Free English EMERSON HF1160BQ02 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD EMERSON HF1160BQ02 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.


How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.


What is the net weight of the EMERSON HF1160BQ02?

The net weight of the EMERSON HF1160BQ02 is 19.8 Lbs.


What are the steps to take before servicing or cleaning the EMERSON HF1160BQ02?

Before servicing or cleaning the EMERSON HF1160BQ02, switch power off at the service panel and lock the service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.


What should I do if I am uncertain of a part description for the EMERSON HF1160BQ02 during unpacking?

If you are uncertain of a part description for the EMERSON HF1160BQ02 during unpacking, refer to the exploded view illustration in the manual.


What should I do if any parts are missing for my EMERSON HF1160BQ02 during unpacking?

If any parts are missing for the EMERSON HF1160BQ02, call 1-800-654-3545 for replacement parts before proceeding.


What is the minimum clearance required from the floor to the blades of the EMERSON HF1160BQ02?

The EMERSON HF1160BQ02 fan must be hung with at least 10 feet of clearance from the floor to the blades.


What is the required secure mounting load capacity for the support beam or joist supporting the EMERSON HF1160BQ02?

The support beam or joist must be secure and capable of withstanding a load of at least 50 pounds for the EMERSON HF1160BQ02.


What type of outlet box must be used for installing the EMERSON HF1160BQ02?

The outlet box and joist must be securely mounted and capable of supporting at least 50 pounds. Use only a U.L. outlet box listed as “Acceptable for Fan Support of 22.7kg. (50 lbs.) or less” for the EMERSON HF1160BQ02.


What caution should be observed when installing the blade assemblies on the EMERSON HF1160BQ02 motor assembly?

The blade assemblies must be mounted on the motor assembly so that the “This Side Up” label is visible at the top of the motor for the EMERSON HF1160BQ02.


What should be done to avoid personal injury when installing, balancing, or cleaning the blades of the EMERSON HF1160BQ02?

To reduce the risk of personal injury with the EMERSON HF1160BQ02, do not bend the blade flanges when installing the blades, balancing the blades, or cleaning the fan. Do not insert foreign objects between rotating fan blades.


How do I remove the setscrews from the top of the motor yoke for the EMERSON HF1160BQ02 assembly?

Use the setscrew wrench (supplied) to remove the two setscrews from the top of the motor yoke for the EMERSON HF1160BQ02, and retain the setscrews for future use.


What wires must be routed through the center hole in the motor cover for the EMERSON HF1160BQ02?

The three 48″ motor wires and the safety cable must be separated, untwisted, and unkinked, and then routed through the center hole in the motor cover for the EMERSON HF1160BQ02.


How are the motor cover and motor assembly secured for the EMERSON HF1160BQ02?

Secure the motor cover to the motor assembly for the EMERSON HF1160BQ02 by installing two #8-32 x 1/4″ pan head screws and two #8 external tooth lockwashers (supplied), after aligning the two holes in the motor cover with the threaded holes in the motor yoke.


How should the motor wires and safety cable be routed after passing through the ceiling cover for the EMERSON HF1160BQ02?

Route the three 48″ motor wires and the safety cable through the center hole in the ceiling cover and position the ceiling cover over the motor yoke for the EMERSON HF1160BQ02.


How is the downrod seated into the motor yoke for the EMERSON HF1160BQ02?

Route the three 48″ motor wires and the safety cable through the hanger ball/downrod assembly and seat the downrod in the motor yoke for the EMERSON HF1160BQ02.


What is the critical step involving the clevis pin for the EMERSON HF1160BQ02 motor coupling?

It is critical that the clevis pin in the motor coupling of the EMERSON HF1160BQ02 is properly installed. Failure to verify that the pin is properly installed (as shown in Figure 6) could result in the fan falling.


What is the procedure for securely tightening the setscrews against the downrod for the EMERSON HF1160BQ02?

Reinstall the previously removed two 5/16-18 setscrews in the motor yoke. While pulling up on the hanger ball, securely tighten both setscrews against the downrod using the allen wrench, supplied, for the EMERSON HF1160BQ02.


What is the required length to measure up above the top of the hanger ball/downrod assembly before cutting and stripping wires for the EMERSON HF1160BQ02?

Before installing the EMERSON HF1160BQ02 fan, measure up approximately 6 to 9-inches above the top of the hanger ball/downrod assembly, then cut off excess wires and strip back insulation 1/2-inch from the end of the wires.


