ENERLITE 51300 (01) PDF MANUAL


Post questions, comments, reviews or errors in the comment box below.

Your File is Ready … Download PDF

CLICK HERE TO DOWNLOAD ENERLITE 51300 (01) PDF MANUAL


PDF Content Summary: INSTALLATION INSTRUCTIONS 51300 120V Dimmer for Dimmable LED/ CFL Incandescent / Halogen (Single Pole/ 3-Way) 1. Connect the HOT wire to the BLACK wire on the switch 2. Connect the load wire to the uninsulated RED wire on the switch a. If using switch as 3-way, remove insulating label from red wire and connect EACH RED wire to separate TRAVELER wires. 3. Connect GROUND wire to GREEN wire on the switch. 4. Mount the dimmer to the box with "UP" indicator pointing up. 5. Turn on Circuit Breaker Single-Pole Wiring HOT BLACK RED LOAD SPECIFICATIONS 120 VAC GREEN 60Hz Light DIMMER ADJUSTMENT GROUND Voltage ............................................................................................120VAC, 60Hz Incandescent/ Halogen..................................................................................700W Dimmable LED and Dimmable CFL...............................................................150W Operating Temperature.........................................................................32°F-104°F DESCRIPTION/ FEATURES 3-Way Wiring The 51300 is an Incandescent/Halogen and dimmable LED & CFL HOT BLACK Dimmer. This Dimmer is designed to replace a standard light switch, dimmer, or a three-way lighting control (see 3-Way Wiring, Figure 2). Rocker Switch: ON/OFF 120 VAC 60Hz 3 Tuning dial: UP=More Bright DOWN= Less Bright Slider: Light Level Control MULTIGANG INSTALLATION When installing more than one control in the same wall box, it may be necessary WARRANTY INFORMATION Turn the POWER OFF at the circuit breaker before installing the Dimmer Read and understand these instructions before installing. This device is to remove the side tabs before installing (see below). Using pliers, bend each tab back and forth until they break off. Repeat for each tab to be removed. Removal of tabs WILL REDUCE MAXIMUM LOAD CAPACITY. This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims must be verified and approved by Enerlites, Inc. Warranties from other Enerlites products may vary. This warranty is nontransferable and does not cover intended for installation in accordance with the National Electric Code and local normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, regulations. It is recommended that a qualified electrician performs this alteration, modification, or improper installation. To the fullest extent permitted by the applicable installation. Make sure to turn off the circuit breaker or fuse(s) and make sure power is off before wiring the device. 1.Power the lights on by using the Rocker switch and move the dimmer's slider down NEUTRAL Figure 1 2. to Fine the Tuning: bottom. To achieve the lowest light level, turn the Tuning dial Upwards/ Downwards until desired level is reached. (Note: DO NOT overturn. The Dial will stop turning at lowest/ highest outputs). 3. To verify the setting, turn the dimmer off then back on. Repeat step 2 if all bulbs do not turn on. 4. Turn adjustment dial Up until all lights come on. Some dimmable CFLs and LEDs require at least two light bulbs to be installed or 10 total wattage on one lamp for proper operation. Figure 2 WARNING state law, Enerlites shall not be liable to the purchaser or end user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages. Enerlites’ total liability under this or any other warranty, express or Use copper wire only implied, is limited to repair, replacement or refund. Repair, replacement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory. NOTES: The dimmer can be used as a Single Pole or 3-way switch. Only one dimmer is needed for each 3-way application. Tabs Removed for For use with incandescent, halogen, dimmable CFL and LED lights. Mulitgang installation © 2016 Enerlites Inc. CA, U.S.A. ENERLITES.COM 0210160055-01 3-Way Switch RED • Replaces current light switch using home's existing wiring GREEN RED • Slide dimmer and rocker switch turns lights on to a preset level • Provides wider dimming range for dimmable LED and CFL bulbs than Light standard incandescent dimmers GROUND • Suitable for multi-gang installations • Dim lighting for increased energy savings NEUTRAL• Adjustable sensitivity levels on the control slider. • Designed for compatibility with most high efficiency light bulbs. 1 2 Dimmable LED/CFL WIRING DIRECTIONS When using the 51300 Dimmer to control LED/CFL lights in conjunction with another 51300 Dimmer to control Incandescent /Halogen lights follow this Derating Chart for Maximum Capacity on EACH device. Then the Maximum COMBINED Wattaged for the If the combined Incandescent/Halogen bulbs on EACH attached dimmer: Wattage of ALL LED/CFL bulbs If NO Tabs are removed then on 1 dimmer is: Max Wattage is: LOAD If 1 side of Tabs are removed then Max Wattage is: If 2 sides of Tabs are removed then Max Wattage is: 0W1-25W 26-50W 51-75W 76-100W 101-125W 126-150W 700W 500W 400W 300W 200W 100W 0W 600W 400W 300W 200W 100W 50W 0W 500W 300W 200W 100W 50W 0W0W If you are using ONLY LED/CFL bulbs on ALL 51300 Dimmers, DO NOT USE this Derating Chart. Follow the LED/ CFL Derating Chart. LED/CFL Derating Chart Load Capacity when Tabs are removed from: 0 Sides 1 Side 2 Sides 150W 150W 150W TRAVELER TRAVELER


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE - USER MANUAL

OWNER GUIDE - OWNER MANUAL

REFERENCE GUIDE - REFERENCE MANUAL

INSTRUCTION GUIDE - INSTRUCTION MANUAL

Leave a Reply