How do I prepare the mounting surface and install the wall box for the EXTRON DTP T UWP 332 D?

ATTENTION:

• Installation and service must be performed by authorized personnel only.

• The installation shall be in accordance with applicable provisions of the National Electrical Code and any local electrical codes.

NOTE: Use a wall box with a depth of at least 3.0 inches (7.6 cm). Alternatively, the included mud ring (MR 200) can be used.

Step 1 – Disconnect Power

Disconnect all equipment power sources.

Step 2 – Prepare the Mounting Surface

a. Place the wall box against the installation surface and mark the opening guidelines. TIP: Use a level to mark the opening.

b. Cut out the material from the marked area.

c. Secure the wall box to the wall stud with 10-penny nails or #8 or #10 screws, leaving the front edge flush with the surface.

d. Run all required cables and secure them with cable clamps. TIP: In order to fit the unit in the junction box, do not install boots on TP cables and RJ-45 connectors.


What are the front panel connections on the EXTRON DTP T UWP 332 D?

A. Audio input connector — Connect an unbalanced stereo audio source to this 3.5 mm mini stereo jack. NOTE: The units do NOT embed analog audio onto the HDMI signal. This analog audio signal is transmitted simultaneously with audio embedded within the HDMI signal.

B. HDMI input connector — Connect an HDMI cable between this port and the output port of the digital video source.

C. VGA input connector — Connect a VGA cable between this port and the output port of the video source.

D. IR output connector — Connect an IR device to this 2-pole, 3.5 mm captive screw pass-through connector for IR control. The top pole is for Signal (S) and the bottom pole is for Ground (G).

E. Mini USB port — Connect a male Mini USB B cable to this port for SIS configuration and firmware updates.


What are the rear panel connections on the EXTRON DTP T UWP 332 D?

A. DC power input connector — Wire and plug the included external 12 VDC power supply into this 2-pole connector. See power connection instructions before wiring.

B. Over DTP connector — Connect an RS-232 device to this 3-pole, 3.5 mm captive screw connector for pass-through RS-232 control.

C. Remote connector — Connect an RS-232 device, contact closure device, or both to this 5-pole, 3.5 mm captive screw connector to control switching on the unit.

RS-232 — To control the unit through this port, connect an RS-232 device and configure it as follows: 9600 baud rate, 8 data bits, 1 stop bit, no parity.

Contact — Momentarily short pins 1 or 2 to ground (G) to select the corresponding input. Connect pins 1 and 2 to ground (G) to set the unit to auto switch mode. The device selects the highest active input (auto switch).

D. DTP OUT connector — Connect one end of a twisted pair cable to this RJ-45 connector and the opposite end to a compatible receiver. ATTENTION: Do not connect this device to a telecommunications or computer data network.

E. Reset button — Use an Extron Tweeker or small screwdriver to press and hold the recessed button for 6 seconds while the switcher is running to perform a factory reset.


How do I wire the Remote connector for RS-232 and contact closure control on the EXTRON DTP T UWP 332 D?

To wire the 5-pole, 3.5 mm captive screw Remote connector for both RS-232 and contact closure control, follow the pinout below:

Pin Function
Tx Transmit pin on connected unit
Rx Receive pin on connected unit
G Ground
1 Pin 1 for contact closure control
2 Pin 2 for contact closure control

What are the cabling requirements for connecting the EXTRON DTP T UWP 332 D?

For optimal performance when running cables between the transmitter and receiver, Extron highly recommends the following:

• RJ-45 termination with shielded twisted pair cable must comply with TIA/EIA-T568B wiring standard for all connections.

• Use shielded twisted pair cable, 24 AWG solid conductor or better, with a minimum cable bandwidth of 400 MHz.

• ATTENTION: Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable.

• Use shielded RJ-45 plugs to terminate the cable.

• Limit the use of RJ-45 patches. Overall transmission distance capabilities vary depending on the number of patches used. If possible, limit the number of patches to 2 total.

• If RJ-45 patches must be used in the system, shielded patches are recommended.


What is the TIA/EIA T568B wiring color code for the EXTRON DTP T UWP 332 D?

Pin Wire color
1 White-orange
2 Orange
3 White-green
4 Blue
5 White-blue
6 Green
7 White-brown
8 Brown

What are the maximum transmission distances for the EXTRON DTP T UWP 332 D models?

• The DTP T HWP/UWP 232 D models can transmit video, control, and audio (if applicable) signals up to 230 feet (70m).

• The DTP T HWP/UWP 332 D models can transmit video, control, and audio (if applicable) signals up to 330 feet (100m).


How do I connect the outputs from a compatible receiver for the EXTRON DTP T UWP 332 D system?

a. DVI or HDMI output connector — Connect a DVI or HDMI cable (depending on your receiver type) between this port and the input port of the display.

b. Audio output — Connect a stereo audio device to this 3.5 mm mini stereo jack to receive the passed-through unbalanced audio.

c. RS-232/IR Pass-Through connector — Plug an RS-232 or modulated IR device into the RS-232/IR pass-through port.


How do I power the EXTRON DTP T UWP 332 D?

The units can be powered one of two ways:

• Locally with the included power supply. A compatible receiver can then be powered remotely through the DTP line.

• Remotely via the DTP line by a locally powered DTP 230 or 330 compatible device.

To wire the 2-pole captive screw connector for the included external 12 VDC power supply, connect the wire with the smooth insulation to the positive (+) terminal and the wire with the ridges to the negative (-) terminal.


What is the final installation procedure for the EXTRON DTP T UWP 332 D?

a. Make all connections, power the units, and test the system for satisfactory operation.

b. At the power outlet, unplug the power supply.

c. Mount the transmitter into the wall box, and attach the supplied Decora faceplate to the unit.

d. At the power outlet, reconnect the power supply. This powers up both units.


How do I interpret the front panel LEDs on the EXTRON DTP T UWP 332 D?

A. Power LEDs — These two-color front panel LEDs on the transmitters light to indicate signal and power status as follows:

Amber – The unit is receiving power but there is no signal on the HDMI or VGA inputs.

Green – The unit is receiving power and a signal is present on the HDMI or VGA inputs.

B. Auto Switch LED — Lights green when auto switch is active.

C. HDCP LED — Lights green when HDMI input has been authenticated on the source device.


How can input switching be performed on the EXTRON DTP T UWP 332 D?

Input switching can only be performed via auto switching, RS-232, or contact closure through the rear panel connectors.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD EXTRON DTP T UWP 332 D (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.