How should I operate the FAKIR VIGOR PLUS when I first start using it?
Please open windows for air ventilation before plugging in the FAKIR VIGOR PLUS. Strive to maintain an environment of fresh indoor air.
After plugging in, the unit sensor will retain a memory of the existing indoor air condition, which will be input as “Clean Air”. Once started, the odor indicator will blink as it memorizes the existing fresh air condition. After two minutes, the indicator will die off to indicate an end of memorization. Whenever the unit is unplugged, all memorized content will be erased.
If the FAKIR VIGOR PLUS is turned on two minutes after plugging in, the odor sensor indicator will not blink.
When smoke, make up or spray that contains alcohol is present, please ventilate and freshen the air before closing Windows.
The FAKIR VIGOR PLUS will not be able to operate effectively if it is plugged while indoor air is polluted.
Sometimes the sensor is not as sensitive when first purchased or after being unplugged for over a week. Its sensitivity will recover after one or two days of operation.
What is the correct placement for the FAKIR VIGOR PLUS?
Place the FAKIR VIGOR PLUS at least with a distance of 30 cm to the wall and where children cannot touch within a short range of distance.
To prevent interference and distortion, the FAKIR VIGOR PLUS should be at least 1 meter away from computer, television or radio.
How do I start the FAKIR VIGOR PLUS?
Plug the FAKIR VIGOR PLUS into a proper socket. Press the POWER ON/OFF button. The device starts operating as the negative ion UV indicator is on. Press POWER ON/OFF again and the device will stop working.
How can I change the ventilation stages on the FAKIR VIGOR PLUS?
The FAKIR VIGOR PLUS has four different ventilation stages and the stage for automatic operation. Please select a stage appropriate for the room size and climate. By repeatedly pressing the “FLOW” button, the ventilation stage setting is changed.
The LED diodes indicate the stages in the following sequence: Quiet > Low > Med > Hi > AUTO > Quiet
How do I set the FAKIR VIGOR PLUS to automatic operation?
Press the “FLOW” button until the LED diode indicates “AUTO”. The device will now operate in automatic mode.
In automatic mode, the device independently switches to the appropriate operating speeds (MED or LOW), depending on odors, dust, or irritants detected in the room air by the sensor. As the air is purified, the device will automatically switch back to LOW or QUIET modes.
How can I set the operating time using the TIMER function on the FAKIR VIGOR PLUS?
Press the TIMER button repeatedly to set the desired operating time. The LED diodes indicate the following times: 1 Hour > 2 Hour > 8 Hour > 1 Hour …
How do I turn the Ion-UV feature on or off for the FAKIR VIGOR PLUS using the remote control?
Press the Ion-UV button on the remote control to switch the ionization on or off.
What are the safety precautions before cleaning the FAKIR VIGOR PLUS?
WARNING: Turn off the FAKIR VIGOR PLUS and unplug the power cord before starting cleaning and maintenance. This prevents the device from being accidentally turned on.
ATTENTION: Do not use abrasive cleaners or alcohol, as these would damage the casing of the FAKIR VIGOR PLUS.
Before cleaning and maintaining the FAKIR VIGOR PLUS, please switch off the device and pull the power plug out of the socket. Cleaning and maintenance of the FAKIR VIGOR PLUS is recommended every two to three months.
What are the steps to disassemble the FAKIR VIGOR PLUS for cleaning?
Carefully lay down the FAKIR VIGOR PLUS with its front facing up, take down the device according to the following 4 steps (The reassembly is done in the reverse order).
1. Take down the front cover
Press the locking tabs on both sides of the device.
Gently lift up the front cover.
2. Take down the plasma dust collector
Push the plasma dust collector towards the bottom of the device.
Hold the two tabs and lift up the dust collector.
3. Take down the HEPA filter
Do not reverse the front and back of the filter.
Immerge your hand into position A and pull out the filter.
When replacing the filter, please install the filter with the exact front-and-back direction as indicated on the sides of the filter. Do not reverse the front and back of the filter.
4. Removing the TiO2 filter
Hold the clips of both sides to pull out the filter.
5. Take down the front filter
Hold position A and lift up the front filter.
How do I clean the components of the FAKIR VIGOR PLUS?
Unit front cover:
Can be cleaned with flowing water. Please use a soft cloth to clean and avoid scraping off the paint on the cover. Avoid cleaning with hot water or rubbing with excess force. Otherwise damage or deformation could be resulted.
Front filter:
Can be cleaned with flowing water. Do not clean with hot water.
Dust sensor cover:
Use a wring dry cloth to rub off all dust on the sensor cover. Use a vacuum cleaner to eliminate the dust on the filter.
Unit body:
Take down UV lamp before cleaning. Use wring dry cloth to rub and clean.
Cleaning and maintenance of the plasma dust collector:
1. Take out the plasma dust collector and the front filter.
2. Take down the plasma dust collector.
Warning: Please wear protective gloves to avoid any cut on your fingers.
3. Clean the plasma dust collector
Use mild detergent that is of neutral acidity. Use a scouring pad or toothbrush to clean the dust collector. Achieve better result with warm water (below 40°C).
