck Key fault. This indicates there is a button on the front panel that is stuck down. This button is inoperable. Other buttons work normally. If the button becomes free, the fault code will clear by itself.
Check: Check to see if all buttons are operable. Control assembly has failed.
What does Fault Code DirtyFilter (F14) on my GE BEH80DCEJSB indicate and what should I check?
Condition: Filter LED is on, and audible alarm is sounding. Filter is too dirty to enable proper function of unit.
Check: Check to ensure Filter is clean. Filter cleaning instructions are found in the owner’s manual. Repeated dirty filter alarms that do not resolve by cleaning the filter may be an indication of a fan failure.
What does Fault Code F15 on my GE BEH80DCEJSB indicate and what should I check?
Condition: DataFlash fault. The microcontroller has detected a problem in the DataFlash (permanent memory storage).
Check: Control assembly may have failed.
What does Fault Code F16* on my GE BEH80DCEJSB indicate and what should I check?
* on some models
Condition: Anode Depleted. Anode LED is on, and the audible alarm is sounding. The control has calculated that the anode rod has been mostly consumed, or the time in operation has exceeded the replacement timeline threshold.
Check: Replace anode rod with GE approved Anode Depletion anode rod.
What does Fault Code F17* on my GE BEH80DCEJSB indicate and what should I check?
* on some models
Condition: Anode Depletion miswire condition or shorted to ground. The control has detected that the anode circuit has a corrosion current signal <= 0.25mA.
Check: Check to ensure the tank is full of water. Check anode and (tank) anode wire connections on the board and at the anode rod. Check if either of the T2 wire connections is shorted to earth ground. Check if anode is shorted to tank.
What does Fault Code F18 on my GE BEH80DCEJSB indicate and what should I check?
Condition: Current transformer miswired. F3, F9, and F10 fault codes have all occurred during the same heating cycle.
Check: Check that red L2 wire is through the CT201 current transformer on the board. If it is, board needs to be replaced.
What does Fault Code F19 on my GE BEH80DCEJSB indicate and what should I check?
Condition: Low Line Voltage.
Check: Check incoming line voltage.
What does Fault Code F20 on my GE BEH80DCEJSB indicate and what should I check?
Condition: Condensate drain pan port blocked. Water heater will only operate in standard/electric mode until the drain port is cleared and the sensor is no longer in contact with water.
Check: Check main drain on condensate drain pan. Unblock if necessary. Check that the sensor is in the correct position in the drain pan, on the screw post near the main drain port.
What does Fault Code F21 on my GE BEH80DCEJSB indicate and what should I check?
Condition: Application Update Failure. A problem occurred while updating the control application.
Check: Cycle power and try to complete the update again. If problems persist, replace the control board.
What does Fault Code F22 on my GE BEH80DCEJSB indicate and what should I check?
Condition: Parametric Data Update Failure. A problem occurred while updating parametric data.
Check: Cycle power and try to complete the update again. If problems persist, replace the control board.
What does Fault Code F23 on my GE BEH80DCEJSB indicate and what should I check?
Condition: Micro A/D Failure. The control has detected a microcontroller input port has failed.
Check: The control needs to be replaced.