PDF Content Summary: We Power Your World! Owner’s Manual of Generator for GN130000EW Green-Power America, LLC Products Service Information Green-Power America LLC thanks you for choosing a Green-Power America LLC product. Please register your product within 10 days of purchase to ensure that you receive optimal service. Always keep copy of your original receipt. By registering your product, you are protected: 1. You have a record of the product purchase, 2. Customer Service can Better serve you on warranty related issues, 3. Green Power America will be able to contact you in the unlikely event that a product recall notification is necessary. You can register your product in one of two ways as follows: Option 1: Go to the Green Power America website at green-poweramerica.com/ service and follow the instructions to register online. Option 2: Fill out the form on the Warranty Card included in the box, and return via standard mail to Green Power America at 840 9th Street Suite H, Upland CA 91786. Please note that postage is required to mail the registration form back to Green Power America. If you still have any questions regarding the usage or operation of your generator after you have carefully read the manual, or if you have any quality issues during operation, please call our toll-free service number shown below: 888-834-4218 2 13000W Gasoline Generator Table of Contents Topic Page Warranty Policy 4 Specifications 7 Safety Guidelines 8 General Precautions 10 Battery 18 Assembly and Installation 19 Operation 22 Inspection, Cleaning, Maintenance and Storage 23 General Parts Listing 34 WARNING! READ AND UNDERSTAND ALL SAFETY PRECAUTIONS IN THIS MUANUAL BEFORE OPERATING. FAILURE TO COMPLY WITH I INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL INJURY, PROPERTY DAMAGE, AND/OR VOIDING OF YOUR WARRANTY. GREEN-POWER AMERICA, LLC (HEREINAFTER IN SHORT “GREEN-POWER” OR “GPA”) WILL NOT BE LIABLE FOR AND DAMAGE BECAUSE OF FAILURE TO FOLLOW THESE INSTRUCTIONS. 3 Owner’s Manual Green-Power America (GPA) Version 2020-1 1st Revise WARRANTY POLICY -- GENERATOR Green-Power America, LLC (GPA) Two(2)-YEAR LIMITED WARRANTY or One(1)-YEAR LIMITED WARRANTY Green-Power America, LLC (GPA) provides Two(2)-Year or One(1)-Year (GPD1500 and GN1750D) limited factory warranty once consumers buy the generator from GPA or any of GPA partners in the United Sates. 1, Warranty Qualifications Green-Power America, LLC (GPA) will register this warranty upon receipt of your Warranty Registration Card / Warranty Registration on Web and a copy of your sales receipt from one of GPA's retail locations as proof of purchase. GPA strongly recommend consumer keeps the purchasing receipt as a proof. Please submit your warranty registration and your proof of purchase within ten (10) days of the date of purchase. 2, Clarification of Two(2)-Year Limited Warranty or One(1)-Year Limited Warranty ✔ Two(2)-Year Limited Warranty: For household use, from the original date of purchase, the warranty is clocked and the parts and repairing labor will be free in the 1st year, and parts only will be free in the 2nd year. If the product is used for commercial or industrial purpose, including but not limited to be used in commercial or industrial site, rental and any other types of income earning, the original Two(2)-Year Warranty will be expired and becomes Ninety(90) days instead, the parts will be free during this period. ✔ One(1)-Year Limited Warranty (Apply to GPD1500, GN1750D): For household use only, from the original date of purchase, the warranty is clocked and the parts will be free in the 1st year. If the product is used for commercial or industrial purpose, including but not limited to be used in commercial or industrial site, rental and any other types of income earning, the original One(1)-Year Warranty will be expired and becomes Thirty(30) days instead, the parts will be free during this period. ✔ GPA will provide all parts for replacement in whole lifetime of the product, material cost and transportation cost will apply if it is beyond of warranty period or not covered by the warranty policy. 3, Repair/Replacement Warranty GPA warrants to the original purchaser that the mechanical and electrical components will be free of defects in material and workmanship for a period of the 1st year from the original date of purchase for Two(2)-Year Warranty items household use. Parts are always free during warranty period. Transportation charges for the unit repair or replacement under this warranty will be sole responsibility of the consumer. This warranty only applies to the original purchaser only and is not transferable. Contact GPA's Service Center and GPA will troubleshoot any issue via phone (Toll-Free: 888-834-4218) or e-mail (service@green-poweramerica.com ). If the issue is not fixed, GPA will, at its option, authorize evaluation, repair or replacement of the defective parts or components at a GPA Service Center. GPA will provide you with a case number 4 13000W Gasoline Generator for warranty service. Please keep it for future reference. Repairs or replacements without prior authorization, or at an unauthorized repair facility, will not be covered by this warranty. 4, Return Policy and Procedure ✔ Defective Return If the defective unit can not be repaired by the authorized repair center and the unit was within one (1) year, GPA will make a decision, on GPA sole options, either replace it with an equivalent or return it to GPA and consumer will get refund. The refund amount will be determined by the used time as below: - Within thirty (30) days from the original purchasing date, full amount will be refunded. - For Two(2)-Year Warranty items household use only, from thirty-one (31 days) but within one (1) year from the original purchasing date, the refund proportion will be determined by 100% minuses its actual using months divided by twelve (12). Formula: Refund Proportion = 100%-number of used month/12*100% ✔ Remorse Return If consumer wants to return due to consumer’s mind changing or any other non-quality reason, which is called Remorse Return, and the unit is in its original packing condition or consumer opened the original package but never fill the fuel and/or oil into the unit, and the unit could be repacked properly, within thirty (30) days from the original purchasing date, GPA will provide a Return Goods Authorization number (RGA #) to the retailer to accept the return for refund. Consumer will pay the return freight and 15% of the retail price (excluding tax) for re-stock fee. The consumer should contact the retailer with GPA’s RGA# and will get remaining amount refunded after the return is received by GPA. The return address will be noted by GPA when the RGA# is provided. Attention please: Do Not Return The Unit To The Place Of Purchase even unless the retailer / distributor has a certain agreement with GPA in written. All refund will be issued in terms of Credit Memo (CM) to the retailer/distributor, and the consumer will get refund from the original store. 