Click here to download ELITECH LOGET 6 (01) PDF MANUAL


PDF Content Summary:

****** Page 1 ****** User Manual Product Overview LogEt 6 Single-Use PDF Temperature Data Logger Elitech@ Operating Instructions The data logger is mainly used to record the temperature of food in storage and transportation. It helps accurately monitor the whole process to indicate whether food is safe and fresh Structure Description Action Start the data logger Stop the data logger Show status Set Mark Operation Press and hold the start button for about 5 seconds Press and hold the stop button for about 5 seconds Press and release the start button Press and hold the start button for about 5 seconds 1 2 3 4 5 6 USB Port LCD Screen Configuration Info Label Buttons Sensor Barcode Label LogEt 6 START -200 STOP View data After the data logger is plugged into a computer USB port, a PDF data report will be created automatically. The LCD screen will display report generation progress. When created, the report can be viewed. The creation will not last for more than 4 minutes. Description of the menus Technical Parameters Temperature measuring range -300C +700C Resolution Temperature accuracy Sensor type Memory capacity Log interval Alarm threshold o.lac ±0.50c ( -20-+400C ) ± IOC (others) internal NTC thermistor 16000 readings (MAX) 10 sec —24 hr default (customizable) Elitech Alarm type Data interface Report type Battery Battery life Protection grade single/cumulative USB port PDF format single-use 3 6V lithium battery 2 years (stored and used under normal temperature environment) IP65 Menu 1 2 3 4 5 6 7 8 Description Timing start Delayed start Not started Start status Readings Max temperature Min temperature MKT value Average temperature Example 8, Menu 9 10 11 12 13 14 15 16 Description Upper limit 3 Upper limit 2 Upper limit 1 Lower limit 1 Lower limit 2 Current time Sensor fault PDF creation progress Example n Parameter Instruction Users can reconfigure parameters via the data management software The reconfiguration will clear the original parameters and data Alarm threshold Alarm zone Alarm type Alarm delay MKT Description of the combined indicators and other status The logger supports three upper limits and two lower limits The range that is out of alarm thresholds Single Cumulative The logger records the single time for continuous out-of-limit events The data logger records the cumulative time of all the out-of-limit events. Display 3 (group) (group) (group) (group) Description No alarm Alarmed Min Max Display b The logger does not alarm immediately when the temperature is within the alarm zone. It begins to alarm only when the alarm delay time elapses Mean kinetic temperature is an evaluation method that indicates the effect of temperature fluctuation on stored articles 1/4 Description Mark Data clear USB communicating 2/4

