What are the safety instructions I should follow before operating the unit?

Carefully read the instructions before operating the unit. This appliance is for indoor use only. The unit must be connected to a 220-240 V / 50 Hz earthed outlet. Installation must be in accordance with the regulations of the country where the unit is used. If you are in any doubt about the suitability of your electrical supply, have it checked and modified by a qualified electrician. Disconnect the power plug from the socket before dismantling, assembling, or cleaning. Avoid touching any moving parts within the appliance. Never insert fingers, pencils, or any other objects though the guard. Do not clean the unit by spraying it or immersing it in water. Never connect the unit to an electrical outlet using an extension cord. Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges. The power cord must not be immersed in water, as this could result in electric shock. A damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard. When defrosting and cleaning the appliance, only use tools recommended by the manufacturer. The air conditioner unit must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor. Avoid restarting the air conditioning unit unless 3 minutes have passed since being turned off to prevent damage to the compressor. Never use the mains plug or an external timer as a switch to start and stop the air conditioning unit. Always place the unit on a dry and stable surface. The appliance should not be installed in laundry or wet rooms. The appliance must be placed in a room without sources of ignition. Do not use or store in unventilated spaces with an area smaller than 10.1 m2 per unit. Do not open the air conditioner to attempt service or repair the unit. The refrigerant system should not be perforated or punctured. Do not cover or restrict the airflow from the outlet or inlet grills. For maximum performance, the air conditioner should be situated at least 50cm from the walls or other objects. The unit should only be used when the room temperature is between 7°C and 35°C.


What are the features of the air conditioner?

  • Self-evaporative system – no external water tank needed
  • Powerful but compact
  • LED screen, indicates temperature and operation mode
  • Enhanced design with hot air outlet positioned higher
  • 24 hour programmable timer function
  • 3 speed fan Low, Medium and High for best balance between quiet operation and maximum airflow
  • Compressor protection technology
  • Control of the air conditioner from a smartphone (P12HPW Only)

What parts are included?

  • Exhaust hose
  • Fishtail connector
  • Remote control
  • Exhaust fan outlet
  • Window Kit

How do I install the unit?

Keep the unit upright for at least 3-4 hours before using it. The unit should always be kept upright and placed on an even surface. Assemble the fishtail connector onto the hose. Assemble the exhaust hose. Extend one head of the hose and screw it into the assembled adaptor at the back of the unit anti-clockwise. It should take no less than three rotations to screw it into place. Partially open the window and fix the window kit to the window. Make sure the unit is upright and there are no obstructions to the air inlets and outlet grill. The unit should be positioned at least 50cm away from walls or other objects within the room. Fix the other end of the hose to the air-outlet window kit. The window kit is only designed to be installed with sliding or sash windows or doors. The fish tail adaptor can be used with most windows / doors. When using the cooling mode ensure that the opening left is as small as possible. The best form of installation is through a wall duct. The unit will need to be vented out in heating mode, ideally through the wall.


What are the important safeguards during installation?

The length of the soft hose extends from 28 cm to 150 cm. If the hose is extended above this length the unit may malfunction and this can invalidate the warranty. The outlet vent must be well ventilated and not obstructed as this will cause the unit to overheat. Avoid bending the air hose more than 30 degrees.


How do I use the power button?

Press the power button to turn the unit “ON” or “OFF”.


How do I adjust the temperature?

During cooling/heating function, use the temperature up and down buttons to raise or lower the temperature by 1°C for each press. The minimum temperature is 16°C and the maximum is 31°C.


How do I adjust the fan speed?

Press the fan speed button to select either LOW, MEDIUM, or HIGH fan speed. In dehumidifying function, this button is invalid as the unit is designed to run at low speed in dehumidifying mode.


How do I use sleep mode?