5, Warranty Exclusions This warranty does not cover the following repairs and equipment: ✔ Normal Wear and Tear Products with mechanical and electrical components need periodic parts and service to perform well, including but not limited, filter elements, o-rings, spark plug, rubber mounts, etc. This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a whole. ✔ Installation, Use and Maintenance --This warranty will not apply to parts and/or any labor of installation. --This warranty will not apply to parts and/or any labor if the product is deemed to have been misused, neglected, involved in an accident, abused, loaded beyond the product's limits, modified, installed improperly or connected incorrectly to any electrical component. --Normal maintenance is not covered by this warranty and is not required to be performed at a facility or by a person authorized by GPA. * Except as otherwise stipulated in any of the following enclosed Emission Control System Warranties 5 Owner’s Manual (if applicable) for the Emission Control System: U.S. Environment Protection Agency (EPA), California Air Resources Board (CARB) and/or Environment Canada (EC). ✔ Other Exclusions This warranty excludes: –Cosmetic defects such as paint, decals, etc. –Accessory parts such as starting batteries, tools and storage covers. –Failures due to acts of God and other force majeure events which beyond the manufacturer's control. –Problems caused by parts that are not original Green-Power America (GPA) parts. When applicable, this warranty does not apply to products used for prime power in place of a utility. 6, Limits of Implied Warranty and Consequential Damage Green-Power America (GPA) disclaims any obligation to cover any loss of time, freight, or any incidental or consequential claim by anyone due to using this generator. THIS WARRANTY AND THE ATTACHED U.S. EPA, CARB and/or EC EMISSION CONTROL SYSTEM WARRANTIES (IF APPLICABLE) ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. A unit provided as a replacement will be subject to the warranty of the original unit. The length of the warranty governing the exchanged unit will remain calculated by reference to the purchase date of the original unit. This warranty gives you certain legal rights which may change from State to State. Your State may also have other rights you may be entitled to that are not listed within this warranty. Contact Information green-poweramerica.com Customer Service Mon – Fri 8:00 AM – 5:00 PM (EST) Toll Free: 1-888-834-4218 Service Email: service@green-poweramerica.com 6 13000W Gasoline Generator Specifications AC electrical 13000W Current Output 40 Running Watts 10,500 Starting Watts 13,000 Four 120V 20A NEMA 5-20

One 120V/240V 30A NEMA L14-30R One 120V/240V 50A NEMA 14-50 DC electrical Outlet

Outlet 12V@8.3A Gasoline engine Type 4-cycle OHV air-cooled recoil start Displacement 479cc Oil capacity 1.2 L EPA approved yes Fuel Type 87+ Capacity 6.6 gallons Running

7.5 Weight timehours(approx on 1/2 load

Approximate weight 204lbs 7 Owner’s Manual Safety Guidelines – Definitions This manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to PREVENT EQUIPMENT PROBLEMS. The following symbols help you recognize this information. Please read the manual and pay attention to these sections. Save These Important Safety Instructions! Read and understand all of these safety instructions. Be sure to retain them for future use. WARNING! WARNINGS INDICATE A CERTAINTY OR STRONG POSSIBILITY OF PERSONAL INJURY OR DEATH IF INSTRUCTIONS ARE NOT FOLLOWED. CAUTION: CAUTIONS INDICATE A POSSIBILITY OF EQUIPMENT DAMAGE IF INSTRUCTIONS ARE NOT FOLLOWED. NOTE: NOTES GIVE HELPFUL INFORMATION WARNING! IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT. WHEN USING AIR TOOLS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF PERSONAL INJURY 8 13000W Gasoline Generator General Precautions WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SEVERE INJURY OR DEATH. CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN ALSO RESULT IN DAMAGE TO THE TOOL AND/OR THE ITEM YOU ARE WORKING ON. DANGER CARBON MONOXIDE Using a generator indoors WILL KILL YOU IN MINUTES. Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. But even If you cannot smell the exhaust, you could be breathing CO. · NEVER use a generator inside homes, garages, crawlspaces, or other partly enclosed areas. Deadly levels of carbon monoxide can build up in these areas. Using a fan or opening windows and doors does NOT supply enough fresh air. · ONLY use a generator outdoors and far away from open windows, doors, and vents. These openings can pull in generator exhaust. Even when you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or battery-backup CO alarm in the home. If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY. See a doctor. You could have carbon monoxide poisoning. WARNING! THE EXHAUST CONTAINS POISONOUS CARBON MONOXIDE GAS THAT CAN CAUSE LOSS OF CONSCIOUSNESS AND MAY LEAD TO DEATH. Gasoline and Oil This product requires oil and fuel. Attempting to start the engine without oil will ruin the engine and void the warranty. Work in well ventilated area. Keep cigarettes, flames or sparks away from the work area or where gasoline is stored. WARNING! GASOLINE IS EXTREMELY FLAMMABLE AND IS EXPLOSIVE UNDER CERTAIN CONDITIONS. KEEP OUT OF REACH OF CHILDREN. • Gasoline fuel and fumes are flammable and potentially explosive. Use proper fuel storage and handling procedures. Always have multiple ABC class fire extinguishers nearby. • Keep the generator and surrounding area clean at all times. 9 Owner’s Manual General Precautions (cont’d) Gasoline and Oil (cont’d) • Fuel or oil spills must be cleaned up immediately. Dispose of fluids and cleaning materials as per any local, state, or federal codes and regulations. Store oily rags in a covered metal container. • Never store fuel or other flammable materials near the generator. • Do not smoke, or allow sparks, flames or other sources of ignition around the engine and fuel tank. Fuel vapors are explosive. • Keep grounded conductive objects, such as tools, away from exposed, live electrical parts and connections to avoid sparking or arcing. These events could ignite fumes or vapors. • Do not refill the fuel tank while the engine is running or while the engine is still hot. Do not operate the generator with known leaks in the fuel system. • Excessive buildup of unburned fuel gases in the exhaust system can create a potentially explosive condition. This buildup can occur after repeated failed start attempts, valve testing, or hot engine shutdown. If this occurs, open exhaust system drain plugs, if equipped, and allow the gases to dissipate before attempting to restart the generator. • Use only engine manufacturer recommended fuel and oil. Fuel: Oil: Fuel capacity is 6.6 US gallons (25 L). Use regular Oil capacity is 1.33 qt (1.2 L) unleaded gasoline with a minimum octane rating of 90. Hot Components WARNING! ENGINE AND EXHAUST SYSTEM PARTS BECOME VERY HOT AND REMAIN HOT FOR SOME TIME AFTER THE ENGINE IS RUN. WEAR INSULATED GLOVES OR WAIT UNTIL THE ENGINE AND EXHAUST SYSTEM HAVE COOLED BEFORE HANDLING THESE PARTS. Power Output This generator is not designed to power sensitive electronic equipment (including computers and medical devices) without the addition of an approved line conditioner, which is sold separately. CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT. GREEN-POWER LLC IS NOT RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LINE CONDITIONER. 