What is the required wire size (A.W.G.) for a 50-100 ft installed wire length when wiring the EMERSON HF1160BQ02?

For an installed wire length of 50-100 ft when wiring the EMERSON HF1160BQ02, the required wire size is 12 A.W.G.


What electrical precautions must be taken before wiring the EMERSON HF1160BQ02?

To avoid possible electrical shock before wiring the EMERSON HF1160BQ02, be sure electricity is turned off at the main fuse box. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.


How should the green grounding wire be connected for the EMERSON HF1160BQ02 during wiring?

Connect the green grounding wire from the hanger ball, the green grounding wire from the hanger bracket, and the green grounding wire from the EMERSON HF1160BQ02 fan to the grounding conductor of the supply (this may be a bare wire or wire with green colored insulation). Securely connect wires with a wire connector (supplied).


How should the fan motor white wire be connected during the wiring of the EMERSON HF1160BQ02?

Securely connect the fan motor white wire to the supply white (neutral) wire using a wire connector (supplied) for the EMERSON HF1160BQ02.


How should the fan motor black (hot) wire be connected during the wiring of the EMERSON HF1160BQ02?

Securely connect the fan motor black (hot) wire to the supply black wire (hot) using a wire connector supplied for the EMERSON HF1160BQ02.


What is the required check after making all wire connections for the EMERSON HF1160BQ02?

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire for the EMERSON HF1160BQ02. Do not operate the fan until blades are in place; noise and fan damage could result.


How should the wires be pushed into the outlet box after making connections for the EMERSON HF1160BQ02?

After connections have been made for the EMERSON HF1160BQ02, turn wires upward and carefully push wires into the outlet box, with the white and green wires on one side of the outlet box and the black wires on the other side of the outlet box.


How are the threaded studs installed in the hanger bracket for the EMERSON HF1160BQ02 wall control installation?

Screw the two 3/4″ threaded studs (supplied) into the tapped holes in the hanger bracket for the EMERSON HF1160BQ02.


How is the ceiling cover secured in place after lifting it up to the threaded studs for the EMERSON HF1160BQ02?

Secure the ceiling cover in place for the EMERSON HF1160BQ02 by sliding lockwashers over the threaded studs and installing the two knurled knobs (supplied). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling.


What is the warning regarding electrical wires when installing the ceiling cover for the EMERSON HF1160BQ02?

To avoid possible fire or shock with the EMERSON HF1160BQ02, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.


What is the warning associated with the wall control installation for the EMERSON HF1160BQ02 if the wall switch is turned off?

Turning off the wall switch is not sufficient to avoid possible electrical shock when installing the wall control for the EMERSON HF1160BQ02. Be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.


What is the required setup for the ceiling fan before installing the SW95 Wall Control for the EMERSON HF1160BQ02?

The ceiling fan must be set at the highest speed setting before installation of the Wall Control for the EMERSON HF1160BQ02.


What caution should be observed when connecting the Wall Control BLACK wire for the EMERSON HF1160BQ02?

Use only the wire connectors supplied with the new Wall Control to secure electrical connections when connecting the Wall Control BLACK wire to the Fan/Motor Lead (BLACK or RED) wire for the EMERSON HF1160BQ02.


What is the note regarding WHITE neutral wires during the wall control installation for the EMERSON HF1160BQ02?

The WHITE neutral wires inside the electrical box must be connected together for proper operation of the wall control for the EMERSON HF1160BQ02. NEVER connect the WHITE neutral wires to the Wall Control. Incorrect wiring WILL damage this control.


What should be done after installing the knob on the shaft of the Wall Control for the EMERSON HF1160BQ02 to complete installation?

After pressing the knob onto the shaft of the Wall Control for the EMERSON HF1160BQ02, rotate the knob counter-clockwise to the full OFF position. To complete installation, restore power at the main fuse box or circuit breaker panel.


What is the warning regarding using any other control not specifically approved for the EMERSON HF1160BQ02?

The use of any other control not specifically approved for the EMERSON HF1160BQ02 could result in fire, shock and personal injury.


What should be inspected for after completing the test run of the EMERSON HF1160BQ02?

After completing installation, test run the EMERSON HF1160BQ02 fan in normal operation manner. Inspect for any possible shake or wobble which may be caused by binding as a result of “tight cable”. If this should happen, shut off power supply and re-check instructions to correct problem.


What is the probable cause if the EMERSON HF1160BQ02 fan sounds noisy?

The probable causes if the EMERSON HF1160BQ02 fan sounds noisy are:

Blades not attached to fan.