Press the sleep mode button until the unit enters sleep mode. The default fan speed is low, and the sleep mode indicator LED will illuminate. Under cooling mode, after one hour the set temperature will increase by 1 degree Celsius, after another hour the set temperature will increase by another degree, and will then remain set at that temperature. Under Heating Mode (P12HPW Only), after one hour the set temperature will decrease by 1 degree Celsius, after another hour the set temperature will decrease by another degree, and will then remain set at that temperature. Sleep mode cannot be used in dehumidifying and fan mode. If the internal tank becomes full, the machine will enter standby and sleep mode will be cancelled.


How do I use the swing button?

After the machine is on and mode selected, press the swing button and the louver will swing continuously up and down. By pressing this button again, the movement will stop and the louver remain fixed in position.


How do I use the programmable timer?

The in-built timer will allow you to set the unit to turn on or turn off after a set period of time. Only one timer can be used at any time.

How do I use the ON timer?

  1. When on standby, press the TIMER button, then set the number of hours you desire the unit to start by pressing the TEMP+ or TEMP- button.
  2. Once the set time has elapsed, the unit will turn on automatically.
  3. Press the POWER button before the time has elapsed and the unit will turn on as normal and the timer will be cancelled.
  4. The function and fan speed can be set whilst setting the timer.

How do I use the OFF timer?

  1. While the unit is operating, press the TIMER button then set the number of hours you desire the unit to stop by pressing TEMP+ or TEMP- button.
  2. Once the set time has elapsed, the unit will turn off automatically.
  3. Press the POWER button before the time has elapsed, the setting time will be cancelled and the unit will turn off.

How do I change the mode?

Press the mode button to select between Cooling / Heating (P12HPW ONLY) / Fan / AUTO or Dehumidify.


What does the LED display show?

The display indicates the current target temperature or the remaining timer settings. When the set temperature or the timer is adjusted, the new setting is shown. The display is also used to show error codes. Should a fault occur, see ERROR CODES.


What does the WF indicator mean?

When illuminated, this indicates that the internal water tank is full and requires emptying, following the information provided in the water drainage section.


What does the WIFI indicator mean?

When illuminated, this indicates that the unit is connected to wifi. When flashing, it indicates the unit is ready to connect to WIFI. Flashing twice per second means the unit is in normal connection mode, and flashing once every two seconds indicates the unit is in AP connection mode. To turn the WIFI function on or change between the modes, hold the fan speed button for 5 seconds.


How do I connect the air conditioner to WIFI?

Ensure that the air conditioner is close to the router during setup. The air conditioner is designed to be connected to a 2.4ghz network. The connection is set up using the “TUYA SMART” app. The app can be downloaded from your chosen app store.


What are the functions on the remote control?

The functions on the remote are the same as those on the main control panel.

  • POWER – ON/OFF Switch
  • MODE – Operation Mode
  • TIMER – Timer Mode
  • SPEED – Fan Speed Selector
  • TEMP+ – Temperature Up
  • TEMP- – Temperature Down
  • SLEEP
  • SWING

How do I perform manual drainage?

  1. When the internal water tank is full the unit will stop working and display the message “E2” on the display.
  2. Shut off the unit and unplug. Try not to move the model abruptly as this may cause water to spill out from the internal water tank.
  3. Place a tray under the water plug.
  4. Screw off the water plug and unplug the water blocker – water will drain from the container.
  5. Put the water blocker back and screw the water plug back into place.

How do I perform continuous drainage?

  1. Screw off the water plug and unplug the water blocker.
  2. Use a water pipe to connect to the water outlet.
  3. You can plumb this pipe into your current plumbing system, lead it outside, or use a water pump.

What should I consider when using continuous drainage?

This model has a self-evaporative function, which reduces the need to empty the water tank. If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated. Do not use continuous drainage if you intend to use the self-evaporating facility. In heating or dehumidifier mode you may need to use the permanent drainage.


What should I do before cleaning or performing any maintenance?

Shut off the unit and unplug from the mains before cleaning or performing any maintenance.


How do I clean the surface?

Clean the plastic housing with a duster or a soft wet cloth. Do not use chemical solvents as they may cause irreversible damage.


How do I clean the air filter?