10 13000W Gasoline Generator General Precautions (cont’d) Work Area • Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents. • Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Generators create sparks which may ignite the dust or fumes. • Keep bystanders, children, and visitors away while operating a generator. Provide barriers or shields as needed. Electrical Safety • Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs. • Grounding provides a low-resistance path to carry electricity away from the user in the event of an electrical malfunction. • Double insulated tools are equipped with a polarized plug where one blade is wider than the other. This plug fits in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install a polarized outlet. Do not change the plug in any way. Double insulation eliminates the need for the three-wire grounded power cord and grounded power supply system. • Avoid body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators. There is an increased risk of electric shock if your body is grounded. • Do not expose generator to rain or wet conditions. Water entering a generator will increase the risk of electric shock. • Do not abuse the power cord. Keep power cords away from heat, oil, sharp edges, or moving parts. Replace damaged power cords immediately. Damaged power cords increase the risk of electric shock. • When operating a power tool outside, use an outdoor extension cord marked “W-A” or “W”. These extension cords are rated for outdoor use, and reduce the risk of electric shock. 11 Owner’s Manual General Precautions (cont’d) Electrical Safety (cont’d) • All connections and conduits from the generator to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable. • The generator must be earth-grounded for fixed installations in accordance with all relevant electrical codes and standards before operation. • Do not attempt to connect or disconnect load connections while standing in water, or on wet or soggy ground. • Do not touch electrically energized parts of the generator and interconnecting cables or conductors with any part of the body, or with any non-insulated conductive object. • Connect the generator only to a load or electrical system (120 volt) that is compatible with the electrical characteristics and rated capacities of the generator. • Before servicing equipment powered by the generator, disconnect the equipment from its power input. • Keep all electrical equipment clean and dry. Replace any wiring where the insulation is cracked, cut abraded or otherwise degraded. Replace terminals that are worn, discolored, or corroded. Keep terminals clean and tight. • Insulate all connections and disconnected wires. • Guard against electric shock. Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures. Personal Safety • Stay alert. Watch what you are doing, and use common sense when operating a generator. Do not use generator while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating generators may result in serious personal injury. • Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts. 12 13000W Gasoline Generator General Precautions (cont’d) Personal Safety (cont’d) • Avoid accidental starting. Make sure the power switch is in its “OFF” position, and disconnect the spark plug wire when not in use. • Remove adjusting keys or wrenches before turning the generator on. A wrench or a key that is left attached to a rotating part of the generator may result in personal injury. • Do not overreach. Keep proper footing and balance at all times. • Use safety equipment. Always wear eye protection. Wear ANSI approved safety impact eye goggles. Dust mask, non-skid safety shoes, hard hat, or hearing protection must be used for appropriate conditions. • Do not force the generator. Use the correct generator for your application. The correct generator will do the job better and safer at the rate for which it is designed. • Do not use the generator if the power switch does not turn it on or off. Any generator that cannot be controlled with the power switch is dangerous and must be replaced. Generator Use and Care Make sure the power switch is in its “OFF” position and disconnect the spark plug wire before making any adjustment, changing accessories, or storing the generator. Such preventive safety measures reduce the risk of starting the generator accidentally. Store idle generators out of reach of children and other untrained persons. Generators are dangerous in the hands of untrained users. Maintain generators with care. Do not use damaged generator. Tag damaged generators “Do not use” until repaired. Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the generator’s operation. If damaged, have the generator serviced before using. Many accidents are caused by poorly maintained generators. Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one generator may become hazardous when used on another generator. 13 Owner’s Manual General Precautions (cont’d) Servicing Maintain labels and name plates on the generator and engine. These carry important information. If unreadable or missing, contact our service center toll free immediately for a replacement. Generator service must be performed only qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury. When servicing a generator, use only identical replacement parts. Follow all appropriate instructions in this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury. Heart Pacemakers WARNING! PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN(S) BEFORE USING THIS PRODUCT. ELECTROMAGNETIC FIELDS IN CLOSE PROXIMITY TO A HEART PACEMAKER COULD CAUSE INTERFERENCE TO OR FAILURE OF THE PACEMAKER. Installation • If a transfer switch is installed, ensure installation meets all applicable safety, and local and national electrical codes. Have installation performed by a qualified, licensed electrician and building contractor. • All electrical work, including the earth-ground connection, should be completed by a licensed electrician. • Any separate fuel storage or generator supply facility must be built or installed in full compliance with all relevant local, state, and federal regulations. 