Loose screws in motor housing.

Screws securing fan blade flanges to motor hub are loose.


What are the suggested remedies if the EMERSON HF1160BQ02 fan sounds noisy?

The suggested remedies if the EMERSON HF1160BQ02 fan sounds noisy are:

Attach blades to fan before operating.

Check to make sure all screws in motor housing are snug (not over-tight).

Check to make sure the screws which attach the fan flanges to the motor hub are tight.

Make sure main power is turned OFF.


What is the probable cause if the EMERSON HF1160BQ02 fan wobbles excessively?

The probable causes if the EMERSON HF1160BQ02 fan wobbles excessively are:

Setscrews in motor coupling are loose.

Setscrew in hanger ball / downrod assembly is loose.

Hanger bracket and / or ceiling outlet box is not securely fastened.

Fan blades out of balance.


What are the suggested remedies if the EMERSON HF1160BQ02 fan wobbles excessively?

The suggested remedies if the EMERSON HF1160BQ02 fan wobbles excessively are:

Tighten both setscrews securely in the motor coupling.

Tighten the setscrew in the hanger ball / downrod assembly.

Tighten the hanger bracket screws to the outlet box, and/or secure outlet box.

Interchanging an adjacent (side-by-side) blade pair can redistribute the weight and result in smoother operation.


What is the probable cause if the EMERSON HF1160BQ02 fan will not start?

The probable causes if the EMERSON HF1160BQ02 fan will not start are:

Fuse or circuit breaker blown.

Loose power line connections to the fan, or loose switch wire connections in the switch housing.


What are the suggested remedies if the EMERSON HF1160BQ02 fan will not start?

The suggested remedies if the EMERSON HF1160BQ02 fan will not start are:

Check main and branch circuit fuses or circuit breakers.

Check line wire connections to fan and switch wire connections in the switch housing.

Make sure main power is turned OFF.


What is the warning about using water when cleaning the EMERSON HF1160BQ02?

Do not use water when cleaning your EMERSON HF1160BQ02 ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.


What is the maintenance needed for the bearings of the EMERSON HF1160BQ02?

All bearings of the EMERSON HF1160BQ02 are permanently lubricated and do not require further lubrication.


How can the EMERSON HF1160BQ02 fan be cleaned?

The EMERSON HF1160BQ02 fan may be wiped off with a damp cloth. Do not allow the motor to get wet. Do not use solvents or harsh detergents.


What are the requirements for the Wall Control when used with the EMERSON HF1160BQ02?

To avoid erratic speeds and possible damage to your ceiling fan, use the Wall Control only with fans pull chain switches set to their high speed settings for the EMERSON HF1160BQ02. All ceiling fans must be completely installed before installation of the Wall Control.


What is the electrical supply line requirement for the new Wall Control when installing it with the EMERSON HF1160BQ02?

Your new Wall Control will require a grounded electrical supply line of 120 volts AC, 60 HZ circuit when installing it with the EMERSON HF1160BQ02.


What electrical precaution is necessary before attempting to install the ceiling fan mounting plate on the outlet box when replacing an existing wall control for the EMERSON HF1160BQ02?

Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan mounting plate on the outlet box when replacing an existing wall control for the EMERSON HF1160BQ02.


What is the required setting for the ceiling fan before installing the Wall Control for the EMERSON HF1160BQ02?

The ceiling fan must be set at the highest speed setting before installation of the Wall Control for the EMERSON HF1160BQ02.


What is the required electrical precaution if the wall switch is turned off when installing the wall control for the EMERSON HF1160BQ02?

Turning off the wall switch is not sufficient to avoid possible electrical shock when installing the wall control for the EMERSON HF1160BQ02. Be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.


What hardware is used to secure the faceplate to the Wall Control when installing it for the EMERSON HF1160BQ02?

Assemble the faceplate to the Wall Control for the EMERSON HF1160BQ02 using the two previously removed 6-32 screws.


What action completes the installation of the Wall Control knob for the EMERSON HF1160BQ02?

To complete the installation of the Wall Control knob for the EMERSON HF1160BQ02, press the knob onto the shaft of the Wall Control and rotate the knob counter-clockwise to the full OFF position. Then, restore power at the main fuse box or circuit breaker panel.


What is the warning if the wires and wire connectors are not completely tucked into the outlet box when positioning the Wall Control for the EMERSON HF1160BQ02?

Carefully tuck all wires and wire connectors into the outlet box and position the Wall Control onto the outlet box for the EMERSON HF1160BQ02.