  1. Clean the air filters every 2 weeks. If the air filter is blocked with dust, the unit’s performance will be significantly affected.
  2. Disconnect the power plug from the socket before dismantling, assembling, or cleaning.
  3. Open the air filter covers and remove the carbon (if installed) and washable mesh filter.
  4. Hoover gently the carbon filter and do not wash.
  5. Wash the mesh air filters by immersing them in warm (about 40℃) water with a neutral detergent.
  6. Rinse it and then dry it thoroughly.
  7. Carefully re-install air filters back into their cover. The optional active carbon filter (cloth) should be replaced every 3-6 months based on the environment.

What is the end of season maintenance?

  1. Pull out the plug from the drainage hole and empty the internal tank. You can also drain the water by leaning the unit.
  2. Switch the unit to low fan mode.
  3. Keep the unit in this mode for half a day until the conduit is dried. Doing this helps to keep the inside of the unit dry and prevents mold from developing.
  4. Turn off the unit and pull out the plug.
  5. Coil the wire and bind it together, then put it into the accessories space.
  6. Separate the air-exhausted pipe and store it safely.
  7. Cover the unit and keep it in a dry place.
  8. Take the batteries out of the remote control and store or dispose of them safely. Keep all accessories with the unit ready for next season.

What should I do if the unit does not work?

  • Power-on and turn on the unit.
  • Drain the internal water tank if the water-full indicator is illuminated.
  • Cancel the Timer function if it is active.
  • Use only in ambient temperatures between 7-35℃ if the room temperature is too low or too high.

What should I do if the unit does not seem to perform well?

  • Draw the curtains if the unit is in direct sunlight.
  • Close windows and turn on another air conditioner if windows or doors are open, or there is a large amount of people or a heat source in the room.
  • Clean or change the air filter if it is very dirty.
  • Clear out debris if the air inlet or air outlet is blocked.
  • Change the setting temperature if the room temperature is lower than the setting temperature.

What should I do if the unit is too loud?

Put the unit on a flat and hard surface if it is not.


What should I do if the compressor does not work?

Check the venting if the overheating protection is active. Restart the unit after 5 minutes when the compressor has cooled.


What should I do if the remote control doesn’t work?

  • Move the remote control closer to the unit and make sure it aims at the air-outlet grille.
  • Replace the batteries if they are flat.

What should I do if error code E0 appears?

If the temperature is not within 7-35 C operating range, or there is an electrical short on the temperature sensor, the unit will display error code E0. If the temperature is within the operating range, refer to the Service Centre to check the room temperature sensor or relevant circuit.


What should I do if error code E3 appears?

If there is a pipe temperature sensor failure, the unit will display error code E3. Switch off the unit, let it rest for a minimum of 30 minutes, and restart. If the error still appears, contact the service center.


What should I do if error codes E2/E4 appear?

If the water tank is full inside the machine, the unit will display error codes E2/E4. Drain out the water from the drain port at the bottom rear of the unit.


What are the technical data for the P12C and P12HPW models?

P12C P12HPW
Capacity Cooling 12,000 BTU 12,000 BTU
Heating N/A 11,000 BTU
Rated Input Cooling 1345W 1345W
Heating N/A 1391W
Running Current Cooling 6.0A 6.0A
Heating N/A 6.3A
Noise (sound power) ≤65dB(A) ≤65dB(A)
Permitted Excessive Operating Pressure 1.0/2.6 MPa 1.0/2.6 MPa
Maximum Allowable Pressure 1.2/3.2 MPa 1.2/3.2 MPa
Power Supply 220-240V/50Hz 220-240V/50Hz
Net Weight 26Kg 26Kg
Refrigerant Quantity 210g 210g
Dimension(LDH) 440x335x715 mm 440x335x715 mm

The unit must be vented outside when in Air Cooling and Heating mode.


What should I check before calling the service line?

  • Has the unit been standing upright for at least 2 hours?
  • Is the unit plugged into the mains?
  • Is the fuse OK?
  • Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit.
  • Check if the water tank is full.

CLICK HERE TO DOWNLOAD ELECTRIQ P12C (01) PDF MANUAL