14 13000W Gasoline Generator General Precautions (cont’d) Installation (cont’d) • If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It should not be run outdoors without protection to the generator and wiring conduit. • The generator might weigh over 100 lbs. Two or more people should assist when moving or lifting this product. Never lift the generator using the engine or alternator lifting lugs. Connect lifting equipment to the frame of the generator. • Before lifting the generator, ensure the lift rigging and supporting structure are in good condition, and are rated to lift such a load. • Keep all personnel away from the suspended generator during relocating. • The supporting floor/ground surface should be level and strong enough to safely hold the weight of the generator. If the floor/grounded surface is not level, strong cross members should be placed under the full length of the generator frame at its low side. • For trailer installation, the generator should be mounted on the center point of the trailer, over the wheels. The trailer must be capable of supporting the weight of the generator and all contents (tools, etc.) • Install sound-and weather-proofing only when it is not raining or snowing to avoid trapping moisture within the generator’s area. Mechanical • Always make sure the power switch is in its “OFF” position. Disconnect the spark plug wire, and allow the engine to completely cool before carrying out maintenance. • Check for damaged parts. Before using the generator, any part that appears damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment and binding of moving parts, any broken parts or mounting fixtures, and any other condition that may affect proper operation technician. • The generator is designed with guards for protection from moving parts. In any case, care must still be taken to protect personnel and equipment from other mechanical hazards when working around the generator. 15 Owner’s Manual General Precautions (cont’d) Mechanical (cont’d) • Do not operate the generator with safety guards removed. While the generator is running, do not attempt to reach around the safety guard for maintenance or any other reason. • Keep hands, arms, long hair, loose clothing, and jewelry away from moving parts. Be aware that when engine parts are moving fast they cannot be seen clearly. • Keep access doors on enclosures closed and locked when access is not required. • When working on or around the generator always wear protective clothing including ANSI approved safety gloves, safety eye goggles, and safety hat. • Do not alter or adjust any part of the generator that is assembled and supplied by the manufacturer. • Always follow and complete scheduled engine and generator maintenance. Chemicals • Avoid contact with hot fuel, oil, exhaust fumes, and hot solid surfaces. • Avoid body contact with fuels, oils, and lubricants used in the generator. If swallowed, seek medical treatment immediately. Do not induce vomiting if fuel is swallowed. For skin contact, immediately wash with soap and water. For eye contact, immediately flush eyes with clean water and seek medical attention. Noise • Prolonged exposure to noise levels above 68 DBA is hazardous to hearing. Always wear ANSI approved ear protection when operating or working around the generator when it is running. 16 13000W Gasoline Generator General Precautions (cont’d) Extension Cord If an extension cord (not included) is used, make sure to use only UL approved cords having the correct gauge and length according to the following table: Nameplate Amps (@ full load) Cord Lengths 0 ft.- 50 ft. 50 ft.-100 ft. 100 ft.-150 ft. 150 ft.-200 ft. 0 - 5 16 AWG 16 AWG 12 AWG 12 AWG 5.1 - 8 16 AWG 14 AWG 10 AWG - 8.1 - 12 14 AWG 12 AWG - - 12.1 - 15 12 AWG 10 AWG - - 15 - 20 10 AWG 10 AWG - - 17 Owner’s Manual Battery the generator is equipped with electric start system, you need to install the battery properly, when you replace the battery,The regular battery should be with following specifications: Voltage 12V.lead-acid battery with 17AH, or 12V Li-battery with 1.6AH respectively. First, Connect the wires to the electrical motor positive electrode and battery positive electrode, electrical motor negative and battery negative electrode respectively. During connection, DO NOT touch battery’s positive electrode and negative electrode directly. Caution: Connecting or touching the Battery’s positive electrode and negative electrode directly may cause battery burning and cause damage to the equipment or even more serious accident! 18 13000W Gasoline Generator Assembly and Installation Unpacking 1. Remove the generator and loose parts box from the carton. 2. Compare the Hardware Kit included with the inventory list below. Loose Parts (Wheel kit) Check all loose parts against the following list. Contact your dealer toll free at 888.834.4218, if any of the parts listed below is/are not found. Hardware Check: Your Hardware Kit should include: 1) Two support with bolts and nuts 2) Two washers 3) Two axel shaft with pins 4) Two wheels INSTALLING FEET TO FRAME 1.Place generator on a flat surface; 2.Place a piece of cardboard or other soft material to tip the generator ,to protector the frame paint and prevent the generator from sliding.Tip the generator onto the side. 3.Install the support foot the frame using M8 flange bolts. INSTALL WHEELS TO FRAME 1.Insert axle to the frame,and install the pin to lock it in place. 2.Install the wheel through the axel,then install the gasket and pin o lock it in place. 3.Repeat previous steps on other wheel. 19 Owner’s Manual Installation NOTE: PRIOR TO POWERING TOOLS AND EQUIPMENT MAKE SURE THE GENERATOR’S RATED VOLTAGE, WATTAGE AND AMPERAGE CAPACITY IS ADEQUATE TO SUPPLY ALL ELECTRICAL LOADS THAT THE UNIT WILL POWER. IF POWERING EXCEEDS THE GENERATOR’S CAPACITY, IT MAY BE NECESSARY TO GROUP ONE OR MORE OF THE TOOLS AND/OR EQUIPMENT FOR CONNECTION TO A SEPARATE GENERATOR. Electrical and other permits may be required for the installation of emergency power systems. Investigate your local building and electrical codes before installing this unit. Installation must be completed by licensed contractors. WARNING! THE GENERATOR WEIGHS APPROXIMATELY OVER 100 POUNDS. USE CARE AND THE PROPER LIFTING OR HOISTING EQUIPMENT WHEN MOVING IT TO THE INSTALLATION LOCATION. ALWAYS CONNECT HOIST LINES TO THE FRAME OF THE GENERATOR. General Location • Make sure to locate and install the generator outdoors where cooling air is readily available. • Install the generator so that the air inlets and outlets are not blocked by obstructions such as bushes, trees, or snow drifts. Locating it in the path of heavy winds or snowdrifts may require the placement of a barrier for protection. In normal weather conditions, the air vent should face the prevailing wind direction. • Install the generator on a concrete slab or other area where rain drainage or flood waters can not reach it. • Generator placement should allow four feet of access to all sides for maintenance. • Place the generator as close as possible to the electrical tools and equipment being powered to reduce the length of extension cords. 