What are the parts contained in the “Parts Bag Containing” for the EMERSON HF1160BQ02?

The parts bag for the EMERSON HF1160BQ02 contains the following hardware:

Wire Connector (3)

Pin, Clevis

Clip, Hairpin

Nut, Knurled, 8-32 (2)

Lockwasher, External Tooth, #8 (4)

Stud, Threaded, 8-32 x .75″ (2)

Screw, Phillips Hex Head, 1/4-20 x 1/2″ (7)

Lockwasher, Split (7)

Washer, Flat (7)

Screw, Pan Head, #8-32 x 1/4″ (2)

Wrench, Setscrew

Clamp, Safety Wire (2)

Screw, Eye


What is the precaution regarding intermixing blades between fans for the EMERSON HF1160BQ02?

Intermixing blades between fans for the EMERSON HF1160BQ02 can cause excessive wobble. Keep blades in original sets of three.


What is the note about humming noise when using a solid state motor speed control with the EMERSON HF1160BQ02?

When any solid state motor speed control is used with the EMERSON HF1160BQ02, a humming noise may be present in the fan on low speed. This hum in no way affects the operation of the fan and is acceptable in most installations.


What is the note regarding the SW95 Wall Control and fan speed setting for the EMERSON HF1160BQ02?

The SW95 Wall Control for the EMERSON HF1160BQ02 is designed to operate only one ceiling fan, and not an accessory light kit. The SW95 Wall Controls do not require a receiver. The SW95 Wall Control is rated for 1.25 Amp, 120 VAC, 60 HZ full load. To avoid erratic speeds and possible damage to your ceiling fan, use the Wall Control only with fans pull chain switches set to their high speed settings. All ceiling fans must be completely installed before installation of the Wall Control.


What is the warning if the clevis pin in the motor coupling of the EMERSON HF1160BQ02 is not properly installed?

It is critical that the clevis pin in the motor coupling of the EMERSON HF1160BQ02 is properly installed. Failure to verify that the pin is properly installed (as shown in Figure 6) could result in the fan falling.


What are the wire colors of the fan that are 48-inches long for the EMERSON HF1160BQ02?

The EMERSON HF1160BQ02 fan comes with black, green ground and white wires that are 48-inches long.


What is the caution about not operating the EMERSON HF1160BQ02 until blades are in place?

Do not operate the EMERSON HF1160BQ02 fan until blades are in place. Noise and fan damage could result.


What is the general information about the SW95 Wall Control for the EMERSON HF1160BQ02?

The SW95 Wall Control for the EMERSON HF1160BQ02 is designed to operate only one ceiling fan, and Not an accessory light kit. The SW95 Wall Controls do not require a receiver. The SW95 Wall Control is rated for 1.25 Amp, 120 VAC, 60 HZ full load.


What is the warning regarding checking wire connections for the EMERSON HF1160BQ02 wall control wiring?

Check to see that all wire connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for ground for the EMERSON HF1160BQ02.


What is the note regarding using larger U.L. listed wire connectors for the EMERSON HF1160BQ02 supply source wires?

Use larger U.L. listed wire connectors if supply source wires for the EMERSON HF1160BQ02 are larger than #12 AWG.


What is the warning about substituting parts or accessories for the EMERSON HF1160BQ02?

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage for the EMERSON HF1160BQ02.


What are the package contents for the EMERSON HF1160BQ02?

The package contents for the EMERSON HF1160BQ02 are:

Fan Motor Assembly (1)

Ceiling Canopy (1)

Motor Coupler Cover (1)

Fan Blade Assemblies (3)

Hanger Bracket (1)

Hanger Ball/Downrod Assembly (1)

SW95 Wall Control & Hardware (1)


What parts and quantities are in the Hardware Contents for the EMERSON HF1160BQ02?

The Hardware Contents for the EMERSON HF1160BQ02 are:

Threaded Studs, #8-32 x .75″ (2)

Knurled Knobs, #8-32 (2)

Lockwashers, External Tooth #8 (4)

Wire Connectors (3)

Clevis Pin (1)

Hairpin Clip (1)

1/4-20 x 1/2″ Phillips Hex Head Screws (7)

Split Lockwashers (7)

Flat Washers (7)

#8-32 x 1/4″ Pan Head Screws (2)

Safety Wire Clamps (2)

Eye Screw (1)

Setscrew Wrench (1)


CLICK HERE TO DOWNLOAD EMERSON HF1160BQ02 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.