****** Page 2 ****** Elitech@ User Manual Report LogEt 6 Single-Use PDF Temperature Data Logger File Created At: 2017/02106 From 201702/06 To DATA LOG File CreatedAt: 2017 evice Information ALARM Device Code • Serial Number : Mode Code : LogEt 6 EF316CIC0044 NIA 2/06 13:06:42 probe Type Firmware Version : Mark Ev WA Log Interval Ring Buffer: Stop Mode Temperature(internal) Vl.l rip Information Trip ld Description : 0000001 Lc$t 6 onfiguration Information Start Mode : Start Delay Time Base : one 3: HI: over 8.0 Ideal Region L 1: belOW 2.0 •C Manual UTC +08:co Allow Ti unlimited 10S Disable Manua u:oz: 78 18 11;ogØ 19.6 •c 19.9 •c 0.1 ‘C •c 20 20.3 • 20.3 •c 20.3 20.3 •c 20.3 •c 20.3 •c 20.3 ‘C zorc 20.2 •c 20.2 •c 2-0.2 •c 20.2 “C 20.1 •c 2-0.1 •c 20.1 •c 20.1 •c 20.1 •c 20.1 •c 200 •c 200 •c 20.0 •c 200 ‘C 200 •c 11:19’/ :193B 11:19 48 11 •.21-_co 11222-8 2017/0206 mz•c 312 •c larm Type Si Sin 110b:t6 11 11 N3.s 11 1147’.28 1 laa:fJ6 11 1109:gs 11 11 •c:os IIAC•.36 11 11:4EO.B 11 1115228 1’153:18 18 21.1 •c 21.1 •c 21.1 •c 21.1 •c 21.1 •c 21.1 •c 21.1 •c 21.2 ‘C 31.1 •c 21.1 •c 12254B 1226:og 12-26:18 IZ2€:3B IZ2EßB tzn:2B 1Z27:3.B 122768 12282B tme:3B 17.290B IZ29:1B 1221.15B IZIt:5B 21.1 •c 21.2 ‘C 7.2 •c r.z•c 21.2 •c 21.2 21.2 •c I Time 2h 4m 10s Os Start Time : Stop Time Elapsed Time : Data Points S Error(Te) s Alarm 0k Time 0001 312 •c 712 •c 312 •c 712 •c 312 •c 312 •c 312 •c •813 •c 712 •c zcw ‘C 20.5 •c; 20.5 •c 20.6 20.5 •c 20-5 •c; 20.5 •c 20.5 •c 20.6 ‘C 20.8 •c 20.6 •c 20.6 ‘C 20.6 20.6 ‘C 20.6 •c 20.6 •c 20.6 ‘C 20.6 ‘C 20.7 •c 20.7 ‘C 20.7 20.7 •c 20.7 20.7 •c 20.7 •c 20.7 20.7 ac.7 •c 20.7 •c 20.7 •c 2C.g 21.1 •c 21.1 •c 21.1 •c 21.1 ‘C 21.1 •c 21.1 •c 21.1 •c 21.1 •c 212 •c 21.2 •c 212 91 rc 21 rc 21.2 •c 21.2 •c 21.2 •c 21.2 •c 21.2 •c 21 rc 21.2 •c 21 rc 21.2 •c 21 .z•c 21.2 •c ‘2:æce 12028 12075-8 12:toce 121048 12:1058 ‘2:12-CØ 12:13SØ ta:lsca ogging Summary Software Viol ons 11:02.18 ‘B.9’C tg.9<C 19.9 •c 19.9 •c 19.9 •c t g.9"C 19.9 •c 19.9 •c 19.9 •c tg.o•c 19.0 •c 19.3 •c 19B •c tgs•c 19.8 •c 19B •c 19.8 •c t gs•c t9S'C 19B •c t9S'C 19.8 •c 1124 '8 11 •24:28 11 •.24:'" t 1 •m 38 28 '177 aa 112848 Highest : Lowest Average : MKT Alarm At(Te): CCI 27.0 22.0 17.0 12.0 8.0 7.0 2.0 201702/06 11 23.4 •c 19.6 'C 20.9 •c 20.9 •c 2017/02/06 2017/02/06 2h 4m 10s 746 OvedT•) 11 •n 11 •Y-cu 11 42;26 11Ä3•.t6 11:4X3.B 11:43.4B 11 11 1145218 1146.08 1148.58 | 1.'7:36 11 47246 20.8 •c 20.8 •c 20.8 •c 20.8 'C 20.6 'C 20.8 •c 20.8 •c 20.8 •c 2C.8 •c 20-8 •c 20.8 •c 20.8 •c 20.9 "C 2C.g 'C 20.9 •c 20.9 •c 20.9 •c 2C.g 20.9 •c 20.9 •c 20.9 •c 2C.9 •c 2C.g sc ac.9 •c 20.9 •c 20.9 •c 20.g •C 20.9 20-9 •c 18 12:0048 '2:01 12:01 a 12:01 M 48 '2:01 Y 12:02: 18 120248 12:04 21 rc 21.2 •c 21.3 •c 2L3'C 21-3 •c 21.3 •c 21.3 •c 21.3 •c 21 .s•c 21.3 •c 21.3 •c 21.3 •c 21.vc 21.3 •c 21 .3 •c 21.3 •c 21.3 •c 21.4 'C 21 A •C 21 A •c 21 .3 •c 21.3 'C 21.3 'C 21.3 •c 21.3 •c 21.3 •C 21.3 'C *l.vc 21.3 •c 21 .3 •c 21.3 •c 21.3 •c 21.3 •c 12:1T.cg 17 aa 12: w.og 12M94.g 12:19SØ 12•mag 122058 v:' 3:18 348 Basic information Description of the usage 2 3 4 5 6 7 21.1 •c 21.1 •c 21.1 •c 21.1 •c 21.1 •c 31.1 •c 21.1 •c: 71.1 •C 21.0 •c 21.0 •c 21.0 •c 21.0 •c 21.0 •c 21.0 •c 21.0 •c 21.0 •c 21.0 •c 21.0 •c 21.0 •c 71.0 •c 21.0 •c 21.0 •c 21.0 •c 21.0 •c: 31.0 •c J K L M N Q 123248 IZUßB 1233:18 IZ13:3B 12143B 1735 06 122-52B 'ZW.3B 12270B 123706 7.2 •c 21.2 •c 21.2 'C 7.2 •c 7.2 •c 21.2 7.2 'C 21.2 •c 21.2 •c 21.2 'C 2017/02/06 11: 144 1127.18 112394B 11.5218 Neratal 120448 2017/0206 2017/02/06 12.544B 12242-18 File Name: EF316C100044- http:j/www e-elitech.com Configuration information Alarm threshold and related statistics Statistical information Temperature and humidity graph Temperature and humidity data details Document creation time (record stop time •F B c D F G Other pages Alarm (Alarm status as shown in the figure above) Mark Event Stop mode that has been set, Alarm status of the temperature alarm zone Total times of exceeding the temperature alarm threshold Total time Of exceeding the temperature alarm threshold Alarm delay and alarm type Alarm threshold and temperature alarm zones Actual stop mode (different from the item C) Vertical coordinate unit of the data grap Record data curve Alarm threshold Document name (serial number & description Of usage ID) Record time range in the current page Records when date changes (date & temperature) Records when the date is not changed time & temperature The first page Attention: The data above is only used as explanation of the report. Please refer to the actual document for specific configuration and information, 4/4 3/4

FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL



ELITECH LOGET 6 (01) PDF MANUAL

Leave a comment, question, review or page error below. Account not required.

This site uses Akismet to reduce spam. Learn how your comment data is processed.