20 13000W Gasoline Generator Installation (cont’d) Supporting and Mounting Mount the generator on a concrete slab capable of supporting the weight of the generator. The slab must extend on all sides beyond the frame by at least one foot. Contact a cement contractor for slab specifications if necessary. Attach the frame to the concrete slab using 3/8” diameter expansion anchor bolts (not supplied). Grounding NOTE: IT IS RECOMMENDED THAT ONLY A TRAINED AND LICENSED ELECTRICIAN PERFORM THIS PROCEDURE Connect a #6 AWG grounding wire (not included) from the ground connector (8) on the generator to a grounding rod (not included) that has been driven at least 24 inches deep into the earth. The grounding rod must be an earth-driven copper or brass rod (electrode) which can adequately ground the generator. Fuel tank Panel Air filter Wheel Support Product Image for Reference only 21 Owner’s Manual Operation NOTE: THE PARTS LISTED ABOVE ARE HELPFUL FOR LOCATING THE CONTROLS MENTIONED BELOW. Before Starting the Generator CAUTION: PRIOR TO FIRST USING THE GENERATOR, THE ENGINE MUST BE FILLED WITH HIGH QUALITY SAE 10W-30 GRADE ENGINE OIL. TO DO SO, UNSCREW AND REMOVE THE ENGINE’S OIL DIPSTICK LOCATED AT THE BOTTOM OF THE ENGINE CRANKCASE. FILL THE ENGINE CRANKCASE UNTIL THE OIL LEVEL IS LEVEL WITH THE UPPER MARKED LINE ON THE DIPSTICK. THEN SCREW THE DIPSTICK BACK INTO THE OIL FILL HOLE. 1. Check that the engine power switch is in its Fuel tank capacity: 25.0L (6.6 gallons) “OFF” position. 2. Before the first use, remove the fuel tank cap and fill the fuel tank with unleaded gasoline. When fueling, be sure that the fuel strainer is in place. Replace the fuel tank cap. Thereafter, check the engine’s fuel gauge for the amount of unleaded gasoline in the fuel tank. If necessary, refill the fuel tank with unleaded gasoline; the generator must be turned off and cooled down before refilling the fuel tank. Use gasoline with a pump octane rating of 90 or higher. We recommend unleaded gasoline because it produces fewer engine and spark plug deposits and extends exhaust system life. Never use stale or contaminated gasoline or oil/gasoline mixture. Avoid getting dirt or water in the fuel tank. 22 13000W Gasoline Generator Operation (cont’d) Starting 1. Turn the engine switch to the ON position. The engine switch enables and disables the ignition system. OFF: To stop the engine ON: To run the engine 2. The fuel valve is located under the fuel tank. When the valve lever is in the ON position, fuel is allowed to flow from the fuel tank to the carburetor. Be sure to return the fuel valve lever to the OFF position after stopping the engine 3. To start a cold engine, move the choke lever to the CLOSED position. To restart a warm engine, leave the choke lever in the OPEN position. The choke lever opens and closes the choke valve in the carburetor. The CLOSED position enriches the fuel mixture from starting a cold engine. The OPEN position provides the correct fuel mixture for operation after starting, and for restarting a warm engine. 23 Owner’s Manual Operation (cont’d) Starting 4. Recoil Starter: Pull the starter grip lightly until you feel resistance, then pull briskly. Return the starter grip gently. Pulling the starter grip operates the recoil starter to crank the engine. Electric start: Push and hold the engine switch on the “START” position for 3~5s and crank the engine. 5. If the choke has been moved to the CLOSED position to start the engine, gradually move it to the OPEN position as the engine warms up. Stopping Engine 1. Turn the engine switch to the OFF position. 2. Turn the fuel valve lever to the OFF position. When the engine is not in use, leave the fuel valve in the OFF position to prevent carburetor flooding and to reduce the possibility of fuel leakage. 24 13000W Gasoline Generator Operation (cont’d) Powering 120/240 Volt AC Tools And Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage capacity is adequate to supply all electrical loads that the unit will power.total demanding power the generator's capacity,it is necessary to remove one or more of the tools and/or equipment to another generator. CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT,such as laptops WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT.GREEN-POWER LLC IS NOT RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LINE CONDITIONER. 2. Once the generator is running, simply connect the power cords of 120/240volt AC powered tools and equipment into the 120/240volt AC dual outlets. NOTE: THE GENERATOR FEATURES AN AC NON-FUSE THERMAL PROTECTOR TO PROTECT THE AC CIRCUIT IN CASE OF AN OVERLOAD. SHOULD AN OVERLOAD OCCUR, THE BREAKER WILL POP. 3. Disconnect all electrical powered tools and equipment from the generator’s 120/240volt AC duel outlets. 4. After the engine and generator have completely cooled, store generator in a safe, clean, dry location (if not already installed). 25 Owner’s Manual Operation (cont’d) Powering 12 Volt DC tools and Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage capacity (12V DC) is adequate to supply all electrical loads that the unit will power. If powering exceeds the generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator. 2. Connect the power cord of a 12 VDC powered tool or equipment to the DC Terminals. CAUTION: MAKE SURE TO CONNECT THE POSITIVE (+) LEAD OF THE POWER CORD TO THE POSITIVE (+) TERMINAL ON THE GENERATOR, AND CONNECT THE NEGATIVE (-) LEAD OF THE POWER CORD TO THE NEGATIVE (-) TERMINAL ON THE GENERATOR. THE 12V DC IS FOR BATTERY CHARGING ONLY. 26 13000W Gasoline Generator Inspection, Cleaning, and Maintenance WARNING! ALWAYS MAKE SURE THE ENGINE POWER SWITCH IS IN ITS “OFF” POSITION. DISCONNECT THE SPARK PLUG WIRE FROM THE ENGINE. AND ALLOW SUFFICIENT TIME FOR THE ENGINE AND GENERATOR TO COMPLETELY COOL BEFORE PERFORMING ANY INSPECTIONS, MAINTENANCE, OR CLEANING. Spark Plug Maintenance In order to service the spark plug, you will need a spark plug wrench (commercially available). Recommended spark plugs TORCH F6RTC but we recommend our OEM spark: plug. To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. 1. Remove the spark plug cap. 2. Clean any dirt from around the spark plug base. 3. Use a spark plug wrench to remove the spark plug. 4. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark plug with a wire brush if it is to be reused. 5. Measure the plug gap with a feeler gauge. (Correct as necessary by carefully bending the side electrode.) The gap should be: 0.70-0.80 mm (0.028-0.031in) 6. Check that the spark plug washer is in good condition. 7. After the spark plug is seated, tighten with a spark plug in by hand to prevent cross-threading. 8. After the spark plug is seated, tighten with a spark plug wrench to compress the washer NOTE: THE SPARK PLUG MUST BE SECURELY TIGHTENED. AN IMPROPERLY TIGHTENED SPARK PLUG CAN BECOME VERY HOT AND COULD DAMAGE THE ENGINE. NEVER USE SPARK PLUGS WHICH HAVE AN IMPROPER HEAT RANGE. USE ONLY RECOMMENDED SPARK PLUS OR EQUIVALENT. 27 Owner’s Manual Maintenance Guide Periodic maintenance and adjustment is necessary to keep the generator in good operating condition. WARNING! Exhaust gas contains poisonous carbon monoxide. Shut off the engine before performing any maintenance. If the engine must be run, make sure the areas is well ventilated.