If it is hard to eliminate all dirt, presoak with diluted detergent and then use a toothbrush to scrub.
Please beware not to damage any wiring while cleaning the dust collector. In case if any electrical discharge is broken, the device will lose part of or all of its dust collection function.
Any broken wire should be thrown away instead of being left inside the unit. Otherwise, short, circuit or high-voltage spark would be resulted. Also, the circuit control of the device would be affected.
Please contact authorized Fakir Service for electrical discharge wire.
Please do not clean using acidic or alkaline detergent that can create rust on the surface of device.
4. Clean and dry
After cleaning, please completely dry the unit before use. Otherwise, it could cause electrical shock or malfunction.
If the front cover of the plasma dust collector is not properly installed, no electricity will be connected.
Please make sure the plastic wrap for the electrical discharge wire is located at its proper position.
While reinstalling, the unit should remain plugged in with the socket but being turned off.
The FILTER READY button is inside the unit (cannot be reached with finger). Please use a toothpick or other sharp object to push the FILTER READY button.
How do I reinstate the indicator lights on the FAKIR VIGOR PLUS after cleaning or filter replacement?
How to reinstate
1. PIN CLEAN Indicator
When the unit is turned off, the reinstating process for PIN CLEAN indicator is done by pushing both the FILTER READY and the TIME buttons at the same time.
2. FILTER REPLACE Indicator
When the unit is turned off, the reinstating process for FILTER REPLACE indicator is done by pushing both the FILTER READY and the FLOW buttons at the same time.
After cleaning and replacing filters, reinstate the PIN CLEAN and FILTER REPLACE indicators. Otherwise the two indicators would remaining glowing after turning on the unit.
How should I replace the UV Lamp in the FAKIR VIGOR PLUS?
The life span of UV lamp is about 5.000 hours. Replace UV lamp when it is damaged or when no blue light is observed.
Before replacing the UV lamp, take down the front cover, plasma dust collector and filters.
Softly twist the UV lamp, remove the lamp tube from its position, and insert a lamp tube of the same model.
What are the possible causes and solutions for the FAKIR VIGOR PLUS not running?
Table: Troubleshooting for FAKIR VIGOR PLUS
| Error | Possible Cause | Remedy |
|---|---|---|
| Device does not run. | A) Plug is not inserted or the device is not switched on. B) Not assembled correctly. | A) Insert plug and switch on the device. B) Check correct assembly. |
| While the air quality is monitored, only one LED lights up all the time. | A) The room air was clean the whole time. B) The air purifier is too far from existing irritants. | A) To test the function, increase the pollution level in the room by influencing the ionic air purifier with cigarette smoke or dust. B) Place the device closer to the source of dirt (smoke or similar). |
| While the air quality is monitored, two LEDs light up all the time. | Polluted air constantly enters the room or the air is permanently polluted, e.g., by smoking. | Test the air purifier in clean room air. Keep doors closed. |
| The air quality control constantly switches back and forth. | The sensor for irritants can be influenced by radio-operated devices (e.g. cordless telephone). | Maintain sufficient distance to radio-operated devices. |
| The dust sensor blinks constantly. | Sensor is dirty. | Clean sensor. |
| Odor sensor is not working. | A) Room air values were not saved. B) The sensitivity of the sensor may be impaired at the beginning or after prolonged non-use. This regulates itself within a few days of operation. | A) Resave room air values (see “Before initial operation”). B) Let the device be connected to the mains for a few days. |
| Air is not purified. | A) Filter is dirty. B) Discharge wire of the electrostatic filter is dirty or defective. | A) Clean or replace filter. B) Clean or replace discharge wires. |
What should I do if the FAKIR VIGOR PLUS unit is not working even after turning it on?
Check if the plug has loosened or disconnected with the socket.
Check if the FAKIR VIGOR PLUS unit has been properly reassembled after being cleaned. The unit will not operate if the plasma dust collector or the front cover is not properly installed.
Why is it so hard for the filter in the FAKIR VIGOR PLUS to get rid of dust and odor?
Check if the front and back of the filter have been mistakenly reversed.
The filter has been saturated with a serious amount of dust. Please replace the filter.
Why is it so difficult to eliminate dust and odor using the plasma dust collector in the FAKIR VIGOR PLUS?
The electrical discharge wires or the plasma dust collector already gets too dirty. Please refer to the relevant sections on how to clean and maintain.
Check if any electrical discharge wire has been disconnected or broken. Please fix it or contact the distributor for additional purchase.
What should I do if the dust and irritant sensor on the FAKIR VIGOR PLUS keeps blinking?
Since the top of the sensor accumulates more dust, which decreases the efficiency of the sensor. Please refer to the relevant page for the cleaning of the sensor.
What should I do if the odor sensor on the FAKIR VIGOR PLUS does not work?
Please let the sensor retain in memory a fresh air condition (refer to the relevant paragraph under before use).
When first purchased or when the unit has been unplugged for over a week, the sensor will not be as sensitive. After 1 or 2 days of operation, the sensor will regain its sensitivity.