Item Routine Pre operation check Spark plug • Check condition. 6 months or 100 Hr Every 12 months or 300 Hr

• Clean and replace if necessary. ○ Fuel • Check fuel level and leakage. ○ Fuel hose • Check fuel hose for cracks or damage. ○ Replace if necessary. Engine oil • Check oil level in engine. ○ • Replace. ○(*1)

Air filter element • Check condition. • Clean. ○(*2)

Fuel tank filter • Clean and replace if necessary. ○ Fuel strainer • Clean and replace if necessary. ○ *1 ...Initial replacement of the engine oil is after one month or 20 hours of operation. *2... The air filter element needs to be cleaned more frequently when using in unusually wet or dusty areas. 28 13000W Gasoline Generator Air cleaner Maintenance A dirty air cleaner will restrict air flow to the carburetor. Lower generator output power and deteriorate the engine emission to prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. WARNING! Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion. Use only soapy water or nonflammable solvent. NOTE: Never run the generator without the air cleaner. Rapid engine wear will result. 1. Unsnap the air cleaner cover clips, remove the air cleaner cover, and remove the element. 2. Wash the element in a solution of household detergent and warm water, then rinse thoroughly, or wash in nonflammable or high flash point solvent. Allow the element to dry thoroughly. 3. Soak the element in clean engine of and squeeze out the excess oil. The engine will smoke during initial start-up if too much oil is left in the element. 4. Reinstall the air cleaner element and the cover. 29 Owner’s Manual Transporting/Storage When transporting the generator, turn the engine switch and the fuel valve OFF. Keep the generator level to prevent fuel spillage. Fuel vapor or spilled fuel may ignite. WARNING! Contact with a hot engine or exhaust system can cause serious burns or fires. Let the engine cool before transporting or storing the generator. Take care not to drop or strike the generator when transporting. Do not place heavy objects on the generator. Before storing the unit for an extended period: 1. Be sure the storage area is free of excessive humidity and dust. 2. Service according to the table below: STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline conditioner*. Fill with fresh gasoline and add gasoline conditioner*.

2 months to 1 year 1 year or more Drain the carburetor float bowl. Drain the fuel sediment cup. Fill with fresh gasoline and add gasoline conditioner*. Drain the carburetor float bowl. Drain the fuel sediment cup. Remove the spark plug. Put a tablespoon of engine oil into the cylinder. Turn the engine slowly with the pull rope to distribute the oil. Reinstall the spark plug. Change the engine oil. After removal from storage, drain the stored gasoline into a suitable container, and fill with fresh gasoline before starting.

30 13000W Gasoline Generator Transporting/Storage 1. Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container. Gasoline is extremely flammable and is explosive under certain condition Perform this task in a well ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area during this procedure. 2. Change the engine oil. 3. Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, then reinstall the spark plug. 4. Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed. Storing the engine in this position will help to protect it from internal corrosion. 31

Owner’s Manual Wiring Diagram 32

13000W Gasoline Generator Cylinder head system assy. A GPA Parts No Factory Parts No Description QTY GN13000EW-A-01 PGS40003 SCREW (M6*12) 4 GN13000EW-A-02 PGHD0650 VALVE COVER 1 GN13000EW-A-03 PGHD0675 GASKET, VALVE COVER 1 GN13000EW-A-04 PGH60050 SCREW (M10*80mm), CYLINDER HEAD 4 GN13000EW-A-05 PGH44726 SPARK PLUG 1 GN13000EW-A-06 PGHD0027 CYLINDER HEAD 1 GN13000EW-A-07 PGH64175 STUD BOLT(M8X108),CARBURETOR 2 GN13000EW-A-08 PGH62951 STUD BOLT(M8X39), MUFFER 2 GN13000EW-A-09 PGS60007 WASHER-LOCK (φ8) 2 GN13000EW-A-10 PGS10005 NUT, (M8) 2 GN13000EW-A-11 PGHF0075 GASKET, CYLINDER HEAD 1 GN13000EW-A-12 PGH61025 DOWEL PIN (φ12*20), CYLINDER HEAD 2 GN13000EW-A-13 PGH60778 BREATHER HOSE 1 33 Owner’s Manual Cylinder barrel B GPA Parts No Factory Parts No Description QTY GN13000EW-B-01 PGS40006 SCREW (M6X16) 2 GN13000EW-B-02 PGH64750 OIL LEVEL SWITCH ASSY 1 GN13000EW-B-03 PGS20004 NUT (M10) 1 GN13000EW-B-04 PGS40003 SCREW (M6X12) 1 GN13000EW-B-05 PGHF0900 CRANKCASE 1 GN13000EW-B-06 PGH62177 BEARING(6207) 1 GN13000EW-B-07 PGH65675 WASHER, GOVERNOR ROD 1 GN13000EW-B-08 PGH65625 PIN COTTER(10mm) 1 GN13000EW-B-09 PGH65650 GOVERNOR ROD 1 GN13000EW-B-10 PGH65600 OIL SEAL, GOVERNOR ROD 1 GN13000EW-B-11 PGH60951 FLAT WASHER, OIL DRAIN BOLT 2 GN13000EW-B-12 PGH60975 OIL DRAIN BOLT 2 GN13000EW-B-13 PGH60926 VITON OIL SEAL 1 GN13000EW-B-14 PGH44775 OIL SENSOR 1 GN13000EW-B-15 PGH62203 BEARING(6202) 1 34 13000W Gasoline Generator Crankcase cover system assy. C GPA Parts No Factory Parts No Description QTY GN13000EW-C-01 PGH66876 SCREW, CRANKCASE COVER 10 GN13000EW-C-02 PGH60926 VITON OIL SEAL 1 GN13000EW-C-03 PGHD6860 CRANKCASE COVER 1 GN13000EW-C-04 PGH66903 SHORT DIPSTICK 1 GN13000EW-C-05 PGH62203 BEARING(6202) 1 GN13000EW-C-06 PGH61000 DOWEL PIN(8X14), CRANKCASE COVER 2 GN13000EW-C-07 PGHD6925 GASKET, CRANKCASE COVER 1 GN13000EW-C-08 PGH62177 BEARING(6207) 1 GN13000EW-C-09 PGH75675 WASHER, GOVERNOR ROD 1 GN13000EW-C-10 PGHD5125 GOVENOR GEAR 1 GN13000EW-C-11 PGH65200 SLIDER SHAFT, GOVENOR GEAR 1 GN13000EW-C-12 PGH65150 GOVERNOR SPOOL 1 35 Owner’s Manual Crankshaft system assy. D GPA Parts No Factory Parts No Description QTY GN13000EW-D-01 PGHD2100 CRANKSHAFT 1 GN13000EW-D-02 PGHD1950 BALANCE SHAFT 1 36 13000W Gasoline Generator Piston & Connecting Rod Assy. E GPA Parts No Factory Parts No Description QTY GN13000EW-E-01 PGHD1350 COMPRESSION RING A 1 GN13000EW-E-02 PGHD1375 COMPRESSION RING B 1 GN13000EW-E-03 PGHD1400.1 OIL RING A 1 GN13000EW-E-04 PGHD1400.2 OIL RING B 2 GN13000EW-E-05 PGHF1300 CLIP, PISTON PIN 2 GN13000EW-E-06 PGHF1250 PISTON 1 GN13000EW-E-07 PGHF1275 PIN, PISTON 1 GN13000EW-E-08 PGHD1500.1 CONNECTING ROD BODY 1 GN13000EW-E-09 PGHD1500.2 CONNECTING ROD CAP 1 GN13000EW-E-10 PGHD1500.3 SCREW, CONNECTING ROD 2 37 Owner’s Manual Valve Train Assembly F GPA Parts No Factory Parts No Description QTY GN13000EW-F-01 PGHD0515 ROCKER ARM , EXHAUST VALVE 1 GN13000EW-F-02 PGHD0500 ROCKER ARM ,INTAKE VALVE 1 GN13000EW-F-03 PGHD0500.1 ADJUSTING SCREW, ROCKER ARM 2 GN13000EW-F-04 PGHD0500.2 ADJUSTING NUT, ROCKER ARM 2 GN13000EW-F-05 PGHD0475 PIN, ROCKER ARM 2 GN13000EW-F-06 PGH40150 VALVE SPRING RETAINER 2 GN13000EW-F-07 PGHD0100 VALVE SPRING 2 GN13000EW-F-08 PGHD0225 EXHAUST VALVE 1 GN13000EW-F-09 PGHD0125 INTAKE VALVE 1 GN13000EW-F-10 PGHD0351 PUSH ROD 2 GN13000EW-F-11 PGH60325 TAPPET 2 GN13000EW-F-12 PGHD1900 CAMSHAFT 1 38 13000W Gasoline Generator Recoil Starter Assy. G GPA Parts No Factory Parts No Description QTY GN13000EW-G-01 PGHD6100 BLOWER HOUSING 1 GN13000EW-G-02 PGS40003 SCREW (M6*12mm) 5 GN13000EW-G-03 PGHD6106 RECOIL 1 GN13000EW-G-04 PGS40019 SCREW (M6x8) 3 GN13000EW-G-05 PGH60774 ROUTING CLAMP 1 39 Owner’s Manual Carburetor Assy. I GPA Parts No Factory Parts No Description QTY GN13000EW-I-01 PGHF4050 CARBURETOR ASSY 1 GN13000EW-I-02 PGH64127 GASKET,CARBURETOR ASSY 1 GN13000EW-I-03 PGH64150 CARBURETOR SPACER 1 GN13000EW-I-04 PGHD4150 GASKET,CARBURETOR SPACER 1 40 13000W Gasoline Generator Flywheel Assy. J GPA Parts No Factory Parts No Description QTY GN13000EW-J-01 PGH44800 CHARGING COIL 1 GN13000EW-J-02 PGH66225 WIRE ROUTING RUBBER GROMET 1 GN13000EW-J-03 PGS40009 SCREW ( M6*25 ) 2 GN13000EW-J-04 PGH64826 RETAINER, CHARGING COIL 1 GN13000EW-J-05 PGS40000 SCREW ( M6*10 ) 1 GN13000EW-J-06 PGH62452 FLYWHEEL 1 GN13000EW-J-07 PGH42300 FLYWHEEL KEY 1 GN13000EW-J-08 PGH62500 COOLING FAN 1 GN13000EW-J-09 PGHD6125 STARTER CUP 1 GN13000EW-J-10 PGH62475 NUT, FLYWHEEL 1 41 Owner’s Manual Ignition System Assy. K GPA Parts No Factory Parts No Description QTY GN13000EW-K-01 BGH94675.2-1 SPARK PLUG BOOT 1 GN13000EW-K-02 BGH94675.2-2 IGNITION COIL ASSY 1 GN13000EW-K-03 BGH94675.2-3 WIRE HARNESS, STOP SWITCH 1 GN13000EW-K-04 PGS40009 SCREW (M6x25) 2 42 13000W Gasoline Generator Starter Motor Assy. L GPA Parts No Factory Parts No Description QTY GN13000EW-L-01 PGH64850 STARTER MOTOR 1 GN13000EW-L-02 PGH64950 RELAY,STARTER MOTOR 1 GN13000EW-L-03 PGH56875 SCREW (M8x35) 2 43 Owner’s Manual Control Assy. M GPA Parts No Factory Parts No Description QTY GN13000EW-M-01 PGHD5086 THROTTLE CONTROL ASSY 1 GN13000EW-M-02 PGHD5086.1 GOVERNOR BASE 1 GN13000EW-M-03 PGHD5086.2 ADJUSTING SPRING 1 GN13000EW-M-04 PGHD5086.3 SCREW 1 GN13000EW-M-05 PGS40006 SCREW (M6X16) 1 GN13000EW-M-06 PGHD5150 RETURN SPRING 1 GN13000EW-M-07 PGH65525 GOVERNOR SPRING 1 GN13000EW-M-08 PGH65450 LINKAGE 1 GN13000EW-M-09 PGS20000 NUT (M6) 1 GN13000EW-M-10 PGH45475 SCREW,GOVERNOR ARM 1 GN13000EW-M-11 PGHD5077 GOVERNOR ARM 1 44 13000W Gasoline Generator Air Cleaner N GPA Parts No Factory Parts No Description QTY GN13000EW-N-01 PGH62609 AIR FILTER ASSY 1 GN13000EW-N-02 PGH62609.1 PLASTIC COVER,AIR FILTER 1 GN13000EW-N-03 PGH62609.2 AIR FILTER ELEMENT 1 GN13000EW-N-04 PGH62609.3 FARDAGE, AIR FILTER 2 GN13000EW-N-05 PGH62609.4 SEALING RING, AIR FILTER 1 GN13000EW-N-06 PGH62609.5 BACKPLATE,AIR FILTER 1 GN13000EW-N-07 PGH62625 BRACKET, AIR FILTER 1 45 Owner’s Manual Muffler System Assy. O GPA Parts No Factory Parts No Description QTY GN13000EW-O-01 BGH30007 MUFFLER STAY COMP 1 GN13000EW-O-02 BGH92902 EXHASUT GASKET 1 GN13000EW-O-03 BGS10004 FLANGE NUT M8 2 GN13000EW-O-04 BGS60004 SPRING WASHER ¢8 2 46 13000W Gasoline Generator Fuel tank system assy. P GPA Parts No. Factory Parts No. Description Qty. GN13000EW-P-01 BGG21006.1 FUEL FILLER CAP COMP. 1 GN13000EW-P-02 BGG21523.1 FUEL FILLER 1 GN13000EW-P-03 BGG21523 FUEL TANK COMP. 1 GN13000EW-P-04 BGH64225 OVERFLOW VALVE 1 GN13000EW-P-05-1 BGH63693 VAPOR HOSE 1 GN13000EW-P-05-2 BGH63692 VAPOR HOSE 1 GN13000EW-P-06 BGH43582 TUBE CLIP A 4 GN13000EW-P-07 BGH60604 FUEL TUBE D 1 GN13000EW-P-08 BGH43625 FUEL VALVE 1 GN13000EW-P-09 PGH63575 FUEL CLIP C 2 GN13000EW-P-10 BGS40009 FLANGE BOLT (M6×25) 4 GN13000EW-P-11 BGH21519.2 RUBBER 4 GN13000EW-P-12 BGG20503 WASHER 4 GN13000EW-P-13 BGG21003 OIL GAUGE 1 GN13000EW-P-14 BGH70036 CROSS SCREW (M4×12) 2 47

Control panel assy. 2 Owner’s Manual 8 5 6 49 574

Q 1 9 3 10 GPA Parts No. Factory Parts No. Description Qty. GN13000EW-Q-01 BGG53203 ENGINE SWITCH ASSY 1 GN13000EW-Q-02 BGG52950 HOURMETER 1 GN13000EW-Q-03 BGG50705 EARTH TERMINAL 1 GN13000EW-Q-04 BGG52904 38A AC CIRCUIT PROTECTOR 4 GN13000EW-Q-05 BGG53350 120V 20A NEMA5-20 RECEPTACLE 4 GN13000EW-Q-06 BGG53400 120/240V 30A NEMAL 14-30 RECEPTACLE 1 GN13000EW-Q-07 BGG60027 120/240V 50A NEMAL 14-50R RECEPTACLE 1 GN13000EW-Q-08 BGG52905 40A AC CIRCUIT PROTECTOR 2 GN12000DEW-Q-09 BBGG52100 DC CIRCUIT PROTECTOR 4 GN130000DEW-Q-10 BBGG53650 D DC SOCKET 2 48 13000W Gasoline Generator Equipment Parts excluded in LCT Engine Frame Comp Assy. R GPA Parts No. Factory Parts No. Description Qty. GN13000EW-R-01 BGG41119 Frame 1 GN13000EW-R-02 BGG42117 Frame Handle 1 GN13000EW-R-03 BGG61051 HANDLE RUBER PAD 1 GN13000EW-R-04 BGG61050 RUBBER DECORATIVE PLATE 1 GN13000EW-R-05 BGS40006 FLANGE BOLT M6X16 12 GN13000EW-R-06 BGS40066 FLANGE BOLT M6X20 2 GN13000EW-R-07 BGG22001 FUEL TANK TRIM PANEL 1 GN13000EW-R-08 BGG50131 PANEL 1 GN13000EW-R-09 BGS30009 FLANGE BOLT M8X25 2 GN13000EW-R-10 BGS20004 Nut M8 4 GN13000EW-R-11 BGS40032 HANDLE RUBBER PLUG 2 GN13000EW-R-12 BGG61008 BOTTOM RUBBER B 2 GN13000EW-R-13 BGS20006 LOCKET M10 4 GN13000EW-R-14 BGS40032 FLANGE BOLT M10X40 4 GN13000EW-R-15 BGG61007 BOTTOM RUBBER A 2 GN13000EW-R-16 BGG42166 17Ah BATTERY LAYLER 1 GN13000EW-R-17 BGG60504 1.6Ah BATTERY 1 GN13000EW-R-18 BGG42173 1.6Ah BATTERY LAYLER 1 49 Owner’s Manual Generator S Generator GPA Parts No. Factory Parts No. Description Qty. GN13000EW-S-01 BGG12879.1 STATOR COVER 1 GN13000EW-S-02 BGG12879.2 STATOR ASSY 1 GN13000EW-S-03 BGG12879.3 COOLING FAN 1 GN13000EW-S-04 BGG13101 BRUSH ASSY 1 GN13000EW-S-05 BGS40078 TAPPING SCREW 8 GN13000EW-S-06 BGG13303 RR HOUSING 1 GN13000EW-S-07 BGS60000 SPRING WASHER (5mm) 4 GN13000EW-S-08 BGS14038 FLANGE BOLT (M6×197) 4 GN13000EW-S-09 BGG12503 AUTO VOLTAGE REG. ASSY 1 GN13000EW-S-10 BGG13007 GENERATOR COVER 1 GN13000EW-S-11 BGS40078 FLANGE BOLT (M6×12) 4 GN13000EW-S-12 BGS40078 FLANGE BOLT (M6×12) 2 GN13000EW-S-13 BGG12879.4 ROTOR COMP 1 GN13000EW-S-13 BGG12879.4 ROTOR COMP 1 GN13000EW-S-14 BGG12879.5 BEARING ASSY 1 GN13000EW-S-15 BGS60008 PLAIN WASHER 1 50 13000W Gasoline Generator GPA Parts No. Factory Parts No. Description Qty. GN13000EW-S-16 BGG14029 FLANGE BOLT (M10×275) 1 GN13000EW-S-17 BGG14037 FLANGE BOLT (M5×230) 1 GN13000EW-S-18 BGG30039 HEX. BOLT (M5×20) 1 GN13000EW-S-19 BGG13101 VOLT CHANGE TERMINAL BR-AC-W 1 GN13000EW-S-20 BGS50001 PLAIN WASHER (5mm) 1 51 Owner’s Manual Wheel & Hand Assy. GPA Parts No. Factory Parts No. Description Qty. GN13000EW-T-01 BGG60648 WHEEL 2 GN13000EWT-02 BGG42007 SHAFT 2 GN13000EWT-03 BGS20006.1.2 WASHER PLAIN 2 GN13000EWT-04 BGS61001 COTTER PIN 4 GN13000EWT-05 BGS61008 PIN(φ8*45) 2 GN13000EWT-06 BGG42114 HANDLE 2 GN13000EWT-07 BGS61007 R PIN(2.5*φ16) 2 GN13000EWT-08 BGS30009 FLANGE BOLT (M8×25) 2 GN13000EWT-09 BGG61005 RUBBER 2 GN13000EWT-10 BGS20002 FLANGE NUT M8 6 GN13000EWT-11 BGG42059 SUPPORT 1 GN13000EWT-12 BGS30007 BOLT M8*16 4 52 Distributed by: Green-Power America, LLC Green-PowerAmerica.com All copyright © is reserved by Green-Power America, LLC 53